At least 847 records · Page 47

SU-F-T-127: Charged Particle Transport in Condensed Media

Purpose: Provide quality interaction cross sections for charged particle Monte Carlo (MC) track structure codes and evaluate low energy electron transport in condensed media. Methods: MC methods and codes are often used to model or simulate charged particle radiation transport in matter. Detailed (or event-by-event) track structure simulations are of special interest for the modeling of the physical and chemical stages of radiation action with matter and the initial radiation damage to biological systems. They require reliable interaction cross sections of all radiation qualities considered (e.g., electrons, protons, alpha particles, light and heavy ions) with the target material under consideration, mainly in the condensed phase, including liquids and solids. Interaction cross sections are calculated using the dielectric formalism, a mixture of first principles, theoretical modeling and experimental information for bulk and surface transport and implemented into MC track structure codes. Secondary electron emission yields from amorphous solid water (ASW) and thin metal foils (copper and gold) after fast proton impact are simulated and measured experimentally. Results: After considering different transport models for bulk and surface transport and a careful modeling of the experimental geometry, simulated secondary electron emission yields follow the trends of experimental data well. Furthermore, yields for electron emissions below 50 eV are sensitive to differential elastic scattering cross sections. Conclusion: Low-energy electron transport in condensed media is still a challenge for detailed track structure simulation codes. Interaction cross-sections, transport models, and target geometry need to be considered adequately. The research was funded in part by NSF Major Research Instrumentation Program 2009, Award Number: 0923270 and by NIH/NCI R01 CA93351.

60 APPLIED LIFE SCIENCES↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-628: An Evaluation of Grid Size in Eclipse AcurosXB Dose Calculation Algorithm for SBRT Lung

Purpose: purpose of this study is to evaluate the effect of grid size in Eclipse AcurosXB dose calculation algorithm for SBRT lung. Methods: Five cases of SBRT lung previously treated have been chosen for present study. Four of the plans were 5 fields conventional IMRT and one was Rapid Arc plan. All five cases have been calculated with five grid sizes (1, 1.5, 2, 2.5 and 3mm) available for AXB algorithm with same plan normalization. Dosimetric indices relevant to SBRT along with MUs and time have been recorded for different grid sizes. The maximum difference was calculated as a percentage of mean of all five values. All the plans were IMRT QAed with portal dosimetry. Results: The maximum difference of MUs was within 2%. The time increased was as high as 7 times from highest 3mm to lowest 1mm grid size. The largest difference of PTV minimum, maximum and mean dose were 7.7%, 1.5% and 1.6% respectively. The highest D2-Max difference was 6.1%. The highest difference in ipsilateral lung mean, V5Gy, V10Gy and V20Gy were 2.6%, 2.4%, 1.9% and 3.8% respectively. The maximum difference of heart, cord and esophagus dose were 6.5%, 7.8% and 4.02% respectively. The IMRT Gamma passing rate at 2%/2mm remains within 1.5% with at least 98% points passing with all grid sizes. Conclusion: This work indicates the lowest grid size of 1mm available in AXB is not necessarily required for accurate dose calculation. The IMRT passing rate was insignificant or not observed with the reduction of grid size less than 2mm. Although the maximum percentage difference of some of the dosimetric indices appear large, most of them are clinically insignificant in absolute dose values. So we conclude that 2mm grid size calculation is best compromise in light of dose calculation accuracy and time it takes to calculate dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-684: Analysis of Cherenkov Excitation in Tissue and the Feasibility of Cherenkov Excited Photodynamic Therapy

Purpose: The irradiation of photodynamic agents with radiotherapy beams has been demonstrated to enhance tumor killing in various studies, and one proposed mechanism is the optical fluence of Cherenkov emission activating the photosensitizer. This mechanism is explored in Monte Carlo simulations of fluence as well as laboratory measurements of fluence and radical oxygen species. Methods: Simulations were completed using GAMOS/GEANT4 with a 6 MV photon beam in tissue. The effects of blood vessel diameter, blood oxygen saturation, and beam size were examined, recording spectral fluence. Experiments were carried out in solutions of photosensitizer and phantoms. Results: Cherenkov produced by a 100×100um{sup 2} 6 MV beam resulted in fluence of less than 1 nJ/cm{sup 2}/Gy per 1 nm wavelength. At this microscopic level, differences in absorption of blood and water in the tissue affected the fluence spectrum, but variation in blood oxygenation had little effect. Light in tissue resulting from larger (10mm ×10mm) 6 MV beams had greater fluence due to light transport and elastic scattering of optical photons, but this transport process also resulted in higher absorption shifts. Therefore, the spectrum produced by a microscopic beam was weighted more heavily in UV/blue wavelengths than the spectrum at the macroscopic level. At the macroscopic level, the total fluence available for absorption by Verteporfin (BPD) in tissue approached uJ/cm{sup 2} for a high radiation dose, indicating that photodynamic activation seems unlikely. Tissue phantom confirmation of these light levels supported this observation, and photosensitization measurements with a radical oxygen species reporter are ongoing. Conclusion: Simulations demonstrated that fluence produced by Cherenkov in tissue by 6 MV photon beams at typical radiotherapy doses appears insufficient to activate photosensitizers to the level required for threshold effects, yet this disagrees with published biological experiments. Experimental validation in tissue phantoms and cell studies are ongoing to clarify this discrepancy. Funding from NIH grant R01CA109558.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗

Generation Kinetics of Nonequilibrium Charge Carriers in Crystals with Deep Impurities Involving Two-Center Transitions between Band and Impurity States

A new and efficient mechanism of nonlinear photoexcitation of a transparent crystal with deep impurity centers is proposed. It is hypothesized that the energy of a quantum of light is smaller than the energy gap between the bottom of the conduction band and the impurity level, but is larger than the gap between the impurity level and the top of the valence band. The kinetics of nonlinear cascade generation of nonequilibrium charge carriers is considered taking into account two-center processes in which the energy transfer and the photon absorption occur in one and the same elementary event. The dependences of the quasi-equilibrium concentrations of nonequilibrium charge carriers in the bands and of the occupancy of impurity states on the laser-radiation intensity are obtained. It is shown that the generation process of nonequilibrium electron–hole pairs is of a threshold nature. Depending on the concentration of impurity centers, the threshold intensities can be ~10{sup 5}–10{sup 7} W/cm{sup 2}, while the setting time of the quasi-equilibrium occupancies of electronic states is ~10–0.1 ns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of response nonuniformity for the LHCb calorimeter module and the prototype of the CBM calorimeter module

A spatial nonuniformity of the response to high-energy muons is studied in the modules of the LHCb electromagnetic calorimeter and the prototype of the calorimeter module with lead plates and scintillator tiles 0.5 mm thick. The nonuniformity of the response of the inner LHCb modules to 50-GeV electrons is also measured. Software is developed for a thorough simulation of light collection in scintillator plates of a shashlik calorimeter. A model is elaborated to describe light transmission from the initial scintillation to the wavelength-shifting fiber with a subsequent reradiation and propagation of light over the fiber to the photodetector. The results of the simulation are in good agreement with data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and Properties of Gallium-Oxide Films Produced by High-Frequency Magnetron-Assisted Deposition

The properties of gallium-oxide films produced by the radio-frequency magnetron-assisted sputtering of a β-Ga{sub 2}O{sub 3} target with deposition onto sapphire substrates are studied. The as-deposited gallium-oxide films are polycrystalline and contain crystallites of the α and β phases. Exposure to oxygen plasma does not bring about the appearance of new crystallites but makes crystallites several times larger in average dimensions in the substrate plane. After annealing at 900°C, the crystallite size becomes twice as large as that in the unannealed film. The films not subjected to thermal annealing exhibit a high resistance at 20°C. In the range of 50–500°C, the conductivity of the samples (G) only slightly depends on temperature (T) and, as T is elevated further, exponentially increases with the activation energy 0.7–1.0 eV. After annealing of the films in argon at 900°C (30 min), the conductivity G starts to sharply increase at T ≈ 350°C. In the dependence of lnG on T {sup –1}, a maximum in the range of 470–520°C and a portion of decreasing conductivity at higher temperatures are observed. The unusual temperature dependence of the conductivity after annealing is attributed to a change in the structure and phase composition of polycrystalline gallium-oxide films and, possibly, to some effects at the surface. The structures produced on insulating substrates are solar blind in the visible wavelength region and sensitive to radiation in the ultraviolet region (222 nm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive simultaneous bidirectional shearing interferometry using tailored spatially coherent light

Measurements of wavefront deformations can be carried out with the help of lateral shearing interferometers. Here the focus is on a setup providing two shears along orthogonal directions simultaneously to generate the data needed for a reconstruction. We describe a diffractive solution using Ronchi phase gratings with a suppressed zeroth order for both the doubling of the wavefront under test and the bidirectional shearing unit. A series arrangement of the gratings offers an on-axis geometry, which minimizes the systematic errors of the test. For illumination, an extended incoherent monochromatic light source is used. High-contrast fringes can be obtained by tailoring the degree of coherence via a periodic intensity distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light absorption from particulate impurities in snow and ice determined by spectrophotometric analysis of filters

Light absorption by particulate impurities in snow and ice can affect the surface albedo and is important for the climate. The absorption properties of these particles can be determined by collecting and melting snow samples and extracting the particulate material by filtration of the meltwater. This paper describes the optical design and testing of a new instrument to measure the absorption spectrum from 400 to 750 nm wavelength of the particles collected on filters using an ''integrating-sandwich'' configuration. The measured absorption is shown to be unaffected by scattering of light from the deposited particulates. A set of calibration standards is used to derive an upper limit for the concentration of black carbon (BC) in the snow. The wavelength dependence of the absorption spectra from 450 to 600 nm is used to calculate an absorption Angstrom exponent for the aerosol. This exponent is used to estimate the actual BC concentration in the snow samples as well as the relative contributions of BC and non-BC constituents to the absorption of solar radiation integrated over the wavelength band 300 to 750 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of the high harmonic generation spectra by changing the molecule-laser field relative orientation

The time dependent Schroedinger equation of a homonuclear diatomic molecule in the presence of a linearly polarized laser field is numerically solved by means of a split-operator parallel code. The calculations are carried out by assuming a single active electron model with fixed nuclei; a simplified two-dimensional model of the system is used. The highly nonlinear response of the electron wave function to the laser electric field stimulates the molecule to emit electromagnetic radiation consisting of a wide plateau of odd harmonics of the laser field. It is shown that the emitted spectrum can be finely controlled by changing the angle between the laser electric field and the molecular axis; this can be used to achieve a tunable source of high frequency radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electromagnetic material changes for remote detection and monitoring: a feasibility study: Progress report

A new concept for radiation detection is proposed, allowing a decoupling of the sensing medium and the readout. An electromagnetic material, such as a magnetic ceramic ferrite, is placed near a source to be tracked such as a shipping container. The electromagnetic material changes its properties, in this case its magnetic permeability, as a function of radiation. This change is evident as a change in reflection frequency and magnitude when probed using a microwave/millimeter-wave source. This brief report discusses modeling of radiation interaction of various candidate materials using a radiation detector modeling code Geant4, system design considerations for the remote readout, and some theory of the material interaction physics. The theory of radiation change in doped magnetic insulator ferrites such as yttrium iron garnet (YIG) seems well founded based on literature documentation of the photomagnetic effect. The literature also suggests sensitivity of permittivity to neutrons in some ferroelectrics. Research to date indicates that experimental demonstration of these effects in the context of radiation detection is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ULTRAVIOLET SPECTROSCOPY OF BL Hyi AND EF Eri IN HIGH AND INTERMEDIATE STATES

We present the first phase-resolved ultraviolet spectroscopy of two polar systems, BL Hyi and EF Eri, in high and intermediate states from the International Ultraviolet Explorer ( IUE ) during the periods between 1982–1995 and 1979–1991, respectively. The flux curves for the C iv and He ii emission lines for both systems showing variations in their fluxes at different orbital phases are presented. The emission lines are produced in the accretion stream. The reddening for the two polars is found to be 0.00. Our results show that there are variations of the line fluxes with time, similar to the light curves found for both BL Hyi and EF Eri in the optical, infrared, ultraviolet, and X-ray bands. IUE observations support a radiative shock model of BL Hyi with the heating of matter by radiation from the accretion shock and cooling by the electrons scattering off ultraviolet photons from the surface of the white dwarf. EF Eri observations support a two-temperature white dwarf model producing sufficient ultraviolet flux for orbital modulations.

79 ASTRONOMY AND ASTROPHYSICS↗

GW LIBRAE: STILL HOT EIGHT YEARS POST-OUTBURST

We report continued Hubble Space Telescope ( HST ) ultraviolet spectra and ground-based optical photometry and spectroscopy of GW Librae eight years after its largest known dwarf nova outburst in 2007. This represents the longest cooling timescale measured for any dwarf nova. The spectra reveal that the white dwarf still remains about 3000 K hotter than its quiescent value. Both ultraviolet and optical light curves show a short period of 364–373 s, similar to one of the non-radial pulsation periods present for years prior to the outburst, and with a similar large UV/optical amplitude ratio. A large modulation at a period of 2 hr (also similar to that observed prior to outburst) is present in the optical data preceding and during the HST observations, but the satellite observation intervals did not cover the peaks of the optical modulation, and so it is not possible to determine its corresponding UV amplitude. The similarity of the short and long periods to quiescent values implies that the pulsating, fast spinning white dwarf in GW Lib may finally be nearing its quiescent configuration.

79 ASTRONOMY AND ASTROPHYSICS↗

OPACITY MEASUREMENT AND THEORETICAL INVESTIGATION OF HOT SILICON PLASMA

We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm{sup −3} in the photon energy range of 1790–1880 eV. A 23 μg cm{sup −2} Si foil tamped by 50 μg cm{sup −2} CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s − 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.

79 ASTRONOMY AND ASTROPHYSICS↗

HEATING OF THE WARM IONIZED MEDIUM BY LOW-ENERGY COSMIC RAYS

In light of evidence for a high ionization rate due to low-energy cosmic rays (LECR) in diffuse molecular gas in the solar neighborhood, we evaluate their heat input to the warm ionized medium (WIM). LECR are much more effective at heating plasma than they are at heating neutrals. We show that the upper end of the measured ionization rates corresponds to a local LECR heating rate sufficient to maintain the WIM against radiative cooling, independent of the nature of the ionizing particles or the detailed shape of their spectrum. Elsewhere in the Galaxy the LECR heating rates may be higher than those measured locally. In particular, higher fluxes of LECR have been suggested for the inner Galactic disk, based on the observed hard X-ray emission, with correspondingly larger heating rates implied for the WIM. We conclude that LECR play an important and perhaps dominant role in the thermal balance of the WIM.

79 ASTRONOMY AND ASTROPHYSICS↗

Jet signatures in the spectra of accreting black holes

Jets are observed as radio emission in active galactic nuclei and during the low/hard state in X-ray binaries (XRBs), but their contribution at higher frequencies has been uncertain. We study the dynamics of jets in XRBs using the general-relativistic magnetohydrodynamic code HARM. We calculate the high-energy spectra and variability properties using a general-relativistic radiative transport code based on grmonty. We find the following signatures of jet emission: (i) a significant γ-ray peak above ∼10{sup 22} Hz, (ii) a break in the optical/UV spectrum, with a change from νL{sub ν}∼ν{sup 0} to νL{sub ν}∼ν, followed by another break at higher frequencies where the spectrum roughly returns to νL{sub ν}∼ν{sup 0}, and (iii) a pronounced synchrotron peak near or below ∼10{sup 14} Hz indicates that a significant fraction of any observed X-ray emission originates in the jet. We investigate the variability during a large-scale magnetic field inversion in which the Blandford–Znajek (BZ) jet is quenched and a new transient hot reconnecting plasmoid is launched by the reconnecting field. The ratio of the γ-rays to X-rays changes from L{sub γ}/L{sub X}>1 in the BZ jet to L{sub γ}/L{sub X}<1 during the launching of the transient plasmoid.

79 ASTRONOMY AND ASTROPHYSICS↗

WATER ICE AT THE SURFACE OF THE HD 100546 DISK

We made near-infrared multicolor imaging observations of a disk around Herbig Be star HD 100546 using Gemini/NICI. K (2.2 μm), H{sub 2}O ice (3.06 μm), and L′ (3.8 μm) disk images were obtained and we found a 3.1 μm absorption feature in the scattered light spectrum, likely due to water ice grains at the disk surface. We compared the observed depth of the ice absorption feature with the disk model based on Oka et al., including the water ice photodesorption effect by stellar UV photons. The observed absorption depth can be explained by both the disk models with and without the photodesorption effect within the measurement accuracy, but the model with photodesorption effects is slightly more favored, implying that the UV photons play an important role in the survival/destruction of ice grains at the Herbig Ae/Be disk surface. Further improvement to the accuracy of the observations of the water ice absorption depth is needed to constrain the disk models.

79 ASTRONOMY AND ASTROPHYSICS↗