Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A point implicit time integration technique for slow transient flow problems

We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation of explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust.

42 ENGINEERING↗

The rate of extreme coronal line emitters in the Baryon Oscillation Spectroscopic Survey LOWZ sample

Extreme coronal line emitters (ECLEs) are a rare class of galaxy that exhibit strong, high-ionization iron coronal emission lines in their spectra. In some cases, these lines are transient and may be the result of tidal disruption event (TDEs). To test this connection, we calculate the rate of variable ECLEs (vECLEs) at redshift $\sim 0.3$. We search for ECLEs in the Baryon Oscillation Spectroscopic Survey (BOSS) LOWZ sample and discover two candidate ECLEs. Using follow-up spectra from the Dark Energy Spectroscopic Instrument and Gemini Multi-Object Spectrograph, and mid-infrared observations from the Wide-field Infrared Survey Explorer, we determine that one of these galaxies is a vECLE. Using this galaxy, we calculate the galaxy-normalized vECLE rate at redshift $\sim 0.3$ to be $R_\mathrm{G}=1.6~^{+3.8}_{-1.4}\times 10^{-6}~\mathrm{galaxy}^{-1}~\mathrm{yr}^{-1}$and the mass-normalized rate to be $R_\mathrm{M}=7~^{+16}_{-6}\times 10^{-18}~\mathrm{M_\odot ^{-1}}~\mathrm{yr}^{-1}$. This is then converted to a volumetric rate of $R_\mathrm{V}=1.8~^{+4.5}_{-1.5}\times 10^{-9}~\mathrm{Mpc}^{-3}~\mathrm{yr}^{-1}$. Formally, the LOWZ vECLE rates are $2 \!-\! 4$ times lower than the rates calculated from the Sloan Digital Sky Survey Legacy sample at redshift $\sim 0.1$. However, given the large uncertainties on both measurements, they are consistent with each other at $1\sigma$. Both the galaxy-normalized and volumetric rates are one to two orders of magnitude lower than TDE rates from the literature, consistent with vECLEs being caused by $5 \!-\! 20$ per cent of all TDEs.

79 ASTRONOMY AND ASTROPHYSICS↗

Behavior of fuel with zirconium alloy cladding in reactivity-initiated accident and loss-of-coolant accident - 2016-0090

Along with our colleagues at the Japan Atomic Energy Research Institute (JAERI) and Japan Atomic Energy Agency (JAEA), we have performed extensive research programs for more than 2 decades and have developed a better understanding of fuel behavior under accident conditions. Data and findings from these research programs have provided the technical basis directly and indirectly for regulatory criteria in Japan and other countries. This paper reviews and summarizes the major outcomes from the research programs performed at JAERI and JAEA facilities and identifies further research needs. The programs aim to generate data and models to (1) evaluate the adequacy of present safety criteria and safety margins; (2) create a database for the future regulation of higher-burnup UO{sub 2} and mixed-oxide (MOX) fuels, new cladding, and pellets; (3) provide adequately mechanistic computer codes for regulatory application; (4) promote a better understanding of phenomena that appear in high-burnup regions and MOX fuels, such as rim effect and an effect of plutonium agglomerates in MOX fuels, and to evaluate those effects on fuel behavior in accident conditions; and (5) to assess fuel behaviors with higher fuel duty, such as plant power uprates, longer operating cycles, and water chemistry changes. The programs comprise reactivity-initiated accident studies, including pulse-irradiation experiments in the Nuclear Safety Research Reactor, cladding mechanical tests, and the development and verification of RANNS; loss-of-coolant accident tests, including integral thermal shock tests, oxidation rate measurements, and cladding mechanical tests; development and verification of a computer code FEMAXI-6 that simulates high-burnup fuel behavior under normal operating and abnormal transient conditions; and studies on phenomena specific to high-burnup regions, including thermal property measurements, experimental and analytical simulation of rim structure formation, cladding mechanical tests on effects of hydrides, etc. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study on Reactor Physical Module Method Used in THR Simulator

In order to apply heat in winter 5 MW low temperature nuclear test heating reactor (THR) was designed by Institute of nuclear and new energy technology, Tsinghua University, China. This test reactor is a model for the large-scale nuclear heating reactor (NHR). The primary loop in NHR is integrated nature circulation. Integrated nature circulation improved the safety of the reactor. Under the serious environment problem, the nuclear heat is one of the means of solving the pollution problem in China. So, the study on NHR comes to be important and necessary. The simulator is a good tool to study the transient status and understand the feature in a reactor. There were many studies on the NHR simulator but the point physical model was always selected before. The aim of the work in this paper is to build three dimension reactor physical module which can be used in THR simulator. It is the base for the study on NHR simulator.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamics and Control of Microgrids as a Resiliency Source

Microgrids can be operated in a utility-connected mode with the neighboring distribution system or in an islanded mode in separation with the distribution system. As the major disasters occur more and more often, islanded microgrid is proposed as a possible solution to serve essential loads until the utility service is restored. This paper evaluates the feasibility of using microgrids as a resiliency resource by a field test. A control scheme, integrating droop control and feedback control, is applied on a modified IEEE 13-node test feeders. The simulation results validate the proposed control scheme and the transient stability

Lee, Lung-An↗

On the shear-current effect: toward understanding why theories and simulations have mutually and separately conflicted

ABSTRACT The shear-current effect (SCE) of mean-field dynamo theory refers to the combination of a shear flow and a turbulent coefficient β21 with a favourable negative sign for exponential mean-field growth, rather than positive for diffusion. There have been long-standing disagreements among theoretical calculations and comparisons of theory with numerical experiments as to the sign of kinetic ($\beta ^u_{21}$) and magnetic ($\beta ^b_{21}$) contributions. To resolve these discrepancies, we combine an analytical approach with simulations, and show that unlike $\beta ^b_{21}$, the kinetic SCE $\beta ^u_{21}$ has a strong dependence on the kinetic energy spectral index and can transit from positive to negative values at $\mathcal {O}(10)$ Reynolds numbers if the spectrum is not too steep. Conversely, $\beta ^b_{21}$ is always negative regardless of the spectral index and Reynolds numbers. For very steep energy spectra, the positive $\beta ^u_{21}$ can dominate even at energy equipartition urms ≃ brms, resulting in a positive total β21 even though $\beta ^b_{21}\lt 0$. Our findings bridge the gap between the seemingly contradictory results from the second-order-correlation approximation versus the spectral-τ closure, for which opposite signs for $\beta ^u_{21}$ have been reported, with the same sign for $\beta ^b_{21}\lt 0$. The results also offer an explanation for the simulations that find $\beta ^u_{21}\gt 0$ and an inconclusive overall sign of β21 for $\mathcal {O}(10)$ Reynolds numbers. The transient behaviour of $\beta ^u_{21}$ is demonstrated using the kinematic test-field method. We compute dynamo growth rates for cases with or without rotation, and discuss opportunities for further work.

79 ASTRONOMY AND ASTROPHYSICS↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

US Contributions to the Athena Wide Field Imager

The world's premier X-ray astronomical observatories, Chandra and XMM-Newton, have been operating for about 20 years. The next flagship X-ray observatory launched will be ESA's Athena mission. We discuss planned US contributions to the Athena Wide Field Imager instrument, which encompass transient source detection, background characterization and reduction, and detector electronics design and testing, in addition to scientific contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rainier Mesa/Shoshone Mountain CAU Technical Basis Agreement Document: Hydrologic Source Term

The Hydrologic Source Term (HST) represents the transient release of residual radioactivity into groundwater associated with an underground nuclear test. An HST model seeks to quantitatively calculate these releases from a mathematical representation of release processes and physical and chemical data related to the test and the altered test environment. The development of an HST model requires a phenomenological understanding of underground detonation effects and their role in altering the physical and chemical environment surrounding a test, an estimate of the abundance, physical form, and spatial distribution of radioactivity in the post-test environment – the radiologic source term (RST), and consideration of mechanisms and processes that serve to transfer radioactive compounds into groundwater following a detonation. Simplified representations of the HST model are required for use in populating individual source regions in larger scale models of groundwater flow and contaminant transport within the sub CAU and CAU scale models. By necessity, such models must abstract and generalize many of the complicated release mechanisms over the large number of tests encountered in the CAU.

54 ENVIRONMENTAL SCIENCES↗

Advanced Supercritical Carbon Dioxide Brayton Cycle Development

Fluids operating in the supercritical state have promising characteristics for future high efficiency power cycles. In order to develop power cycles using supercritical fluids, it is necessary to understand the flow characteristics of fluids under both supercritical and two-phase conditions. In this study, a Computational Fluid Dynamic (CFD) methodology was developed for supercritical fluids flowing through complex geometries. A real fluid property module was implemented to provide properties for different supercritical fluids. However, in each simulation case, there is only one species of fluid. As a result, the fluid property module provides properties for either supercritical CO 2 (S-CO 2 ) or supercritical water (SCW). The Homogeneous Equilibrium Model (HEM) was employed to model the two-phase flow. HEM assumes two phases have same velocity, pressure, and temperature, making it only applicable for the dilute dispersed two-phase flow situation. Three example geometries, including orifices, labyrinth seals, and valves, were used to validate this methodology with experimental data. For the first geometry, S-CO 2 and SCW flowing through orifices were simulated and compared with experimental data. The maximum difference between the mass flow rate predictions and experimental measurements is less than 5%. This is a significant improvement as previous works can only guarantee 10% error. In this research, several efforts were made to help this improvement. First, an accurate real fluid module was used to provide properties. Second, the upstream condition was determined by pressure and density, which determines supercritical states more precise than using pressure and temperature. For the second geometry, the flow through labyrinth seals was studied. After a successful validation, parametric studies were performed to study geometric effects on the leakage rate. Based on these parametric studies, an optimum design strategy for the see-through labyrinth seals was proposed. A stepped labyrinth seal, which mimics the behavior of the labyrinth seal used in the Sandia National Laboratory (SNL) S-CO 2 Brayton cycle, was also tested in the experiment along with simulations performed. The rest of this study demonstrates the difference of valves' behavior under supercritical fluid and normal fluid conditions. A small-scale valve was tested in the experiment facility using S-CO 2 . Different percentages of opening valves were tested, and the measured mass flow rate agreed with simulation predictions. Two transients from a real S-CO 2 Brayton cycle design provided the data for valve selection. The selected valve was studied using numerical simulation, as experimental data is not available.

42 ENGINEERING↗

Systems Level Regulation of Rhythmic Growth Rate and Biomass Accumulation in Grasses

Objectives: Several breakthroughs have been recently made in our understanding of plant growth and biomass accumulation. It was found that plant growth is rhythmically controlled throughout the day by the circadian clock through a complex interplay of light and phytohormone signaling pathways. While plants such as the C4 energy crop sorghum (Sorghum bicolor (L.) Moench) and possibly the C3 grass Brachypodium distachyon also exhibit daily rhythms in growth rate, the molecular details of its regulation remain to be explored. A better understanding of diurnally regulated growth behavior in grasses may lead to species-specific mechanisms highly relevant to future strategies to optimize energy crop biomass yield. Here we propose to devise a systems approach to identify, in parallel, regulatory hubs associated with rhythmic growth in C3 and C4 plants. We propose to use rhythmicity in daily growth patterns to drive the discovery of regulatory network modules controlling biomass accumulation. Description: The project is divided in three main parts: 1) Performing time-lapse imaging and growth measurement in B. distachyon and S. bicolor to determine growth rate dynamic during the day/night cycle. Identifying growth-associated genes whose expression patterns follow the observed growth dynamics using deep sequencing technology, 2) identifying regulators of these genes by screening for DNA-binding proteins interacting with the growth-associated gene promoters identified in Aim 1. Screens will be performed using a validated yeast-one hybrid strategy paired with a specifically designed B. distachyon and S. bicolor transcription factor libraries (1000 clones each), and 3) Selecting 50 potential growth regulators from the screen for downstream characterization. The selection will be made by using a sytems biology approach by calculating the connectivity between growth rate, rhythmic gene expression profiles and TF expression profile and determine which TF is likely part of a hub and a potential regulator of plant growth. We will confirme the 50 DNA-protein interactions using transient transcriptional assays in B. distachyon and S. bicolor, and perform further testing in vivo by measuring growth parameters in transgenic loss- or gain-of-function lines for the selected transcription factors (25 B. distachyon and 3 S. bicolor lines). In 2016 the Principal Investigator relocated the laboratory to The Scripps Research Institute (TSRI) where the project has continued with an end date of 08/31/17. Accomplishments: We successfully collected large datasets of gene expression form the model grass Brachypodium. We used and developed bioinformatics analysis tools to investigate the structure, dynamics and robustness of circadian regulated gene expression in Brachypodium. Relevant Discoveries: We were able to determine that the endogenous circadian clock appears to play a much more subdued role in growth regulation in Brachypodium, that has been demonstrated in either Arabidopsis, or crop plants like Rice, Corn and Soybean. This led to our conclusion that Brachypodium unfortunately is unlikely to serve as an informative model for understanding how growth regulation in plants is under the control of circadian network circuitry. However, we were able to leverage our datasets in Brachypodium to inform us and reinforce a large collaborative study on gene networks governing cell wall deposition in Arabidopsis. This led to a major and highly cited publication relevant to improving biomass production.

09 BIOMASS FUELS↗

Status of SAS4A/SASSYS Code Developments (FY2018)

SAS4A/SASSYS is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. [1] With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for nearly fifty years. It has been identified as a critical element of safety analysis capabilities for the U.S. Department of Energy, [2] and it will be used to perform the transient safety analysis required to support the authorization basis for the Versatile Test Reactor (VTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmarking Of Improved DPAC Transient Deflagration Analysis Code

The transient deflagration code DPAC (Deflagration Pressure Analysis Code) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak deflagration pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vessel walls. In addition, DPAC has been coupled with CEA, a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. The improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Phenix end-of-life natural convection test with SAS4A/SASSYS-1

From a reduced power and flow condition, the 2009 Phenix Natural Convection Test mimics a protected loss-of-heat sink event. The measured transient response of the Phenix reactor to such an event provides an important data set for validating safety analysis codes. A model of the Phenix reactor and primary coolant system was developed using the reactor safety analysis code system SAS4A/SASSYS-1. While the overall global response of the reactor was predicted reasonably well, there were some non-negligible discrepancies in the temperature predictions during the transient and work continues to improve the model. Some modeling issues have been identified, and will be addressed as improvements to the model continue. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗