Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Probing the Location and Speciation of Elements in Zeolites with Correlated Atom Probe Tomography and Scanning Transmission X-Ray Microscopy

Characterizing materials at nanoscale resolution to provide new insights into structure property performance relationships continues to be a challenging research target due to the inherently low signal from small sample volumes, and is even more difficult for nonconductive materials, such as zeolites. Thus, we present the characterization of a single Cu-exchanged zeolite crystal, namely Cu-SSZ-13, used for NO X reduction in automotive emissions, that was subject to a simulated 135,000-mile aging. By correlating Atom Probe Tomography (APT), a single atom microscopy method, and Scanning Transmission X-ray Microscopy (STXM), which produces high spatial resolution X-ray Absorption Near Edge Spectroscopy (XANES) maps, we show that a spatially non-uniform proportion of the Al was removed from the zeolite framework. Here, the techniques reveal that this degradation is heterogeneous at length scales from micrometers to tens of nanometers, providing complementary insight into the long-term deactivation of this catalyst system.

36 MATERIALS SCIENCE↗

Micro‐ and Nanoscale Heterogeneities in Zeolite Beta as Measured by Atom Probe Tomography and Confocal Fluorescence Microscopy

Micro- and nanoscale information on the activating and deactivating coking behaviour of zeolite catalyst materials increases our current understanding of many industrially applied processes, such as the methanol-to-hydrocarbon (MTH) reaction. Atom probe tomography (APT) was used to reveal the link between framework and coke elemental distributions in 3D with sub-nanometre resolution. APT revealed 10–20 nanometre-sized Al-rich regions and short-range ordering (within nanometres) between Al atoms. With confocal fluorescence microscopy, it was found that the morphology of the zeolite crystal as well as the secondary mesoporous structures have a great effect on the microscale coke distribution throughout individual zeolite crystals over time. Additionally, a nanoscale heterogeneous distribution of carbon as residue from the MTH reaction was determined with carbon-rich areas of tens of nanometres within the zeolite crystals. Finally, a short length-scale affinity between C and Al atoms, as revealed by APT, indicates the formation of carbon-containing molecules next to the acidic sites in the zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

Effect of hydration on morphology of thin phosphonate block copolymer electrolyte membranes studied by electron tomography

The morphological changes of phosphonate polypeptoid electrolyte membranes, poly-N-(2-ethyl)hexylglycine-block-poly-N-phosphonomethylglycine (pNeh m -b-pNpm n ), in hydrated and dry states were characterized by cryogenic transmission electron microscopy (cryo-TEM) and cryogenic electron tomography (cryo-ET). The analysis of 3D tomograms revealed that the pNeh 9 -b-pNpm 9 thin films absorbed a large amount of water, resulting in the formation of membranes that were nearly flat and giant multicompartment vesicles dispersed in the water phase. A simple lamellar phase appeared when the films were dried. In contrast, pNeh 18 -b-pNpm 18 thin films absorbed little water and formed small highly curved unilamellar and multilamellar vesicles. Water was located mainly outside the closely-packed vesicles. When water was removed by drying, the walls of adjacent vesicles collapsed to form honeycomb-like capsules. Here, the changes in domain size reflected changes in chain conformations. The pNpm9 blocks were saturated by water and fully extended, while pNpm 18 blocks were neither saturated by water nor fully extended. In addition, the thicknesses of hydrophobic blocks in the hydrated films of both pNeh 9 -b-pNpm 9 and pNeh 18 -b-pNpm 18 were smaller than those in the dry films, reflecting an increase of the average distance between the neighboring junctions of polypeptoid molecules.

36 MATERIALS SCIENCE↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging high stage river-water intrusion into a contaminated aquifer along a major river corridor using 2D time-lapse surface electrical resistivity tomography

The Hanford 300 Area is located adjacent to the Columbia River in south-central Washington State, USA, and was a former site for nuclear fuel processing operations. Waste disposal practices resulted in persistent unsaturated zone and groundwater contamination, the primary contaminant of concern being uranium. Uranium behavior at the site is intimately linked with river stage driven groundwater-river water exchange such that understanding the nature of river water intrusion into the 300 Area is critical for predicting uranium desorption and transport. In this paper we use time-lapse electrical resistivity tomography (ERT) to image the inland intrusion of river during high stage conditions. We demonstrate a modified time-lapse inversion approach, whereby the transient water table elevation is explicitly modeled by removing regularization constraints across the water table boundary. This implementation was critical for producing meaningful imaging results. We inverted approximately 1200 data sets (400 per line over 3 lines) using high performance computing resources to produce a time-lapse sequence of changes in bulk conductivity caused by river water intrusion during the 2011 spring runoff cycle over approximately 125 days. The resulting time series for each mesh element was then analyzed using common time series analysis to reveal the timing and location of river water intrusion beneath each line. The results reveal non-uniform flows characterized by preferred flow zones where river water enters and exits quickly with stage increase and decrease, and low permeability zones with broader bulk conductivity ‘break through’ curves and longer river water residence times. The time-lapse ERT inversion approach removes the deleterious effects of changing water table elevation and enables remote and spatial continuous groundwater-river water exchange monitoring using surface based ERT arrays under conditions where groundwater and river water conductivity are in contrast.

300 Area↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

X-ray computed tomography of wood-adhesive bondlines: Attenuation and phase-contrast effects

Microscale X-ray computed tomography (XCT) is discussed as a technique for identifying 3D adhesive distribution in wood-adhesive bondlines. Visualization and material segmentation of the adhesives from the surrounding cellular structures require sufficient gray-scale contrast in the reconstructed XCT data. Commercial wood-adhesive polymers have similar chemical characteristics and density to wood cell wall polymers and therefore do not provide good XCT attenuation contrast in their native form. Here, three different adhesive types, namely phenol formaldehyde, polymeric diphenylmethane diisocyanate, and a hybrid polyvinyl acetate, are tagged with iodine such that they yield sufficient X-ray attenuation contrast. However, phase-contrast effects at material edges complicate image quality and segmentation in XCT data reconstructed with conventional filtered backprojection absorption contrast algorithms. A quantitative phase retrieval algorithm, which isolates and removes the phase-contrast effect, was demonstrated. The paper discusses and illustrates the balance between material X-ray attenuation and phase-contrast effects in all quantitative XCT analyses of wood-adhesive bondlines.

36 MATERIALS SCIENCE↗

What the radiologist needs to know: the role of preoperative computed tomography in selection of operative approach for adrenalectomy and review of operative techniques

Adrenalectomy is the standard of care for management of many adrenal tumor types and, in the United States alone, approximately 6000 adrenal surgeries are performed annually. Two general approaches to adrenalectomy have been described; (1) the open approach, in which a diseased adrenal is removed through a large (10–20 cm) abdominal wall incision, and (2) the minimally invasive approach, in which laparoscopy is used to excise the gland through incisions generally no longer than 1–2 cm. Given these disparate technique options, clear preoperative characterization of those specific disease features that inform selection of adrenalectomy approach is critically important to the surgeon. Because most of these features are directly assessed via preoperative abdominal imaging, in particular computed tomography (CT) scanning, a clear mutual understanding among surgeons and radiologists of those adrenal tumor features impacting operative approach selection is vital for planning adrenal surgery. In this context, we review the preoperative CT imaging features that specifically inform adrenalectomy approach selection, provide illustrative examples from our institution’s imaging and surgical archives, and provide a stepwise guide to both the open and laparoscopic adrenalectomy approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the frequency and severity of ovarian venous congestion on adult computed tomography

Purpose: While pelvic congestion syndrome and chronic pelvic pain are relatively common in women, no large- or medium-sized studies have been conducted to our knowledge to evaluate the frequency and severity of ovarian vein dilatation (OVD) on computed tomography (CT). The purpose of our study was therefore to analyze a large number of consecutive abdominal and pelvic CT scans in adult women to determine OVD frequency and severity. Methods: An IRB-approved, single-institution retrospective analysis of 1042 consecutive abdominal and pelvic CT scans in women ages 25–65 was performed. Scans were evaluated for the presence and severity of OVD and association with “nutcracker anatomy.” A gradation scheme was developed based on quartile analysis. Results: 143 of the CT scans had OVD (13.7%). Of the positive scans, 96 were bilateral, 29 were left-side only, 18 were right-side only, and 18 had nutcracker-type compression of the left renal vein (14.4% of scans with left or bilateral OVD). In positive scans, the mean and median left OVD were 7.5 and 7 mm, respectively, and right-side were 7.2 and 7 mm, respectively. Based on quartile analysis, OVD grading was mild (< 6 mm), moderate (6–8 mm), or severe (> 8 mm), with moderate including the middle 50% of patients. Conclusions: OVD was found on 13.7% of 1042 consecutive female abdominal and pelvic CT scans, with “nutcracker anatomy” present in 14.4% of the scans with left OVD. Moderate dilatation was defined as an OVD of 6–8 mm at the iliac crests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of hepatic abscess from metastasis on contrast-enhanced dynamic computed tomography in patients with a history of extrahepatic malignancy: emphasis on dynamic change of arterial rim enhancement

Objectives: The objective of the study is to identify computed tomography (CT) findings that differentiate hepatic abscess from hepatic metastasis in a patient with a history of extrahepatic malignancy. Materials and methods: This retrospective study included 30 patients with 93 hepatic abscesses and 40 patients with 125 hepatic metastases who had a history of extrahepatic malignancy and underwent contrast-enhanced dynamic CT with arterial phase (AP) and portal venous phase (PVP). The diagnosis of hepatic abscess and hepatic metastasis was made using pathological confirmation or clinical diagnosis. Margin, patchy parenchymal enhancement, arterial rim enhancement, dynamic change of arterial rim enhancement, size discrepancy of lesions between arterial and portal phases, bile duct dilatation, perilesional hyperemia, and perilesional low density were evaluated by two radiologists independently. Significant findings for differentiating two groups were identified at univariate and multivariate analysis with nomogram for predicting hepatic abscess. Interobserver agreement was also analyzed for each variable. Results: Multivariate analysis revealed that patchy parenchymal enhancement (P < 0.001), arterial rim enhancement persistent through PVP (P < 0.001), and perilesional hyperemia (P = 0.013) were independent significant findings to predict hepatic abscess than metastasis. Among them, arterial rim enhancement persistent through PVP showed a highest odds ratio (OR 33.73) on multivariate analysis and a highest predictor point on a nomogram for predicting hepatic abscess. When two of these three criteria were combined, 80.7% (75/93) of hepatic abscess were correctly identified, with a specificity of 85.6% (107/125). When all three criteria were satisfied, specificity was up to 100% (125/125). Conclusions: At contrast-enhanced dynamic CT, patchy parenchymal enhancement, arterial rim enhancement persistent through PVP, perilesional hyperemia, and their combinations may be reliable CT features for differentiating hepatic abscess from metastasis in patients with a history of primary extrahepatic malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal solitary fibrous tumor/hemangiopericytoma: computed tomography findings and clinicopathologic features

Purpose: To retrospectively characterize the clinical, pathological, and computed tomography (CT) findings of renal solitary fibrous tumor/hemangiopericytoma (rSFT/HPC). Methods: Twelve patients with rSFT/HPCs were enrolled. The CT findings and clinicopathological features were retrospectively reviewed. Results: This study included six male and six female patients (median age: 47; age range: 20–82 years). Eight benign (grade I) and four malignant (grade III) rSFT/HPCs were identified. Of the 12 lesions, 10 were in the renal sinus near the renal pelvis, while two replaced the whole kidney. Five lesions were well-defined, five were partially ill-defined, and two were ill-defined. Mild (5/12) and intermediate (1/12) hydronephrosis was observed. On the unenhanced CT images, ten tumors showed slightly higher density when compared to the normal renal parenchyma, and two masses were isodense to hypodense. After intravenous contrast medium injection, three enhancement patterns were observed, including “prolonged enhancement” (PE) (6/12), “gradual enhancement” (4/12), and “early washout” (2/12). A central fibrous scar was found in five patients. Compared to the grade I lesions, the grade III rSFT/HPC lesions tended to be larger (maximal diameter > 10 cm) and more heterogeneous with a higher incidence of the PE pattern. Conclusions: We have shown that rSFT/HPCs usually arise from the renal sinus, and present as lobulated, slightly hyperdense, gradually enhancing soft tissue masses. CT findings, including large size, heterogeneity, and the PE pattern, may assist in the pre-operative identification of malignant grade III rSFT/HPCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of duodenal gastrointestinal stromal tumors from hypervascular pancreatic neuroendocrine tumors in the pancreatic head using contrast-enhanced computed tomography

Purpose: To determine useful contrast-enhanced computed tomography (CE-CT) features in differentiating duodenal gastrointestinal stromal tumors (duodenal GISTs) from hypervascular pancreatic neuroendocrine tumors in the pancreatic head (pancreatic head NETs). Methods: Seventeen patients with pathologically confirmed duodenal GISTs and 25 with pancreatic NETs underwent preoperative CE-CT. CT image analysis included tumor size, morphology, and contrast enhancement. Receiver operating characteristic curves were performed, and cutoff values were calculated to determine CT findings with high sensitivity and specificity. Results: CT imaging showed duodenal GISTs with higher frequencies of tumor central location close to the duodenum and a predominantly solid tumor type when compared with pancreatic head NETs (p < 0.05 for both). Duodenal GISTs were larger than pancreatic head NETs (3.3 ± 0.9 cm vs. 2.5 ± 1.1 cm, p = 0.03). Duodenal GISTs had significantly lower CT attenuation values (112.9 ± 17.9HU vs. 137.4 ± 32.1HU, p < 0.01) at the arterial phase and higher CT attenuation values at the delayed phase (94.3 ± 7.9HU vs. 84.9 ± 10.4HU, p < 0.01) when compared with pancreatic head NETs. A CT attenuation value of ≤ 135 HU at the arterial phase (30 s) was 76% sensitive, 94.1% specific, and 83.3% accurate for the diagnosis of duodenal GISTs, while a CT attenuation value of ≥ 89.5 HU at the delayed phase (120 s) was 93.3% sensitive, 81.8% specific, and 76.2% accurate for the diagnosis of duodenal GISTs. Conclusion: Tumor central location, size, texture, and contrast enhancement are valuable characteristics for the differentiation between duodenal GISTs and hypervascular pancreatic head NETs during preoperative examination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of biliary anatomy in the caudate lobe using drip infusion cholangiography-computed tomography

Purpose: This study aimed to retrospectively evaluate the caudate branches (CBs), which are bile ducts originating from the caudate lobe (CL), using drip infusion cholangiography with computed tomography (DIC-CT). Methods: The confluence patterns of CBs were evaluated in 185 adult patients undergoing DIC-CT. The following bile duct features were evaluated: (a) number of depicted CBs; (b) identification of the caudate portion from which the CBs were derived; (c) identification of the confluence site of a CB; and (d) whether there was a difference in the confluence site of the CBs depending on the position of the right posterior hepatic duct (RPHD) and the portal vein (PV). Results: DIC-CT enabled detection of a total of 640 bile ducts from the CL in 185 patients, and the total number of CBs from the Spiegel lobe (SP), the paracaval portion, and the caudate process (CP) were 347 (54.2%), 112 (17.5%), and 181 (28.2%), respectively. In the SP, over 60% of CBs joined the left hepatic duct system (LHDS). The positional relationship between the RPHD and the PV was divided into a supra-portal course (n = 168) and an infra-portal course (n = 17). The number of CBs joining the LHDS was significantly different between a supra-portal course and an infra-portal course (p = 0.0484). Conclusion: CBs were depicted by DIC-CT in 98.9% of the subjects, and a detailed evaluation was possible. The number of CBs joining the LHDS was associated with the position of the RPHD and the PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morphological predictors for lymph node metastases on computed tomography in colon cancer

Introduction/Background: The aim of the study was to assess morphological predictors for lymph node metastases (Stage III disease) in colon cancer on computed tomography. Methods and materials: Ninety-four patients with histology-proven colon cancer (adenocarcinoma) who underwent elective primary curative resection between the years 2012 and 2014 were included. Contrast-enhanced CT examinations were independently reviewed by two blinded observers regarding tumor location, depth of tumor invasion, and presence of lymph node metastases. Ocular presence of internal heterogeneity and presence of irregular outer border were used as morphological criteria for lymph node involvement. Protocol-based histopathology after curative surgery served as reference standard. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy for each morphological criterion for prediction of stage III disease were calculated. Inter-observer agreement was compared using Kappa statistics. Results: According to histopathology, 59 patients were staged as I–II disease and 35 patients were staged as stage III disease. The presence of internal heterogeneity in a lymph node on CT resulted in moderate sensitivity (66–77%) but high specificity (95–95%) for prediction of Stage III disease by both observers. The presence of irregular outer border also resulted in poor sensitivity (49–54%) but high specificity (97–97%). The combination of either internal heterogeneity and/or irregular outer border per patient resulted in a moderate sensitivity (67–77%) and high specificity (95–95%), PPV (89–96%), and NPV (84–88%). Inter-observer agreement (Cohens Kappa) was 0.72. Consensus reading for the combined criteria resulted in sensitivity and specificity of 69% and 100%, respectively. Conclusion: Using morphological criteria for lymph node metastases on CT examination in patients with colon cancer results in high specificity but moderate sensitivity in predicting stage III disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of aggressive from non-aggressive pancreatic solid pseudopapillary neoplasms using computed tomography

Purposes: Microscopic aggressive behaviors may be related with the prognosis of solid pseudopapillary neoplasms (SPNs). In this study, we investigate computed tomography (CT) features and differential diagnosis of aggressive and non-aggressive SPNs in pancreas. Materials and methods: 122 patients with pathologically proven SPNs in pancreas were included. Patients’ age, tumor site, texture, shape, margins, exophytic growth, capsule, calcification, hemorrhage, pancreatic duct dilatation or pancreatic parenchyma atrophy, peripancreatic infiltration or metastases, vascular encasement, and enhancement pattern were assessed. The diagnostic accuracy was analyzed by using the receiver operating characteristic curve (ROC). Results: There were 30 aggressive SPNs and 92 non-aggressive SPNs. Aggressive SPNs showed significantly higher frequencies of an ill-defined margin, patient age > 40.5 years, and tumor size < 42.1 mm, but lower frequencies of complete capsule, hemorrhage compared with non-aggressive SPNs (p < 0.05). Lack of complete capsule and age > 40.5 years were independent risk factors of aggressive SPNs (odd ratio 7.08 and 3.1, respectively). When we applied the two predictors in the logistic regression model, the area under the curve (AUC) was 0.77 with sensitivity of 86.7% and specificity of 55.4%. Conclusion: Size less than 42.1 mm, lack of complete capsule, ill-defined, and absent bleeding are useful CT imaging features for predicating aggressive SPNs. Patient age > 40.5 years and lack of complete capsule showed acceptable diagnostic performance for discriminating aggressive from non-aggressive SPNs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗