Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technique Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SISGR - In situ characterization and modeling of formation reactions under extreme heating rates in nanostructured multilayer foils

Materials subjected to extreme conditions, such as very rapid heating, behave differently than materials under more ordinary conditions. In this program we examined the effect of rapid heating on solid-state chemical reactions in metallic materials. One primary goal was to develop experimental techniques capable of observing these reactions, which can occur at heating rates in excess of one million degrees Celsius per second. One approach that we used is x-ray diffraction performed using microfocused x-ray beams and very fast x-ray detectors. A second approach is the use of a pulsed electron source for dynamic transmission electron microscopy. With these techniques we were able to observe how the heating rate affects the chemical reaction, from which we were able to discern general principles about how these reactions proceed. A second thrust of this program was to develop computational tools to help us understand and predict the reactions. From atomic-scale simulations were learned about the interdiffusion between different metals at high heating rates, and about how new crystalline phases form. A second class of computational models allow us to predict the shape of the reaction front that occurs in these materials, and to connect our understanding of interdiffusion from the atomistic simulations to measurements made in the laboratory. Both the experimental and computational techniques developed in this program are expected to be broadly applicable to a wider range of scientific problems than the intermetallic solid-state reactions studied here. For example, we have already begun using the x-ray techniques to study how materials respond to mechanical deformation at very high rates.

36 MATERIALS SCIENCE↗

SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a facility for the in situ measurement of catalytic reaction by neutron scattering spectroscopy

Catalysis is a critical enabling science for future energy needs. The next frontier of catalysis is to evolve from catalyst discovery to catalyst design, and for this next step to be realized, we must develop new techniques to better understand reaction mechanisms. To do this, we must connect catalytic reaction rates and selectivities to the kinetics, energetics, and dynamics of individual elementary steps and relate these to the structure and dynamics of the catalytic sites involved. Neutron scattering spectroscopies offer unique capabilities that are difficult or impossible to match by other techniques. Additionally, the current study presents the development of a compact and portable instrumental design that enables the in situ investigation of catalytic samples by neutron scattering techniques. The developed apparatus was tested at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory and includes a gas handling panel that allows for computer hookups to control the panel externally and online measurement equipment such as coupled GC-FID/TCD (Gas Chromatography-Flame Ionization Detector/Thermal Conductivity Detector) and MS (Mass Spectrometry) to characterize offgassing while the sample is in the neutron scattering spectrometer. This system is flexible, modular, compact, and portable enabling its use for many types of gas-solid and liquid-solid reactions at the various beamlines housed at the SNS.

47 OTHER INSTRUMENTATION↗

Probing Fundamental Mechanisms of Plastic Deformation with High Energy X-rays (Final Progress Report)

Overall, substantial progress was made on developing BCDI techniques in the direction of imaging defects in multi-crystal samples. Section 2.1 describes a new method to reconstruct the 3D atomic displacement field within a grain from multiple coherently resolved diffraction peaks. The key development is the ability to recover a best fit to the grain shape at the same time as the internal displacement (strain) variation with no prior knowledge of the microstructure. This is complemented by the development of a method, Sec. 2.2, to separate out sets of Laue reflections that belong to a single grain (and thus be able to index its orientation) in the commonly encountered situation in which the beam illuminates several grains in a given location. This is essential for enabling collection of coherent diffraction data (at APS 34-ID-C) from neighboring grains. All experiments depend on the quality of samples used. Although good progress has been made with thin film samples, we are working with a broader range of geometries. A new sample design uses a high-Z metal (e.g., Pt) deposited in a sub-micron trench in a low-Z metal (e.g., Al) so that the grain size is prevented from exceeding the current limit for BCDI. We also report in section 3.1 on successfully applying NF-HEDM to a fine-grain Mg sample that would normally be considered out of scope for the method. This represents progress towards being able to map out polycrystalline samples in 3D before performing BCDI on individual grains. We further report in section 3.2 on preliminary NF-HEDM characterization of a sample of UO2 that has sub-micron grains; the data imply the capability of mapping fine-grain polycrystals at 1-ID-E, again for the purposes of BCDI in the bulk. Lastly, our plan is to load grains in polycrystalline samples by inducing thermal stress. We also report the experimental measurements of the Ti- 6Al-4V alloy obtained at the European Synchrotron Radiation Facility (ESRF), which had been indexed and mapped via HEDM at APS in section 9. As discussed below, however, technique development pre-occupied the team throughout the project which meant that we did not make any significant progress towards answering the original hypotheses as stated in the proposal. In summary, we assert that we have made good progress in methods and samples and future work taking advantage of this progress is likely to obtain and analyze BCDI data from multiple adjacent grains in 3D polycrystals. Obtaining such data depends on re-gaining access to the Advanced Photon Source, which is anticipated in late summer or the Fall. In all cases, work has involved close collaboration with faculty, staff, postdocs and students from Brigham Young University (BYU), the Los Alamos National Laboratory and APS beamlines 1-ID and 34-ID.

36 MATERIALS SCIENCE↗

Developing 226 Ra and 227 Ac age-dating techniques for nuclear forensics to gain insight from concordant and non-concordant radiochronometers

The model age or ‘date of purification’ of a nuclear material is an important nuclear forensic signature. In this study, chemical separation and MC-ICP-MS measurement techniques were developed for 226 Ra and 227 Ac: grand-daughter nuclides in the 238 U and 235 U decay chains respectively. The 230 Th- 234 U, 226 Ra- 238 U, 231 Pa- 235 U, and 227 Ac- 235 U radiochronometers were used to calculate model ages for CRM-U100 standard reference material and two highly-enriched pieces of uranium metal from the International Technical Working Group Round Robin 3 Exercise. In conclusion, the results demonstrate the accuracy of the 226 Ra- 238 U and 227 Ac- 235 U chronometers and provide information about nuclide migration during uranium processing.

07 ISOTOPE AND RADIATION SOURCES↗

DEVELOPMENT OF IN SITU TECHNIQUES FOR TORSION AND TENSION TESTING IN HYDROGEN ENVIRONMENT

Reliability of hydrogen storage tanks is significantly influenced by the mechanical performance of the container materials in the hydrogen environment. Fracture behavior and fracture toughness are of specific interest since they are relevant to many catastrophic failures. However, many conventional fracture testing techniques are difficult to be realized under the presence of hydrogen. Thus it is desired to develop novel in situ techniques to study the fracture behavior of structural materials in hydrogen environments. In this study, special testing apparatus were designed to facilitate in situ fracture testing in H2. In addition to a multi-notch tensile fixture, a torsional fixture was developed to utilize an emerging fracture testing technique, Spiral Notch Torsion Test (SNTT). The design concepts will be discussed. Preliminary in situ testing results indicated that the presence of H2 significantly reduces the fracture toughness of 4340 pipeline steels by up to 50 percent. On the other hand, SNTT tests conducted in air demonstrated a significant fracture toughness reduction in samples subject to Gleeble heat treatment, which illustrated the effect of welding on the fracture toughness of this material.

08 HYDROGEN↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successes and Opportunities for Discovery of Metal Oxide Photoanodes for Solar Fuels Generators

We report that the importance of metal oxide photoanodes in solar fuels technology has garnered concerted efforts in photoanode discovery in recent decades, which complement parallel efforts in development of analytical techniques and optimization strategies using standard photoanodes such as TiO 2 , Fe 2 O 3 and BiVO 4 . Theoretical guidance of high-throughput experiments has been particularly effective in dramatically increasing the portfolio of metal oxide photoanodes, motivating a new era of photoanode development where the characterization and optimization techniques developed on traditional materials are applied to nascent photoanodes that exhibit visible light photoresponse. The compendium of metal oxide photoanodes presented in the present work can also serve as the basis for further technique development, with a primary goal to establish workflows for discovery of materials that perform better against the critical criteria of operational stability, visible light photoresponse, and photovoltage suitable for tandem absorber architectures.

14 SOLAR ENERGY↗

Generation of virtual monochromatic CBCT from dual kV/MV beam projections

Purpose: To develop a novel on-board imaging technique which allows generation of virtual monochromatic (VM) cone-beam CT (CBCT) with a selected energy from combined kilovoltage (kV)/megavoltage (MV) beam projections. Methods: With the current orthogonal kV/MV imaging hardware equipped in modern linear accelerators, both MV projections (from gantry angle of 0°–100°) and kV projections (90°–200°) were acquired as gantry rotated a total of 110°. A selected range of overlap projections between 90° to 100° were then decomposed into two material projections using experimentally determined parameters from orthogonally stacked aluminum and acrylic step-wedges. Given attenuation coefficients of aluminum and acrylic at a predetermined energy, one set of VM projections could be synthesized from two corresponding sets of decomposed projections. Two linear functions were generated using projection information at overlap angles to convert kV and MV projections at nonoverlap angles to approximate VM projections for CBCT reconstruction. The contrast-to-noise ratios (CNRs) were calculated for different inserts in VM CBCTs of a CatPhan phantom with various selected energies and compared with those in kV and MV CBCTs. The effect of overlap projection number on CNR was evaluated. Additionally, the effect of beam orientation was studied by scanning the CatPhan sandwiched with two 5 cm solid-water phantoms on both lateral sides and an electronic density phantom with two metal bolt inserts. Results: Proper selection of VM energy [30 and 40 keV for low-density polyethylene (LDPE), polymethylpentene, 2 MeV for Delrin] provided comparable or even better CNR results as compared with kV or MV CBCT. An increased number of overlap kV and MV projection demonstrated only marginal improvements of CNR for different inserts (with the exception of LDPE) and therefore one projection overlap was found to be sufficient for the CatPhan study. It was also evident that the optimal CBCT image quality was achieved when MV beams penetrated through the heavy attenuation direction of the object. Conclusions: A novel technique was developed to generate VM CBCTs from kV/MV projections. This technique has the potential to improve CNR at selected VM energies and to suppress artifacts at appropriate beam orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Background Radiation Using Geochemical Data

Aerial gamma ray surveys have many applications in geology and science in general, such as locating mining prospects, defining radioactive plumes, and detecting nuclear weapons. Unfortunately there is currently no simple way to separate the natural gamma radiation of soil and rocks from that of contaminants such as radioactive plumes. This project used geochemical data (uranium, potassium and thorium concentrations) collected from national databases, private companies, and the NURE (National Uranium Resource Evaluation) Survey, to create forward models of exposure rates measured by aerial gamma ray surveys. We developed these techniques using an area in north central Arizona known as the Navajo Mines area, chosen for its optimal conditions for aerial gamma ray surveys and readily available survey data. Models based on geochemical analyses from databases were not found to be successful, in part due to lack of data for some units. Models based on NURE data sorted by geologic unit were successful at replicating the aerial gamma ray survey, though units with Uranium mineralization proved difficult. ASTER visualizations were effectively used to create subunits of similar exposure rate within the Chinle Formation which contains multiple lithologies. For alluvial units, models based on drainage basin were attempted with success. With these models we are developing techniques to estimate the natural radiation generated by the rocks and soils of an area, making aerial ray surveys more effective.

58 GEOSCIENCES↗

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl{sub 4} and CHCl{sub 3} were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Stability evaluation and mitigation strategies in advanced tokamaks using 3D MHD spectroscopy

Multi-modal, active 3D MHD spectroscopy is applied in high-performance advanced tokamak scenarios to study their stability time evolution, revealing an intriguing dependence on both and . A tailored applied 3D field provides a 3D plasma response to extract the growth rate of the least stable mode. The estimated growth rate finds a decrease in stability when the minimum in the safety factor (q) passes through 2.0 and reveals inherent risks of crossing an additional rational surface at integer q min , even above the usual q = 1 sawtooth condition. Based on this result, the potential scenario in which q min ~ 2 can be safely crossed during a more stable lower β N phase was investigated, and the improved stability of this scenario is confirmed by the estimated growth rate. This shows that 3D MHD spectroscopy can offer insights into strategies for improving stability by identifying the vulnerable aspects of such scenarios. In addition, the method highlights its potential for instability avoidance by enabling early detection of multiple modes, even before magnetic coils can measure them. The measured growth rate by the 3D MHD spectroscopy shows its reliability by exhibiting a correlation with the programmed rises in plasma beta across various high β N and high q min discharges. In addition, this method is successfully applied during rapidly evolving I p ramp-up phases, a key part of the scenario development. By achieving reasonable growth rate measurements at high-performance scenario developments, this technique contributes to the development of advanced diagnostic tools for tokamak scenario stability, which will help identify an effective pathway to stable, high-performance scenarios.

Yang, S. M. [Princeton Plasma Physics Laboratory (↗

Zr Extrusion – Direct Input for Models & Validation

As we examine differences in the high strain rate, high strain tensile response of high purity, highly textured Zr as a function of loading direction, temperature and extrusion velocity with primarily post mortem characterization techniques, we have also developed a technique for characterizing the in-situ extrusion process. This particular measurement is useful for partitioning energy of the system during the extrusion process: friction, kinetic energy, and temperature

36 MATERIALS SCIENCE↗

Vapor-Particle Separation Using Microporous Metallic Membrane in Crossflow Filtration

Simultaneous separation of vapor and particles in industrial processes could be a key step toward manufacturing of high-quality goods. The separation is critical for successful measurement of volatile or semi-volatile aerosol particles, which no reliable technique exists. We have developed a technique for separation of vapor and particles simultaneously using a specialty microporous metallic membrane. The separator allows the thermally denuded particles traverse straight through the membrane tube, while the vapor molecules permeate through the membrane, separate from the particles and are removed subsequently. The separation technique virtually eliminates the possibility of contamination by vapor re- condensation. We tested the prototype of the vapor-particle separator (VPS) using aerosols prepared from sodium chloride to represent non-volatile aerosols. Chemical like dioctyl phthalate was chosen to represent volatile particles. The test aerosol particles were generated by an atomizer followed by a tandem differential mobility analyser to produce a stream of monodisperse particles in the size range of 10 to 100 nm. In real world particles, we tested the VPS using diesel engine particles that is a mixture of complex chemical composition. Number concentration of the nonvolatile particles reduced as the temperature increased, but the mode diameter of the aerosol population remained unchanged. Number concentration of the volatile particles was also reduced as the temperature increased, but their mode diameters became smaller as particles shrunk in diameter. Differences in the thermal behaviour of the particles were attributed to its transition energy barrier and evaporation rate. Mass balance analysis suggests the separation of vapor and test particles was reasonably complete. Thus, we conclude the VPS could provide an effective means for quantitative characterization of aerosol volatility and separation of vapors from particles.

aerosol↗

Instantaneous Three-Dimensional Temperature Measurements via Ultrafast Laser Spectroscopy with Structured Light

Detonations and flames are characterized by three-dimensional (3D) temperature fields, yet state-of- the-art temperature measurement techniques yield information at a point or along a line. The goal of the research documented here was to combine ultrafast laser spectroscopy and structured illumination to deliver an unprecedented measurement capability—three-dimensional, instantaneous temperature measurements in a gas-phase volume. To achieve this objective, different parts of the proposed technique were developed and tested independently. Structured illumination was used to image particulate matter (soot) in a turbulent flame at multiple planes using a single laser pulse and a single camera. Emission spectroscopy with structured detection was demonstrated for emission- based measurements of explosives with enhance dimensionality. Finally, an instrument for multi- planar laser-based temperature measurement technique was developed. Structured illumination techniques will continue to be developed for multi-dimensional and multi-parameter measurements. These new measurement capabilities will be important for heat transfer and fluid dynamic research areas.

42 ENGINEERING↗

Exploring grain boundary energy landscapes with the activation-relaxation technique

To develop a structure–kinetic property mapping for grain boundaries requires an understanding of their energy landscapes, i.e. the energy basins and nearby saddle points separating adjacent structures. We implement here the activation-relaxation technique to obtain a first view of grain boundary energy landscapes for the Σ5 (1 3 0), Σ5 (2 1 0) and Σ3 (1 1 1) grain boundaries in copper. The energy landscapes of these boundaries are very different, which supports a focus on energy landscapes, rather than absolute boundary energy, to understand boundary properties.

36 MATERIALS SCIENCE↗