Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST STATISTIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Durability testing of actual Hanford waste glasses and their non-radioactive simulant glasses

The low-activity waste (LAW) fraction of Hanford tank waste will be converted to glass at the Waste Treatment and Immobilization Plant (WTP) and disposed on the Hanford site. The chemical durability of LAW glasses has been researched for decades to satisfy contract requirements. Most LAW glass durability data has been generated on non-radioactive simulant glasses fabricated via crucible melts. These non-radioactive glasses were chosen due to safety and cost reasons with confidence that radioactive waste glasses would exhibit similar behavior. To reduce the risk of significant differences in laboratory test response data between WTP melter waste glass and simulant glass, Product Consistency Tests (PCT, i.e., ASTM C1285-21) and Environmental Protection Agency (EPA) 1313 durability tests were performed on actual and simulant LAW glasses fabricated using laboratory-scaled melters. Actual and simulant glass durability test results are presented and statistically compared. Finally, differences in test responses were found to be within experimental uncertainty.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Fiber Bragg Gratings at Elevated Temperatures

The development of integrated fiber optic sensors for smart propulsion systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor s limits and how it responds under various environmental conditions. The sensor evaluation currently involves examining the performance of fiber Bragg gratings at elevated temperatures. Fiber Bragg gratings (FBG) are periodic variations of the refractive index of an optical fiber. These periodic variations allow the FBG to act as an embedded optical filter passing the majority of light propagating through a fiber while reflecting back a narrow band of the incident light. The peak reflected wavelength of the FBG is known as the Bragg wavelength. Since the period and width of the refractive index variation in the fiber determines the wavelengths that are transmitted and reflected by the grating, any force acting on the fiber that alters the physical structure of the grating will change what wavelengths are transmitted and what wavelengths are reflected by the grating. Both thermal and mechanical forces acting on the grating will alter its physical characteristics allowing the FBG sensor to detect both temperature variations and physical stresses, strain, placed upon it. This ability to sense multiple physical forces makes the FBG a versatile sensor. This paper reports on test results of the performance of FBGs at elevated temperatures. The gratings looked at thus far have been either embedded in polymer matrix materials or freestanding with the primary focus of this paper being on the freestanding FBGs. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. These parameters include the peak Bragg wavelength, the power of the Bragg wavelength, and total power returned by the FBG. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, and referencing techniques are presented in the paper along with directions for future research.

Juergens, Jeffrey↗

Thermal Evaluation of Fiber Bragg Gratings at Extreme Temperatures

The development of integrated fiber optic sensors for use in aerospace health monitoring systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor's capabilities, limitations, and performance under extreme environmental conditions. This paper reports on our current sensor evaluation examining the performance of freestanding fiber Bragg gratings (FBG) at extreme temperatures. While the ability of FBGs to survive at extreme temperatures has been established, their performance and long term survivability is not well documented. At extreme temperatures the grating structure would be expected to dissipate, degrading the sensors performance and eventually ceasing to return a detectable signal. The fiber jacket will dissipate leaving a brittle, unprotected fiber. For FBGs to be used in aerospace systems their performance and limitations need to be thoroughly understood at extreme temperatures. As the limits of the FBGs performance are pushed the long term survivability and performance of the sensor comes into question. We will not only examine the ability of FBGs to survive extreme temperatures but also look at their performance during many thermal cycles. This paper reports on test results of the performance of thermal cycling commercially available FBGs, at temperatures up to 1000 C, seen in aerospace applications. Additionally this paper will report on the performance of commercially available FBGs held at 1000 C for hundreds of hours. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, referencing techniques, performance data, and interpretations and explanations of results are presented in the paper along with directions for future research.

Juergens, Jeffrey↗

A Laser Technology Test Facility for Laser Inertial Fusion Energy (LIFE)

A LIFE laser driver needs to be designed and operated which meets the rigorous requirements of the NIF laser system while operating at high average power, and operate for a lifetime of >30 years. Ignition on NIF will serve to demonstrate laser driver functionality, operation of the Mercury laser system at LLNL demonstrates the ability of a diode-pumped solid-state laser to run at high average power, but the operational lifetime >30 yrs remains to be proven. A Laser Technology test Facility (LTF) has been designed to specifically address this issue. The LTF is a 100-Hz diode-pumped solid-state laser system intended for accelerated testing of the diodes, gain media, optics, frequency converters and final optics, providing system statistics for billion shot class tests. These statistics will be utilized for material and technology development as well as economic and reliability models for LIFE laser drivers.

42 ENGINEERING↗

STAT7 v2.0 Verification and Validation Report

This report documents the software testing which has been performed for STAT7 Version 2.0 (hereafter STAT7 v2.0), a code for the statistical propagation of uncertainties in steady-state thermal hydraulics (TH) analysis of plate-fueled research and test reactors. The key capabilities addressed in this testing were selected based on the use of the software for analysis work supporting the conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors (USHPRR) such as the Massachusetts Institute of Technology Research Reactor (MITR-II). This testing scope includes comparison of the code’s statistical processing capabilities using statistical tests, comparison of coolant property evaluations to NIST data tables, and systematic comparison of key TH solver capabilities to the results of hand calculations and to predictions from PLTEMP/ANL Version 4.4. The

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hanford Tank Waste Disposition Integrated Flowsheet: Corrosion Specification Development Final Report

The Savannah River National Laboratory has developed a corrosion model to facilitate implementation of Hanford’s Direct Feed Low Activity Waste flowsheet. The focus was specifically on secondary effluent waste stream compositions from the Hanford Waste Treatment and Immobilization Plant’s melter off-gas treatment system returned to the Hanford Tank Farms (return stream.) The return stream compositions were predicted to contain components at relative concentrations that are significantly more corrosive toward the carbon steel waste tanks, specifically halide and sulfate anions, than the current waste compositions in the tank farms. Electrochemical tests were performed, utilizing a statistically designed matrix, to determine the corrosion chemistry limits that will mitigate pitting in the return stream. The current corrosion chemistry specifications for the Hanford Tank Farms do not mitigate for the halide concentrations that will be expected in the return stream. The model requires a 10:1 nitrite to total halide ratio, for stream compositions at a minimum of pH 10 and a maximum temperature of 40°C. The final specification may use other corrosion data that is being generated for the DST chemistry control limits to delineate between the effect of fluoride and chloride. This test program has employed statistically designed test matrices and electrochemical test methods to validate the corrosion model specifically at boundary regions to optimize corrosion control specifications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Self Consistent Multiprocessor Space Charge Algorithm that is Almost Embarrassingly Parallel

We present a space charge code that is self consistent, massively parallelizeable, and requires very little communication between computer nodes; making the calculation almost embarrassingly parallel. This method is implemented in the code COSY Infinity where the differential algebras used in this code are important to the algorithm's proper functioning. The method works by calculating the self consistent space charge distribution using the statistical moments of the test particles, and converting them into polynomial series coefficients. These coefficients are combined with differential algebraic integrals to form the potential, and electric fields. The result is a map which contains the effects of space charge. This method allows for massive parallelization since its statistics based solver doesn't require any binning of particles, and only requires a vector containing the partial sums of the statistical moments for the different nodes to be passed. All other calculations are done independently. The resulting maps can be used to analyze the system using normal form analysis, as well as advance particles in numbers and at speeds that were previously impossible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗

A COMPARISON OF GADRAS SIMULATED AND MEASURED GAMMA RAY SPECTRA

Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running

Figueiredo, PS, Looney, DP, Pryor, JL, Doughty, EM, McClung, HL, Vangala, SV, Santee, WR, Beidleman, BA, and Potter, AW. Verification of maximal oxygen uptake in active military personnel during treadmill running. J Strength Cond Res 36(4): 1053–1058, 2022—It is unclear whether verification tests are required to confirm “true” maximal oxygen uptake ($\dot{V}_{o2}$max) in modern warfighter populations. Our study investigated the prevalence of $\dot{V}_{o2}$max attainment in U.S. Army soldiers performing a traditional incremental running test. In addition, we examined the utility of supramaximal verification testing as well as repeated trials for familiarization for accurate $\dot{V}_{o2}$max assessment. Sixteen U.S. Army soldiers (1 woman, 15men; age, 21±2 years; height, 1.73±0.06m; body mass, 71.6±10.1 kg) completed 2 laboratory visits, each with an incremental running test (modified Astrand protocol) and a verification test (110% maximal incremental test speed) on a motorized treadmill. We evaluated $\dot{V}_{o2}$max attainment during incremental testing by testing for the definitive $\dot{V}_{o2}$ plateau using a linear least-squares regression approach. Peak oxygen uptake ($\dot{V}_{o2}$peak) was considered statistically equivalent between tests if the 90% confidence interval around the mean difference was within 62.1 ml·kg -1 ·min -1 . Oxygen uptake plateaus were identified in 14 of 16 volunteers for visit 1 (87.5%) and all 16 volunteers for visit 2 (100%). Peak oxygen uptake was not statistically equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between the incremental test and verification test on visit 1 (2.3 ml·kg -1 ·min -1 , [1.3–3.2]) or visit 2 (1.1 ml·kg -1 ·min -1 [0.2–2.1]). Interestingly, $\dot{V}_{o2}$peak was equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between visits for the incremental tests (0.0ml·kg -1 ·min -1 [-0.8to 0.9]) but not the verification tests (-1.2 ml·kg -1 ·min -1 [-2.2 to -0.2]). Modern U.S. Army soldiers can attain $\dot{V}_{o2}$max by performing a modified Astrand treadmill running test. Additional familiarization and verification tests for confirming $\dot{V}_{o2}$max in healthy active military personnel may be unnecessary.

60 APPLIED LIFE SCIENCES↗

Dynamic Response of Layered TiB/Ti Functionally Graded Material Specimens

This paper covers the dynamic response of rectangular (25.4x101.6x3.175 mm) specimens manufactured from layers of TiB/Ti. The layers contained volume fractions of TiB that varied from 0 to 85% and thus formed a functionally graded material. Witness samples of the 85% TiB material were also tested to provide a baseline for the statistical variability of the test techniques. Static and dynamic tests were performed to determine the in situ material properties and fundamental frequencies. Damping in the material/ fixture was also found from the dynamic response. These tests were simulated using composite beam theory which gave an analytical solution, and using finite element analysis. The response of the 85% TiB specimens was found to be much more uniform than the functionally graded material and the dynamic response more uniform than the static response. A least squares analysis of the data using the analytical solutions were used to determine the elastic modulus and Poisson's ratio of each layer. These results were used to model the response in the finite element analysis. The results indicate that current analytical and numerical methods for modeling the material give similar and adequate predictions for natural frequencies if the measured property values were used. The models did not agree as well if the properties from the manufacturer or those of Hill and Linn were used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The generation of surface targets with specified surface statistics

Results are presented from efforts to generate physical surfaces from known or desired surface statistical properties, proceeding from previous work on the generation of random surfaces for use in computer simulations. The known statistical surface is extended using a bicubic spline technique; these results are interfaced with a numerically controlled machine in order to generate the physical surface. A portion of a complete surface with Gaussian statistics was constructed and tested to measure conformity to the desired statistics.

Rochier, J. D.↗

STAT7 v1.2 Verification and Validation Report

This report documents the software testing which has been performed for the STAT7 Version 1.2 (hereafter STAT7 v1.2) software, a code for the statistical propagation of uncertainties in steady-state thermal hydraulics (TH) analysis of plate-fueled research and test reactors. The key capabilities addressed in this testing were selected based on the use of the software for analysis work supporting the conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors (USHPRR) such as the Massachusetts Institute of Technology Research Reactor (MITR-II). This testing scope includes comparison of the code’s statistical processing capabilities using statistical tests, comparison of coolant property evaluations to NIST data tables, and systematic comparison of key TH solver capabilities to the results of hand calculations and to predictions from PLTEMP/ANL Version 4.4. The good agreement achieved in this testing campaign, within the acceptance criteria of a 1% relative difference, also demonstrates that these capabilities have been implemented in STAT7 v1.2 correctly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Construction of Supersonic Flight Dynamics Test (SFDT-2) Vehicle Monte Carlo Splashdown Footprints for Use in Range Safety and Recovery Planning

Overview of Low Density Supersonic Decelerator (LDSD) SFDT-2 ( Supersonic Flight Dynamics Test-2) flight profile; Description of Monte Carlo flight dynamics simulations performed; Modeling and uncertainties; Results with statistical prediction of test vehicle splashdown location; Use of Monte Carlo results for range safety and recovery planning.

Strauss, Bill↗

Estimation of process steady state with autoregressive models and Bayesian inference

To improve efficiency, separations engineers will typically design process circuits containing recirculating streams, which mix one or more of the process outputs with the feed material. Doing so can improve efficiency, but will cause a delay in the system reaching steady state conditions until the recirculating load mass flows stabilize. In testing separation circuits, engineers will often test a variety of factors and complete an analysis from sample results. Knowledge of if a process is at steady state, as well as the steady state conditions of a process, is essential for a valid techno-economic analysis. However, the definition of process steady state is often poorly defined, or does not include uncertainty quantification. If the performance of a process operating under two different sets of conditions are compared, an engineer who does not test for steady state or quantify steady state conditions risks producing a faulty analysis. In this work, a Bayesian statistical method for testing if all streams are at steady state is further motivated and then derived. Then after testing for steady state, the same model is used with a prior distribution that enforces a steady state assumption to estimate steady state conditions. Further, these methods were validated in a solvent extraction pilot plant where steady state conditions for all outflows were inferred with uncertainty quantification. Analysis is completed with functions available to the reader as part of the BayesMassBal (V 1.1.0) software package written in R.

01 COAL, LIGNITE, AND PEAT↗

Gaze as a biometric

Two people may analyze a visual scene in two completely different ways. Our study sought to determine whether human gaze may be used to establish the identity of an individual. To accomplish this objective we investigated the gaze pattern of twelve individuals viewing different still images with different spatial relationships. Specifically, we created 5 visual dot-pattern tests to be shown on a standard computer monitor. These tests challenged the viewer s capacity to distinguish proximity, alignment, and perceptual organization. Each test included 50 images of varying difficulty (total of 250 images). Eye-tracking data were collected from each individual while taking the tests. The eye-tracking data were converted into gaze velocities and analyzed with Hidden Markov Models to develop personalized gaze profiles. Using leave-one-out cross-validation, we observed that these personalized profiles could differentiate among the 12 users with classification accuracy ranging between 53% and 76%, depending on the test. This was statistically significantly better than random guessing (i.e., 8.3% or 1 out of 12). Classification accuracy was higher for the tests where the users average gaze velocity per case was lower. The study findings support the feasibility of using gaze as a biometric or personalized biomarker. These findings could have implications in Radiology training and the development of personalized e-learning environments.

eye tracking↗

Program for Weibull Analysis of Fatigue Data

A Fortran computer program has been written for performing statistical analyses of fatigue-test data that are assumed to be adequately represented by a two-parameter Weibull distribution. This program calculates the following: (1) Maximum-likelihood estimates of the Weibull distribution; (2) Data for contour plots of relative likelihood for two parameters; (3) Data for contour plots of joint confidence regions; (4) Data for the profile likelihood of the Weibull-distribution parameters; (5) Data for the profile likelihood of any percentile of the distribution; and (6) Likelihood-based confidence intervals for parameters and/or percentiles of the distribution. The program can account for tests that are suspended without failure (the statistical term for such suspension of tests is "censoring"). The analytical approach followed in this program for the software is valid for type-I censoring, which is the removal of unfailed units at pre-specified times. Confidence regions and intervals are calculated by use of the likelihood-ratio method.

Krantz, Timothy L.↗