Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

THE NASCENT FAST SOLAR WIND OBSERVED BY THE EUV IMAGING SPECTROMETER ON BOARD HINODE

The origin of the solar wind is one of the most important unresolved problems in space and solar physics. We report here the first spectroscopic signatures of the nascent fast solar wind on the basis of observations made by the EUV Imaging Spectrometer on Hinode in a polar coronal hole in which patches of blueshift are clearly present on Dopplergrams of coronal emission lines with a formation temperature of lg(T/K)>5.8. The corresponding upflow is associated with open field lines in the coronal hole and seems to start in the solar transition region and becomes more prominent with increasing temperature. This temperature-dependent plasma outflow is interpreted as evidence of the nascent fast solar wind in the polar coronal hole. The patches with significant upflows are still isolated in the upper transition region but merge in the corona, in agreement with the scenario of solar wind outflow being guided by expanding magnetic funnels.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTION OF WIDESPREAD HYDRATED MATERIALS ON VESTA BY THE VIR IMAGING SPECTROMETER ON BOARD THE DAWN MISSION

Water plays a key role in the evolution of terrestrial planets, and notably in the occurrence of Earth's oceans. However, the mechanism by which water has been incorporated into these bodies-including Earth-is still extensively debated. Here we report the detection of widespread 2.8 {mu}m OH absorption bands on the surface of the asteroid Vesta by the VIR imaging spectrometer on board Dawn. These observations are surprising as Vesta is fully differentiated with a basaltic surface. The 2.8 {mu}m OH absorption is distributed across Vesta's surface and shows areas enriched and depleted in hydrated materials. The uneven distribution of hydrated mineral phases is unexpected and indicates ancient processes that differ from those believed to be responsible for OH on other airless bodies, like the Moon. The origin of Vestan OH provides new insight into the delivery of hydrous materials in the main belt and may offer new scenarios on the delivery of hydrous minerals in the inner solar system, suggesting processes that may have played a role in the formation of terrestrial planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of β -decay feeding patterns of 88 Rb and 88 Kr using the Modular Total Absorption Spectrometer at ORNL HRIBF

We report precise determination of ground-state feeding in the β decay of fission products is an important but challenging component in modeling reactor antineutrino flux and reactor decay heat. The Modular Total Absorption Spectrometer (MTAS) is a versatile NaI(Tl) detector array that determines the true β-decay pattern free from the pandemonium effect, including precise ground-state feeding intensities. In this paper, we report MTAS results of the β feeding intensities of 88 Rb and 88 Kr, fission products with large cumulative yields in nuclear reactors. By comparing MTAS results with previous measurements, 88 Rb provides a validation of MTAS's ability to determine ground-state feedings in β decays, while the precision of 88 Kr ground-state feeding is improved when compared with the Evaluated Nuclear Structure Data File (ENSDF). The investigation of sources that contribute to β feeding branching uncertainties in MTAS experiments is discussed in detail. Lastly, the deconvolution of 88 Rb decay spectra suggests that MTAS can distinguish an allowed β spectral shape from a first forbidden unique β spectral shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New mass measurement of {sup 6}Li and ppb-level systematic studies of the Penning trap mass spectrometer TITAN

The frequency ratio of {sup 6}Li to {sup 7}Li was measured using the TITAN Penning trap mass spectrometer. This measurement resolves a 16-ppb discrepancy between the {sup 6}Li mass of 6.015 122 795(16) u from the Atomic Mass Evaluation 2003 (AME03), which is based on a measurement by JILATRAP, and the more recent measurement of 6.015 122 890(40) u by SMILETRAP. Our measurement agrees with SMILETRAP and a more precise mass value for {sup 6}Li of 6.015 122 889(26) u is presented along with systematic evaluations of the measurement uncertainties. This result makes {sup 6}Li a solid anchor point for future mass measurements on highly charged ions with m/q{approx}6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission fragment mass and energy distributions as a function of incident neutron energy measured in a lead slowing-down spectrometer

A new method of measuring fission fragment mass and energy distributions as a function of incident neutron energy in the range from below 0.1 eV to 1 keV has been developed. The method involves placing a double-sided Frisch-gridded fission chamber in Rensselaer Polytechnic Institute's lead slowing-down spectrometer (LSDS). The high neutron flux of the LSDS allows for the measurement of the energy-dependent, neutron-induced fission cross sections simultaneously with the mass and kinetic energy of the fission fragments of various small samples. The samples may be isotopes that are not available in large quantities (submicrograms) or with small fission cross sections (microbarns). The fission chamber consists of two anodes shielded by Frisch grids on either side of a single cathode. The sample is located in the center of the cathode and is made by depositing small amounts of actinides on very thin films. The chamber was successfully tested and calibrated using 0.41+-0.04 ng of {sup 252}Cf and the resulting mass distributions were compared to those of previous work. As a proof of concept, the chamber was placed in the LSDS to measure the neutron-induced fission cross section and fragment mass and energy distributions of 25.3+-0.5 mug of {sup 235}U. Changes in the mass distributions as a function of incident neutron energy are evident and are examined using the multimodal fission mode model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New developments for the determination of the response function for a BC501A compact neutron spectrometer for fusion diagnostics

The compact neutron spectrometer project was initiated to develop a device able to study fast neutrons produced by fusion reactions in a tokamak. The goal is to provide a fully characterized BC501A detector using a digital acquisition system developed by ENEA. The pulse height resolution and the response matrix of the detector are determined using experimental data acquired at the PTB facility. To achieve this goal, methods of data analysis involving entropy maximization and new software were developed. The methods are described and the current results for the pulse height resolution are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Superconducting Horizontal Bend Magnet for the Jefferson Lab's 11 GeV/c Super High Momentum Spectrometer

A collaboration between NSCL and Jlab has developed the reference design and coil winding for Jlab's Super High Momentum Spectrometer (SHMS) horizontal bend magnet. A warm iron ??C?? type superferric dipole magnet will bend the 12 GeV/c particles horizontally by 3?? to allow the SHMS to reach angles as low as 5.5??. This requires an integral field strength of up to 2.1 T.m. The major challenges are the tight geometry, high and unbalanced forces and a required low fringe field in primary beam path. A coil design based on flattened SSC Rutherford cable that provides a large current margin and commercially available fiberglass prepreg epoxy tape has been developed. A complete test coil has been wound and will be cold tested. This paper present the modified magnet design includes coil forces, coil restraint system and fringe field. In addition, coil properties, quench calculations and the full mechanical details are also presented.

43 PARTICLE ACCELERATORS↗

Operational Experience with the MICE Spectrometer Solenoid System

The Muon Ionization Cooling Experiment located at Rutherford Appleton Laboratory in England utilizes a supercon-ducting solenoid system for the muon cooling channel that also holds particle tracking detectors and muon absorbers inside their bores. The solenoid system installation was completed in summer of 2015 and after commissioning the system it has been running successfully. As a result, this paper summarizes the commissioning results and operational experience with the magnets focusing on the per-formance of the two Spectrometer Solenoids built by the US.

43 PARTICLE ACCELERATORS↗

ASIC for SDD-Based X-ray Spectrometers

We present an application-specific integrated circuit (ASIC) for high-resolution x-ray spectrometers (XRS). The ASIC reads out signals from pixelated silicon drift detectors (SDDs). The pixel does not have an integrated field effect transistor (FET); rather, readout is accomplished by wire-bonding the anodes to the inputs of the ASIC. The ASIC dissipates 32 mW, and offers 16 channels of low-noise charge amplification, high-order shaping with baseline stabilization, discrimination, a novel pile-up rejector, and peak detection with an analog memory. The readout is sparse and based on custom low-power tristatable low-voltage differential signaling (LPT-LVDS). A unit of 64 SDD pixels, read out by four ASICs, covers an area of 12.8 cm{sup 2} and dissipates with the sensor biased about 15 mW/cm{sup 2}. As a tile-based system, the 64-pixel units cover a large detection area. Our preliminary measurements at -44 C show a FWHM of 145 eV at the 5.9 keV peak of a {sup 55}Fe source, and less than 80 eV on a test-pulse line at 200 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Proton-proton physics with the ALICE muon spectrometer at the LHC

ALICE, the dedicated heavy-ion experiment at the LHC, has also an important proton-proton physics program. The ALICE muon spectrometer will be presented and the corresponding physics analysis will be reviewed. A particular emphasis will be placed on heavy-flavor measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of the decay {eta}' {yields} 3{pi}{sup 0} with the GAMS-4{pi} spectrometer

An experiment performed with the GAMS-4{pi} spectrometer resulted in observing 235 {+-} 45 events of the decay {eta}' {yields} 3{pi}{sup 0}. The respective charge-exchange reaction at a momentum of 32.5 GeV/c was used as a source of {eta}' mesons. The decay branching ratio was found to be Br({eta}' {yields} 3{pi}{sup 0}) = (1.8 {+-} 0.4) x 10{sup -3}. The slope parameter of the square of the respective matrix element in the linear approximation proved to be {beta} = -0.59 {+-} 0.18.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the matrix element for the decay {eta}' {yields} {eta}{pi}0{pi}0 with the GAMS-4{pi} spectrometer

The parameters of the Dalitz diagram for the decay {eta}' {yields} {eta}{pi}0{pi}0 in a generalized and a linear representation were determined by using a statistical sample of 15 x 10{sup 3} events. A charge-exchange reaction at a momentum of 32 GeV/c was a source of monoenergetic {eta}' mesons. The experiment was performed with the aid of the GAMS-4{pi} spectrometer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PNPI differential EDM spectrometer and latest results of measurements of the neutron electric dipole moment

In this work, the double chamber magnetic resonance spectrometer of the Petersburg Nuclear Physics Institute (PNPI) designed to measure the neutron electric dipole moment (EDM) is briefly described. A method for long storage of polarized ultracold neutrons in a resonance space with a superposed electric field collinear to the leading magnetic field is used. The results of the measurements carried out on the ILL reactor (Grenoble, France) are interpreted as the upper limit of the value of neutron EDM vertical bar d{sub n} vertical bar < 5.5 × 10{sup –26}e cm at the 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗