Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

C-SAW: a framework for graph sampling and random walk on GPUs

Many applications require to learn, mine, analyze and visualize large-scale graphs. These graphs are often too large to be addressed efficiently using conventional graph processing technologies. Fortunately, recent research efforts find out graph sampling and random walk, which significantly reduce the size of original graphs, can benefit the tasks of learning, mining, analyzing and visualizing large graphs by capturing the desirable graph properties. This paper introduces C-SAW, the first framework that accelerates Sampling and Random Walk framework on GPUs. Particularly, C-SAW makes three contributions: First, our framework provides a generic API which allows users to implement a wide range of sampling and random walk algorithms with ease. Second, offloading this framework on GPU, we introduce warp-centric parallel selection, and two novel optimizations for collision migration. Third, towards supporting graphs that exceed the GPU memory capacity, we introduce efficient data transfer optimizations for out-of-memory and multi-GPU sampling, such as workload-aware scheduling and batched multi-instance sampling. Taken together, our framework constantly outperforms the state of the art projects in addition to the capability of supporting a wide range of sampling and random walk algorithms.

97 MATHEMATICS AND COMPUTING↗

Nuclear fuel behavior at high temperature: new insights from post-test examinations on the VERDON-1 sample

In order to reduce the uncertainties concerning Source Term assessment under Light Water Reactor (LWR) severe accident conditions, 4 VERDON tests were recently performed. They have been defined in the framework of the International Source Term Program and carried out at CEA Cadarache, in the LECA-STAR facility. Among these 4 VERDON tests, VERDON-1 test was devoted to high burn-up UO{sub 2} fuel behavior and FP release under H{sub 2} reducing conditions at very high temperature. This test was performed with the Release Circuit, which is devoted to the precise characterization of the FP release, in terms of FP release kinetics and fission products (FPs) released fraction. The main components of the circuits are a furnace heating the fuel sample, a filter trapping the emitted aerosols and gamma spectrometry detectors for online and post-test measurements. VERDON-1 test was conducted up to about 2600 Celsius degrees without reaching global fuel relocation, allowing thereby post-test micro-analyses. After a brief description of the fuel sample nature and the experimental set-up, we present the progress of the experimental sequence and the associated gamma spectrometry measurements. We then focus on the major results of the VERDON-1 tests regarding the fuel global behavior. These results are obtained by two complementary techniques. First, the fuel sight gamma station can be used either on-line to detect fuel relocation or just after the test, as a longitudinal bench, to get preliminary information on the global shape of the fuel sample inside the furnace. Secondly, these information are completed by post-test examinations performed on the fuel sample after extraction from the furnace. Complete qualitative and quantitative characterizations, including EPMA (Electron Probe Micro-Analysis) and SEM (Scanning Electron Microscopy) analysis, were performed for the first time at the CEA Cadarache on a sample that has been submitted to such severe accident conditions. These results show an advanced state of sample degradation, with locally previously molten areas, meaning that fuel global relocation was imminent by the end of thermal-hydraulic sequence. The relocation temperature is compared to that of previous VERCORS tests and discussed regarding the atmosphere of the test and possible UO{sub 2}-ZrO{sub 2} interaction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Humidified sample preparation station for serial crystallography

Humidified sample preparation station for serial crystallography according to one embodiment is a humidified enclosure that delivers relative humidities above 95% and preferably above 97% in standard operation, and that can allow microscope observation of samples within. Humidified sample preparation station for serial crystallography can be used for preparation of protein crystal samples for examination using X-rays and for protein structure determination by X-ray crystallography, involving addition of liquid to the sample and removal of liquid from the sample using vacuum or suction.

Jayne, Richard↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

Apparatus and methods for sample analysis with multi-gradient microfluidics

A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.

Kim, Peter Wonhee↗

Analysis Of Fracture Location on Tensile Graphite Samples

The main standard for testing the ultimate tensile strength of graphite is ASTM C749. Commercial entities have raised concerns about samples breaking outside of the gauge section, particularly in the radius or head of the sample. When this occurs, the data gathered from the samples is unusable and increases the cost of testing as more samples will need to be machined. This study investigates the locations and frequency of sample breakage for four different grades of graphite using a custom-made measurement scale. The four grades include two fine-grain (2114 and IG-110) and two medium/coarse-grain (NBG-17 and PCEA). Our results show that fine-grain grades are more susceptible to breaking outside the gauge section, with almost 30% of the samples from grade 2114 breaking outside this region. Additionally, the radius being too small causes stress concentrations near the ends of the gauge section resulting in a bimodal distribution of the fracture locations.

36 - MATERIALS SCIENCE↗

An interoperable implementation of collective‐variable based enhanced sampling methods in extended phase space within the OpenMM package

Collective variable (CV)-based enhanced sampling techniques are widely used today for accelerating barrier-crossing events in molecular simulations. A class of these methods, which includes temperature accelerated molecular dynamics (TAMD)/driven-adiabatic free energy dynamics (d-AFED), unified free energy dynamics (UFED), and temperature accelerated sliced sampling (TASS), uses an extended variable formalism to achieve quick exploration of conformational space. These techniques are powerful, as they enhance the sampling of a large number of CVs simultaneously compared to other techniques. Extended variables are kept at a much higher temperature than the physical temperature by ensuring adiabatic separation between the extended and physical subsystems and employing rigorous thermostatting. Here, in this work, we present a computational platform to perform extended phase space enhanced sampling simulations using the open-source molecular dynamics engine OpenMM. The implementation allows users to have interoperability of sampling techniques, as well as employ state-of-the-art thermostats and multiple time-stepping. This work also presents protocols for determining the critical parameters and procedures for reconstructing high-dimensional free energy surfaces. As a demonstration, we present simulation results on the high dimensional conformational landscapes of the alanine tripeptide in vacuo, tetra-N-methylglycine (tetra-sarcosine) peptoid in implicit solvent, and the Trp-cage mini protein in explicit water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

Importance of Sample Handling and Preparation for Surface Analysis: A Summary of ISO Standard 20579 Part 1, Documenting and Reporting the Handling of Specimens Prior to Analysis

Reliable and reproducible analysis of surfaces is critically dependent on how samples have been collected, handled, and prepared before analysis. Although there are important, well-established general guidelines to minimize unintended alteration of the surfaces to be analyzed, specific handling steps depend on the nature of the samples and information desired. Assessments of the validity and reliability of the results require adequate information about sampling, handling, and processing. ISO standard 20579 part 1 describes the information to be recorded and reported for samples that are prepared or submitted for surface analysis. This paper summarizes elements of the standard, which includes annexes that justify and inform the sample handling processes. Also included is a checklist of information that needs to be recorded and reported and an appendix containing an example of a form that might be used to report the information.

AES↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Sample Collection Metadata for Soil Cores from the East River Watershed, Colorado collected in 2017

This data package contains sample collection metadata for soil cores from the East River Watershed in Colorado used in biogeochemical analyses by the Watershed Function SFA. Soil cores were collected seasonally during autumn, winter, snowmelt, and spring at a predominately montane meadow, high altitude field site. Information provided for each soil core sample assigned an International Geo Sample Number (IGSN) includes: sample name, IGSN, material, description, collection method, core depth, location, field program, collectors, and date. The full list of 53 IGSN's is listed in the Methods section. There is also a complete core sample list and metadata for the set of baseline data.

54 ENVIRONMENTAL SCIENCES↗

Dispersion-enhanced sequential batch sampling for adaptive contour estimation

In computer simulation and optimal design, sequential batch sampling offers an appealing way to iteratively stipulate optimal sampling points based upon existing selections and efficiently construct surrogate modeling. Nonetheless, the issue of near duplicates poses tremendous quandary for sequential learning. It refers to the situation that selected critical points cluster together in each sampling batch, which are individually but not collectively informative towards the optimal design. Near duplicates severely diminish the computational efficiency as they barely contribute extra information towards update of the surrogate. To address this issue, we impose a dispersion criterion on concurrent selection of sampling points, which essentially forces a sparse distribution of critical points in each batch, and demonstrate the effectiveness of this approach in adaptive contour estimation. Specifically, we adopt Gaussian process surrogate to emulate the simulator, acquire variance reduction of the critical region from new sampling points as a dispersion criterion, and combine it with the modified expected improvement (EI) function for critical batch selection. The critical region here is the proximity of the contour of interest. This proposed approach is vindicated in numerical examples of a two-dimensional four-branch function, a four-dimensional function with a disjoint contour of interest and a time-delay dynamic system.

97 MATHEMATICS AND COMPUTING↗

Benchtop-compatible sample processing workflow for proteome profiling of < 100 mammalian cells

Extending proteomics to smaller samples can enable the mapping of protein expression across tissues with high spatial resolution and can reveal sub-group heterogeneity. However, despite the continually improving sensitivity of LC-MS instrumentation, in-depth profiling of samples containing low-nanogram amounts of protein has remained challenging due to analyte losses incurred during preparation and analysis. To address this, we recently developed nanodroplet processing in one pot for trace samples (nanoPOTS), a robotic/microfluidic platform that generates ready-to-analyze peptides from cellular material in ~200 nL droplets with greatly reduced sample losses. In combination with ultrasensitive LC-MS, nanoPOTS has enabled >3000 proteins to be confidently identified from as few as 10 cultured human cells and ~700 proteins from single cells. However, the nanoPOTS platform requires a highly skilled operator and a costly in-house-built robotic nanopipetting instrument. In this work, we sought to evaluate the extent to which the benefits of nanodroplet processing could be preserved when upscaling reagent dispensing volumes by a factor of 10 to those addressable by commercial micropipette. We characterized the resulting platform, termed microdroplet processing in one pot for trace samples (µPOTS), for the analysis of as few as ~25 cultured HeLa cells (4 ng total protein) or 50 µm square mouse liver tissue thin sections and found that ~1800 and ~1200 unique proteins were respectively identified with high reproducibility. As such, the reduced equipment requirements should facilitate broad dissemination of nanoproteomics workflows by obviating the need for a capital-intensive custom liquid handling system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Registration of Cone-Beam Computer Tomography and Preprocedural Computer Tomography Aids in Localization of Adrenal Veins and Decreasing Radiation Dose in Adrenal Vein Sampling

PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectively compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A sensitivity analysis to predict the neutronics behavior of samples irradiated in the VTR rabbit system

We report a low-order neutronics model is developed to carry out hundreds of simulations efficiently and investigate the neutronics behavior of samples being irradiated in a test reactor setting under different geometrical constraints. The low-order model allowed for simulations that yield the expected neutronics behavior of any irradiated sample in any environment and allows for the calculation of highly accurate spatially averaged statistics and idealized spatial distributions in the neutron flux. Several benchmarks are performed to evaluate the performance and limitations of the low-order model revealing many important findings. The low-order model predicted the LHGR in the EBR-II driver fuel to within 2.34% by only simulating the fuel rod by itself, which served as a validation for the model. Sensitivity studies investigated 3% enriched UO 2 and U-10Zr being irradiated in the Versatile Test Reactor rabbit system. The analyses investigated a range of combinations of 15 radii and 5 heights for each sample in the rabbit system. Similar data sets are also provided for irradiations in the Advanced Test Reactor’s B-10 irradiation position, which is a thermal neutron spectrum environment. Generalized fits and fit coefficients are obtained for sample heating, reaction rate densities, and local multiplication rate characteristics, allowing the predictions of the neutronics behavior of the samples based on their geometrical constraints. The analyses and fits laid the groundwork for developing a user-end Multiphysics analysis framework to assist and accelerate irradiation experiment design and optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implicit sampling combined with reduced order modeling for the inversion of vadose zone hydrological data

Bayesian inverse modeling techniques are computationally expensive because many forward simulations are needed when sampling the posterior distribution of the parameters. Here, in this paper, we combine the implicit sampling method and generalized polynomial chaos expansion (gPCE) to significantly reduce the computational cost of performing Bayesian inverse modeling. There are three steps in this approach: (1) find the maximizer of the likelihood function using deterministic approaches; (2) construct a gPCE-based surrogate model using the results from a limited number of forward simulations; and (3) efficiently sample the posterior distribution of the parameters using implicit sampling method. The cost of constructing the gPCE-based surrogate model is further decreased by using sparse Bayesian learning to reduce the number of gPCE coefficients that have to be determined. We demonstrate the approach for a synthetic ponded infiltration experiment simulated with TOUGH2. The surrogate model is highly accurate with mean relative error that is < 0.035% in predicting saturation and < 0.25% in predicting the likelihood function. The posterior distribution of the parameters obtained using our proposed technique is nearly indistinguishable from the results obtained from either an implicit sampling method or a Markov chain Monte Carlo method utilizing the full mode.

54 ENVIRONMENTAL SCIENCES↗