Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Systematic drug safety evaluation based on public genomic expression (Connectivity Map) data: Myocardial and infectious adverse reactions as application cases

Adverse drug reaction (ADR) is of great importance to both regulatory agencies and the pharmaceutical industry. Various techniques, such as quantitative structure–activity relationship (QSAR) and animal toxicology, are widely used to identify potential risks during the preclinical stage of drug development. Despite these efforts, drugs with safety liabilities can still pass through safety checkpoints and enter the market. This situation raises the concern that conventional chemical structure analysis and phenotypic screening are not sufficient to avoid all clinical adverse events. Genomic expression data following in vitro drug treatments characterize drug actions and thus have become widely used in drug repositioning. In the present study, we explored prediction of ADRs based on the drug-induced gene-expression profiles from cultured human cells in the Connectivity Map (CMap) database. The results showed that drugs inducing comparable ADRs generally lead to similar CMap expression profiles. Based on such ADR-gene expression association, we established prediction models for various ADRs, including severe myocardial and infectious events. Drugs with FDA boxed warnings of safety liability were effectively identified. We therefore suggest that drug-induced gene expression change, in combination with effective computational methods, may provide a new dimension of information to facilitate systematic drug safety evaluation. - Highlights: • Drugs causing common toxicity lead to similar in vitro gene expression changes. • We built a model to predict drug toxicity with drug-specific expression profiles. • Drugs with FDA black box warnings were effectively identified by our model. • In vitro assay can detect severe toxicity in the early stage of drug development.

60 APPLIED LIFE SCIENCES↗

Critical review and analysis of hydrogen safety data collection tools

The wider adoption of hydrogen in multiple sectors of the economy requires that safety and risk issues be rigorously investigated. Quantitative Risk Assessment (QRA) is an important tool for enabling safe deployment of hydrogen fueling stations and is increasingly embedded in the permitting process. QRA requires reliability data, and currently hydrogen QRA is limited by the lack of hydrogen specific reliability data, thereby hindering the development of necessary safety codes and standards [1]. Four tools have been identified that collect hydrogen system safety data: H2Tools Lessons Learned, Hydrogen Incidents and Accidents Database (HIAD), National Renewable Energy Lab's (NREL) Composite Data Products (CDPs), and the Center for Hydrogen Safety (CHS) Equipment and Component Failure Rate Data Submission Form. This work critically reviews and analyzes these tools for their quality and usability in QRA. It is determined that these tools lay a good foundation, however, the data collected by these tools needs improvement for use in QRA. Areas in which these tools can be improved are highlighted, and can be used to develop a path towards adequate reliability data collection for hydrogen systems.

08 HYDROGEN↗

Development of a Quality and Safety Competency Curriculum for Radiation Oncology Residency: An International Delphi Study

Purpose: To develop an entry-to-practice quality and safety competency profile for radiation oncology residency. Methods and Materials: A comprehensive list of potential quality and safety competency items was generated from public and professional resources and interprofessional focus groups. Redundant or out-of-scope items were eliminated through investigator consensus. Remaining items were subjected to an international 2-round modified Delphi process involving experts in radiation oncology, radiation therapy, and medical physics. During Round 1, each item was scored independently on a 9-point Likert scale indicating appropriateness for inclusion in the competency profile. Items indistinctly ranked for inclusion or exclusion were re-evaluated through web conference discussion and reranked in Round 2. Results: An initial 1211 items were compiled from 32 international sources and distilled to 105 unique potential quality and safety competency items. Fifteen of the 50 invited experts participated in round 1: 10 radiation oncologists, 4 radiation therapists, and 1 medical physicist from 13 centers in 5 countries. Round 1 rankings resulted in 80 items included, 1 item excluded, and 24 items indeterminate. Two areas emerged more prominently within the latter group: change management and human factors. Web conference with 5 participants resulted in 9 of these 24 items edited for content or clarity. In Round 2, 12 participants rescored all indeterminate items resulting in 10 items ranked for inclusion. The final 90 enabling competency items were organized into thematic groups consisting of 18 key competencies under headings adapted from Deming's System of Profound Knowledge. Conclusions: This quality and safety competency profile may inform minimum training standards for radiation oncology residency programs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Regulatory aspects of oncology drug safety evaluation: Past practice, current issues, and the challenge of new drugs

The drug development of new anti-cancer agents is streamlined in response to the urgency of bringing effective drugs to market for patients with limited life expectancy. FDA's regulation of oncology drugs has evolved from the practices set forth in Arnold Lehman's seminal work published in the 1950s through the current drafting of a new International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) safety guidance for anti-cancer drug nonclinical evaluations. The ICH combines the efforts of the regulatory authorities of Europe, Japan, and the United States and the pharmaceutical industry from these three regions to streamline the scientific and technical aspects of drug development. The recent development of new oncology drug classes with novel mechanisms of action has improved survival rates for some cancers but also brings new challenges for safety evaluation. Here we present the legacy of Lehman and colleagues in the context of past and present oncology drug development practices and focus on some of the current issues at the center of an evolving harmonization process that will generate a new safety guidance for oncology drugs, ICH S9. The purpose of this new guidance will be to facilitate oncology drug development on a global scale by standardizing regional safety requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ventilatory function assessment in safety pharmacology: Optimization of rodent studies using normocapnic or hypercapnic conditions

Although the whole body plethysmography for unrestrained animals is the most widely used method to assess the respiratory risk of new drugs in safety pharmacology, non-appropriate experimental conditions may mask deleterious side effects of some substances. If stimulant or bronchodilatory effects can be easily evidenced in rodents under standard experimental conditions, i.e. normal air breathing and diurnal phase, drug-induced respiratory depression remains more difficult to detect. This study was aimed at comparing the responsiveness of Wistar rats, Duncan Hartley guinea-pigs or BALB/c mice to the respiratory properties of theophylline (50 or 100 mg/kg p.o.) or morphine (30 mg/kg i.p.) under varying conditions (100% air versus 5% CO{sub 2}-enriched air, light versus dark day phase), in order to select the most appropriate experimental conditions to each species for safety airway investigations. Our results showed that under normocapnia the ventilatory depressant effects of morphine can be easily evidenced in mice, slightly observed in guinea-pigs and not detected in rats in any day phase. Slight hypercapnic conditions enhanced the responsiveness of rats to morphine but not that of guinea-pigs and importantly they did not blunt the airway responsiveness of rats to the stimulation and bronchodilation evoked by theophylline, the most widely used reference agent in safety pharmacology studies. In conclusion, hypercapnic conditions associated with the non-invasive whole body plethysmography should be considered for optimizing the assessment of both the ventilatory depressant potential of morphine-like substances or the respiratory stimulant effects of new drugs in the rat, the most extensively used species in rodent safety and toxicological investigations.

60 APPLIED LIFE SCIENCES↗

Comparing the cardiovascular therapeutic indices of glycopyrronium and tiotropium in an integrated rat pharmacokinetic, pharmacodynamic and safety model

Long acting inhaled muscarinic receptor antagonists, such as tiotropium, are widely used as bronchodilator therapy for chronic obstructive pulmonary disease (COPD). Although this class of compounds is generally considered to be safe and well tolerated in COPD patients the cardiovascular safety of tiotropium has recently been questioned. We describe a rat in vivo model that allows the concurrent assessment of muscarinic antagonist potency, bronchodilator efficacy and a potential for side effects, and we use this model to compare tiotropium with NVA237 (glycopyrronium bromide), a recently approved inhaled muscarinic antagonist for COPD. Anaesthetized Brown Norway rats were dosed intratracheally at 1 or 6 h prior to receiving increasing doses of intravenous methacholine. Changes in airway resistance and cardiovascular function were recorded and therapeutic indices were calculated against the ED{sub 50} values for the inhibition of methacholine-induced bronchoconstriction. At both time points studied, greater therapeutic indices for hypotension and bradycardia were observed with glycopyrronium (19.5 and 28.5 fold at 1 h; > 200 fold at 6 h) than with tiotropium (1.5 and 4.2 fold at 1 h; 4.6 and 5.5 fold at 6 h). Pharmacokinetic, protein plasma binding and rat muscarinic receptor binding properties for both compounds were determined and used to generate an integrated model of systemic M{sub 2} muscarinic receptor occupancy, which predicted significantly higher M{sub 2} receptor blockade at ED{sub 50} doses with tiotropium than with glycopyrronium. In our preclinical model there was an improved safety profile for glycopyrronium when compared with tiotropium. - Highlights: • We use an in vivo rat model to study CV safety of inhaled muscarinic antagonists. • We integrate protein and receptor binding and PK of tiotropium and glycopyrrolate. • At ED{sub 50} doses for bronchoprotection we model systemic M{sub 2} receptor occupancy. • Glycopyrrolate demonstrates lower M{sub 2} occupancy at bronchoprotective doses. • Glycopyrrolate demonstrates an improved CV safety profile, versus tiotropium.

60 APPLIED LIFE SCIENCES↗

E-scooter safety: How attitudinal factors influence risky behavior among shared e-scooter riders

In recent years, e-scooter usage for short-distance trips has grown rapidly. This surge in e-scooter use, combined with the high exposure of e-scooter riders to accident risk, has sparked concerns regarding e-scooter safety. Despite some studies focusing on e-scooter safety, little is known about how attitudinal factors lead e-scooter riders to engage in risky riding behaviors. In this paper, we developed a survey-based empirical model to identify the attitudinal factors influencing engagement in risky behaviors among e-scooter users. We used survey data collected from 420 shared e-scooter users in Chicago in 2022. The survey showed that 47.7% of respondents had experienced at least one collision or fall-off while riding e-scooters. We employed the Partial Least Squares Structural Equation Model (PLS-SEM) to examine the relationships between latent attitudinal factors and risky behavior engagement. Moreover, we conducted Permutation Multi-group Analysis (PMGA) to assess the moderating effect of socio-demographic factors within the estimated model. The findings suggest that riders’ unsafe riding attitude and riding confidence are the most influential factors shaping their risky behavior engagement. In addition, accident experience, infrastructure suitability, perceived enjoyment, traffic risk perception, and operational risk perception are among the other significant predictors. Among socio-demographic factors, gender, age, education, and car use frequency significantly influence riders’ engagement in risky behaviors. The results highlight the importance of infrastructure suitability and accident experience in analyzing e-scooter users’ riding behavior. The developed model advances our understanding of factors contributing to e-scooter riders’ risky behavior engagement. The findings offer valuable insights for policymakers and e-scooter vendors aiming to mitigate e-scooter users’ accident risk. Specifically, we recommend three safety countermeasures: (1) safety training programs to encourage a safer attitude, (2) practice-based initiatives to enhance riding confidence, and (3) infrastructure improvements, especially the expansion of bike lanes.

E-scooter↗

Pre- and post-exposure safety and efficacy of attenuated rabies virus vaccines are enhanced by their expression of IFNγ

Consistent with evidence of a strong correlation between interferon gamma (IFNγ) production and rabies virus (RABV) clearance from the CNS, we recently demonstrated that engineering a pathogenic RABV to express IFNγ highly attenuates the virus. Reasoning that IFNγ expression by RABV vaccines would enhance their safety and efficacy, we reverse-engineered two proven vaccine vectors, GAS and GASGAS, to express murine IFNγ. Mortality and morbidity were monitored during suckling mice infection, immunize/challenge experiments and mixed intracranial infections. We demonstrate that GASγ and GASγGAS are significantly attenuated in suckling mice compared to the GASGAS vaccine. GASγ better protects mice from lethal DRV4 RABV infection in both pre- and post-exposure experiments compared to GASGAS. Finally, GASγGAS reduces post-infection neurological sequelae, compared to control, during mixed intracranial infection with DRV4. These data show IFNγ expression by a vaccine vector can enhance its safety while increasing its efficacy as pre- and post-exposure treatment. - Highlights: • IFNγ expression improves attenuated rabies virus safety and immunogenicity. • IFNγ expression is safer and more immunogenic than doubling glycoprotein expression. • Co-infection with IFNγ-expressing RABV prevents wild-type rabies virus lethality. • Vaccine safety and efficacy is additive for IFNγ and double glycoprotein expression.

60 APPLIED LIFE SCIENCES↗

Crossover as Determinant for Safety and Performance Tradeoffs in Proton Exchange Membrane Water Electrolyzers

Hydrogen (H2) crossover is a pressing challenge constraining safe and efficient operation of proton exchange membrane water electrolyzers (PEMWEs) especially amongst strides to employ thinner membranes, which enables improved energy efficiency, and elevated cathode pressures, that reduces the energy burden on downstream compressors. Here, we develop a microstructure-aware multicomponent reactive-transport framework that resolves dissolved and gaseous H2 transport pathways and mechanistically links electrode architecture to crossover related safety and performance. We show that operability is co-governed by the cathode catalyst layer (CCL) and the anode porous transport layer (APTL) which sets the H2 crossover flux and the egress capacity respectively. Elevated Pt/C ratio in the CCL suppresses crossover flux by up to 23% while a higher APTL porosity lowers H2 in O2 fraction by 0.6% in the anode effluent. We condense the findings into (cathode pressure-current density) maps overlaid with safety limits and performance targets and ultimately define two safety-performance unified metrics to gauge the size and quality of the operating window. Given the push towards higher pressure and deeper turndown for renewable integration, this study provides mechanistic design guidance to prevent crossover-induced safety risks while preserving the desired performance.

Electrolysis↗

A Safety and Management Framework to Enable Automated Mobility Districts in Urban Areas

Automated mobility technology is beginning to emerge as a viable means to create sustainable and effective public mobility systems within denser urban environments. Automated mobility districts (AMDs) describe major urban districts or activity centers in which deployments of multiple automated vehicle (AV) transit and ride-hailing fleets are supported to meet public mobility needs. The authors put forward a framework to enable AMDs and their governing and management jurisdictional authorities to manage safety of AV operations based on lessons learned from the last century of automated guideway transit and roadway intersection traffic control systems. The essential concept is that of operational management and safety-critical control of multiple AV fleets using a “system-of-systems” approach to system safety analysis. The safety analysis would focus on safe passage of the AV fleet vehicles through complex roadway intersections and junctions, especially in the presence of other non-automated modes such as pedestrians and manually operated vehicles.

47 OTHER INSTRUMENTATION↗

Design and Fabrication of Safety Shutter for Indus-2 Synchrotron Front-ends

This paper describes the design and fabrication of safety shutter for the Indus-2 synchrotron source on bending magnet front-ends. The purpose of the safety shutter is to absorb Bremsstrahlung radiation generated due to scattering of electron beam from residual gas ions and components of the storage ring. The safety shutter consists of a radiation absorber actuated inside a rectangular ultra high vacuum chamber by pneumatic actuator. A water-cooled copper block is mounted before the absorber block to protect it from the incident heat load due to synchrotron radiation. The top flanges of the chamber are made with rectangular knife edge sealing which is found to be better than wire seal at higher temperature. The physics aspect of safety shutter is designed using simulation code Electron Gamma Shower EGS-4 code.

43 PARTICLE ACCELERATORS↗

Parallel computation safety analysis irradiation targets fission product molybdenum in neutronic aspect using the successive over-relaxation algorithm

One of the research activities in support of commercial radioisotope production program is a safety research on target FPM (Fission Product Molybdenum) irradiation. FPM targets form a tube made of stainless steel which contains nuclear-grade high-enrichment uranium. The FPM irradiation tube is intended to obtain fission products. Fission materials such as Mo{sup 99} used widely the form of kits in the medical world. The neutronics problem is solved using first-order perturbation theory derived from the diffusion equation for four groups. In contrast, Mo isotopes have longer half-lives, about 3 days (66 hours), so the delivery of radioisotopes to consumer centers and storage is possible though still limited. The production of this isotope potentially gives significant economic value. The criticality and flux in multigroup diffusion model was calculated for various irradiation positions and uranium contents. This model involves complex computation, with large and sparse matrix system. Several parallel algorithms have been developed for the sparse and large matrix solution. In this paper, a successive over-relaxation (SOR) algorithm was implemented for the calculation of reactivity coefficients which can be done in parallel. Previous works performed reactivity calculations serially with Gauss-Seidel iteratives. The parallel method can be used to solve multigroup diffusion equation system and calculate the criticality and reactivity coefficients. In this research a computer code was developed to exploit parallel processing to perform reactivity calculations which were to be used in safety analysis. The parallel processing in the multicore computer system allows the calculation to be performed more quickly. This code was applied for the safety limits calculation of irradiated FPM targets containing highly enriched uranium. The results of calculations neutron show that for uranium contents of 1.7676 g and 6.1866 g (× 10{sup 6} cm{sup −1}) in a tube, their delta reactivities are the still within safety limits; however, for 7.9542 g and 8.838 g (× 10{sup 6} cm{sup −1}) the limits were exceeded.

07 ISOTOPE AND RADIATION SOURCES↗

Estimating Code Biases for Criticality Safety Applications with Few Relevant Benchmarks

Criticality safety analyses rely on the availability of relevant benchmark experiments to determine justifiable margins of subcriticality. When a target application lacks neutronically similar benchmark experiments, validation studies must provide justification to the regulator that the impact of modeling and simulation limitations is well understood for the application and often must provide additional subcritical margin to ensure safe operating conditions. This study estimated the computational bias in the critical eigenvalue for several criticality safety applications supported by only a few relevant benchmark experiments. The accuracy of the following three methods for predicting computational biases was evaluated: the Upper Subcritical Limit STATisticS (USLSTATS) trending analysis method; the Whisper nonparametric method; and TSURFER, which is based on the generalized linear least-squares technique. Here, these methods were also applied to estimate computational biases and recommended upper subcriticality limits for several critical experiments with known biases and for several cases from a blind benchmark study. The methods are evaluated based on both the accuracy of their predicted computation bias and upper subcriticality limit estimates, as well as on the consistency of the methods’ estimates, as the model parameters, covariance data libraries, and set of available benchmark data were varied. Data assimilation methods typically have not been used for criticality safety licensing activities, and this study explores a methodology to address concerns regarding the reliability of such methods in criticality safety bias prediction applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Transformational Challenge Reactor Safety Design and Radionuclide Retention Strategy

An integrated safety design and radionuclide (RN) retention strategy is developed to support the Transformational Challenge Reactor (TCR) demonstration. This demonstration aims to showcase viability for rapid deployment of a novel reactor by leveraging the advances in materials, manufacturing, and computational sciences through a highly integrated and agile design and development approach. This strategy provides a logical description and understanding of how RNs are contained within the facility. Rather than discussing fission product barriers individually between separate design and safety basis reports, this paper provides a consistent description and narrative to better facilitate regulatory interactions and focus safety design efforts. The principal barriers credited include the various coating layers in the tristructural isotropic (TRISO) fuel particle, the silicon carbide (SiC) matrix hosting the particles within the fuel element, the helium pressure boundary, and the confinement system. The choice and assumed performance of the credited barriers are highly conservative, which is a direct reflection of the low hazard that the TCR demonstration presents and the need to simplify and focus the safety review process accordingly. However, the strategy and the associated framework are generalized and may be adopted and tailored to support other advanced reactor demonstration efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-C-BRD-05: Implementation of Incident Learning in the Safety and Quality Management of Radiotherapy: The Primary Experience in a New Established Program with Advanced Techniques

Purpose: To explore the implementation and effectiveness of incident learning for the safety and quality of radiotherapy in a new established radiotherapy program with advanced technology. Methods: Reference to the consensus recommendations by American Association of Physicist in Medicine, an incident learning system was specifically designed for reporting, investigating, and learning of individual radiotherapy incidents in a new established radiotherapy program, with 4D CBCT, Ultrasound guided radiotherapy, VMAT, gated treatment delivered on two new installed linacs. The incidents occurring in external beam radiotherapy from February, 2012 to January, 2014 were reported. Results: A total of 33 reports were analyzed, including 28 near misses and 5 incidents. Among them, 5 originated in imaging for planning, 25 in planning, 1 in plan transfer, 1 in commissioning and 1 in treatment delivery. Among them, three near misses originated in the safety barrier of the radiotherapy process. In terms of error type, 1 incident was classified as wrong patient, 7 near misses/incidents as wrong site, 6 as wrong laterality, 5 as wrong dose, 7 as wrong prescription, and 7 as suboptimal plan quality. 5 incidents were all classified as grade 1/2 of dosimetric severity, 1 as grade 0, and the other 4 as grade 1 of medical severity. For the causes/contributory factors, negligence, policy not followed, inadequate training, failure to develop an effective plan, and communication contributed to 19, 15, 12, 5 and 3 near misses/incidents, respectively. The average incident rate per 100 patients treated was 0.4; this rate fell to 0.28% in the second year from 0.56% in the first year. The rate of near miss fell to 1.24% from 2.22%. Conclusion: Effective incident learning can reduce the occurrence of near miss/incidents, enhance the culture of safety. Incident learning is an effective proactive method for improving the quality and safety of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogate measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.

60 APPLIED LIFE SCIENCES↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tracking Study for Top-off Safety Validation at SSRL

A tracking study was performed at SSRL to identify necessary controls and to prove the safety of top-off operation from radiation hazard under such conditions. The safety rationale, tracking setup and the results are presented. Top-off operational mode has become a trend for existing and planned third-generation storage ring light sources for the many benefits such as increased average brightness, improved thermal stability and elimination of the interruption to user experiments due to traditional injection [1, 2]. Unlike the traditional decay mode injection which happens a few times a day and during which the photon beamline shutters are closed, top-off mode injection requires photon beamline shutters to remain open during injection and occurs much more frequently, from once every 5 seconds to once every 30 minutes. Therefore injection may be transparent to user experiments and the stored current variation can be significantly reduced. For a facility equipped with a full-energy injector, the biggest challenge to the implementation of the top-off mode may be the control of radiation hazard. Studies at ALS and SSRL [2, 3] have shown that a single injected electron pulse that enters the photon beamline and exits the radiation shield wall would cause unacceptable radiation doses on the experimental floor. For the protection of users and experimental equipment, it is hence a prerequisite for top-off operation to establish controls that absolutely prevent such occurrences. Similar to other facilities such as ALS and APS [2, 4], tracking simulations were conducted at SSRL to identify the control measures, define the specifications and prove the radiation safety. However, a different approach toward the proof of safety is taken at SSRL. In this paper we first describe the SSRL accelerator complex with emphasis on the aspects related to top-off in section 2. The general considerations and requirements for top-off are presented in section 3. Section 4 and 5 give a detailed description of the tracking setup and results. Concluding remarks are given in section 6.

43 PARTICLE ACCELERATORS↗