Post launch performance of the Meteor-3/TOMS instrument

The Meteor-3/TOMS instrument is the second in a series of Total Ozone Mapping Spectrometers (TOMS) following the 1978 launch of Nimbus-7/TOMS. TOMS instruments are designed to measure total ozone amounts over the entire earth on a daily basis, and have been the cornerstone of ozone trend monitoring. Consequently, calibration is a critical issue, and is receiving much attention on both instruments. Performance and calibration data obtained by monitoring systems aboard the Meteor-3 instrument have been analyzed through the first full year of operation, and indicate that the instrument is performing quite well. A new system for monitoring instrument sensitivity employing multiple diffusers has been used successfully and is providing encouraging results. The 3-diffuser system has monitored changes in instrument sensitivity of a few percent despite decreases in diffuser reflectivity approaching 50 percent since launch.

Jaross, Glen↗

Simulation evaluation of the control system command monitoring concept for the NASA V/STOL research aircraft (VSRA)

A control-system monitoring concept is described that has the potential of rapidly detecting computer command failures (hardware or software) in fly-by-wire control systems. The concept has been successfully tested on the NASA Vertical/Short Takeoff and Landing Research Aircraft (VSRA) in the Ames Research Center's Vertical Motion Simulator. The test was particularly stringent, since the VSRA is required to operate in a hazardous environment. The fidelity of the aircraft model used in the simulation was verified by flying both the simulated and actual aircraft in a precision hover task using specially designed targets.

Schroeder, J. A.↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Mountaineer Commercial Scale Carbon Capture and Storage Project Topical Report: Preliminary Public Design Report

This Preliminary Public Design Report consolidates for public use nonproprietary design information on the Mountaineer Commercial Scale Carbon Capture & Storage project. The report is based on the preliminary design information developed during the Phase I - Project Definition Phase, spanning the time period of February 1, 2010 through September 30, 2011. The report includes descriptions and/or discussions for: (1) DOE's Clean Coal Power Initiative, overall project & Phase I objectives, and the historical evolution of DOE and American Electric Power (AEP) sponsored projects leading to the current project; (2) Alstom's Chilled Ammonia Process (CAP) carbon capture retrofit technology and the carbon storage and monitoring system; (3) AEP's retrofit approach in terms of plant operational and integration philosophy; (4) The process island equipment and balance of plant systems for the CAP technology; (5) The carbon storage system, addressing injection wells, monitoring wells, system monitoring and controls logic philosophy; (6) Overall project estimate that includes the overnight cost estimate, cost escalation for future year expenditures, and major project risks that factored into the development of the risk based contingency; and (7) AEP's decision to suspend further work on the project at the end of Phase I, notwithstanding its assessment that the Alstom CAP technology is ready for commercial demonstration at the intended scale.

01 COAL, LIGNITE, AND PEAT↗

Culture-Based Environmental Microbiology Monitoring of Crop-Based Space Food Systems (veggie Monitoring)

Crewmembers live and work in a closed environment that is monitored to ensure their health and safety. Quarterly monitoring of the microorganisms in the International Space Station (ISS) environment supports crew safety and contributes to a large set of microbial concentration and diversity data from air, surfaces and water samples. This study leverages quarterly operational Environmental Health System (EHS) sampling by collecting additional microbial samples from the surface of the station’s Veggie plant production system. Longer exploration missions may require spaceflight-based systems for growth of plants, and this investigation is expected to provide additional data to help establish requirements to protect these systems, plants, and crew, mitigating adverse microbial exposure.

Hamilton, Tanner↗

2022 Annual Report: Culture-Based Environmental Microbiology Monitoring of Crop-based Space Food Systems (Veggie Monitoring)

Crewmembers live and work in a closed environment that is monitored to ensure their health and safety. Quarterly monitoring of the microorganisms in the International Space Station (ISS) environment supports crew safety and contributes to a large set of environmental microbial data from the air, surface, and water samples that are collected. This study leverages quarterly operational Environmental Health System (EHS) sampling by collecting additional microbial samples from the surface of the station’s Veggie plant production system. Longer exploration missions may require spaceflight-based systems for growth of plants, and this investigation is expected to provide additional data to help establish requirements to protect these systems, plants, and crew, mitigating adverse microbial exposure.

Tanner Hamilton↗

Launch Complex 39A Operations Support Building Area SWMU 111 Year 3 Air Sparge System Performance Monitoring Report

This Air Sparge (AS) System Performance Monitoring Report (PMR) presents the findings, observations, and results for Year 3 of operation, maintenance, and monitoring activities for the AS Interim Measure (IM) at the Launch Complex 39A Operations Support Building Area (AOSB) at Kennedy Space Center (KSC), Florida. This report was presented as an Advance Data Package during the October 2024 KSC Remediation Team (KSCRT) meeting. The reporting period for activities covered under this PMR is from August 2023 through October 2024.

Mark P Speranza↗

Data sampling system for monitor and control station

System design is based on development of standardized, interchangeable modules that minimize power dissipation, interconnecting cables and size. Maximum flexibility is achieved by using building block approach where all data modules are identical and are connected at any remote location and addressed in random fashion from central unit.

Source record↗

Method and system for monitoring environmental conditions

A system for detecting the occurrence of anomalies includes a plurality of spaced apart nodes, with each node having adjacent nodes, each of the nodes having one or more sensors associated with the node and capable of detecting anomalies, and each of the nodes having a controller connected to the sensors associated with the node. The system also includes communication links between adjacent nodes, whereby the nodes form a network. At least one software agent is capable of changing the operation of at least one of the controllers in response to the detection of an anomaly by a sensor.

Kulesz, James J↗

Lightning Protection System

A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC-39B), at the Kennedy Space Center (KSC), Florida, in 2009, for NASA’s Space Launch System (SLS) program. A comprehensive lightning monitoring system was additionally designed and the LC-39B lightning instrumentation started incremental deployment early 2011. By March 2011, the LC-39B lightning monitoring system was activated with short outages during construction and renovations of the LC-39B. Since 2011, the LC-39B LPS has been directly struck at least once per year. The earliest and latest in a year that the LPS has been directly struck by lightning has been January 7th and October 1st (both 2017), respectively. During the summer of 2018, the Mobile Launcher 1 (ML-1) lightning monitoring system was deployed and partially active during ML-1 construction/testing. Since 2018, the ML-1 has been parked at the LC-39B for different durations of time for integrated testing. Early August 2019 (6th and 9th ) multiple lightning strikes terminated directly on the LPS at three different locations in addition to a nearby strike within the Pad perimeter and multiple nearby strikes outside the Pad Perimeter, triggering both, the LC-39B and the ML-1 lightning monitoring systems. This has been the first time direct lightning strikes have terminated on the LPS or within the LC-39B perimeter while the ML-1 has been at the LC-39B. This paper summarizes direct and close nearby lightning strikes to LC-39B from 2011 until the summer of 2019.

Angel G Mata↗

Automated monitoring of recovered water quality

Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

Misselhorn, J. E.↗

NSI operations center

The NASA Science Internet (NSI) Network Operations Staff is responsible for providing reliable communication connectivity for the NASA science community. As the NSI user community expands, so does the demand for greater interoperability with users and resources on other networks (e.g., NSFnet, ESnet), both nationally and internationally. Coupled with the science community's demand for greater access to other resources is the demand for more reliable communication connectivity. Recognizing this, the NASA Science Internet Project Office (NSIPO) expands its Operations activities. By January 1990, Network Operations was equipped with a telephone hotline, and its staff was expanded to six Network Operations Analysts. These six analysts provide 24-hour-a-day, 7-day-a-week coverage to assist site managers with problem determination and resolution. The NSI Operations staff monitors network circuits and their associated routers. In most instances, NSI Operations diagnoses and reports problems before users realize a problem exists. Monitoring of the NSI TCP/IP Network is currently being done with Proteon's Overview monitoring system. The Overview monitoring system displays a map of the NSI network utilizing various colors to indicate the conditions of the components being monitored. Each node or site is polled via the Simple Network Monitoring Protocol (SNMP). If a circuit goes down, Overview alerts the Network Operations staff with an audible alarm and changes the color of the component. When an alert is received, Network Operations personnel immediately verify and diagnose the problem, coordinate repair with other networking service groups, track problems, and document problem and resolution into a trouble ticket data base. NSI Operations offers the NSI science community reliable connectivity by exercising prompt assessment and resolution of network problems.

Zanley, Nancy L.↗

Reliability Value of Fast State Estimation on Power Systems

Monitoring the state of a power system under stress is key to achieving reliable operation. State estimation and timely measurements become more important when applying and designing corrective control actions (manual and automatic) to arrest or mitigate cascading blackouts. The execution time of each process, including state estimation, should be as short as possible to allow for timely action. In this paper, we provide a methodology for estimating one of the components of value of faster and more frequent state estimation: the reliability value of state estimation to assist corrective control actions for arresting or mitigating cascading blackouts. We present a new algorithm for estimating the time between successive line trips in a cascading failure. The algorithm combines power flow calculations with characteristics of the protection system to estimate the time between successive equipment trips. Using this algorithm, we illustrate the value of fast state estimation by calculating the time remaining for automatic or manual corrective actions after state estimation is finalized.

Power system state estimation, cascading failures,↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

47 OTHER INSTRUMENTATION↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rocket engine control and monitoring expert system

This paper focuses on the application of expert systems technology to the automatic detection, verification and correction of anomalous rocket engine operations through interfacing with an intelligent adaptive control system. The design of a reliable and intelligent propulsion control and monitoring system is outlined which includes the architecture of an Integrated Expert System (IES) serving as the core component. The IES functions include automatic knowledge acquisition, integrated knowledge base, and fault diagnosis and prediction methodology. The results of fault analysis and diagnostic techniques are presented for an example fault in the SSME main combustion chamber injectors.

Ali, Moonis↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗