Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Effects of a gravity gradient on human cardiovascular responses

Eight subjects participated in one control and three rotation trials on a short-arm centrifuge such that the Gz levels at the feet were 0.5, 1.0, and 1.5 G. Trials consisted of 30 minutes of supine rest, 1 hour of rotation (or in the control, 30 additional minutes of rest and 30 minutes of standing), and a final 30-minute rest period. Measurements of heart rate, calf impedance, calf volume, and blood pressure support the findings that the highest G level is similar to standing and that the lower G levels fail to produce significant effects.

NASA Discipline Cardiopulmonary↗

Artificial gravity intermittent centrifugation as a space flight countermeasure

Head-down bed rest was used to simulate weightlessness in an experiment that examined variations in dose, time, and frequency of +Gz stimuli countermeasures. Results indicate that 4 hr. standing was most effective for orthostatic intolerance, walking was most effective in achieving peak oxygen consumption, 4 hr. of standing or walking had the best effect on plasma volume, and 4 hr. of walking was most effective in maintaining urinary calcium excretion.

NASA Discipline General Space Life Sciences↗

Computer simulation of the effect of dDAVP with saline loading on fluid balance after 24-hour head-down tilt

Fluid loading (FL) before Shuttle reentry is a countermeasure currently in use by NASA to improve the orthostatic tolerance of astronauts during reentry and postflight. The fluid load consists of water and salt tablets equivalent to 32 oz (946 ml) of isotonic saline. However, the effectiveness of this countermeasure has been observed to decrease with the duration of spaceflight. The countermeasure's effectiveness may be improved by enhancing fluid retention using analogs of vasopressin such as lypressin (LVP) and desmopressin (dDAVP). In a computer simulation study reported previously, we attempted to assess the improvement in fluid retention obtained by the use of LVP administered before FL. The present study is concerned with the use of dDAVP. In a recent 24-hour, 6 degree head-down tilt (HDT) study involving seven men, dDAVP was found to improve orthostatic tolerance as assessed by both lower body negative pressure (LBNP) and stand tests. The treatment restored Luft's cumulative stress index (cumulative product of magnitude and duration of LBNP) to nearly pre-bedrest level. The heart rate was lower and stroke volume was marginally higher at the same LBNP levels with administration of dDAVP compared to placebo. Lower heart rates were also observed with dDAVP during stand test, despite the lower level of cardiovascular stress. These improvements were seen with only a small but significant increase in plasma volume of approximately 3 percent. This paper presents a computer simulation analysis of some of the results of this HDT study.

NASA Discipline Cardiopulmonary↗

Development of Semi-Span Model Test Techniques

A computational investigation was performed to support the development of a semi-span model test capability in the NASA Langley Research Center's National Transonic Facility. This capability is desirable for the testing of advanced subsonic transport aircraft at full-scale Reynolds numbers. A state-of-the-art three-dimensional Navier-Stokes solver was used to examine methods to improve the flow over a semi-span configuration. First, a parametric study is conducted to examine the influence of the stand-off height on the flow over the semi-span model. It is found that decreasing the stand-off height, below the maximum fuselage radius, improves the aerodynamic characteristics of the semi-span model. Next, active sidewall boundary layer control techniques are examined. Juncture region blowing jets, upstream tangential blowing, and sidewall suction are found to improve the flow over the aft portion of the semi-span model. Both upstream blowing and suction are found to reduce the sidewall boundary layer separation. The resulting near surface streamline patterns are improved, and found to be quite similar to the full-span results. Both techniques however adversely affect the pitching moment coefficient.

Pulnam, L. Elwood↗

Stabilization of posture by precision touch of the index finger with rigid and flexible filaments

Light touch of the index finger with a stationary surface at non-mechanically supportive force levels (<100 g) greatly attenuates the body sway of standing subjects. In three experiments, we evaluated the properties of finger contact and of the contacted object necessary to produce postural stabilization in subjects standing heel-to-toe with eyes closed, as well as how accurately hand position can be controlled. Experiment 1 involved finger contact with flexible filaments of different bending strengths, a flat surface, and an imagined spatial position. Contact with the flat surface was most effective in attenuating sway; the flexible filaments were much less effective but still significantly better than imagined contact. Experiment 2 compared the effectiveness of finger contact with a flexible filament, a rigid filament of the same diameter, a flat surface, and an imagined spatial position. The rigid filament and flat surface conditions were equally effective in attenuating body sway and were greatly superior to contact with the flexible filament, which was superior to imagined contact. Experiment 3 included five conditions: arms by sides; finger "contact" with an imagined spatial position; finger contact with a flat surface; finger contact with a flexible filament attempting to maintain it bent; and contact with the flexible filament attempting not to bend it. The arms by sides and finger "contact" with an imagined position conditions did not differ significantly; all three conditions involving actual finger contact showed significantly less center of pressure and hand sway, but contact with the flat surface was most effective in attenuating both postural and hand displacement. In all three experiments, the level of force applied in fingertip contact conditions was far below that necessary to provide mechanical stabilization. Our findings indicate that: (1) stimulation of a small number of receptors in the fingertip is adequate to allow stabilization of sway, (2) fingertip force levels as low as 5-10 g provide some stabilization, (3) contact with a stationary spatial referent is most effective, and (4) independent control of arm and torso occurs when finger contact is allowed.

NASA Discipline Neuroscience↗

Eye height scaling of absolute size in immersive and nonimmersive displays

Eye-height (EH) scaling of absolute height was investigated in three experiments. In Experiment 1, standing observers viewed cubes in an immersive virtual environment. Observers' center of projection was placed at actual EH and at 0.7 times actual EH. Observers' size judgments revealed that the EH manipulation was 76.8% effective. In Experiment 2, seated observers viewed the same cubes on an interactive desktop display; however, no effect of EH was found in response to the simulated EH manipulation. Experiment 3 tested standing observers in the immersive environment with the field of view reduced to match that of the desktop. Comparable to Experiment 1, the effect of EH was 77%. These results suggest that EH scaling is not generally used when people view an interactive desktop display because the altitude of the center of projection is indeterminate. EH scaling is spontaneously evoked, however, in immersive environments.

NASA Discipline Space Human Factors↗

A mechanical energy analysis of gait initiation

The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.

Leg/physiology↗

Idiopathic orthostatic intolerance and postural tachycardia syndromes

Upright posture imposes a substantial gravitational stress on the body, for which we are able to compensate, in large part because of the autonomic nervous system. Alteration in autonomic function, therefore, may lead to orthostatic intolerance. On one extreme, patients with autonomic failure caused by degenerative loss of autonomic function are severely disabled by orthostatic hypotension and may faint whenever they stand up. Fortunately, such patients are relatively rare. On the other hand, disabling orthostatic intolerance can develop in otherwise normal young people. These patients can be severely impaired by symptoms of fatigue, tachycardia, and shortness of breath when they stand up. The actual incidence of this disorder is unknown, but these patients make up the largest group of patients referred to centers that specialize in autonomic disorders. We will review recent advances made in the understanding of this condition, potential pathophysiological mechanisms that contribute to orthostatic intolerance, therapeutic alternatives currently available for the management of these patients, and areas in which more research is needed.

Review↗

Effects of volume loading and pressor agents in idiopathic orthostatic tachycardia

BACKGROUND: Idiopathic orthostatic tachycardia (IOT) is characterized by an increase in heart rate (HR) with standing of > or = 30 bpm that is associated with elevated catecholamine levels and orthostatic symptoms. A dynamic orthostatic hypovolemia and alpha1-adrenoreceptor hypersensitivity have been demonstrated in IOT patients. There is evidence of an autonomic neuropathy affecting the lower-extremity blood vessels. METHODS AND RESULTS: We studied the effects of placebo, the alpha1-adrenoreceptor agonist midodrine (5 to 10 mg), the alpha2-adrenoreceptor agonist clonidine (0.1 mg), and I.V. saline (1 L) in 13 patients with IOT. Supine and upright blood pressure (BP) and HR were measured before and at 1 and 2 hours after intervention. Midodrine decreased both supine and upright HR (all HR values are given as bpm) at 2 hours (from 78+/-2 supine to 108+/-5 upright before treatment and from 69+/-2 supine to 95+/-5 upright after treatment, P<.005 for supine and P<.01 for upright). Saline decreased both supine and upright HR (from 80+/-3 supine to 112+/-5 upright before infusion and from 77+/-3 supine to 91+/-3 upright 1 hour after infusion, P<.005 for supine and P<.001 for upright). Clonidine decreased supine HR (from 78+/-2 to 74+/-2, P<.03) but did not affect the HR increase with standing. Clonidine very significantly decreased supine systolic BP (from 109+/-3 at baseline to 99+/-2 mm Hg at 2 hours, P<.001), and midodrine decreased supine systolic BP mildly. CONCLUSIONS: IOT responds best acutely to saline infusion to correct the underlying hypovolemia. Chronically, this can be accomplished with increased salt and water intake in conjunction with fludrocortisone. The response of patients to the alpha1-agonist midodrine supports the hypothesis of partial dysautonomia and indicates that the use of alpha1-agonists to pharmacologically replace lower-extremity postganglionic sympathetics is an appropriate overall goal of therapy. These findings are consistent with our hypothesis that the tachycardia and elevated catecholamine levels associated with IOT are principally due to hypovolemia and loss of adequate lower-extremity vascular tone.

Non-NASA Center↗

Resistance exercise training and the orthostatic response

Resistance exercise has been suggested to increase blood volume, increase the sensitivity of the carotid baroreceptor cardiac reflex response (BARO), and decrease leg compliance, all factors that are expected to improve orthostatic tolerance. To further test these hypotheses, cardiovascular responses to standing and to pre-syncopal limited lower body negative pressure (LBNP) were measured in two groups of sedentary men before and after a 12-week period of either exercise (n = 10) or no exercise (control, n = 9). Resistance exercise training consisted of nine isotonic exercises, four sets of each, 3 days per week, stressing all major muscle groups. After exercise training, leg muscle volumes increased (P < 0.05) by 4-14%, lean body mass increased (P = 0.00) by 2.0 (0.5) kg, leg compliance and BARO were not significantly altered, and the maximal LBNP tolerated without pre-syncope was not significantly different. Supine resting heart rate was reduced (P = 0.03) without attenuating the heart rate or blood pressure responses during the stand test or LBNP. Also, blood volume (125I and 51Cr) and red cell mass were increased (P < 0.02) by 2.8% and 3.9%, respectively. These findings indicate that intense resistance exercise increases blood volume but does not consistently improve orthostatic tolerance.

NASA Discipline Musculoskeletal↗

Investigations of High Pressure Acoustic Waves in Resonators with Seal-Like Features

1) Standing waves with maximum pressures of 188 kPa have been produced in resonators containing ambient pressure air; 2) Addition of structures inside the resonator shifts the fundamental frequency and decreases the amplitude of the generated pressure waves; 3) Addition of holes to the resonator does reduce the magnitude of the acoustic waves produced, but their addition does not prohibit the generation of large magnitude non-linear standing waves; 4) The feasibility of reducing leakage using non-linear acoustics has been confirmed.

Daniels, Christopher C.↗

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight

Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.

Space Flight↗

Kinetics of cycle length dependence of ventricular repolarization: effect of autonomic blockade

INTRODUCTION: Beat-to-beat adaptation of ventricular repolarization duration to cardiac cycle length and autonomic activity has not been previously characterized in the spontaneously beating human heart. METHODS AND RESULTS: The ECG of 14 healthy subjects was recorded from the supine and upright positions. Autonomic blockade was accomplished by atropine and propranolol. RR and RT intervals were measured by a computer algorithm, and the impulse response (h) from RR to RT computed. In the supine position the maximal adjustment of the RT interval occurred in the first beat following a change in cycle length (hpeak = 17.8 +/- 1.6 msec/sec), but continued to be detectable for 3.8 seconds (2.9-4.7 sec). Propranolol attenuated the peak impulse response to 15.8 +/- 4.0 msec/sec (P = NS). In the standing position the peak impulse response was increased to 25.2 +/- 5.0 msec/sec (P = 0.004 vs supine), and the impulse response duration (hdur) shortened to 1.4 seconds (1.3-1.6). This was reversed by beta blockade (hpeak = 10.7 +/- 3.6 [P = 0.005 vs standing]; hdur = 5.5 sec [4.8-6.1]). Parasympathetic and combined autonomic blockade resulted in too little residual heart rate variability to estimate the impulse response accurately. The slope of the regression of delta RT and delta RR in the supine position was 0.0177 +/- 0.0016, which was closely correlated with the peak impulse response (r = 0.91). CONCLUSIONS: System identification techniques can assist in characterizing the cycle dependence of ventricular repolarization and may provide new insights into conditions associated with abnormal repolarization.

Clinical Trial↗

The role of haptic cues from rough and slippery surfaces in human postural control

Haptic information is critically important in complex sensory-motor tasks such as manipulating objects. Its comparable importance in spatial orientation is only beginning to be recognized. We have shown that postural sway in humans is significantly reduced by lightly touching a stable surface with a fingertip at contact force levels far below those physically necessary to stabilize the body. To investigate further the functional relationship between contact forces at the hand and postural equilibrium, we had subjects stand in the tandem Romberg stance while being allowed physically supportive (force contact) and non-physically supportive (touch contact) amounts of index fingertip force on surfaces with different frictional characteristics. Mean sway amplitude (MSA) was reduced by over 50% with both touch and force contact of the fingertip, compared to standing without fingertip contact. No differences in MSA were observed when touching rough or slippery surfaces. The amplitude of EMG activity in the peroneal muscles and the timing relationships between fingertip forces, body sway and EMG activity suggested that with touch contact of the finger or with force contact on a slippery surface long-loop "reflexes" involving postural muscles were stabilizing sway. With force contact of the fingertip on a rough surface, MSA reduction was achieved primarily through physical support of the body. This pattern of results indicates that light touch contact cues from the fingertip in conjunction with proprioceptive signals about arm configuration are providing information about body sway that can be used to reduce MSA through postural muscle activation.

NASA Discipline Neuroscience↗

Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers

Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.

NASA Discipline Musculoskeletal↗

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Acute hemodynamic responses to weightlessness in humans

As NASA designs space flights requiring prolonged periods of weightlessness for a broader segment of the population, it will be important to know the acute and sustained effects of weightlessness on the cardiovascular system since this information will contribute to understanding of the clinical pharmacology of drugs administered in space. Due to operational constraints on space flights, earliest effects of weightlessness have not been documented. We examined hemodynamic responses of humans to transitions from acceleration to weightlessness during parabolic flight on NASA's KC-135 aircraft. Impedance cardiography data were collected over four sets of 8-10 parabolas, with a brief rest period between sets. Each parabola included a period of 1.8 Gz, then approximately 20 seconds of weightlessness, and finally a period of 1.6 Gz; the cycle repeated almost immediately for the remainder of the set. Subjects were semi-supine (Shuttle launch posture) for the first set, then randomly supine, sitting and standing for each subsequent set. Transition to weightlessness while standing produced decreased heart rate, increased thoracic fluid content, and increased stroke index. Surprisingly, the onset of weightlessness in the semi-supine posture produced little evidence of a headward fluid shift. Heart rate, stroke index, and cardiac index are virtually unchanged after 20 seconds of weightlessness, and thoracic fluid content is slightly decreased. Semi-supine responses run counter to Shuttle crewmember reports of noticeable fluid shift after minutes to hours in orbit. Apparently, the headward fluid shift commences in the semi-supine posture before launch. is augmented by launch acceleration, but briefly interrupted immediately in orbit, then resumes and is completed over the next hours.

short duration↗

Theoretical Tools and Software for Modeling, Simulation and Control Design of Rocket Test Facilities

A rocket test stand and associated subsystems are complex devices whose operation requires that certain preparatory calculations be carried out before a test. In addition, real-time control calculations must be performed during the test, and further calculations are carried out after a test is completed. The latter may be required in order to evaluate if a particular test conformed to specifications. These calculations are used to set valve positions, pressure setpoints, control gains and other operating parameters so that a desired system behavior is obtained and the test can be successfully carried out. Currently, calculations are made in an ad-hoc fashion and involve trial-and-error procedures that may involve activating the system with the sole purpose of finding the correct parameter settings. The goals of this project are to develop mathematical models, control methodologies and associated simulation environments to provide a systematic and comprehensive prediction and real-time control capability. The models and controller designs are expected to be useful in two respects: 1) As a design tool, a model is the only way to determine the effects of design choices without building a prototype, which is, in the context of rocket test stands, impracticable; 2) As a prediction and tuning tool, a good model allows to set system parameters off-line, so that the expected system response conforms to specifications. This includes the setting of physical parameters, such as valve positions, and the configuration and tuning of any feedback controllers in the loop.

Richter, Hanz↗