Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLABS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

First-Principles Study of Casimir Repulsion in Metamaterials

We examine theoretically the Casimir effect between a metallic plate and several types of magnetic metamaterials in pursuit of Casimir repulsion, by employing a rigorous multiple-scattering theory for the Casimir effect. We first examine metamaterials in the form of two-dimensional lattices of inherently nonmagnetic spheres such as spheres made from materials possessing phonon-polariton and exciton-polariton resonances. Although such systems are magnetically active in infrared and optical regimes, the force between finite slabs of these materials and metallic slabs is plainly attractive since the effective electric permittivity is larger than the magnetic permeability for the studied spectrum. When lattices of magnetic spheres made from superparamagnetic composites are employed, we achieve not only Casimir repulsion but almost total suppression of the Casimir effect itself in the micrometer scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gyroid Phase in Nuclear Pasta

Nuclear matter is considered to be inhomogeneous at subnuclear densities that are realized in supernova cores and neutron star crusts, and the structures of nuclear matter change from spheres to cylinders, slabs, cylindrical holes, and spherical holes as the density increases. In this Letter, we discuss other possible structures, that is, gyroid and double-diamond morphologies, which are periodic bicontinuous structures discovered in a block copolymer. Utilizing the compressible liquid drop model, we show that there is a chance of gyroid appearance near the transition point from a cylinder to a slab and the volume fraction at this point is also similar for nuclear and polymer systems. Although the five shapes listed initially have been long thought to be the only major constituents of so-called nuclear pasta at subnuclear densities, our findings imply that this belief needs to be reconsidered.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin-lattice coupling in magnetocaloric Gd 5 ( Ge , Si ) 4 alloys by $in$ $situ$ x-ray pair distribution analysis in magnetic field

Here, using in situ x-ray pair distribution analysis in magnetic field, we study the strong spin-lattice coupling in archetypal magnetocaloric Gd 5 (Ge,Si) 4 alloys manifested by the presence of a first order paramagnetic (PM)-to-ferromagnetic (FM) phase transition that can be triggered by either decreasing temperature in zero magnetic field or increasing magnetic field at constant temperature. We find that the coupling arises from the tendency of Gd-(Si,Ge) slabs in the alloys to reversibly slide against each other to both pack closely and couple ferromagnetically. We also find that, locally, the packing of slabs in FM phases induced by decreasing temperature in zero field is different from that in FM phases of the same chemical composition induced by increasing magnetic field isothermally, indicating that temperature and magnetic field are coupled but not necessarily equivalent control variables for triggering phase transitions in strongly correlated systems.

36 MATERIALS SCIENCE↗

La 4 Co 4 X ( X = Pb , Bi , Sb ) : A demonstration of antagonistic pairs as a route to quasi-low-dimensional ternary compounds

We outline how pairs of strongly immiscible elements, referred to here as antagonistic pairs, can be used to synthesize ternary compounds with low or quasi-reduced-dimensional motifs intrinsically built into their crystal structures. By identifying third elements that are mutually compatible with a given antagonistic pair, ternary compounds can be formed in which the third element segregates the immiscible atoms into spatially separated substructures. Quasi-low-dimensional structural units, such as sheets, chains, or clusters are a natural consequence of the immiscible atoms seeking to avoid close contact in the solid state. Further, as proof of principle, we present the discovery, crystal growth, and basic physical properties of La 4 ⁢Co 4 ⁢$\mathrm{X}$ (X = Pb, Bi, Sb), a family of intermetallic compounds based on the antagonistic pairs Co-Pb and Co-Bi. La 4 ⁢Co 4 ⁢$\mathrm{X}$ adopts an orthorhombic crystal structure (space group Pbam) containing quasi-two-dimensional Co slabs and La-X polyhedra that stack in an alternating manner along the α axis. Consistent with our proposal, the La atoms separate the Co and X substructures, ensuring there are no direct contacts between the members of the immiscible (antagonistic) pair. Within the Co slabs, the atoms occupy the vertices of corner sharing tetrahedra and triangles, and this bonding motif produces narrow electronic bands near the Fermi level that favor magnetism. The Co is moment bearing in each La 4 ⁢Co 4 $\mathrm{X}$ compound studied, and we show that whereas La 4 ⁢Co 4 ⁢Pb behaves as a three-dimensional antiferromagnet with T N =220K, La 4 ⁢Co 4 ⁢Bi and La 4⁢ Co 4 ⁢Sb have behavior consistent with low-dimensional magnetic coupling and ordering, with T N =153K and 143 K, respectively. In addition to the Pb-, Bi-, and Sb-based La 4 ⁢Co 4 ⁢$\mathrm{X}$ compounds, we also were likely able to produce an analogous La 4 ⁢Co 4 ⁢Sn in polycrystalline form, although we were unable to isolate single crystals. We anticipate that identifying and using mutually compatible third elements together with an antagonistic pair represents a generalizable design principle for discovering new materials and new structure types containing low-dimensional substructures.

36 MATERIALS SCIENCE↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Model-Free State Estimation Using Low-Rank Canonical Polyadic Decomposition

As electric grids experience high penetration levels of renewable generation, fundamental changes are required to address real-time situational awareness. Here, we utilize unique traits of tensors to devise a model-free situational awareness and energy forecasting framework for distribution networks. This work formulates the state of the network at multiple time instants as a three-way tensor; hence, recovering full state information of the network is tantamount to estimating all the values of the tensor. Given measurements received from µphasor measurement units and/or smart meters, the recovery of unobserved quantities is carried out using the low-rank canonical polyadic decomposition of the state tensor—that is, the state estimation task is posed as a tensor imputation problem utilizing observed patterns in measured (sampled) quantities. Two structured sampling schemes are considered, namely, asynchronous slab and fiber sampling. For both schemes, we present sufficient conditions on the number of sampled slabs and fibers that guarantee identifiability of the factors of the state tensor. Numerical results demonstrate the ability of the proposed framework to achieve high estimation accuracy in multiple sampling scenarios.

42 ENGINEERING↗

Plasma Jet Formation Disruption From a Critical Applied Uniform Axial Magnetic Field

We examine the effects of varying the magnitude of an applied, uniform, axial magnetic field (Bz) on the formation of laboratory plasma jets produced by a 1-MA 100-ns rise time pulsed power generator in a radial foil configuration. A Helmholtz coil applies the external magnetic field (0 to 2 T). With a small-enough applied field, the foil surface ablation is relatively azimuthally uniform, and J×B forces drive the ablated plasma inward and upward to form a well-defined azimuthally symmetric jet. Using applied field strengths larger than a critical Bz = 1.1±0.1 T with aluminum foils, the plasma ablation is not azimuthally uniform, discrete bursts of plasma initiate from the foil surface, and the formation of a well-defined jet is disrupted. The critical Bz for this plasma jet formation disruption correlates with the foil material’s electrical resistivity and equation of state (EOS). To better understand the material-dependent phenomenon, we compare the experimental results with 3-D extended magnetohydrodynamics simulations of ablation of a 2 mm × 2 mm by 25-μm slab that represents a section of the radial foil. The simulations initialize the slab in the solid state and include the material resistivity and EOS from the solid to plasma phases. As is observed in the experimental disruption, these simulations show enhanced nonuniform plasma ablation with an applied Bz, which can inhibit the azimuthal uniformity necessary to produce a well-defined plasma jet. Furthermore, the simulations also show a material and resistivity dependence on the ablation process similar to the trend shown by the experiments. These results demonstrate the necessity of accurate, detailed modeling of material properties during the transition from solid to plasma phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of slot scanning digital mammography system with full-field digital mammography system

The purpose of this study was to evaluate and compare microcalcification detectability of two commercial full-field digital mammography (DM) systems. The first unit was a flat panel based DM system (FFDM) which employed an anti-scatter grid method to reject scatter, and the second unit was a charge-coupled device-based DM system (SSDM) which used scanning slot imaging geometry to reduce scatter radiation. Both systems have comparable scatter-to-primary ratios. In this study, 125-160 and 200-250 {mu}m calcium carbonate grains were used to simulate microcalcifications and imaged by both DM systems. The calcium carbonate grains were overlapped with a 5-cm-thick 50% adipose/50% glandular simulated breast tissue slab and an anthropomorphic breast phantom (RMI 165, Gammex) for imaging at two different mean glandular dose levels: 0.87 and 1.74 mGy. A reading study was conducted with seven board certified mammographers with images displayed on review workstations. A five-point confidence level rating was used to score each detection task. Receiver operating characteristic (ROC) analysis was performed and the area under the ROC curve (A{sub z}) was used to quantify and compare the performances of these two systems. The results showed that with the simulated breast tissue slab (uniform background), the SSDM system resulted in higher A{sub z}'s than the FFDM system at both MGD levels with the difference statistically significant at 0.87 mGy only. With the anthropomorphic breast phantom (tissue structure background), the SSDM system performed better than the FFDM system at 0.87 mGy but worse at 1.74 mGy. However, the differences were not found to be statistically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo evaluation of the convolution/superposition algorithm of Hi-Art tomotherapy in heterogeneous phantoms and clinical cases

The reliability of the convolution/superposition (C/S) algorithm of the Hi-Art tomotherapy system is evaluated by using the Monte Carlo model TomoPen, which has been already validated for homogeneous phantoms. The study was performed in three stages. First, measurements with EBT Gafchromic film for a 1.25x2.5 cm{sup 2} field in a heterogeneous phantom consisting of two slabs of polystyrene separated with Styrofoam were compared to simulation results from TomoPen. The excellent agreement found in this comparison justifies the use of TomoPen as the reference for the remaining parts of this work. Second, to allow analysis and interpretation of the results in clinical cases, dose distributions calculated with TomoPen and C/S were compared for a similar phantom geometry, with multiple slabs of various densities. Even in conditions of lack of lateral electronic equilibrium, overall good agreement was obtained between C/S and TomoPen results, with deviations within 3%/2 mm, showing that the C/S algorithm accounts for modifications in secondary electron transport due to the presence of a low density medium. Finally, calculations were performed with TomoPen and C/S of dose distributions in various clinical cases, from large bilateral head and neck tumors to small lung tumors with diameter of <3 cm. To ensure a ''fair'' comparison, identical dose calculation grid and dose-volume histogram calculator were used. Very good agreement was obtained for most of the cases, with no significant differences between the DVHs obtained from both calculations. However, deviations of up to 4% for the dose received by 95% of the target volume were found for the small lung tumors. Therefore, the approximations in the C/S algorithm slightly influence the accuracy in small lung tumors even though the C/S algorithm of the tomotherapy system shows very good overall behavior.

61 RADIATION PROTECTION AND DOSIMETRY↗

Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors

In a previous study [Med. Phys. 35, 1747-1755 (2008)], the authors proposed two direct methods of calculating the replacement correction factors (P{sub repl} or p{sub cav}p{sub dis}) for ion chambers by Monte Carlo calculation. By ''direct'' we meant the stopping-power ratio evaluation is not necessary. The two methods were named as the high-density air (HDA) and low-density water (LDW) methods. Although the accuracy of these methods was briefly discussed, it turns out that the assumption made regarding the dose in an HDA slab as a function of slab thickness is not correct. This issue is reinvestigated in the current study, and the accuracy of the LDW method applied to ion chambers in a {sup 60}Co photon beam is also studied. It is found that the two direct methods are in fact not completely independent of the stopping-power ratio of the two materials involved. There is an implicit dependence of the calculated P{sub repl} values upon the stopping-power ratio evaluation through the choice of an appropriate energy cutoff {Delta}, which characterizes a cavity size in the Spencer-Attix cavity theory. Since the {Delta} value is not accurately defined in the theory, this dependence on the stopping-power ratio results in a systematic uncertainty on the calculated P{sub repl} values. For phantom materials of similar effective atomic number to air, such as water and graphite, this systematic uncertainty is at most 0.2% for most commonly used chambers for either electron or photon beams. This uncertainty level is good enough for current ion chamber dosimetry, and the merits of the two direct methods of calculating P{sub repl} values are maintained, i.e., there is no need to do a separate stopping-power ratio calculation. For high-Z materials, the inherent uncertainty would make it practically impossible to calculate reliable P{sub repl} values using the two direct methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CT energy weighting in the presence of scatter and limited energy resolution

Purpose: Energy-resolved CT has the potential to improve the contrast-to-noise ratio (CNR) through optimal weighting of photons detected in energy bins. In general, optimal weighting gives higher weight to the lower energy photons that contain the most contrast information. However, low-energy photons are generally most corrupted by scatter and spectrum tailing, an effect caused by the limited energy resolution of the detector. This article first quantifies the effects of spectrum tailing on energy-resolved data, which may also be beneficial for material decomposition applications. Subsequently, the combined effects of energy weighting, spectrum tailing, and scatter are investigated through simulations. Methods: The study first investigated the effects of spectrum tailing on the estimated attenuation coefficients of homogeneous slab objects. Next, the study compared the CNR and artifact performance of images simulated with varying levels of scatter and spectrum tailing effects, and reconstructed with energy integrating, photon-counting, and two optimal linear weighting methods: Projection-based and image-based weighting. Realistic detector energy-response functions were simulated based on a previously proposed model. The energy-response functions represent the probability that a photon incident on the detector at a particular energy will be detected at a different energy. Realistic scatter was simulated with Monte Carlo methods. Results: Spectrum tailing resulted in a negative shift in the estimated attenuation coefficient of slab objects compared to an ideal detector. The magnitude of the shift varied with material composition, increased with material thickness, and decreased with photon energy. Spectrum tailing caused cupping artifacts and CT number inaccuracies in images reconstructed with optimal energy weighting, and did not impact images reconstructed with photon counting weighting. Spectrum tailing did not significantly impact the CNR in reconstructed images. Scatter reduced the CNR for all energy-weighting methods; however, the effect was greater for optimal energy weighting. For example, optimal energy weighting improved the CNR of iodine and water compared to energy-integrating weighting by a factor of {approx}1.45 in the absence of scatter and by a factor of {approx}1.1 in the presence of scatter (8.9 deg. cone angle, SPR 0.5). Without scatter correction, the difference in CNR resulting from photon-counting and optimal energy weighting was negligible (<15%) for cone angles greater than 4.4 deg. (SPR>0.3). Optimal weights combined with deterministic scatter correction provided a 1.3 and 1.1 improvement in CNR compared to energy-integrating and photon-counting weighting, respectively, for the 8.9 deg. cone angle simulation. In the absence of spectrum tailing, image-based weighting demonstrated reduced cupping artifact compared to projection-based weighting; however, both weighting methods exhibited similar cupping artifacts when spectrum tailing was simulated. There were no statistically significant differences in the CNR resulting from projection and image-based weighting for any of the simulated conditions. Conclusions: Optimal linear energy weighting introduces artifacts and CT number inaccuracies due to spectrum tailing. While optimal energy weighting has the potential to improve CNR compared to conventional weighting methods, the benefits are reduced as scatter increases. Efficient methods for reducing scatter and correcting spectrum tailing effects are required to obtain the highest benefit from optimal energy weighting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface applicator calibration and commissioning of an electronic brachytherapy system for nonmelanoma skin cancer treatment

Purpose: The Xoft Axxent x-ray source has been used for treating nonmelanoma skin cancer since the surface applicators became clinically available in 2009. The authors report comprehensive calibration procedures for the electronic brachytherapy (eBx) system with the surface applicators. Methods: The Xoft miniature tube (model S700) generates 50 kVp low-energy x rays. The new surface applicators are available in four sizes of 10, 20, 35, and 50 mm in diameter. The authors' tests include measurements of dose rate, air-gap factor, output stability, depth dose verification, beam flatness and symmetry, and treatment planning with patient specific cutout factors. The TG-61 in-air method was used as a guideline for acquiring nominal dose-rate output at the skin surface. A soft x-ray parallel-plate chamber (PTW T34013) and electrometer was used for the output commissioning. GafChromic EBT films were used for testing the properties of the treatment fields with the skin applicators. Solid water slabs were used to verify the depth dose and cutout factors. Patients with basal cell or squamous cell carcinoma were treated with eBx using a calibrated Xoft system with the low-energy x-ray source and the skin applicators. Results: The average nominal dose-rate output at the skin surface for the 35 mm applicator is 1.35 Gy/min with {+-}5% variation for 16 sources. The dose-rate output and stability (within {+-}5% variation) were also measured for the remaining three applicators. For the same source, the output variation is within 2%. The effective source-surface distance was calculated based on the air-gap measurements for four applicator sizes. The field flatness and symmetry are well within 5%. Percentage depth dose in water was provided by factory measurements and can be verified using solid water slabs. Treatment duration was calculated based on the nominal dose rate, the prescription fraction size, the depth dose percentage, and the cutout factor. The output factor needs to be measured for each case with varying shapes of cutouts. Conclusions: Together with TG-61, the authors' methodology provides comprehensive calibration procedures for medical physicists for using the Xoft eBx system and skin applicators for nonmelanoma skin cancer treatments.

60 APPLIED LIFE SCIENCES↗

Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm

Purpose: A method to perform transit dosimetry with an electronic portal imaging device (EPID) by extending the commercial implementation of a published through-air portal dose image (PDI) prediction algorithm Van Esch et al.[Radiother. Oncol. 71, 223-234 (2004)] is proposed and validated. A detailed characterization of the attenuation, scattering, and EPID response behind objects in the beam path is used to convert through-air PDIs into transit PDIs. Methods: The EPID detector response beyond a range of water equivalent thicknesses (0-35 cm) and field sizes (3x3 to 22.2x29.6 cm{sup 2}) was analyzed. A constant air gap between the phantom exit surface and the EPID was utilized. A model was constructed that accounts for the beam's attenuation along the central axis, the presence of phantom scattered radiation, the detector's energy dependent response, and the difference in EPID off-axis pixel response relative to the central pixel. The efficacy of the algorithm was verified by comparing predicted and measured PDIs for IMRT fields delivered through phantoms of increasing complexity. Results: The expression that converts a through-air PDI to a transit PDI is dependent on the object's thickness, the irradiated field size, and the EPID pixel position. Monte Carlo derived narrow-beam linear attenuation coefficients are used to model the decrease in primary fluence incident upon the EPID due to the object's presence in the beam. This term is multiplied by a factor that accounts for the broad beam scatter geometry of the linac-phantom-EPID system and the detector's response to the incident beam quality. A 2D Gaussian function that models the nonuniformity of pixel response across the EPID detector plane is developed. For algorithmic verification, 49 IMRT fields were repeatedly delivered to homogeneous slab phantoms in 5 cm increments. Over the entire set of measurements, the average area passing a 3%/3mm gamma criteria slowly decreased from 98% for no material in the beam to 96.7% for 35 cm of material in the beam. The same 49 fields were delivered to a heterogeneous slab phantom and on average, 97.1% of the pixels passed the gamma criteria. Finally, a total of 33 IMRT fields were delivered to the anthropomorphic phantom and on average, 98.1% of the pixels passed. The likelihood of good matches was independent of anatomical site. Conclusions: A prediction of the transit PDI behind a phantom or patient can be created for the purposes of treatment verification via an extension of the Van Esch through-air PDI algorithm. The results of the verification measurements through phantoms indicate that further investigation through patients during their treatments is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Improved implementation of doppler broadening in MCNP5

Purpose: Incoherent scattering has a substantial effect on spectroscopic measurements and simulations. Many general-purpose Monte Carlo codes include models that account for the effects of bound electrons on incoherent scattering, including Doppler broadening (DB). This work investigates the DB model used in the Monte Carlo N-particle transport code (MCNP5). Methods: Simulations were run with three versions of MCNP5: v1.51, v1.60, and a modified form of v1.60 (v1.60m). All simulations used the MCPLIB04 photon data library, which presents the electron subshell data for incoherent scattering in the form of a probability density function. In v1.60m, the source code was altered to sample the electron subshell from a cumulative density function instead. Each version of the code was tested using an identical set of simulations that investigated DB in a slab of silicon at scattering angles of 15 Degree-Sign , 30 Degree-Sign , and 45 Degree-Sign . For each angle, simulations were run for multiple energies between 200 keV and 800 keV. The spectrum of singly-scattered photons at the exit of the slab was scored. Spectra were analytically calculated for comparison. Results: In v1.51, DB was modeled for incident photon energies below 760 keV, 384 keV, and 260 keV at scattering angles of 15 Degree-Sign , 30 Degree-Sign , and 45 Degree-Sign , respectively. Above these energy thresholds, v1.51 did not model DB. The spectra calculated using v1.60 and v1.60m exhibited DB for all energy-angle combinations; however, v1.60m, exhibited more energy broadening than did v1.60. The spectra calculated with v1.60m agreed with the analytical calculations. Conclusions: MCNP5 v1.51 and v1.60 model partial broadening when used with the MCPLIB04 data library. MCNP5 v1.60m models DB more accurately due to the form of the electron subshell data. In response to these results, Los Alamos National Laboratory has released a new photon data library, MCPLIB84, that presents the electron subshell data in cumulative distribution form. MCNP5 v1.60 should be used with this library when incoherent scattering has a significant impact on simulation results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-12A-04: Investigation of a 2D Antiscatter Grid for Flat Panel Detectors

Purpose: To improve CT number accuracy and contrast sensitivity, a novel 2D antiscatter grid (ASG) for flat panel detector (FPD) based CBCT imaging was evaluated. Experiments were performed to characterize the scatter rejection and contrast sensitivity performance of ASG. The reduction in primary transmission for various ASG geometries was also evaluated by a computational model. Methods: The 2D ASG design was based on multi-hole collimators used in Nuclear Medicine. It consisted of abutted hexagon shaped apertures with 2.5 mm pitch and 32 mm height, and separated by 0.25 mm thick lead septa. Scatter-to-primary ratio (SPR), contrast-to-noise ratio (CNR), and mean primary transmission were measured using a benchtop FPD/x-ray source system. Acrylic slabs of varying thicknesses were imaged with a contrast-detail phantom to measure CNR and SPR under different scatter conditions. Primary transmission was also measured by averaging pixel values in flood field images without the phantom. We additionally explored variation of primary transmission with pitch and septum thickness using a computational model of our ASG. Results: Our 2D ASG reduced the SPR from 3.3 to 0.12, and improved CNR by 50% in 20 cm thick slab phantom projections acquired at 120 kVp. While the measured primary transmission was 72.8%, our simulations show that primary transmission can be increased to 86% by reducing the septum thickness to 0.1 mm. Primary transmission further increases to 93% if septum thickness of 0.1 mm is used in conjunction with an increased pitch of 4 mm. Conclusion: The 2D ASG appears to be a promising scatter rejection device, offering both superior scatter rejection and improved contrast sensitivity. Though its lead footprint reduced primary transmission, our work shows that optimization of aperture pitch and septum thickness can significantly improve the primary transmission.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-01: A Fast, Analytical Pencil Beam Based Method for First Order X-Ray Scatter Estimation of Kilovoltage Cone Beam X-Rays

Purpose: To analytically estimate first-order x-ray scatter for kV cone beam x-ray imaging with high computational efficiency. Methods: In calculating first-order scatter using the Klein-Nishina formula, we found that by integrating the point-to-point scatter along an interaction line, a “pencil-beam” scatter kernel (BSK) can be approximated to a quartic expression when the imaging field is small. This BSK model for monoenergetic, 100keV x-rays has been verified on homogeneous cube and cylinder water phantoms by comparing with the exact implementation of KN formula. For heterogeneous medium, the water-equivalent length of a BSK was acquired with an improved Siddon's ray-tracing algorithm, which was also used in calculating pre- and post- scattering attenuation. To include the electron binding effect for scattering of low-kV photons, the mean corresponding scattering angle is determined from the effective point of scattered photons of a BSK. The behavior of polyenergetic x-rays was also investigated for 120kV x-rays incident to a sandwiched infinite heterogeneous slab phantom, with the electron binding effect incorporated. Exact computation and Monte Carlo simulations were performed for comparisons, using the EGSnrc code package. Results: By reducing the 3D volumetric target (o(n{sup 3})) to 2D pencil-beams (o(n{sup 2})), the computation expense can be generally lowered by n times, which our experience verifies. The scatter distribution on a flat detector shows high agreement between the analytic BSK model and exact calculations. The pixel-to-pixel differences are within (-2%, 2%) for the homogeneous cube and cylinder phantoms and within (0, 6%) for the heterogeneous slab phantom. However, the Monte Carlo simulation shows increased deviation of the BSK model toward detector periphery. Conclusion: The proposed BSK model, accommodating polyenergetic x-rays and electron binding effect at low kV, shows great potential in efficiently estimating the first-order scatter from small imaging fields. We are investigating more thoroughly to improve performance and explore applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-164: Evaluation of Electron Dose Distribution Using Two Algorithms

Purpose: To appreciate the difference of electron dose distributions calculated from the Monte Carlo and Electron 3D algorithms of radiotherapy in a heterogeneous phantom. Methods: A phantom consisted of two different materials (lungs mimicked by low-density cork and others by polystyrene) with an 11x16 cm field size (SSD = 100 cm) was utilized to estimate the two-dimensional dose distributions under 6 and 18 MeV beams. On behalf of two different types of tissue, the heterogeneous phantom was comprised of 3 identical slabs in the longitudinal direction with a thickness of 1 cm for each slab and 2 with a thickness of 2.5 cm. The Monte Carlo/MCTP application package constituted of five codes was performed to simulate the electron beams of a Varian Clinac 23IX. A 20x20 cm2 type III (open walled) applicator was used in these simulations. It has been shown elsewhere that the agreement of the phase space data between the calculation results of MCTP application package and the measured data were within 2% on depth-dose and transverse profiles, as well as output factor calculations. The electron 3D algorithm owned by Pinnacle 8.0m and the MCTP application package were applied for the two-dimensional dose distributions calculation. The curves at 50% and 100%-prescribed dose were observed for 6 and 18 MeV beams, respectively. Results: The MC calculations results were compared with the electron 3D calculations in terms of two-dimensional dose distributions for 6 and 18 MeV beams showed excellent agreement except in distal boundary where it was the very junction of the high and low-density region. Conclusions: The Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues. Conclusion: A case study showed that the Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues.

60 APPLIED LIFE SCIENCES↗

SU-E-T-165: Evaluation of Inhomogeneity Calculations for Electron Beams in Raystation Monte Carlo Algorithm

Purpose: To evaluate the accuracy of the Raystation electron Monte Carlo algorithm for bone and air inhomogeneity. Methods: A solid water phantom slab was drilled to contain two openings of 1.3cm diameter, 0.6cm apart. The center of the opening is at 1cm depth from the surface. Two Teflon rods of exact same diameter were inserted to investigate bone inhomogeneity. Slab is 2cm total in thickness and was placed on top of 10cm solid water. Plans were created in Raystation with clinical settings previously established for 6, 9, 12, 15 and 18MeV Elekta Infinity beams. Coronal profiles were extracted posteriorly to the inhomogeneity. EBT3 films were irradiated under the same conditions and analyzed using FilmQAPro using the red channel. Calibration films were used for all energies. Same plans and films were performed for a Varian accelerator with same energies and Eclipse Monte Carlo. Results: Air Inhomogeneities: For lower energies, Raystation- Film agreement is less than 1% for the regions of the air cavity. In the lateral interface border, Raystation underestimates dose by approximately 2%. Eclipse results are similar. For higher energies, Raystation-Film agreement remains the same across the air cavity and interface. Eclipse-Film difference increases with energy up to 5% for 18MeV, with Eclipse calculating higher doses than the film at the interface. Bone Inhomogeneities: For lower energies, Raystation underestimates the dose behind the bone up to 12%. Eclipse underestimates the dose in the same area up to 18%. For higher energies, the dose difference behind the bone decreases to 1% for Raystation and 3% for Eclipse. At the lateral interface, Raystation underestimates the dose by 2.2% and Eclipse underestimates the dose by 5%. Conclusion: Raystation prediction for air and bone is acceptable. Maximum deviations are consistent with algorithm limitations. Differences between calculations and measurement are closer for Raystation than for Eclipse.

60 APPLIED LIFE SCIENCES↗