Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Line scanning thermography for rapid nondestructive inspection of large scale composites

As next generation structures are utilizing larger amounts of composite materials, a rigorous and reliable method is needed to inspect these structures in order to prevent catastrophic failure and extend service life. Current inspection methods, such as ultrasonic, generally require extended down time and man hours as they are typically carried out via point-by-point measurements. A novel Line Scanning Thermography (LST) System has been developed for the non-contact, large-scale field inspection of composite structures with faster scanning times than conventional thermography systems. LST is a patented dynamic thermography technique where the heat source and thermal camera move in tandem, which allows the continuous scan of long surfaces without the loss of resolution. The current system can inspect an area of 10 in{sup 2} per 1 second, and has a resolution of 0.05x0.03 in{sup 2}. Advanced data gathering protocols have been implemented for near-real time damage visualization and post-analysis algorithms for damage interpretation. The system has been used to successfully detect defects (delamination, dry areas) in fiber-reinforced composite sandwich panels for Navy applications, as well as impact damage in composite missile cases and armor ceramic panels.

42 ENGINEERING↗

Simultaneous translational temperature measurements of different atomic species in plasma flows using scanning Fabry-Perot interferometry

A revised scientific instrument to measure simultaneously kinetic temperatures of different atoms from their optical emission profile is reported. Emission lines are simultaneously detected using one single scanning Fabry-Perot-interferometer (FPI) for a combined spectroscopic setup to acquire different emission lines simultaneously. The setup consists in a commercial Czerny-Turner spectrometer configuration which is combined with a scanning Fabry-Perot interferometer. The fast image acquisition mode of an intensified charge coupled device camera allows the detection of a wavelength interval of interest continuously while acquiring the highly resolved line during the scan of the FPI ramp. Results using this new setup are presented for the simultaneous detection of atomic nitrogen and oxygen in a high enthalpy air plasma flow as used for atmospheric re-entry research and their respective kinetic temperatures derived from the measured line profiles. The paper presents the experimental setup, the calibration procedure, and an exemplary result. The determined temperatures are different, a finding that has been published so far as due to a drawback of the experimental setup of sequential measurements, and which has now to be investigated in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of grain boundary conductivity of spin-sprayed ferrites using scanning microwave microscope

Grain boundary electrical conductivity of ferrite materials has been characterized using scanning microwave microscope. Structural, electrical, and magnetic properties of Fe{sub 3}O{sub 4} spin-sprayed thin films onto glass substrates for different length of growth times were investigated using a scanning microwave microscope, an atomic force microscope, a four-point probe measurement, and a made in house transmission line based magnetic permeameter. The real part of the magnetic permeability shows almost constant between 10 and 300 MHz. As the Fe{sub 3}O{sub 4} film thickness increases, the grain size becomes larger, leading to a higher DC conductivity. However, the loss in the Fe{sub 3}O{sub 4} films at high frequency does not increase correspondingly. By measuring the reflection coefficient s{sub 11} from the scanning microwave microscope, it turns out that the grain boundaries of the Fe{sub 3}O{sub 4} films exhibit higher electric conductivity than the grains, which contributes loss at radio frequencies. This result will provide guidance for further improvement of low loss ferrite materials for high frequency applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Laser beam scanning using a ferroelectric liquid crystal spatial light modulator

In this work we describe laser beam scanning using a ferroelectric liquid crystal spatial light modulator. Commercially available ferroelectric liquid crystal spatial light modulators are capable of displaying 85 colored images in 1 s using a time dithering technique. Each colored image, in fact, comprises 24 single bit (black and white) images displayed sequentially. We have used each single bit image to write a binary phase hologram. For a collimated laser beam incident on the hologram, one of the diffracted beams can be made to travel along a user defined direction. We have constructed a beam scanner employing the above arrangement and demonstrated its use to scan a single laser beam in a laser scanning optical sectioning microscope setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast dark-field surface inspection with hybrid-dispersion laser scanning

High-speed surface inspection plays an important role in industrial manufacturing, safety monitoring, and quality control. It is desirable to go beyond the speed limitation of current technologies for reducing manufacturing costs and opening a new window onto a class of applications that require high-throughput sensing. Here, we report a high-speed dark-field surface inspector for detection of micrometer-sized surface defects that can travel at a record high speed as high as a few kilometers per second. This method is based on a modified time-stretch microscope that illuminates temporally and spatially dispersed laser pulses on the surface of a fast-moving object and detects scattered light from defects on the surface with a sensitive photodetector in a dark-field configuration. The inspector's ability to perform ultrafast dark-field surface inspection enables real-time identification of difficult-to-detect features on weakly reflecting surfaces and hence renders the method much more practical than in the previously demonstrated bright-field configuration. Consequently, our inspector provides nearly 1000 times higher scanning speed than conventional inspectors. To show our method's broad utility, we demonstrate real-time inspection of the surface of various objects (a non-reflective black film, transparent flexible film, and reflective hard disk) for detection of 10 μm or smaller defects on a moving target at 20 m/s within a scan width of 25 mm at a scan rate of 90.9 MHz. Our method holds promise for improving the cost and performance of organic light-emitting diode displays for next-generation smart phones, lithium-ion batteries for green electronics, and high-efficiency solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced method to reconstruct mode shapes of continuous scanning measurements using the Hilbert Huang transform and the modal analysis method

Generally, it is time consuming to experimentally identify the operating deflection shape or mode shape of a structure. To overcome this problem, the Hilbert Huang transform (HHT) technique has been recently proposed. This technique is used to extract the mode shape from measurements that continuously measure the vibration of a region of interest within a structure using a non-contact laser sensor. In previous research regarding the HHT, two technical processes were needed to obtain the mode shape for each mode. The purpose of this study is to improve and complement our previous research, and for this purpose, a modal analysis approach is adapted without using the two technical processes to obtain an accurate un-damped impulse response of each mode for continuous scanning measurements. In addition, frequency response functions for each type of beam are derived, making it possible to make continuously scanned measurements along a straight profile. In this paper, the technical limitations and drawbacks of the damping compensation technique used in previous research are identified. In addition, the separation of resonant frequency (the Doppler effect) that occurs in continuous scanning measurements and the separation of damping phenomenon are also observed. The proposed method is quantitatively verified by comparing it with the results obtained from a conventional approach to estimate the mode shape with an impulse response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graphitization of polymer surfaces by scanning ion irradiation

Graphitization of polymer surfaces was performed by low-energy Ar{sup +} and He{sup +} ion irradiation. A method of scanning irradiation was implemented. It was found that by scanning ion irradiation, a significantly higher electrical conductivity in the graphitized layers can be achieved in comparison with a conventional broad-beam irradiation. The enhancement of the conductance becomes more pronounced for narrower and better collimated ion beams. In order to analyze these results in more detail, the temperature dependence of conductance of the irradiated samples was investigated. The results of measurements are discussed in terms of weak localization corrections to conductance in disordered metals. The observed effects can be explained by enlargement of graphitic patches, which was achieved with the scanning ion irradiation method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

White light Z-scan measurements of ultrafast optical nonlinearity in reduced graphene oxide nanosheets in the 400–700 nm region

Wavelength dispersion of optical power limiting is an important factor to be considered while designing potential optical limiters for laser safety applications. We report the observation of broadband, ultrafast optical limiting in reduced graphene oxide (rGO), measured by a single open aperture Z-scan using a white light continuum (WLC) source. WLC Z-scan is fast when the nonlinearity is to be measured over broad wavelength ranges, and it obviates the need for an ultrafast tunable laser making it cost-economic compared to conventional Z-scan. The nonlinearity arises from nondegenerate two-photon absorption, owing mostly to the crystallinity and extended π conjugation of rGO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a detachable high speed miniature scanning probe microscope for large area substrates inspection

We have developed a high speed, miniature scanning probe microscope (MSPM) integrated with a Positioning Unit (PU) for accurately positioning the MSPM on a large substrate. This combination enables simultaneous, parallel operation of many units on a large sample for high throughput measurements. The size of the MSPM is 19 × 45 × 70 mm{sup 3}. It contains a one-dimensional flexure stage with counter-balanced actuation for vertical scanning with a bandwidth of 50 kHz and a z-travel range of more than 2 μm. This stage is mechanically decoupled from the rest of the MSPM by suspending it on specific dynamically determined points. The motion of the probe, which is mounted on top of the flexure stage is measured by a very compact optical beam deflection (OBD). Thermal noise spectrum measurements of short cantilevers show a bandwidth of 2 MHz and a noise of less than 15 fm/Hz{sup 1/2}. A fast approach and engagement of the probe to the substrate surface have been achieved by integrating a small stepper actuator and direct monitoring of the cantilever response to the approaching surface. The PU has the same width as the MSPM, 45 mm and can position the MSPM to a pre-chosen position within an area of 275×30 mm{sup 2} to within 100 nm accuracy within a few seconds. During scanning, the MSPM is detached from the PU which is essential to eliminate mechanical vibration and drift from the relatively low-resonance frequency and low-stiffness structure of the PU. Although the specific implementation of the MSPM we describe here has been developed as an atomic force microscope, the general architecture is applicable to any form of SPM. This high speed MSPM is now being used in a parallel SPM architecture for inspection and metrology of large samples such as semiconductor wafers and masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging ballistic carrier trajectories in graphene using scanning gate microscopy

We use scanning gate microscopy to map out the trajectories of ballistic carriers in high-mobility graphene encapsulated by hexagonal boron nitride and subject to a weak magnetic field. We employ a magnetic focusing geometry to image carriers that emerge ballistically from an injector, follow a cyclotron path due to the Lorentz force from an applied magnetic field, and land on an adjacent collector probe. The local electric field generated by the scanning tip in the vicinity of the carriers deflects their trajectories, modifying the proportion of carriers focused into the collector. By measuring the voltage at the collector while scanning the tip, we are able to obtain images with arcs that are consistent with the expected cyclotron motion. We also demonstrate that the tip can be used to redirect misaligned carriers back to the collector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear optical characterization of graphite oxide thin film by open aperture Z-scan technique

In this paper we explore the structural characterization of graphite oxide powder prepared from graphite powder by oxidation via modified Hummers method. The nonlinear optical properties of the spin coated graphite oxide thin film is also explored by open aperture Z-Scan technique. Structural and physiochemical properties of the samples were investigated with the help of Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopy (Raman).The results of FT-IR and Raman spectroscopy showed that the graphite is oxidized by strong oxidants and the oxygen atoms are introduced into the graphite layers forming C=C, O-H and –C-H groups. The synthesized sample has good crystalline nature with lesser defects. The nonlinear optical property of GO thin film was studied by open aperture Z-Scan technique using Q-switched Nd-Yag Laser at 532 nm. The Z-scan plot showed that the investigated GO thin film has saturable absorption behavior. The nonlinear absorption coefficient and saturation intensity were also estimated to explore its applications in Q switched mode locking laser systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Composition analysis of coaxially grown InGaN multi quantum wells using scanning transmission electron microscopy

GaN nanotubes with coaxial InGaN quantum wells were analyzed by scanning transmission electron microscopy in order to determine their structural properties as well as the indium distribution across the InGaN quantum wells. For the latter, two process steps are necessary. First, a technique to prepare cross-sectional slices out of the nanotubes has been developed. Second, an existing scanning transmission electron microscopy analysis technique has been extended with respect to the special crystallographic orientation of this type of specimen. In particular, the shape of the nanotubes, their defect structure, and the incorporation of indium on different facets were investigated. The quantum wells preferentially grow on m-planes of the dodecagonally shaped nanotubes and on semipolar top facets while no significant indium signal was found on a-planes. An averaged indium concentration of 6% to 7% was found by scanning transmission electron microscopy analysis and could be confirmed by cathodoluminescence measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

A scanning angle energy-dispersive X-ray diffraction technique for high-pressure structure studies in diamond anvil cells

A scanning angle diffraction technique with an energy-dispersive solid-state detector (SSD) and white synchrotron radiation has been developed for high-pressure structure studies in diamond anvil cells (DACs). This technique is similar to the CAESAR technique [Y. Wang, T. Uchida, R. Von Dreele, M.L. Rivers, N. Nishiyama, K. Funakoshi, A. Nozawa, and H. Kaneko, A new technique for angle-dispersive powder diffraction using an energy-dispersive setup and synchrotron radiation, J. Appl. Cryst. 37 (2004), p. 947] developed for large-volume presses, but extended to DAC applications with high spatial resolution. The main feature of the technique is the well-defined collimation in the beam path to the detector, which improves the signal-to-noise ratio significantly, compared to routine monochromatic angle-dispersive powder diffraction with area detectors. This is particularly useful and essential for low-scattering materials and for amorphous and liquid diffraction/scattering studies using DACs. Data collected from crystalline and amorphous samples in DACs show that a coarse 2{theta} scan (0.1--0.2{sup o} for crystals and 0.5{sup o} for amorphous structure) is sufficient to obtain reasonable diffraction resolution. The scanning angle energy-dispersive X-ray diffraction technique provides angle-dispersive X-ray diffraction (ADXD) data in multiple energies. Such multi-energy ADXD data carry much more information than regular single-energy ADXD, which could provide site-specific atomic structure information for full structure refinement.

43 PARTICLE ACCELERATORS↗