At least 847 records · Page 47

Mobility-Dependent Low-Frequency Noise in Graphene Field-Effect Transistors

We have investigated the low-frequency 1/f noise of both suspended and on-substrate graphene field-effect transistors and its dependence on gate voltage, in the temperature range between 300 and 30 K. We have found that the noise amplitude away from the Dirac point can be described by a generalized Hooge's relation in which the Hooge parameter {alpha}{sub H} is not constant but decreases monotonically with the device's mobility, with a universal dependence that is sample and temperature independent. The value of {alpha}{sub H} is also affected by the dynamics of disorder, which is not reflected in the DC transport characteristics and varies with sample and temperature. We attribute the diverse behavior of gate voltage dependence of the noise amplitude to the relative contributions from various scattering mechanisms, and to potential fluctuations near the Dirac point caused by charge carrier inhomogeneity. The higher carrier mobility of suspended graphene devices accounts for values of 1/f noise significantly lower than those observed in on-substrate graphene devices and most traditional electronic materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

Sundaram, Shivshankar↗

Programmable, four-channel, 128-sample, 40-Ms/s analog-ternary correlator

A four-channel analog-ternary CCD correlator that extends the state of the art in several important areas is discussed. Surface acoustic wave, acoustic charge transport, and CCD implementation technologies are compared, and the architecture of the CCD device is described. It is shown that, in addition to a sampling rate up to 40 Ms (megasamples) per second, a dynamic range of 66 dB, and nonlinearity below -50 dB, the device exhibits a level of integration and user-friendliness not previously available. The correlator is intended for use in communications and radar systems where pseudonoise codes are employed.

Munroe, Scott C.↗

High-Density Nanopore Array for Selective Biomolecule Transport

Development of sophisticated tools capable of manipulating molecules at their own length scale enables new methods for chemical synthesis and detection. Although nanoscale devices have been developed to perform individual tasks, little work has been done on developing a truly scalable platform: a system that combines multiple components for sequential processing, as well as simultaneously processing and identifying the millions of potential species that may be present in a biological sample. The development of a scalable micro-nanofluidic device is limited in part by the ability to combine different materials (polymers, metals, semiconductors) onto a single chip, and the challenges with locally controlling the chemical, electrical, and mechanical properties within a micro or nanochannel. We have developed a unique construct known as a molecular gate: a multilayered polymer based device that combines microscale fluid channels with nanofluidic interconnects. Molecular gates have been demonstrated to selectively transport molecules between channels based on size or charge. In order to fully utilize these structures, we need to develop methods to actively control transport and identify species inside a nanopore. While previous work has been limited to creating electrical connections off-channel or metallizing the entire nanopore wall, we now have the ability to create multiple, separate conductive connections at the interior surface of a nanopore. These interior electrodes will be used for direct sensing of biological molecules, probing the electrical potential and charge distribution at the surface, and to actively turn on and off electrically driven transport of molecules through nanopores.

36 MATERIALS SCIENCE↗

Problem-tailored Simulation of Energy Transport on Noisy Quantum Computers

The transport of conserved quantities like spin and charge is fundamental to characterizing the behavior of quantum many-body systems. Numerically simulating such dynamics is generically challenging, which motivates the consideration of quantum computing strategies. However, the relatively high gate errors and limited coherence times of today's quantum computers pose their own challenge, highlighting the need to be frugal with quantum resources. In this work we report simulations on quantum hardware of infinite-temperature energy transport in the mixed-field Ising chain, a paradigmatic many-body system that can exhibit a range of transport behaviors at intermediate times. We consider a chain with L = 12 sites and find results broadly consistent with those from ideal circuit simulators over 90 Trotter steps, containing up to 990 entangling gates. To obtain these results, we use two key problem-tailored insights. First, we identify a convenient basis – the Pauli Y basis – in which to sample the infinite-temperature trace and provide theoretical and numerical justifications for its efficiency relative to, e.g., the computational basis. Second, in addition to a variety of problem-agnostic error mitigation strategies, we employ a renormalization strategy that compensates for global nonconservation of energy due to device noise. We discuss the applicability of the proposed sampling approach beyond the mixed-field Ising chain and formulate a variational method to search for a sampling basis with small sample-to-sample fluctuations for an arbitrary Hamiltonian. This opens the door to applying these techniques in more general models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DESIGN, DEVELOPMENT AND FIELD DEPLOYMENT OF A TELEOPERATED SAMPLING SYSTEM

A teleoperated sampling system for the identification, collection and retrieval of samples following the detonation of an Improvised Nuclear Device (IND) or Radiological Dispersion Devise (RDD) has been developed and tested in numerous field exercises. The system has been developed as part of the Defense Threat Reduction Agency's (DTRA) National Technical Nuclear Forensic (NTNF) Program. The system is based on a Remotec ANDROS Mark V-A1 platform. Extensive modifications and additions have been incorporated into the platform to enable it to meet the mission requirements. The Defense Science Board Task Force on Unconventional Nuclear Warfare Defense, 2000 Summer Study Volume III report recommended the Department of Defense (DOD) improve nuclear forensics capabilities to achieve accurate and fast identification and attribution. One of the strongest elements of protection is deterrence through the threat of reprisal, but to accomplish this objective a more rapid and authoritative attribution system is needed. The NTNF program provides the capability for attribution. Early on in the NTNF program, it was recognized that there would be a desire to collect debris samples for analysis as soon as possible after a nuclear event. Based on nuclear test experience, it was recognized that mean radiation fields associated with even low yield events could be several thousand R/Hr near the detonation point for some time after the detonation. In anticipation of pressures to rapidly sample debris near the crater, considerable effort is being devoted to developing a remotely controlled vehicle that could enter the high radiation field area and collect one or more samples for subsequent analysis.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Variation in superconducting transition temperature due to tetragonal domains in two-dimensionally doped SrTiO 3

Strontium titanate is a low-temperature, non-Bardeen-Cooper-Schrieffer superconductor that superconducts to carrier concentrations lower than in any other system and exhibits avoided ferroelectricity at low temperatures. Neither the mechanism of superconductivity in strontium titanate nor the importance of the structure and dielectric properties for the superconductivity are well understood. We studied the effects of twin structure on superconductivity in a 5.5-nm-thick layer of niobium-doped SrTiO3 embedded in undoped SrTiO3. We used a scanning superconducting quantum interference device susceptometer to image the local diamagnetic response of the sample as a function of temperature. We observed regions that exhibited a superconducting transition temperature T-c greater than or similar to 10% higher than the temperature at which the sample was fully superconducting. The pattern of these regions varied spatially in a manner characteristic of structural twin domains. Some regions are too wide to originate on twin boundaries; therefore, we propose that the orientation of the tetragonal unit cell with respect to the doped plane affects T-c. Our results suggest that the anisotropic dielectric properties of SrTiO3 are important for its superconductivity and need to be considered in any theory of the mechanism of the superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects

The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd{sub 2}O{sub 2}S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of ac and dc magnetometers with a Dy{sub 2}O{sub 3} standard

The ac susceptibility and magnetization curves of a glued Dy{sub 2}O{sub 3} powder sample are measured by an ac susceptometer and a dc superconducting quantum interference device magnetometer, both of which have been calibrated previously. It is shown that the magnetic moment of the paramagnetic sample as a function of field and temperature may be accurately expressed by a combination of the Curie-Weiss law and the Langevin function at T > 45 K with three adjusting parameters, so that the dc magnetization curves and the magnitude and phase of ac susceptibility at different values of dc bias field measured by any magnetometer can be calibrated by using Dy{sub 2}O{sub 3} as a standard. The expressions are empirical and cannot be justified in the entire field and temperature range by existing theories of paramagnetism. Below 10 K, indication of approaching a possible phase transition is found. It is shown that pure Dy{sub 2}O{sub 3} powder may be used as a primary standard, with susceptibility [13.28(T+ 17)]{sup -1} emu/Oe/g at T > 50 K and H < 10 kOe, in consistency with the Curie-Weiss law and the quantum mechanical theory of paramagnetism.

36 MATERIALS SCIENCE↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗

Powder Handling Device for Analytical Instruments

Method and system for causing a powder sample in a sample holder to undergo at least one of three motions (vibration, rotation and translation) at a selected motion frequency in order to present several views of an individual grain of the sample. One or more measurements of diffraction, fluorescence, spectroscopic interaction, transmission, absorption and/or reflection can be made on the sample, using light in a selected wavelength region.

Sarrazin, Philippe C.↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Miniature cyclotron resonance ion source using small permanent magnet

An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

Anicich, V. G.↗

High-pressure high-temperature phase diagram of gadolinium studied using a boron-doped heater anvil

A boron-doped designer heater anvil is used in conjunction with powder x-ray diffraction to collect structural information on a sample of quasi-hydrostatically loaded gadolinium metal up to pressures above 8 GPa and 600 K. The heater anvil consists of a natural diamond anvil that has been surface modified with a homoepitaxially grown chemical-vapor-deposited layer of conducting boron-doped diamond, and is used as a DC heating element. Internally insulating both diamond anvils with sapphire support seats allows for heating and cooling of the high-pressure area on the order of a few tens of seconds. This device is then used to scan the phase diagram of the sample by oscillating the temperature while continuously increasing the externally applied pressure and collecting in situ time-resolved powder diffraction images. In the pressure-temperature range covered in this experiment, the gadolinium sample is observed in its hcp, αSm, and dhcp phases. Under this temperature cycling, the hcp → αSm transition proceeds in discontinuous steps at points along the expected phase boundary. From these measurements (representing only one hour of synchrotron x-ray collection time), a single-experiment equation of state and phase diagram of each phase of gadolinium is presented for the range of 0–10 GPa and 300–650 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 600-MHz median-type digital filter on GaAs

A single-chip GaAs implementation of an FIR-median hybrid filter is presented. The very high-speed digital filter combines linear averaging structures to a median selector. The filter operates on 5-b samples with ECL-compatible I/O interfaces. The 1500-transistor LSI device with 3.6-sq mm chip size was processed with a 1.0-micron GaAs depletion-mode (D-mode) MESFET process. The filter demonstrates 600-MHz sample rate when operated in test mode utilizing special built-in feedback.

Vainjo, Olli↗

The role of electron irradiation history in liquid cell transmission electron microscopy

In situ liquid cell transmission electron microscopy (LC-TEM) allows dynamic nanoscale characterization of systems in a hydrated state. Although powerful, this technique remains impaired by issues of repeatability that limit experimental fidelity and hinder the identification and control of some variables underlying observed dynamics. We detail new LC-TEM devices that improve experimental reproducibility by expanding available imaging area and providing a platform for investigating electron flux history on the sample. Irradiation history is an important factor influencing LC-TEM results that has, to this point, been largely qualitatively and not quantitatively described. We use these devices to highlight the role of cumulative electron flux history on samples from both nanoparticle growth and biological imaging experiments and demonstrate capture of time zero, low-dose images on beam-sensitive samples. In particular, the ability to capture pristine images of biological samples, where the acquired image is the first time that the cell experiences significant electron flux, allowed us to determine that nanoparticle movement compared to the cell membrane was a function of cell damage and therefore an artifact rather than visualizing cell dynamics in action. Lastly, these results highlight just a subset of the new science that is accessible with LC-TEM through the new multiwindow devices with patterned focusing aides.

59 BASIC BIOLOGICAL SCIENCES↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract