Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Low-Cost Electrochemical Compressor (ECC) Utilizing Green Refrigerants for HVAC Applications [Slides]

HVAC systems account for approximately 14 Quads or primary energy annually, or nearly 30% of all energy used in the U.S. commercial and residential buildings. Electrochemical compression (ECC) is a transformative solid-state technology and ECC based HVAC systems could result in 40% less energy use. The goal of the project was to develop the most efficient, noiseless, and most environmentally friendly cooling system based on integrating 2 (two) technologies: a) electrochemical compressors (ECC) to replace mechanical compressors for use in building heating, ventilation, and air conditioning (HVAC) applications and b) Ionic Liquid Desiccant Systems. The overall objective was to develop and build a scalable ILD/ECC-based air conditioning system operating with a COP of 4.5, with a price premium of $70 installed per kBTU/hr.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A section 110 evaluation of the 10,500-foot blast line civil effects structures and military trenches associated with the apple-2 test, area 1, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has tasked Desert Research Institute (DRI) with identifying and evaluating additional resources that contribute to the significance of the Apple-2 Historic District as part of a Section 110 effort. Apple-2 was a 1955 atmospheric test in which the Federal Civil Defense Administration (FCDA) conducted an extensive civil effects program named Operation Cue. The objective of Operation Cue was to understand the blast and thermal effects of the test by using a simulated community of residential buildings, industrial structures, utilities, and commercial equipment arranged at various distances from ground zero (GZ). Military operations conducted by the Department of Defense (DoD) as part of the Desert Rock VI exercise were also associated with the Apple-2 test. The Apple-2 Historic District was originally defined in 2000 by Johnson and Edwards as 15 highly visible contributing elements dispersed across the landscape. Since its original recording, DRI has conducted additional archival research and this report details the identification and evaluation results of testing-related material remains at a distance of 10,500 ft from the Apple-2 GZ. Between 2017 and 2020, DRI conducted fieldwork at 10,500 ft from the Apple-2 GZ, revisited previously recorded contributing elements, and identified and evaluated newly recorded resources associated with Operation Cue as well as DoD operations. In total, DRI revisited or newly identified 15 principal resources. Of these, 13 are located within the historic district and contribute to the district’s significance. A set of military trenches and the associated material remains are discontiguous from the district, but also contribute to the district’s significance.

54 ENVIRONMENTAL SCIENCES↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing the Split Incentive Challenge for Enhanced Solar Adoption in Multifamily Rental Properties [Abstract]

The split incentive problem is particularly pronounced in rental markets, where landlords prioritize investments that directly increase property value or rental income. Since energy savings from solar photovoltaic (PV) systems primarily benefit tenants, landlords may perceive little return on investment unless mechanisms exist to recapture some of the financial gains. The primary objective of this project is to develop a publicly available, web-based tool to analyze the U.S. Department of Energy’s ResStock database, which models the U.S. residential building stock. The tool allows users to filter buildings by location, type, HVAC system, square footage, and other characteristics, and outputs typical electric load profiles. By leveraging location-specific electric load data, Fram Energy aims to advance business strategies that address the split incentive barrier and promote the adoption of solar PV installations in rental properties. In addition, a machine learning model will be developed to weigh the marginal contribution of building features across the dataset in predicting electricity demand, supporting guided decision making in forecasting electric load profiles. Lastly, based on each building’s location, load profile, and utility’s electricity rate, an optimized solar photovoltaic array and battery energy storage system will be sized to provide energy arbitrage opportunities.

14 SOLAR ENERGY↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IES Standard 90.1-2022 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2022 (Standard 90.1-2022). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 was a new feature of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The procedures and processes described in the PRM reference manual (PRM-RM) are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot Water Recirculation Systems: Designing for Success [Slides]

This presentation will focus on on-demand hot water recirculation systems and how they contribute to energy and water conservation in residential buildings. This work illustrates best practices for designing, installing, and operating these systems, drawing from research and field testing to provide practical recommendations. The ultimate goal is to reduce wait times for hot water, comply with current energy codes, and lower both energy use and greenhouse gas emissions, while improving user satisfaction. In the upcoming slides, we'll dive into case studies and explore the latest technological advancements that help achieve these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IES Standard 90.1-2019 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2019 (Standard 90.1-2019). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 was a new feature of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The procedures and processes described in the PRM reference manual (PRM-RM) are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Design, evaluation and recommedation effort relating to the modification of a residential 3-ton absorption cycle cooling unit for operation with solar energy

The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.

Merrick, R. H.↗

Installation of surface-mounted flat-conductor cable

Guide describes step-by-step process for installation of interior surface-mounted FCC used in commerical and residential buildings. Photographs illustrate how cable-riser and baseboard covers are installed as well as receptacle assembly and receptacle-cover replacement.

Carden, J. R.↗

Development of a solar-powered residential air conditioner

The initial objective of the program was the optimization (in terms of cost and performance) of a Rankine cycle mechanical refrigeration system which utilizes thermal energy from a flat solar collector for air conditioning residential buildings. However, feasibility investigations of the adsorption process revealed that a dessicant-type air conditioner offers many significant advantages. As a result, limited efforts were expended toward the optimization of such a system.

Source record↗

Public policy for solar heating and cooling

Recent analyses indicated that solar heating and cooling systems for residential buildings are nearly economically competitive with conventional fossil fuel or electric systems, the former having higher initial cost but a lower operating cost than the latter. The paper examines obstacles to the widespread acceptance and use of solar space conditioning systems and explores some general policies which could help to overcome them. The discussion covers such institutional barriers limiting the adoption of solar technologies as existing building codes, financing constraints, and organizational structure of the building industry. The potential impact of financial incentives is analyzed. It is noted that a tax incentive of 25% could speed the use of solar energy by 7 to 8 years and produce an 8% reduction in fossil fuel use by 1990. A preliminary incentive package which could be helpful in promoting solar energy both at federal and state levels is proposed, and the necessary incentive level is analysed.

Hirshberg, A. S.↗

Solar energy storage and utilization

A method of storing solar energy in the ground for heating residential buildings is described. The method would utilize heat exchanger pipes with a circulating fluid to transfer the energy beneath the surface as well as to extract the stored energy.

Yuan, S. W.↗