Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Muon Tracking to Detect Special Nuclear Materials

Previous experiments have proven that high-Z materials can be located in shielded configurations and that nuclear assemblies can be imaged and identified inside of shipping containers using vertical trajectory cosmic-ray muons with two-sided imaging. These experiments have further demonstrated that nuclear assemblies can be identified by detecting fission products in coincidence with tracked muons. By developing these technologies, advanced sensors can be designed for a variety of warhead monitoring and detection applications. The focus of this project is to develop tomographic-mode imaging using near-horizontal trajectory muons for weapons and spent fuel applications. This will allow passive imaging in-situ without the need to relocate the objects.

cosmic ray muons, muon tracking, SNM, spent fuel↗

Paddys Run Streambank Stabilization Project at the Fernald Preserve, Harrison, OH

The Fernald Preserve is a former uranium-processing plant that underwent extensive remediation pursuant to CERCLA and is now managed by the US DOE Office of Legacy Management. While remediation of buildings and soil contamination was completed in 2006, aquifer remediation is ongoing. Paddys Run is a second-order stream that runs to the south along the western side of the Fernald Preserve. The Paddys Run watershed encompasses nearly 41 km2 (16 mi2), including most of the Fernald site. Field personnel conducting routine site inspections in March 2014 observed that Paddys Run was migrating east via bank erosion into the “Pit 3 Swale,” an area of known surface-water contamination. The soil there was certified pursuant to site regulatory agreements and meets all final remediation levels. However, weekly surface-water monitoring is conducted from two puddles within the swale area, when water that exceeds the final remediation levels is present. Paddys Run had migrated east approximately 4 m (13 ft) in 2 years and was approximately 29 m (95 ft) from the sample location. This rapid migration threatened existing conditions that allowed for continued monitoring of the swale area and also threatened Paddys Run water quality. Therefore, DOE and regulators determined that the east bank of Paddys Run required stabilization. This was accomplished with a design that included the following components: relocation of approximately 145 m (475 ft) of streambed 9 m (30 ft) west, installation of a rock toe along the east bank, installation of two cross-vane in-stream grade-control structures, stabilization of a portion of the east bank using soil encapsulated lifts, and regrading, seeding, and planting within remaining disturbed areas. In an effort to take advantage of low-flow conditions in Paddys Run, construction was initiated in September 2014. Weather delays and subsurface flow within the Paddys Run streambed resulted in an interim shutdown of the project area in December 2014. Construction activities resumed in April 2015, with completion in November 2015. To date, this stabilization project has been successful. The regraded bank and streambed have remained stable, and no compromise to installed cross-vanes, the rock toe, or the soil encapsulated lifts has been observed.

54 ENVIRONMENTAL SCIENCES↗

PNNL’s Building Operations Control Center

PNNL's Building Operations Control Center (BOCC) video provides an overview of the center, its capabilities, and its objectives. The BOCC was relocated to PNNL's new 3820 Systems Engineering Building in 2015. Although a key focus of the BOCC is on monitoring and improving the operations of PNNL buildings, the center's state-of-the-art computational, software and visualization resources also have provided a platform for PNNL buildings-related research projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

Analysis of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

RF Energy Harvesting Peel-and-Stick Sensors

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. The sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths when the RF beam is swept allows for sensor localization, further reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with a duty cycle less than a minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna dimensions was less than 5cmx9cm, demonstrating the possibility of small form factor for the sensor nodes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PEEL-AND-STICK SENSORS POWERED BY DIRECTED RF ENERGY

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification of Y-12 Legacy Criticality Accident Alarm System Detectors

The Y-12 National Security Complex has had a criticality accident alarm system (CAAS) capable to detect a criticality accident since 1945. With the exception of Y-12’s new High-enriched Uranium Materials Storage facility (HEUMF), the system installed in Y-12’s existing facilities dates to 1957. This legacy system has received many upgrades since installation and detector stations have been removed and relocated as enriched uranium operations have evolved, but the basic design and electronic configuration of the system is the same as that in 1957.

61 RADIATION PROTECTION AND DOSIMETRY↗

Materials for Advanced Ultra-Supercritical (AUSC) Steam Turbines – AUSC Component Demonstration

The work by the United States Department of Energy (U.S. DOE)/Ohio Coal Development Office (OCDO) Advanced Ultra-Supercritical (AUSC) Steam Boiler and Turbine Materials Consortia from 2001 through September 2015 was primarily focused on lab scale and pilot scale materials testing. The field testing included air-cooled probes and steam-cooled “loops” that were installed into existing utility boilers to gain exposure of these materials to realistic conditions of high temperature and corrosion due to the constituents in the coal ash. Successful research and development resulted in identification of metallic alloy materials and fabrication processes suited for power generation applications with metal temperatures up to approximately 1472°F (800°C). These materials or alloys have shown, in extensive laboratory tests and shop fabrication studies, to have excellent applicability for high-efficiency low CO2 transformational power generation technologies. However, as valuable as these material field tests have been for obtaining information, their scale is significantly below that required to minimize the risk associated with a power company building a multi-billion-dollar AUSC power plant. To decrease the identified risk barriers to full-scale implementation of these advanced materials, the U.S. DOE/OCDO AUSC Steam Boiler and Turbine Materials Consortia identified the key areas of the technology that need to be tested at a larger scale. Based upon the recommendations and outcome of a Consortia-sponsored workshop with the U.S.’s leading utilities, a Component Test (ComTest) Program for AUSC was proposed. The AUSC ComTest program would define materials performance requirements, plan for overall advanced system integration, design critical component tests, fabricate components for testing from advanced materials, and carry out the tests. A Pre-FEED evaluation of the test facility including the evaluation of three potential sites has been completed and previously reported. This report describes the Front-End Engineering Design (FEED), Detailed Engineering and the Environmental Assessment of the ComTest project. A significant amount of work was accomplished during Phase 1 to identity the components, as well as the component size, that would be manufactured from advanced alloys such as INCONEL 740H or HAYNES 282 alloys. Pathways to supply these components for ComTest have been identified as well as any further development that would be required. Every project of this nature has challenges and this project was no exception. The greatest challenge has been the project cost. Largely due to the infrastructure and balance of plant equipment upgrades required for Youngstown Thermal, the estimated project cost for the “base case” project was greater than originally budgeted. The project team spent a significant amount of time exploring opportunities for reducing the project cost. These options included: • Youngstown Thermal was exploring building a Combined Heat and Power (CHP) unit at their facility. The Youngstown Thermal staff, supported by Thermal Engineering Group, worked with the project team to determine whether it was economically desirable to supply ComTest with steam and other utilities, which would be supplied by the CHP project. • The project team also evaluated opportunities to optimize the project scope to reduce cost, such as reducing project scope by eliminating the Superheater Outlet Header test. • Southern Company had offered two sites as possible host locations for ComTest. Both sites had infrastructure in place such as steam from an existing unit, natural gas, cooling water and ample electrical power that would be required to be added at the Youngstown Thermal site. Utilizing this existing infrastructure could reduce the project cost. An additional project challenge was the departure of Babcock and Wilcox from the project in September 2016. This project setback was overcome by GE Power’s willingness to assume the design of the ComTest superheater. Since the project could not proceed without the superheater, this was a very positive project development. The merger of the GE Power and Alstom Power steam turbine divisions created synergies leading to the conclusion that instead of building a small-scale turbine, a more practical and useful endeavor would be to validate the manufacturing technology and supplier readiness for fabricating and machining full scale steam turbine components. Consequently, in March 2017, GE Power decided that a steam turbine test would not be necessary as part of the ComTest demonstration. Removing the operational testing of the steam turbine from ComTest further reduced the total project cost. Additionally, there was an opportunity to move ComTest from Youngstown Thermal to one of the Southern Company sites and operate ComTest at supercritical steam conditions and test the steam turbine main stop/control valve at a temperature and pressure that would be representative of the conditions of a high pressure steam turbine inlet valve. The steam could also possibly be returned to the host boiler so there would be no economic penalty of using this steam for ComTest. Relocating the project could further reduce the project cost due to the infrastructure already in place, including high pressure natural gas and cooling water, and the potential for heat integration, allowing a reduction of operating costs. Due to these potential cost reductions, it was decided to move the project away from Youngstown Thermal in March 2017. As integrating ComTest at the Southern Company site was explored, an issue was raised regarding the integration of the ComTest cycle with the plant steam cycle. Steam would be supplied to ComTest at nominally ~3865 psia and 775°F. The steam would be heated with natural gas to 1400°F for the valve test and then cooled to 1000°F so that the steam would be returned to the host boiler at the same conditions as their high pressure steam turbine inlet. However, there were concerns raised that the addition of the energy (natural gas) to the steam could trigger a New Source Review on the unit. Southern Company did not want ComTest to cause this review, so condensing all of the steam exiting ComTest and returning it to the host steam cycle as condensate was explored to insure there would be no implication that ComTest was adding energy to the host plant’s steam cycle. Ultimately, Southern Company decided that they wanted to “decouple” ComTest from the operating unit, making ComTest self-supporting, similar to the Youngstown Thermal “base case.” Without the steam turbine, the project team reached a consensus that operating the ComTest Superheater and steam turbine valves at the typical pressure of a package boiler (~1000 psig) would not generate enough useful technical information to justify the cost of the test. Therefore, it was decided in the December 2017 project quarterly meeting to cancel the operational phase of ComTest. Throughout the engineering phase of ComTest, manufacturing and supply chain challenges were identified. When GE Power recommended dropping the steam turbine test from ComTest, they identified many important manufacturing issues that should be evaluated and demonstrated. Other challenges had been raised by the GE Power group designing the superheater as well as those engineering components such as pressure relief and steam turbine bypass valves. In the December 2017 meeting, the project team decided that it was more beneficial to the AUSC technology to pursue these manufacturing and supply chain issues as Phase 2 of the ComTest project. This report is organized in the following manner: • Section 2 discusses the ComTest project background and organization. • Section 3 discussed project management. • Section 4 discusses the design of the ComTest AUSC components – the Superheater, steam turbine and Superheater Outlet Header. • Section 5 discusses the implementation of ComTest at Youngstown Thermal and the Southern Company site. • Section 6 discusses the development of the AUSC Supply Chain • Section 7 discusses the recommended plan for Phase 2 of ComTest

01 COAL, LIGNITE, AND PEAT↗

New Release of Fuel Performance Code, FRAPCON-3.5 and FRAPTRAN-1.5

New versions of the USNRC fuel performance codes, FRAPCON-3 and FRAPTRAN are available to members of the code users group. FRAPCON-3.5 and FRAPTRAN-1.5 include model improvements to various material property models such as gaseous swelling, primary creep, pellet relocation, cladding models, cladding ballooning, and ID oxidation. Various new capabilities have been added such as increased numbers of time steps, axial nodes, and radial nodes. The ability to model pellet chamfers has been added. The ability to specify variable axial node lengths and specify different enrichment, gadolinia content, and central hole size in each axial node has been added. Finally the capability to model refabrication of a rodlet following irradiation of a full length rod has been added to FRAPCON-3.5. This paper will describe the changes made in the new versions of FRAPCON-3 and FRAPTRAN.

FRAPCON, FRAPTRAN↗

Ion concentration polarization-electrocoagulation hybrid water treatment system

Between two juxtaposed similar ion exchange membranes (AEMs or CEMs), an ion depletion zone and ion enrichment zone are generated under an electric field. As cations are selectively transferred through the CEMs, for example, anions are relocated in order to achieve electro-neutrality, resulting in the concentration drop (increase) in ion depletion (enrichment) zone. The use of a sacrificial metal anode allows electrocoagulation (EC) concurrently with ICP thereby permitting concentration of both ionic and non-ionic impurities to occur at the same time within the same cell or device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AUXILIARY FEEDWATER REHEATING TO MITIGATE PRIMARY AND SECONDARY SIDE THERMAL STRESSORS

A consequence of operating steam cycles under time varying loads, is the variability of the feedwater temperature entering the bottom of the steam generators. This variability is a direct result of changes in turbine impulse pressure and subsequently turbine tap pressures in response to the load changes, with a reduction in feed temperature during periods of low turbine demand. These fluctuations over time will increase thermal cycling and threaten the integrity of the tube bundle as well as other components in the feed system. Sensible heat, TES systems have been shown to be an effective load management strategy allowing nuclear reactor systems to operate at effectively 100% full power while storing excess thermal energy for recovery later. A byproduct of the TES system is the availability of large amounts of low grade waste heat that can be used for ancillary applications, including auxiliary feed heating during periods of low turbine demand. The addition of an auxiliary feed heater at the end of the traditional feed train can minimize feed temperature variations during periods of low turbine demand, reducing the effects of thermal cycling and increasing overall thermodynamic efficiency. This paper discusses the design, operation and control strategies for an auxiliary feed water system as an integral component of a coupled Thermal Energy Storage system and Integral Pressurized Water Reactor. The impact on system performance, particularly as it affects reactor dynamic response and reductions in thermal cycling will be addressed. In addition to the improved thermal efficiency, a benefit of this approach is the relocation of thermal stressors from the reactor coolant system to more easily managed Balance of Plant systems

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Re-Evaluating the Current Safety Goals

The Safety Goals adopted by the US NRC consist of two qualitative safety goals (QSGs) backed up by two quantitative health objectives (QHOs). The QHOs establish risk limits for severe accidents in terms of their radiological consequences, in particular, the average individual health risks of early fatality and latent cancers from radiation exposure of members of the public living in the vicinity of a nuclear power plant. This paper is devoted to a re-examination of the coverage of the current safety goals in evaluating the actual risk posed by nuclear power plant operation. Experience of recent Level 3 PRAs suggests that given a high likelihood of evacuation of the close-in population before any release occurs, the current QHOs are satisfied by large margins. However, the experience of an actual severe accident at Fukushima showed that actual human health effects from released radiation were not the dominant consequences; there were no early fatalities and no measurable increases expected in cancer rates above the baseline rates in the Japanese population. Hence, regardless of accident probability, Fukushima-type accidents would satisfy the NRC’s health-related safety goals. However, there were very significant societal costs, in that large numbers of people were relocated for long periods. We argue that, in addition to the risks addressed in current safety goals, societal risk should also be evaluated. The paper discusses specific possibilities for a goal and an associated quantitative objective.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Purification of ultra-high saline and contaminated water by multi-stage ion concentration polarization (ICP) desalination

A water stream is passed between two juxtaposed similar ion exchange membranes (AEMs or CEMs), forming an ion depletion and ion enrichment zones when an electric field is applied. As cations are selectively transferred through the CEMs, for example, anions are relocated in order to achieve electro-neutrality, resulting in the concentration drop (increase) in ion depletion (enrichment) zone. Trifurcation of the output channel allows collection of concentrated, dilute and intermediate streams, with the intermediate stream serving as input to the next stage of a serialized implementation.

Kim, Bumjoo↗

Separate-Effects Validation Experiments for Models of Fracture in Ceramic Nuclear Fuel

A number of advances have recently been made in modeling fracture initiation and propagation in ceramic light water reactor (LWR) fuel. These include the use of techniques such as peridynamics, the extended finite element method (XFEM), the discrete element method (DEM), and phase field fracture. Improved predictions of fracture in LWR fuel can benefit fuel performance simulations in a number of ways, with important implications for radial relocation, pellet-cladding mechanical interactions, and fragmentation during accident conditions. Although these modeling approaches appear promising, to-date most of their applications have been to fresh fuel. A major limitation in applying these approaches with confidence to a wider variety of conditions, such as fragmentation of high-burnup fuel, is that there is very limited data that can be directly used to validate the results of these fracture models. While fracture patterns are available from cross-sections of numerous irradiated fuel rods, the fuel rods have typically been subjected to complex irradiation histories. To validate models of fracture propagation, focused experiments that give snapshots of the initiation and propagation of fracture under well characterized prototypical reactor conditions are needed. Under a multi-institutional U.S. Department of Energy Integrated Research Project (IRP), three separate-effects validation experiments are underway to provide information on the propagation of cracks in LWR fuel under controlled conditions. The primary challenge in developing such an experiment is in providing conditions that result in a radial temperature distribution that is prototypical of LWR in-reactor conditions. Two out-of-reactor experiments are being planned that employ very different approaches to achieve such a temperature distribution. The first of these achieves this by employing a combination of inductive and resistive electrical heating to generate volumetric heating. The second experiment involves slowly heating a pellet in a metal rod to a high temperature, and then quenching that rod in a cold bath. The quenching process generates a temperature profile approximating that in an LWR fuel rod for a moment, but has a very different temperature history from the LWR. Finally, an experiment is being planned for the Idaho National Laboratory TREAT reactor that will use nuclear fission as a heat source, and which will employ a metal heat sink to replicate the thermal conditions provided by coolant in an LWR. These experiments all have their advantages and drawbacks, with varying levels of ability to reproduce actual LWR conditions and varying ability to use instruments to monitor quantities of interest over the course of the experiment that can be used to validate fracture models. For that reason, these different experimental approaches are complimentary to each other, and the combined results are expected to significantly improve confidence in the ability of computational models to simulate fracture in ceramic nuclear fuel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Separate Effects Testing in TREAT for ATF Fuels

This work performed examinations on high burnup UO2 from commercial power plant with the intention of better understanding fission gas and fragmentation behavior. Fuel fragmentation, relocation, and dispersal (FFRD) is a major factor in fuel lifetime limits imposed on UO2 by regulators, both domestic and foreign, and is a major area of interest by industry groups (e.g., Electric Power Research Institute, [EPRI]). The characterization of the fuel focused on the differences in porosity between the high burnup (rim) zone, the dark (intermediate) zone, and center zones of the fuel as well as the fission gas content of each region. Work involved thermal treatments to analyze fission gas and high resolution microscopy techniques to investigate pore structure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Optimization-Based Strategy for SAV Fleet Repositioning

With the emergence of autonomous technology, shared autonomous vehicles (SAVs) will potentially be the prevalent transportation mode for urban mobility. On one hand, relying on SAV fleets can provide several operational benefits. On the other hand, SAVs can increase travel distance and add congestion due to unoccupied trips such as pickup and repositioning trips. One important aspect for a SAV fleet's success is to serve the incoming requests at reasonably low waiting time. This is achieved by an adequate fleet size that is spatially distributed thoughtfully so that incoming requests can be served by a nearby vehicle. Unfortunately, it is challenging to keep a satisfactory spatial distribution of vehicles due to imbalances in the origin and destination patterns of incoming requests. This paper focuses on the impact of SAV relocation on traveler wait times using a novel optimization-based algorithm for repositioning. POLARIS, an agent-based tool, is used for a case study of Bloomington, Illinois to quantify the benefits of allowing SAV repositioning. On average, the wait times were around 20% lower with repositioning for all adequate fleet sizes. SAVs were available more uniformly across the region's zones, and proportional to trip-making at different times of day. In addition, enabling repositioning led to a higher share of demands being served. These benefits, however, are achieved at the expense of 6% added vehicles miles traveled.

Agent-Based Simulation↗

Experiment Assembly and Testing in Hot Cell in Support of Advanced Fuels Irradiation Testing

Follow-on experimentation of irradiated nuclear fuel is critical to understanding fuel behavior at different stages of the fuel lifecycle. Transient experiments using fuel with high burnup can enlarge understanding of fuel fragmentation, relocation and dispersal under various reactor accident situations. Assembling experiments with such fuel requires remote operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗