Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

Structural conditionality for the quadratic nonlinear susceptibility of Sr{sub 1-x}Ba{sub x}Nb{sub 2}O{sub 6} crystals

The intensity of the second harmonic generated in powdered samples of the compositions Sr{sub 0.75}Ba{sub 0.25}Nb{sub 2}O{sub 6}, Sr{sub 0.61}Ba{sub 0.39}Nb{sub 2}O{sub 6}, and Sr{sub 0.50}Ba{sub 0.50}Nb{sub 2}O{sub 6} under irradiation by a pulsed-periodic YAG: Nd laser is measured. The effective values of the quadratic nonlinear susceptibility of these materials with respect to the reference sample of potassium dihydrophosphate crystals are estimated. The results obtained are compared with the precise parameters of the atomic structure of the single crystals with the corresponding compositions. It is established that the dominant contribution to the nonlinear optical susceptibility of the single crystals under investigation comes from the chains aligned parallel to the c axis of the crystal and composed of Nb octahedra with regularly alternating increased and decreased Nb-O interatomic distances. The occurrence of such a sequence in the crystal structure suggests an alternation of stronger and weaker chemical bonds in the chains -O=Nb-O=Nb-O=. These bonds are characterized by different charge electron densities, a phenomenon confirmed by the X-ray diffraction analysis, which indicates not only a difference in the Nb-O bond lengths but also an anharmonicity in the thermal vibrations of the niobium atoms. The revealed anharmonicity is associated with the difference between the chemical bonds of the niobium atoms with the oxygen atoms located in trans positions in the octahedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fuel Cycle Services Needs Estimator v.2.0

The "Fuel Cycle Services Needs Estimator", Version 2.0 allows users to estimate the amount of uranium enrichment services needed and amount of spent nuclear fuel produced by a given fleet of nuclear power reactors through 2050 based on user-determined information about the size of a reactor fleet and average characteristics of reactors in that fleet. The program helps users evaluate the current and future supply of nuclear fuel cycle services. The program also allows users to compare the enrichment needs and spent fuel production of more up to seven defined nuclear power reactor fleets and to aggregate estimated needs. Version 2.0 of the program has an additions of new graphs to show results of calculations (calculation capabilities and other graphing tools included in version 1.o), maps showing flows of material based on calculation results, and additional calculation capabilities that allow the user to compare supply to demand (demand calculations included in version 1.0). Default values for seven selected nuclear energy programs in East Asia are included for reference and comparison. The program was designed using the dynamic simulation software, Powersim.

Saltiel, DavidH.↗

Analysis of the dependence of critical electric field on semiconductor bandgap

Abstract Understanding of semiconductor breakdown under high electric fields is an important aspect of materials’ properties, particularly for the design of power devices. For decades, a power-law has been used to describe the dependence of material-specific critical electrical field ( $${\mathcal{E}}_{\text{crit}}$$ E crit ) at which the material breaks down and bandgap ( E g ) . The relationship is often used to gauge tradeoffs of emerging materials whose properties haven’t yet been determined. Unfortunately, the reported dependencies of $${\mathcal{E}}_{\text{crit}}$$ E crit on E g cover a surprisingly wide range in the literature. Moreover, $${\mathcal{E}}_{\text{crit}}$$ E crit is a function of material doping. Further, discrepancies arise in $${\mathcal{E}}_{\text{crit}}$$ E crit values owing to differences between punch-through and non-punch-through device structures. We report a new normalization procedure that enables comparison of critical electric field values across materials, doping, and different device types. An extensive examination of numerous references reveals that the dependence $${\mathcal{E}}_{\text{crit}}$$ E crit ∝ E g 1.83 best fits the most reliable and newest data for both direct and indirect semiconductors. Graphical abstract

36 MATERIALS SCIENCE↗

Ionization potential and electron affinity for six common explosive compounds by DFT, MP2, and CBS-QB3

The vertical and adiabatic ionization potential (IP V and IP A ) and vertical electron affinity (EA V ) for six explosives (RDX, HMX, TNT, PETN, HMTD, and TATP) have been studied by ab initio computational methods. The IPV was calculated using MP2 and CBS-QB3 while the IP A was calculated with B3LYP, CAM-B3LYP, ω B97XD, B2PLYP, and MP2. RDX and TNT IP A ’s were also reported using CBS -QB3. Excluding results by CBS-QB3, B3LYP and B2PLYPD provided superior and more consistent results for calculating the IP. The EA V were calculated using the same methods however B3LYP performed the worst in this case with MP2 and B2PLYPD predicting values closest to those made by CBS-QB3, which was used a reference due to lacking experimental data. Basis set effects were evaluated using 6- 31+G(d,p), 6-311+G(d,p), and 6-311+(3df,2p) for both IP and EA. 6-31+G(d,p) gave satisfactory results for calculating both IP however 6-311+G(3df,2p) had improved results in calculating the EA. The four nitro containing compounds had exothermic reduction potentials while the peroxides were unfavorable. Additionally, it was seen that RDX, HMX, TATP and HMTD were unstable in their reduced forms. Results are aimed to assist detection and screening methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers

Solid-state lasers have been demonstrated as attractive drivers for inertial confinement fusion on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) and at the Omega Facility at the Laboratory for Laser Energetics (LLE) in Rochester, NY. For power plant applications, these lasers must be pumped by semiconductor diode lasers to achieve the required laser system efficiency, repetition rate, and lifetime. Inertial fusion energy (IFE) power plants will require approximately 40-to-80 GW of peak pump power, and must operate efficiently and with high system availability for decades. These considerations lead to requirements on the efficiency, price, and production capacity of the semiconductor pump sources. This document provides a brief summary of these requirements, and how they can be met by a natural evolution of the current semiconductor laser industry. The detailed technical requirements described in this document flow down from a laser ampl9ifier design described elsewhere. In brief, laser amplifiers comprising multiple Nd:glass gain slabs are face-pumped by two planar diode arrays, each delivering 30 to 40 MW of peak power at 872 nm during a {approx} 200 {micro}s quasi-CW (QCW) pulse with a repetition rate in the range of 10 to 20 Hz. The baseline design of the diode array employs a 2D mosaic of submodules to facilitate manufacturing. As a baseline, they envision that each submodule is an array of vertically stacked, 1 cm wide, edge-emitting diode bars, an industry standard form factor. These stacks are mounted on a common backplane providing cooling and current drive. Stacks are conductively cooled to the backplane, to minimize both diode package cost and the number of fluid interconnects for improved reliability. While the baseline assessment in this document is based on edge-emitting devices, the amplifier design does not preclude future use of surface emitting diodes, which may offer appreciable future cost reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.

42 ENGINEERING↗

Advanced Fuel Cycle Cost Basis Report: Module D1-4 and Module D1-5 Ceramic Pelletized Sodium-Cooled Fast Reactor (SFR) Fuel Fabrication Ceramic Vibrocompacted Fuel Fabrication

This is a cost module that is part of the Advanced Fuel Cycle -- Cost Basis Report. Module D1-4: Nature of this module update (Rev 1) from previous advanced fuel cycle cost basis reports (AFCCBRs): new life cycle cost data on U,Pu SFR mixed oxide (MOX) fuels is derived from the Nonproliferation Assessment Systems Analysis Program (NASAP) conducted in the late 1970s. Highassay low-enriched uranium (HALEU) ceramic fuel is also discussed in more detail compared to earlier AFC-CBRs, since some advanced SFR concepts currently under development will require this HALEU fuel type for startup. Module D1-5: Nature of this FY-21 module update from previous AFC-CBRs: this module includes a few new references and a somewhat expanded discussion of vibrocompaction fuel fabrication technology. The WIT values for VIPAC are pegged directly to those for conventional LWR and SFR pelletized U,Pu MOX (note that this module now includes VIPAC MOX fuel for LWRs in addition to SFRs). Based on information from Russia, where VIPAC has been studied extensively, the unit costs are expressed as a percentage of those in the new updated Module D1-2 (pelletized U,Pu MOX) and new updated Module D1-4 (pelletized U,Pu MOX) for large NOAK fabrication facilities of the same production capacity. Since both ceramic pelletized MOX Modules D1-2 and D1-4 benefitted from analysis of 1970s NASAP data, by extension this Module D1-5 also benefits.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heavy-Ion-Induced Lung Tumors: Dose- & LET-Dependence

There is a limited published literature reporting dose-dependent data for in vivo tumorigenesis prevalence in different organs of various rodent models after exposure to low, single doses of charged particle beams. The goal of this study is to reduce uncertainties in estimating particle-radiation-induced risk of lung tumorigenesis for manned travel into deep space by improving our understanding of the high-LET-dependent dose-response from exposure to individual ion beams after low particle doses (0.03 - 0.80 Gy). Female CB6F1 mice were irradiated with low single doses of either oxygen, silicon, titanium, or iron ions at various energies to cover a range of dose-averaged LET values from 0.2 - 193 keV/µm, using 137Cs γ-rays as the reference radiation. Sham-treated controls were included in each individual experiment totally 398 animals across the 5 studies reported. Based on power calculations, between 40 - 156 mice were included in each of the treatment groups. Tumor prevalence at 16 months after radiation exposure was determined and compared to the age-matched, sham-treated animals. Results indicate that lung tumor prevalence is non-linear as a function of dose with suggestions of threshold doses depending on the LET of the beams. Histopathological evaluations of the tumors showed that the majority of tumors were benign bronchioloalveolar adenomas with occasional carcinomas or lymphosarcomas which may have resulted from metastases from other sites.

60 APPLIED LIFE SCIENCES↗

Reliable algorithms for power system analysis in the presence of data uncertainties

A robust and reliable power flow analysis represents an essential requirement for many power systems applications as far as network optimization, voltage control, state estimation, and service restoration are concerned. The most common power flow approach, referred to here as a deterministic power flow (PLF), requires precise or 'crisp' values chosen by the analyst for each input variable. The solution provides precise network voltages and flows through each line. The specified values rest upon assumptions about the operating condition derived from historical measurements or predictions about future conditions and thus, cannot be considered accurate. Even in the case where the inputs are based on measurements, inaccuracies arise from time-skew problems, three-phase unbalance, static modeling approximations of dynamic components (e.g., transformer tap changers), variations in line parameters, and so on. The advent of deregulation and competitive power markets will only exacerbate this problem as well-known generation patterns change, loading becomes less predictable and the transmission paths grow more diverse. Conventional methodologies proposed in literature address tolerance analysis of power flow solution by means of detailed probabilistic methods, accounting for the variability and stochastic nature of the input data, and sampling based approaches. In particular uncertainty propagation using sampling based methods, such as the Monte Carlo, requires several model runs that sample various combinations of input values. Since the number of model runs can sometimes be very large, the required computer resources can sometimes be prohibitively expensive resulting in substantial computational demands. As far as probabilistic methods are concerned, they represent a useful tool, especially for planning studies, but, as evidenced by the many discussions reported in literature, they could reveal some shortcomings principally arising from: (1) the non-normal distribution and the statistical dependence of the input data; and (2) the difficulty arising in accurately identifying probability distributions for some input data, such as the power generated by wind or photovoltaic generators. All these could result in time consuming computations with several limitations in practical applications especially in power flow analysis of complex power networks. In order to try and overcome some of these limitations, obtaining thereby comprehensive power flow solution tolerance analysis at adequate computational costs, self validated computation could play a crucial role. Armed with such a vision, this chapter will analyze two advanced techniques for power flow analysis in the presence of data uncertainty namely the boundary power flow and the affine arithmetic power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Free-Standing Bialkali Photocathodes Using Atomically Thin Substrates

This study reports successful deposition of high quantum efficiency (QE) bialkali antimonide K2CsSb photocathodes on graphene films. The results pave the way for an ultimate goal of encapsulating technologically relevant photocathodes for accelerator technology with an atomically thin protecting layer to enhance lifetime while minimizing QE losses. A QE of 17% at approximate to 3.1 eV (405 nm) is the highest value reported so far on graphene substrates and is comparable to that obtained on stainless steel and nickel reference substrates. The spectral responses of the photocathodes on graphene exhibit signature features of K2CsSb including the characteristic absorption at approximate to 2.5 eV. Materials characterization based on X-ray fluorescence and X-ray diffraction reveals that the composition and crystal quality of these photocathodes deposited on graphene is comparable to those deposited on a reference substrate. Quantitative agreement between optical calculations and QE measurements for the K2CsSb on free suspended graphene and a graphene-coated metal substrate further confirms the high-quality interface between the photocathodes and graphene. Finally, a correlation between the QE and graphene quality as characterized by Raman spectroscopy suggests that a lower density of atomistic defects in the graphene films leads to higher QE of the deposited K2CsSb photocathodes.

accelerator technology↗

Recovery Act: "Near-Single-Crystalline Photovoltaic Thin Films on Polycrystalline, Flexible Substrates" (Final Report)

III-V photovoltaics have exhibited efficiencies above 40%, but have found only a limited use because of the high cost of single crystal substrates. At the other end of the spectrum, polycrystalline and amorphous thin film solar cells offer the advantage of low-cost fabrication, but have not yielded high efficiencies. Our program is based on single-crystalline-like thin film photovoltaics on polycrystalline substrates using biaxially-textured templates made by Ion Beam-Assisted Deposition (IBAD). MgO templates made by IBAD on flexible metal substrate have been successfully used for epitaxial growth of germanium films. In spite of a 4.5% lattice mismatch, heteroepitaxial growth of Ge was achieved on CeO 2 that was grown on IBAD MgO template. Room temperature optical bandgap of the Ge films was identified at 0.67 eV indicating minimal residual strain. Refraction index and extinction coefficient values of the Ge films were found to match well with that measured from a reference Ge single crystal. GaAs has been successfully grown epitaxially on Ge on metal substrate by molecular beam epitaxy. RHEED patterns indicate self annihilation of antiphase boundaries and the growth of a single domain GaAs. The GaAs is found to exhibit strong photoluminescence signal and, an existence of a relatively narrow (FWHM~20 meV) band-edge excitons measured in this film indicates a good optoelectronic quality of deposited GaAs. While excellent epitaxial growth has been achieved in GaAs on flexible metal substrates, the defect density of the films as measured by High Resolution X-ray Diffraction and etch pit experiments showed a high value of 5 x 10 8 per cm 2 . Cross sectional transmission electron microscopy of the multilayer architecture showed concentration of threading dislocations near the germanium-ceria interface. The defect density was found decrease as the Ge films were made thicker. The defects appear to originate from the MgO layer presumably because of large lattice mismatches between the various layers. The defect density in GaAs was reduced by a factor of five by adding a step of in-situ deposition of Ge by MBE on the sputtered Ge prior to GaAs growth. We have investigated device design strategies that would support development of high-efficiency devices in presence of dislocation densities of 10 8 cm -2 present in our epitaxial GaAs films. Results from modeling work show that with a proper emitter, base and doping selection, the modeled efficiency of a GaAs cells with dislocation densities of 10 9 and 10 8 cm -2 could be increased from 1% and 7% to 11% and 17% respectively. Under AM0, this single junction GaAs solar cell, has optimized value of emitter and base thickness of around 0.7 and 1.7 microns respectively, to give a maximum efficiency of 24.2%. We have fabricated complete GaAs solar cells using our Ge films on metal substrates. Pattern resolution of few microns with well-defined grid line of 30 microns has been realized on few cm square flexible templates. The ability to grow single-crystalline-like Ge films on flexible, polycrystalline substrates by reel-to-reel tape processing now provides an immense potential to fabricate high quality III-V photovoltaics on flexible, inexpensive substrates.

14 SOLAR ENERGY↗

Recovery Act : Near-Single-Crystalline Photovoltaic Thin Films on Polycrystalline, Flexible Substrates

III-V photovoltaics have exhibited efficiencies above 40%, but have found only a limited use because of the high cost of single crystal substrates. At the other end of the spectrum, polycrystalline and amorphous thin film solar cells offer the advantage of low-cost fabrication, but have not yielded high efficiencies. Our program is based on single-crystalline-like thin film photovoltaics on polycrystalline substrates using biaxially-textured templates made by Ion Beam-Assisted Deposition (IBAD). MgO templates made by IBAD on flexible metal substrate have been successfully used for epitaxial growth of germanium films. In spite of a 4.5% lattice mismatch, heteroepitaxial growth of Ge was achieved on CeO2 that was grown on IBAD MgO template. Room temperature optical bandgap of the Ge films was identified at 0.67 eV indicating minimal residual strain. Refraction index and extinction coefficient values of the Ge films were found to match well with that measured from a reference Ge single crystal. GaAs has been successfully grown epitaxially on Ge on metal substrate by molecular beam epitaxy. RHEED patterns indicate self annihilation of antiphase boundaries and the growth of a single domain GaAs. The GaAs is found to exhibit strong photoluminescence signal and, an existence of a relatively narrow (FWHM~20 meV) band-edge excitons measured in this film indicates a good optoelectronic quality of deposited GaAs. While excellent epitaxial growth has been achieved in GaAs on flexible metal substrates, the defect density of the films as measured by High Resolution X-ray Diffraction and etch pit experiments showed a high value of 5 * 10^8 per cm^2. Cross sectional transmission electron microscopy of the multilayer architecture showed concentration of threading dislocations near the germanium-ceria interface. The defect density was found decrease as the Ge films were made thicker. The defects appear to originate from the MgO layer presumably because of large lattice mismatches between the various layers. The defect density in GaAs was reduced by a factor of five by adding a step of in-situ deposition of Ge by MBE on the sputtered Ge prior to GaAs growth. We have investigated device design strategies that would support development of high-efficiency devices in presence of dislocation densities of 10^8 cm^-2 present in our epitaxial GaAs films. Results from modeling work show that with a proper emitter, base and doping selection, the modeled efficiency of a GaAs cells with dislocation densities of 10^9 and 10^8 cm^-2 could be increased from 1% and 7% to 11% and 17% respectively. Under AM0, this single junction GaAs solar cell, has optimized value of emitter and base thickness of around 0.7 and 1.7 microns respectively, to give a maximum efficiency of 24.2%. We have fabricated complete GaAs solar cells using our Ge films on metal substrates. Pattern resolution of few microns with well-defined grid line of 30 microns has been realized on few cm square flexible templates. The ability to grow single-crystalline-like Ge films on flexible, polycrystalline substrates by reel-to-reel tape processing now provides an immense potential to fabricate high quality III-V photovoltaics on flexible, inexpensive substrates.

14 SOLAR ENERGY↗

Electrochemical measurement and analysis of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 in molten eutectic LiCl-KCl

For this work, electrochemical measurements of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 were obtained in molten LiCl-KCl eutectic at 773 K using a three-electrode configuration. Tungsten rods were used as the working and counter electrodes. Two quasi- and one reference electrode(s) (glassy carbon, nickel wire, and Ni/NiO) were used to collect electrochemical measurements of the analyte salts. Cyclic voltammetry data were analyzed to calculate values of diffusion coefficient, exchange current density, and charge transfer resistance and were determined to be on the order of 10 –5 cm 2 s –1 , 10 –2 A cm –2 , and 10 0 Ω; respectively. In general, the values of diffusion coefficients were found to be consistent with those reported of high-temperature molten salts. Relatively large values of exchange current density corresponded with smaller values of charge transfer resistance. These values were found to be reasonable in comparison to results available in the literature. The measured cyclic voltammograms were normalized with respect to both lithium reduction and chloride ion oxidation potentials. Such a normalization technique is effective for comparing experimentally obtained cyclic voltammetry data to those that have been published. An analysis of experimentally obtained results indicates the relation of electrode reactions (e.g., differences of reduction potentials) are independent of the choice of reference electrode. Additionally, the choice of reference electrode did not affect the electrochemical window, exchange current density, or diffusion coefficient values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TH-A-204-02: Part II - Worldwide Radiation Metrology

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

Can portable glucose and lactate meters be a useful tool in quantifying stress of juvenile Chinook salmon?

Blood plasma analyses can provide researchers, aquaculture facilities and fisheries managers with valuable insights into the physiological state and welfare of fish. For example, glucose and lactate are part of the secondary stress response system, and elevated concentrations are indicators of stress. However, analysing blood plasma in the field can be logistically difficult and typically involves sample storage and transport to quantify concentrations in a laboratory setting. Portable glucose and lactate meters offer an alternative to laboratory assays and have shown to be relatively accurate in fish, but these tools have only been validated for a few fish species. The objective of this study was to investigate if portable meters could be reliably used in Chinook salmon (Oncorhynchus tshawytscha). As part of a larger stress response study, juvenile Chinook salmon (157 ± 17 mm fork length [mean ± standard deviation; SD]) were exposed to stress-inducing treatments and sampled for blood. Laboratory reference glucose concentrations (milligrams per deciliter; mg/dl; n = 70) were positively correlated with the Accu-Check Aviva meter (Roche Diagnostics, Indianapolis, IN) measurements (R 2 = 0.79), although glucose values were 1.21 ± 0.21 (mean ± SD) times higher in the laboratory than with the portable meter. Lactate concentrations (milliMolar; mM; n = 52) of the laboratory reference were also positively correlated (R 2 = 0.76) with the Lactate Plus meter (Nova Biomedical, Waltham, MA) and were 2.55 ± 0.50 times higher than portable meter. Our results indicate both meters could be used to measure relative glucose and lactate concentrations in Chinook salmon and provide fisheries professionals with a valuable tool, particularly in remote field settings.

59 BASIC BIOLOGICAL SCIENCES↗