Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Multichannel Phase and Power Detector

An electronic signal-processing system determines the phases of input signals arriving in multiple channels, relative to the phase of a reference signal with which the input signals are known to be coherent in both phase and frequency. The system also gives an estimate of the power levels of the input signals. A prototype of the system has four input channels that handle signals at a frequency of 9.5 MHz, but the basic principles of design and operation are extensible to other signal frequencies and greater numbers of channels. The prototype system consists mostly of three parts: An analog-to-digital-converter (ADC) board, which coherently digitizes the input signals in synchronism with the reference signal and performs some simple processing; A digital signal processor (DSP) in the form of a field-programmable gate array (FPGA) board, which performs most of the phase- and power-measurement computations on the digital samples generated by the ADC board; and A carrier board, which allows a personal computer to retrieve the phase and power data. The DSP contains four independent phase-only tracking loops, each of which tracks the phase of one of the preprocessed input signals relative to that of the reference signal (see figure). The phase values computed by these loops are averaged over intervals, the length of which is chosen to obtain output from the DSP at a desired rate. In addition, a simple sum of squares is computed for each channel as an estimate of the power of the signal in that channel. The relative phases and the power level estimates computed by the DSP could be used for diverse purposes in different settings. For example, if the input signals come from different elements of a phased-array antenna, the phases could be used as indications of the direction of arrival of a received signal and/or as feedback for electronic or mechanical beam steering. The power levels could be used as feedback for automatic gain control in preprocessing of incoming signals. For another example, the system could be used to measure the phases and power levels of outputs of multiple power amplifiers to enable adjustment of the amplifiers for optimal power combining.

Li, Samuel↗

Vectorized Rebinning Algorithm for Fast Data Down-Sampling

A vectorized rebinning (down-sampling) algorithm, applicable to N-dimensional data sets, has been developed that offers a significant reduction in computer run time when compared to conventional rebinning algorithms. For clarity, a two-dimensional version of the algorithm is discussed to illustrate some specific details of the algorithm content, and using the language of image processing, 2D data will be referred to as "images," and each value in an image as a "pixel." The new approach is fully vectorized, i.e., the down-sampling procedure is done as a single step over all image rows, and then as a single step over all image columns. Data rebinning (or down-sampling) is a procedure that uses a discretely sampled N-dimensional data set to create a representation of the same data, but with fewer discrete samples. Such data down-sampling is fundamental to digital signal processing, e.g., for data compression applications.

Dean, Bruce↗

From Relativistic Electrons to X-ray Phase Contrast Imaging

We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphor’s 80-μm value. Potential fiber-optic plate depth-of-focus aspects and 33-μm diameter carbon fiber imaging are also addressed.

43 PARTICLE ACCELERATORS↗

Radiological Characterization of Selected Thermal Centres Based on Indoor Radon Dosimetry - 17507

In countries with long historical tradition in thermal water therapy and with several mineral-medicinal thermal sources, workplaces within thermal centers may be a source of radon exposure which may be intensified if these are located in regions of high level of natural radiation. According to the EU Directive 96/29/Euratom (repealed by the Directive 2013/59/EURATOM) each Member State shall identify, by means of survey or any other adequate mean, the work activities where a significant increase in the exposure from natural radiation sources may occur, including thermal centers where the exposure to thoron/radon daughters or gamma radiation may occur. The purpose of this work was to perform a radiological characterization of selected thermal centers based on indoor dosimetry. The effective doses received by workers due to radon inhalation were estimated and gamma dose rates were measured through continuous periods. The radon risk for indoor exposure was assessed on a probabilistic basis both on thermal centers and workers' dwellings. Radon levels within the thermal centers ranged from 73 to 4335 Bq/m{sup 3} and the values within the workers dwellings are of the same order of magnitude, 68-4051 Bq/m{sup 3}. Approximately 66 % of indoor radon concentration values are above the maximum EU reference (300 Bq/m{sup 3}) and 94 % of the effective dose is higher than 1 mSv/year. In some situations, radon levels at residential environments are much higher than at workplaces and effective doses are higher than 6 mSv/year, both at residential and work environments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Using Tally Values to Add a Third Dimension when Viewing Planar Mesh Tallies - Paper 95

Mesh tallies show a calculated quantity, such as radiation flux or dose rate, in cells of a rectangular, cylindrical, or spherical mesh. Mesh tallies are useful when the spatial distribution of the quantity is of interest. They are usually displayed in two dimensional (2D) plots with the tally values represented by color coding. Geometry outlines and/or contour lines may be included. Three dimensional (3D) views of rectangular tallies often show a set of tally planes within the geometry. We describe here a new 3D mesh tally plot where the third dimension of a rectangular mesh tally plane is determined by the tally value in each mesh cell. We refer to such plots as elevated mesh tally plots. These plots may aid in analysis and presentation of the results of a transport calculation. The results shown here were calculated with the Monte Carlo transport code MCNPX2.7. The plots were made with the White Rock Science visualization and geometry editing program Moritz. The elevated mesh tally plots have been implemented within Moritz. The elevation method is, at present, only applicable to rectangular mesh tallies. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

TRACE ELEMENT ANALYSES OF URANIUM MATERIALS

The Savannah River National Laboratory (SRNL) has developed an analytical method to measure many trace elements in a variety of uranium materials at the high part-per-billion (ppb) to low part-per-million (ppm) levels using matrix removal and analysis by quadrapole ICP-MS. Over 35 elements were measured in uranium oxides, acetate, ore and metal. Replicate analyses of samples did provide precise results however none of the materials was certified for trace element content thus no measure of the accuracy could be made. The DOE New Brunswick Laboratory (NBL) does provide a Certified Reference Material (CRM) that has provisional values for a series of trace elements. The NBL CRM were purchased and analyzed to determine the accuracy of the method for the analysis of trace elements in uranium oxide. These results are presented and discussed in the following paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reference tissue normalization in longitudinal 18F-florbetapir positron emission tomography of late mild cognitive impairment

Background: Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test–retest 18F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. Methods: We calculated the correlation between 18F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1–42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique—the weighted two-point correlation function (wS2)—to capture potentially more subtle changes in Aβ-PET data. Results: Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1–42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1–42 levels across all time points and reference regions, including the cerebellar gray matter. Conclusions: The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical 18F-florbetapir uptake in longitudinal studies.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROPERTIES OF THE ACCELERATION REGIONS IN SEVERAL LOOP-STRUCTURED SOLAR FLARES

Using RHESSI hard X-ray imaging spectroscopy observations, we analyze electron flux maps for a number of extended coronal loop flares. For each event, we fit a collisional model with an extended acceleration region to the observed variation of loop length with electron energy E, resulting in estimates of the plasma density in, and longitudinal extent of, the acceleration region. These quantities in turn allow inference of the number of particles within the acceleration region and hence the filling factor f-the ratio of the emitting volume to the volume that encompasses the emitting region(s). We obtain values of f that lie mostly between 0.1 and 1.0; the (geometric) mean value is f = 0.20 Multiplication-Sign / Division-Sign 3.9, somewhat less than, but nevertheless consistent with, unity. Further, coupling information on the number of particles in the acceleration region with information on the total rate of acceleration of particles above a certain reference energy (obtained from spatially integrated hard X-ray data) also allows inference of the specific acceleration rate (electron s{sup -1} per ambient electron above the chosen reference energy). We obtain a (geometric) mean value of the specific acceleration rate {eta}(20 keV) =(6.0 Multiplication-Sign / Division-Sign 3.4) Multiplication-Sign 10{sup -3} electrons s{sup -1} per ambient electron; this value has implications both for the global electrodynamics associated with replenishment of the acceleration region and for the nature of the particle acceleration process.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of the Spectral Stability of Libya 4, Libya 1, and Mauritania 2 Sites Using Earth Observing One Hyperion

The objective of this paper is to formulate a methodology to assess the spectral stability of the Libya 4, Libya 1, and Mauritania 2 pseudo-invariant calibration sites (PICS) using Earth Observing One (EO-1) Hyperion sensor. All the available Hyperion collections, downloaded from the Earth Explorer website, were utilized for the three PICS. In each site, a reference spectrum is selected at a specific day in the vicinity of the region of interest (ROI) defined by Committee on Earth Observation Satellites (CEOS). A series of ROIs are predefined in the along-track direction with 196 spectral top-of-atmosphere reflectance values in each ROI. Based on the reference ROI spectrum, the spectral stability of these ROIs is evaluated by average deviations (ADs) and spectral angle mapper (SAM) methods in the specific ranges of time and geo-spatial locations. Time and ROI location-dependent SAM and AD results are very stable within +/- 2 deg and +/-1.7% of 1sigma standard deviations. Consequently, the Libya 4, Mauritania 2, and Libya 1 CEOS selected PICS are spectrally stable targets within the time and spatial swath ranges of the Hyperion collections.

average deviation↗

Inflationary spectra with inverse-volume corrections in loop quantum cosmology and their observational constraints from Planck 2015 data

We first derive the primordial power spectra, spectral indices and runnings of both scalar and tensor perturbations of a flat inflationary universe to the second-order approximations of the slow-roll parameters, in the framework of loop quantum cosmology with the inverse-volume quantum corrections. This represents an extension of our previous work in which the parameter σ was assumed to be an integer, where σ characterizes the quantum corrections and in general can take any of values from the range σ element of (0, 6]. Restricting to the first-order approximations of the slow-roll parameters, we find corrections to the results obtained previously in the literature, and point out the causes for such errors. To our best knowledge, these represent the most accurate calculations of scalar and tensor perturbations given so far in the literature. Then, fitting the perturbations to the recently released data by Planck (2015), we obtain the most severe constraints for various values of σ. Using these constraints as our referring point, we discuss whether these quantum gravitational corrections can lead to measurable signatures in the future cosmological observations. We show that, depending on the value of σ, the scale-dependent contributions to the relativistic inflationary spectra due to the inverse-volume corrections could be well within the range of the detectability of the forthcoming generations of experiments, such as the Stage IV experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Data from: Multiple maize reference genomes impact the identification of variants by GWAS in a diverse inbred panel

Use of a single reference genome for genome-wide association studies (GWAS) limits the gene space represented to that of a single accession. This limitation can complicate identification and characterization of genes located within presence/absence variations (PAVs). In this study, we present the draft de novo genome assembly of PHJ89, an Oh43-type inbred line. Using three separate reference genome assemblies (B73, PH207, and PHJ89) that represent the predominant germplasm groups of maize, we generated three separate whole-seedling gene expression profile and single nucleotide polymorphism (SNP) matrices from a panel of 942 diverse inbred lines. We identified 34,447 (B73), 39,672 (PH207), and 37,436 (PHJ89) transcripts that are not present in the respective reference genome assembly. GWAS was conducted in the 942 inbred panel using both the SNP and expression data values to map sugarcane mosaic virus (SCMV) resistance. Highlighting the impact of alternative reference genomes in gene discovery, GWAS results for SCMV resistance using expression values as a surrogate measure of PAV resulted in robust detection of the physical location of a known resistance gene when using the B73 reference that contains the gene, but not when using the PH207 reference. This study provides the valuable resource of the Oh43-type PHJ89 genome assembly as well as SNP and expression data for 942 individuals generated using three different reference genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Aquatic Natural Areas Analysis and Evaluation: Oak Ridge Reservation

This report presents an assessment of the natural area value of eight Aquatic Natural Areas (ANAs) and seven Aquatic Reference Areas (ARAs) on the Oak Ridge Reservation (ORR) in Anderson and Roane Counties in east Tennessee. It follows a previous study in 2009 that analyzed and evaluated terrestrial natural areas on the Reservation. The purpose of both studies was to evaluate and rank those specially designated areas on the Reservation that contain sensitive species, special habitats, and natural area value. Natural areas receive special protections through established statutes, regulations, and policies. The ORR contains 33,542 acres (13,574 ha) administered by the Department of Energy. The surface waters of the Reservation range from 1st-order to 5th-order streams, but the majority of the streams recognized as ANAs and ARAs are 1st- and 2nd-order streams. East Fork Poplar Creek is a 4th-order stream and the largest watershed that drains Reservation lands. All the waters of the Reservation eventually reach the Clinch River on the southern and western boundaries of the ORR. All available information was collected, synthesized, and evaluated. Field observations were made to support and supplement the available information. Geographic information system mapping techniques were used to develop several quantitative attributes about the study areas. Narrative descriptions of each ANA and ARA and tables of numerical data were prepared. Criteria for assessment and evaluation were developed, and eight categories of factors were devised to produce a ranking system. The evaluation factors used in the ranking system were: (A) size of area, (B) percentage of watershed protected, (C) taxa present with protected status, (D) overall biotic diversity, (E) stream features, (F) water quality and use support ratings, (G) disturbance regime, and (H) other factors. Each factor was evaluated on a 5-point ranking scale (0-4), and each area received a composite score, where 32 was the maximum score possible. A highly ranked ANA or ARA is one that is large in size compared to other areas, includes a greater proportion of the watershed within Reservation boundaries, contains a number of status taxa at high densities, exhibits a high overall biodiversity, has very good or excellent habitat and water quality, is well protected and isolated from disturbances, and shows several other characteristics that contribute to natural area value. In this report, the term 'natural area' is loosely defined as a terrestrial or aquatic system that exhibits, or is thought to exhibit, high natural integrity and other significant natural values. The purpose of the present study is to evaluate and rank the currently recognized Aquatic Natural Areas (ANAs) and Aquatic Reference Areas (ARAs) on the Oak Ridge Reservation (ORR) for their natural area value. A previous study (Baranski 2009) analyzed, evaluated, and ranked terrestrial areas (Natural Areas [NAs], Reference Areas [RAs], and Cooperative Management Areas [CMAs]) on the ORR for natural area value, and a precise methodology for natural area evaluation was developed. The present study is intended to be a complement and companion to the terrestrial area study and attempts to employ a similar methodology for aquatic areas so that aquatic and terrestrial areas can be compared on a similar scale. This study specifically develops criteria for assessing the ecological, biodiversity, and natural area importance and significance of aquatic systems on the Reservation in a relevant and consistent manner. The information can be integrated into the Tennessee Natural Heritage Program (http://tn.gov/environment/na/nhp.shtml) system and applied to potential new aquatic areas. Further, the information will be useful in planning, management, and protection efforts on the ORR.

54 ENVIRONMENTAL SCIENCES↗

SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a clinical setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geologic exploration: The contribution of LANDSAT-4 thematic mapper data

The major advantages of the TM data over that of MSS systems are increased spatial resolution and a greater number of narrow, strategically placed spectral bands. The 30 meter pixel size permits finer definition of ground features and improves reliability of the photointerpretation of geologic structure. The value of the spatial data increases relative to the value of the spectral data as soil and vegetation cover increase. In arid areas with good exposure, it is possible with careful digital processing and some inventive color compositing to produce enough spectral differentiation of rock types and thereby produce facsimiles of standard geologic maps with a minimum of field work or reference to existing maps. Hue-saturation value images are compared with geological maps of Death Valley, California, the Big Horn/Wind River Basin of Wyoming, the area around Cement, Oklahoma, and Detroit. False color composites of the Ontario region are also examined.

Everett, J. R.↗

An empirical study of FORTRAN programs for parallelizing compilers

Some results are reported from an empirical study of program characteristics that are important in parallelizing compiler writers, especially in the area of data dependence analysis and program transformations. The state of the art in data dependence analysis and some parallel execution techniques are examined. The major findings are included. Many subscripts contain symbolic terms with unknown values. A few methods of determining their values at compile time are evaluated. Array references with coupled subscripts appear quite frequently; these subscripts must be handled simultaneously in a dependence test, rather than being handled separately as in current test algorithms. Nonzero coefficients of loop indexes in most subscripts are found to be simple: they are either 1 or -1. This allows an exact real-valued test to be as accurate as an exact integer-valued test for one-dimensional or two-dimensional arrays. Dependencies with uncertain distance are found to be rather common, and one of the main reasons is the frequent appearance of symbolic terms with unknown values.

Shen, Zhiyu↗

Comparison of z-known GRBs with the Main Groups of Bright BATSE Events

The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.

Mitrofanov, Igor G.↗