Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Shipping Anomaly from NMIS Imaging

In 2007, a shipping container that arrived at ORNL was imaged using the neutron and gamma ray imaging capability of Nuclear Materials Identification System (NMIS). NMIS with imaging uses a time-tagged radiation source, which can be either a DT neutron generator or a 252Cf spontaneous fission source. The initial imaging measurements used the DT generator s 14.1 MeV neutrons. Because of the low attenuation of the container and its contents, subsequent measurements were performed with the fission energy spectrum neutrons and gamma rays of the 252Cf source. The 252Cf source provides a simultaneous measurement of both a neutron (more sensitive to organics) and a gamma ray (more sensitive to steels) image to be obtained. The images showed that the container contents were partially inverted instead of their expected arrangement. This information was useful in assessing the shipment packaging before the container was opened and indicates how NMIS with imaging can be used to image receipts.

36 MATERIALS SCIENCE↗

Ion composition and drift observations in the nighttime equatorial ionosphere

The first in situ measurements of ion composition in the nighttime equatorial E and F region ionospheres (90-300 km) are presented and discussed. These profiles were obtained by two rocket-borne ion mass spectrometers launched from Thumba, India on March 9-10, 1970 at solar zenith angles of 112 deg and 165 deg. Ionosonde data established that the composition was measured at times bounding a period of F region downward drift. During this period the ions O(+) and N(+) were enhanced by one to three orders of magnitude between 220 and 300 km. Below the drift region (200 km), O(+) ceased to be the major ionic constituent, but the concentrations of O(+) and N(+) remained larger than predicted from known radiation sources and loss processes. Here also, both the O2(+) and NO(+) profiles retained nearly the same shape and magnitude throughout the night in agreement with theories assuming scattered UV radiation to be the maintaining source. Light metallic ions including Mg(+), Na(+) and possibly Si(+) were observed to altitude approaching 300 km, while the heavier ions Ca(+) and K(+) were seen in reduced quantity to 200 km. All metal ion profiles exhibited changes which can be ascribed to vertical drifting.

Goldberg, R. A.↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

Watts Bar I Ex-Core Analyses using VERA

The integration and direct coupling of the Oak Ridge National Laboratory (ORNL) Shift Monte Carlo code within the Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) offers unique capabilities that combine high-fidelity in-core and ex-core radiation transport. In this recent development activity, the deterministic neutronics code MPACT performs the incore radiation transport with temperature feedback using COBRA-TF (CTF), and provides the fission source to Shift for a follow-on fixed source radiation transport calculation to determine ex-core quantities of interest. The coupling of MPACT to Shift allows the neutron source for the ex-core transport to be calculated from the time-dependent, fully coupled MPACT solution. This paper presents the first use of VERA to perform coupon irradiation for validation of its ex-core capabilities.

Davidson, Eva↗

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Real-Time Dosimetry for Radiobiology Experiments Using 25 MeV LINAC

The next generation of radiobiology research requires increasingly more complex radiation sources to address questions ranging from the effects of space-based radiation to the influence of dose rate on biological systems. The Idaho Accelerator Center (IAC) has developed a radiobiology research facility to address some of these questions. The irradiation challenge is to deliver stable and reproducible conditions of high dose rate with well-controlled beam uniformity, dose, and dose rate under controlled temperature. In this work, we used a 25 MeV modified medical grade linear accelerator (LINAC) to obtain a high and adjustable electron dose rate. To overcome electron beam drift we used a collimator that both assisted the LINAC operator to steer the beam and ensured that regardless of beam drift, only the fixed collimated beam would irradiate the specimens. In addition, we utilized a beam flattener to keep the beam variation as low as 3% at 2.5 cm from the beam's center, and 1% variation between the simultaneously irradiated sample tubes. We also demonstrated that a segmented Faraday 'cup'(FC) array provides a useful real-time beam scanning and monitoring system, and is promising for implementing real-time dosimetry and control.

43 PARTICLE ACCELERATORS↗

Ion composition and drift observations in the nighttime equatorial ionosphere

The first in situ measurements of ion composition in the nighttime equatorial E- and F-region ionospheres are presented and discussed. These profiles were obtained by two rocket-borne ion mass spectrometers launched from Thumba, India, on March 9-10, 1970. Ionosonde data established that the composition was measured at times bounding a period of F-region downward drift. During this period, the ions O(+) and N(+) were enhanced by 1-3 orders of magnitude between 220 and 300 km. Below the drift region, O(+) ceased to be the major ionic constituent, but the concentrations of O(+) and N(+) remained larger than predicted from known radiation sources and loss processes. Here also, both the O2(+) and the NO(+) profiles retained nearly the same shape and magnitude throughout the night in agreement with theories assuming scattered UV radiation to be the maintaining source.

Goldberg, R. A.↗

The History of X-ray Free-Electron Lasers

The successful lasing at the SLAC National Accelerator Laboratory of the Linear Coherent Light Source (LCLS), the first X-ray free-electron laser (X-ray FEL), in the wavelength range 1.5 to 15 {angstrom}, pulse duration of 60 to few femtoseconds, number of coherent photons per pulse from 10{sup 13} to 10{sup 11}, is a landmark event in the development of coherent electromagnetic radiation sources. Until now electrons traversing an undulator magnet in a synchrotron radiation storage ring provided the best X-ray sources. The LCLS has set a new standard, with a peak X-ray brightness higher by ten orders of magnitudes and pulse duration shorter by three orders of magnitudes. LCLS opens a new window in the exploration of matter at the atomic and molecular scales of length and time. Taking a motion picture of chemical processes in a few femtoseconds or less, unraveling the structure and dynamics of complex molecular systems, like proteins, are some of the exciting experiments made possible by LCLS and the other X-ray FELs now being built in Europe and Asia. In this paper, we describe the history of the many theoretical, experimental and technological discoveries and innovations, starting from the 1960s and 1970s, leading to the development of LCLS.

43 PARTICLE ACCELERATORS↗

Novel Large Area High Resolution Neutron Detector for the Spallation Neutron Source

Neutron scattering is a powerful technique that is critically important for materials science and structural biology applications. The knowledge gained from past developments has resulted in far-reaching advances in engineering, pharmaceutical and biotechnology industries, to name a few. New facilities for neutron generation at much higher flux, such as the SNS at Oak Ridge, TN, will greatly enhance the capabilities of neutron scattering, with benefits that extend to many fields and include, for example, development of improved drug therapies and materials that are stronger, longer-lasting, and more impact-resistant. In order to fully realize this enhanced potential, however, higher neutron rates must be met with improved detection capabilities, particularly higher count rate capability in large size detectors, while maintaining practicality. We have developed a neutron detector with the technical and economic advantages to accomplish this goal. This new detector has a large sensitive area, offers 3D spatial resolution, high sensitivity and high count rate capability, and it is economical and practical to produce. The proposed detector technology is based on B-10 thin film conversion of neutrons in long straw-like gas detectors. A stack of many such detectors, each 1 meter in length, and 4 mm in diameter, has a stopping power that exceeds that of He-3 gas, contained at practical pressures within an area detector. With simple electronic readout methods, straw detector arrays can provide spatial resolution of 4 mm FWHM or better, and since an array detector of such form consists of several thousand individual elements per square meter, count rates in a 1 m^2 detector can reach 2?10^7 cps. Moreover, each individual event can be timetagged with a time resolution of less than 0.1 ?sec, allowing accurate identification of neutron energy by time of flight. Considering basic elemental cost, this novel neutron imaging detector can be commercially produced economically, probably at a small fraction of the cost of He-3 detectors. In addition to neutron scattering science, the fully developed base technology can be used as a rugged, low-cost neutron detector in area monitoring and surveying. Radiation monitors are used in a number of other settings for occupational and environmental radiation safety. Such a detector can also be used in environmental monitoring and remote nuclear power plant monitoring. For example, the Department of Energy could use it to characterize nuclear waste dumps, coordinate clean-up efforts, and assess the radioactive contaminants in the air and water. Radiation monitors can be used to monitor the age and component breakdown of nuclear warheads and to distinguish between weapons and reactor grade plutonium. The UN's International Atomic Energy Agency (IAEA) uses radiation monitors for treaty verification, remote monitoring, and enforcing the non-proliferation of nuclear weapons. As part of treaty verification, monitors can be used to certify the contents of containers during inspections. They could be used for portal monitoring to secure border checkpoints, sea ports, air cargo centers, public parks, sporting venues, and key government buildings. Currently, only 2% of all sea cargo shipped is inspected for radiation sources. In addition, merely the presence of radiation is detected and nothing is known about the radioactive source until further testing. The utilization of radiation monitors with neutron sensitivity and capability of operation in hostile port environments would increase the capacity and effectiveness of the radioactive scanning processes.

47 OTHER INSTRUMENTATION↗

Experimental evidence and theoretical analysis of photoionized plasma under x-ray radiation produced by an intense laser

Photoionized plasma was studied experimentally under laboratory conditions by means of high intensity short pulse lasers. The experiment consists of a gold cavity filled with nitrogen gas. Six laser beams were focused on the inner surface of the gold cavity, thereby generating an almost black-body radiation having temperature of 80 eV inside the cavity. This radiation heats the nitrogen gas mainly by means of photoionization. L-shell emissions from N V to N VII have been observed in the wavelength range between 90 and 200 A. A time-dependent Detailed Configuration Accounting computer program has been developed to analyze the experimental spectra. In contrast to standard analysis of astrophysical observations, the evidence for photoionization is inferred from the spectral lines ratios. Comparison between the experimental and simulated line spectra indicates that the radiation heated nitrogen attains temperature of 20-30 eV, much lower than the source radiation temperature. Paradoxically, it is also shown that similar line emissions can be reproduced computationally also when the radiation and plasma temperatures both equal approximately 60 eV. This misleading result indicates that experimental simulation in laboratory is sometimes necessary to avoid misinterpretation of astrophysical spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Radiation, Radiation Measurement and the JLab APEX Experiment

The A-prime Experiment (APEX), which is approved to run at the Thomas Jefferson Accelerator Facility (JLab) Hall A, will search for a new vector boson that is hypothesized to be a possible force carrier that couples to dark matter. APEX results should be sensitive to the mass range of 65 MeV to 550 MeV, and high sensitivity will be achieved by means of a high intensity 100 muA beam on a 0.3 g/cm 2 Tungsten target resulting in very high luminosity. The experiment should be able to observe an A-prime with a coupling constant 1 x 10 7 times smaller than the electromagnetic coupling constant. To deal safely with such enormous intensity and luminosity, a full radiation analysis must be used. A Geant4 Monte Carlo simulation was performed to study the radiation environments expected in the JLab Hall A during the APEX experiment. We benchmarked our simulations with measurements carried out during past experiments such as the Pb Radius Experiment (PREX-I). Our PREX-I simulations agreed reasonably well with measurements performed by measuring the change in dark current in a Silicon Photomultipliers as a means of radiation damage. However, our simulations were initially significantly higher than the neutron dose measurements (using NP100) in Hall A. The apparent disagreement hints to several potential problems in NP100 measurements including the dead-time. Further, we identified radiation sources in the beam line and tested several shielding strategies to lower the radiation in Hall A. We characterized several thermal neutron detectors and also studied possibility of damage to electronics due to neutron radiation. We successfully demonstrated that the APEX experiment can be carried out in JLab Hall A without worrying about radiation damage to expensive electronics. The A-prime will appear as a narrow resonance in the invariant mass spectrum of e + e - pairs resulting from the electron beam scattering off the APEX target. In this search for the A-prime, it is critical to have a good mass resolution which is mainly dominated by the track measurement uncertainties. We studied a novel method to calibrate the HRS optics which will improve the accuracy of track measurements. Our results will be used to design HRS calibration runs for the APEX experiment.

Kaluarachchi, Maduka↗

Solar radiation calibration facility.

A recently completed calibration facility for the NASA Mississippi Test Site is described. It combines the spectrum of water cooled long arc xenon radiation sources with the integration sphere concept covered by a special barium sulfate diffusely reflecting paint. The sphere is six feet in diameter and completely encompasses the four xenon sources (2.5 kW each) and the five pyranometers under calibration. The sources are contained within the base of the central pedestal and allow the radiation to be emitted into the lower hemisphere. Only through diffuse reflection and multiple scattering is the radiation finally incident upon the test zone, which is in the equatorial plane of the sphere on the top of the pedestal. The sphere is temperature controlled.

Hershey, T. L.↗

Optical Radiation from Shock-Compressed Materials

Recent observations of shock-induced radiation from oxides, silicates, and metals of geophysical interest constrain the shock-compressed temperature of these materials. The relationships between the temperature inferred from the observed radiation and the temperature of the shock-compressed film or foil and/or window were investigated. Changes of the temperature field in each target component away from that of their respective shock-compressed states occur because of: shock-impedance mismatch between target components; thermal mismatch between target components; surface roughness at target interfaces; and conduction within and between target components. In particular, conduction may affect the temperature of the film/foil window interface on the time scale of the experiments, and so control the intensity and history of the dominant thermal radiation sources in the target. This type of model was used to interpret the radiation emitted by a variety of shock-compressed materials and interfaces.

Svendsen, Robert F., Jr.↗

Oscillator strengths for Fe II transitions at 224.918 and 226.008 nanometers

We report accurate experimental absorption oscillator strengths (f-values) for transitions out of the ground level of Fe II to the Z(sup 4)D(sup 0 sub 7/2) and z(sup 4)F(sup 0 sub 9/2) levels at 224.918 and 226.008 nm (air wavelengths) to be 0.00182(14) and 0.00244(19), respectively. The number in parenthesis is the uncertainty in the last digits. These two lines are important for studying Fe abundances and grain depletions in the interstellar medium. These f-values are determined by combining emission branching fractions with radiative lifetimes. Branching fractions are measured using classical spectroradiometry on an optically thin source. Radiative lifetimes are from the literature.

Bergeson, S. D.↗

Fluence Uniformity Measurements in an Electron Accelerator Used for Irradiation of Extended Area Solar Cells and Electronic Circuits for Space Applications

It is common to have liquid crystal displays and electronic circuit boards with area sizes of the order of 20x20 sq cm on board of satellites and space vehicles. Usually irradiating them at different fluence values assesses the radiation damage in these types of devices. As a result, there is a need for a radiation source with large spatial fluence uniformity for the study of the damage by radiation from space in those devices. Kent State University s Program on Electron Beam Technology has access to an electron accelerator used for both research and industrial applications. The electron accelerator produces electrons with energies in the interval from 1 to 5 MeV and a maximum beam power of 150 kW. At such high power levels, the electron beam is continuously scanned back and forth in one dimension in order to provide uniform irradiation and to prevent damage to the sample. This allows for the uniform irradiation of samples with an area of up to 1.32 sq m. This accelerator has been used in the past for the study of radiation damage in solar cells (1). However in order to irradiate extended area solar cells there was a need to measure the uniformity of the irradiation zone in terms of fluence. In this paper the methodology to measure the fluence uniformity on a sample handling system (linear motion system), used for the irradiation of research samples, along the irradiation zone of the above-mentioned facility is described and the results presented. We also illustrate the use of the electron accelerator for the irradiation of large area solar cells (of the order of 156 sq cm) and include in this paper the electrical characterization of these types of solar cells irradiated with 5 MeV electrons to a total fluence of 2.6 x 10(exp 15) e/sq cm.

Uribe, Roberto M.↗

Electricity generation using electromagnetic radiation

In general, in one aspect, the invention relates to a system to create vapor for generating electric power. The system includes a vessel comprising a fluid and a complex and a turbine. The vessel of the system is configured to concentrate EM radiation received from an EM radiation source. The vessel of the system is further configured to apply the EM radiation to the complex, where the complex absorbs the EM radiation to generate heat. The vessel of the system is also configured to transform, using the heat generated by the complex, the fluid to vapor. The vessel of the system is further configured to sending the vapor to a turbine. The turbine of the system is configured to receive, from the vessel, the vapor used to generate the electric power.

24 POWER TRANSMISSION AND DISTRIBUTION↗