Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The polarization of the far-infrared radiation from the Galactic center

The first detection of linear polarization of the far-infrared (100-micron) radiation from the about 3-pc-diameter dust ring surrounding the galactic nucleus is reported. The percentage of polarization is between 1 and 2 percent at the three measured positions. It is argued that the polarized radiation is produced by thermal emission from elongated interstellar grains oriented by the local magnetic field. The dust ring is optically thin at 100 microns; therefore the observations sample dust through the entire depth of the cloud and are free of confusing effects due to embedded sources, scattering, or selective absorption. These data provide the first information about the configuration of the magnetic field in the dust ring.

Werner, M. W.↗

Double photon excitation of high-Rydberg atoms as a long-lived submillimeter detector

A method and apparatus for detecting submillimeter or IR radiation is disclosed. A rare gas, such as xenon, is supplied at its ground state via a pressurized cylinder and an adjustable leak valve into a cryogenically cooled detection area. The ground state of xenon is double photon excited to a particularized level of the Rydberg series by a resonance lamp and a laser. The doubly excited gas is then further excited by the radiation to be measured. A field ionization and an ion measurement indicative of the radiation intensity is achieved.

Chutjian, A. N.↗

Advantages of Measuring the Q Stokes Parameter in Addition to the Total Radiance I in the Detection of Absorbing Aerosols: a Proof of Concept Using Vector Radiative Transfer, Neural Networks, and Optimal Estimation

A simple but novel study was conducted to investigate whether an imager-type spectroradiometer instrument like MODIS, currently flying on board the Aqua and Terra satellites, or MERIS, which flew on board Envisat, could detect absorbing aerosols if they could measure the Q Stokes parameter in addition to the total radiance I, that is if they could also measure the linear polarization of the light. Accurate radiative transfer calculations were used to train a fast neural network forward model, which together with a simple statistical optimal estimation scheme was used to retrieve three aerosol parameters: aerosol optical depth, fraction of absorbing aerosols, and aerosol location. The aerosols were assumed to be located either between 0 and 2 km or between 2 and 4 km in the Earth’s atmosphere. From simulated data it was found that by itself the total radiance I was generally insufficient to retrieve all three aerosol parameters, but that together with the Q Stokes component it was possible to reliably retrieve values of aerosol optical depth, fraction, and location.

Stamnes, Snorre↗

External Radiation and Magnetic-Field Effects on the Coherence and Stability of Transmon Qubits

Superconducting transmon qubits are a central building block of modern quantum computing architectures, yet their coherence properties remain sensitive to external influences that can limit performance or introduce temporal instabilities. In this talk, I will discuss two experimental studies aimed at quantifying these effects. First, I will examine how ionizing radiation impacts qubit relaxation. Using the same transmon device operated at two locations with dramatically different radiation backgrounds—the above-ground SQMS facility at Fermilab (USA) and the deep-underground Gran Sasso Laboratory (Italy)—we observe a higher rate of radiation-induced decay events above ground, even though intrinsic noise remains the dominant source of single-shot errors. I will also discuss the detection efficiency of a radiation detector made using such a device. Second, I will present results on how small magnetic fields, applied either during cooldown or at millikelvin temperatures, influence device stability. We find that fixed-frequency transmons maintain robust coherence up to approximately 600 mG of trapped out-of-plane field, and that controlled application of magnetic field can reduce temporal fluctuations in T1. Together, these studies provide insight into how external environments shape transmon coherence and offer potential pathways for improving qubit stability in scalable quantum processors.

Roy, Tanay [Fermilab]↗

Radiation-Tolerant Intelligent Memory Stack - RTIMS

This innovation provides reconfigurable circuitry and 2-Gb of error-corrected or 1-Gb of triple-redundant digital memory in a small package. RTIMS uses circuit stacking of heterogeneous components and radiation shielding technologies. A reprogrammable field-programmable gate array (FPGA), six synchronous dynamic random access memories, linear regulator, and the radiation mitigation circuits are stacked into a module of 42.7 42.7 13 mm. Triple module redundancy, current limiting, configuration scrubbing, and single- event function interrupt detection are employed to mitigate radiation effects. The novel self-scrubbing and single event functional interrupt (SEFI) detection allows a relatively soft FPGA to become radiation tolerant without external scrubbing and monitoring hardware

Ng, Tak-kwong↗

Electrical Breakdown of Anodized Structures in a Low Earth Orbital Environmental

A comprehensive set of investigations involving arcing on a negatively biased anodized aluminum plate immersed in a low density argon plasma at low pressures (P(sub O), 7.5 x 10(exp -5) Torr) have been performed. These arcing experiments were designed to simulate electrical breakdown of anodized coatings in a Low Earth Orbital (LEO) environment. When electrical breakdown of an anodized layer occurs, an arc strikes, and there is a sudden flux of electrons accelerated into the ambient plasma. This event is directly followed by ejection of a quasi-neutral plasma cloud consisting of ejected material blown out of the anodized layer. Statistical analysis of plasma cloud expansion velocities have yielded a mean propagation velocity, v = (19.4 +/- 3.5) km/s. As the plasma cloud expands into the ambient plasma, energy in the form of electrical noise is generated. The radiated electromagnetic noise is detected by means of an insulated antenna immersed in the ambient plasma. The purpose of the investigations is (1) to observe and record the electromagnetic radiation spectrum resulting from the arcing process. (2) Make estimates of the travel time of the quasi-neutral plasma cloud based on fluctuations to several Langmuir probes mounted in the ambient plasma. (3) To study induced arcing between two anodized aluminum structures in close proximity.

Galofaro, J. T.↗

Modeling the Transmission of Optical Lightning Signals Through Complex 3‐D Cloud Scenes

Abstract Space‐based lightning imagers have shown that complex cloud scenes consisting of multiple tall convective features, anvil clouds, and warm boundary cloud layers are illuminated by lightning in many different ways depending on where the lightning occurs and how energetic it is. Modifications to the optical lightning signals from radiative transfer in the cloud medium can lead to reductions in detection efficiency and location accuracy for these instruments and can also cause some of the optical signals that are detected to have unexpected spatial energy distributions. In this study, we perform Monte Carlo radiative transfer simulations of optical lightning emissions in clouds with complex 3‐D geometries to shed some light on the origins of certain irregular radiance patterns that have been recorded from orbit. We show that diffuse reflections off nearby cloud faces can explain lightning signals in nonelectrified clouds, tall clouds can result in poor optical transmission and suppressed radiances that could lead to missed events and that particularly favorable viewing conditions can cause otherwise normal lightning to produce a superbolt that is orders of magnitude brighter than the same flash seen from a different angle.

54 ENVIRONMENTAL SCIENCES↗

Low frequency gyro-synchrotron radio noise from the earth's outer radiation belt

The problem of detecting cyclotron and synchrotron noise from superthermal electrons is analyzed for the frequency range 30 kHz 300 kHz. Due to the earth's ionosphere, ground based observation of this noise is improbable. Therefore, the calculations are made for an observer in the interplanetary medium. In particular, the location is chosen in the geomagnetic equatorial plane at a geocentric distance of 32 earth radii. This position of the observer allows the theoretical results to be compared directly with data obtained from the radio astronomy experiment aboard the IMP-6 spacecraft.

Frankel, M. S.↗

TeV radiation from galactic sources

The detection of the Crab Nebula as a steady source of TeV gamma rays puts the field of Very High Energy Gamma-Ray Astronomy on a firm observational basis and permits a critical reassessment of the claims for the detection of a multitude of episodic binary sources. A new generation of detectors in the TeV and PeV energy regions is coming on-line; together with the telescopes of the Gamma-Ray Observatory, these instruments will present a new perspective on one of the last frontiers of astronomy.

Weekes, Trevor C.↗

SAS 2 observation of pulsed high-energy gamma radiation from Geminga

Following the detection of pulsed X-rays and gamma rays from Geminga, the 1972-1973 SAS 2 data which first revealed this source have been reanalyzed. The 237 ms periodicity is visible in those observations. The phase of the SAS 2 periodicity is consistent with that of COS B suggesting that the gamma-ray data allow an accounting for every revolution of the Geminga pulsar between 1972 and 1982.

Mattox, J. R.↗

Using ACIS on the Chandra X-ray Observatory as a Particle Radiation Monitor II

The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.

Grant, C. E.↗

Holographic particle detection

The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.

Bowen, Theodore↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗

Detecting Nighttime Fire Combustion Phase by Hybrid Application of Visible and Infrared Radiation from Suomi NPP VIIRS

An accurate estimation of biomass burning emissions is 1 partially limited by the lack of knowledge of fire burning phase (smoldering vs. flaming). In recent years, several fire detection products have been developed to provide information of fire radiative power (FRP), location, size, and temperature of fire pixels, but no information regarding fire burning phase is retrieved. The Day-Night band (DNB) aboard Visible Infrared Imaging Radiometer Suite (VIIRS) is sensitive to visible light from flaming fires in nighttime scenes. In contrast, VIIRS 4 m moderate resolution band #13 (M13), though capable of detecting fires at all phases, has no direct sensitivity for discerning fire phase. However, the hybrid usage of VIIRS DNB and M-bands data is hampered by their different scanning technology and spatial resolution. In this study, we present a novel method to rapidly and accurately resample DNB pixel radiances to the footprint of M-band pixels, accounting for onboard detector aggregation schemes and bowtie effect removals. The visible energy fraction (VEF) is subsequently introduced as an indicator of fire burning phase VEF is calculated as the ratio of visible light power (VLP) to FRP for each fire pixel retrieved from the VIIRS 750 m active fire product. A global distribution of VEF values, and thereby the fire phase, is quantitatively obtained, showing smaller VEF values in regions with mostly smoldering wildfires, such as peatland fires in Indonesia, larger VEF values in regions with flaming wildfires over grasslands and savannas in the sub-Sahelian region, and the largest VEF values associated with gas flaring in the Middle East. Mean VEF for different land cover types or regions is highly correlated with modified combustion efficiency (MCE). These results, together with a case study of the 2018 California Camp Fire, show that the VEF has the potential to be an indicator of fire combustion phase for each fire pixel, appropriate for estimating emission factors at the satellite pixel level.

Jun Wang↗

Recent Developments in Quantum-Well Infrared Photodetectors

Intrinsic infrared (IR) detectors in the long wavelength range (8-20 Am) are based on an optically excited interband transition, which promotes an electron across the band gap (E(sub g)) from the valence band to the conduction band as shown. These photoelectrons can be collected efficiently, thereby producing a photocurrent in the external circuit. Since the incoming photon has to promote an electron from the valence band to the conduction band, the energy of the photon (h(sub upsilon)) must be higher than the E(sub g) of the photosensitive material. Therefore, the spectral response of the detectors can be controlled by controlling the E(sub g) of the photosensitive material. Examples for such materials are Hg(1-x), Cd(x), Te, and Pb(1-x), Sn(x), Te, in which the energy gap can be controlled by varying x. This means detection of very-long-wavelength IR radiation up to 20 microns requires small band gaps down to 62 meV. It is well known that these low band gap materials, characterized by weak bonding and low melting points, are more difficult to grow and process than large-band gap semiconductors such as GaAs. These difficulties motivate the exploration of utilizing the intersub-band transitions in multiquantum well (MQW) structures made of more refractory large-band gap semiconductors. The idea of using MQW structures to detect IR radiation can be explained by using the basic principles of quantum mechanics. The quantum well is equivalent to the well-known particle in a box problem in quantum mechanics, which can be solved by the time independent Schroudiner equation.

Gunapala, S. D.↗