Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Testing of Bulk Radiation Damage of n-in-p Silicon Sensors for Very High Radiation Environments

We are developing n{sup +}-in-p, p-bulk and n-readout, microstrip sensors, fabricated by Hamamatsu Photonics, as a non-inverting radiation hard silicon detector for the ATLAS tracker upgrade at the super-LHC (sLHC) proposed facility. The bulkradiationdamage after neutron and proton irradiations is characterized with the leakage current, charge collection and full depletion voltage. The detectors should provide acceptable signal, signal-to-noise ratio exceeding 15, after the integrated luminosity of 6000 fb{sup -1}, which is twice the sLHC integrated luminosity goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functional Polymorphisms of Base Excision Repair Genes XRCC1 and APEX1 Predict Risk of Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: To explore whether functional single nucleotide polymorphisms (SNPs) of base-excision repair genes are predictors of radiation treatment-related pneumonitis (RP), we investigated associations between functional SNPs of ADPRT, APEX1, and XRCC1 and RP development. Methods and Materials: We genotyped SNPs of ADPRT (rs1136410 [V762A]), XRCC1 (rs1799782 [R194W], rs25489 [R280H], and rs25487 [Q399R]), and APEX1 (rs1130409 [D148E]) in 165 patients with non-small cell lung cancer (NSCLC) who received definitive chemoradiation therapy. Results were assessed by both Logistic and Cox regression models for RP risk. Kaplan-Meier curves were generated for the cumulative RP probability by the genotypes. Results: We found that SNPs of XRCC1 Q399R and APEX1 D148E each had a significant effect on the development of Grade {>=}2 RP (XRCC1: AA vs. GG, adjusted hazard ratio [HR] = 0.48, 95% confidence interval [CI], 0.24-0.97; APEX1: GG vs. TT, adjusted HR = 3.61, 95% CI, 1.64-7.93) in an allele-dose response manner (Trend tests: p = 0.040 and 0.001, respectively). The number of the combined protective XRCC1 A and APEX1 T alleles (from 0 to 4) also showed a significant trend of predicting RP risk (p = 0.001). Conclusions: SNPs of the base-excision repair genes may be biomarkers for susceptibility to RP. Larger prospective studies are needed to validate our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TIME DELAY OF CASCADE RADIATION FOR TeV BLAZARS AND THE MEASUREMENT OF THE INTERGALACTIC MAGNETIC FIELD

Recent claims that the strength B{sub IGMF} of the intergalactic magnetic field (IGMF) is {approx}> 10{sup -15} G are based on upper limits to the expected cascade flux in the GeV band produced by blazar TeV photons absorbed by the extragalactic background light. This limit depends on an assumption that the mean blazar TeV flux remains constant on timescales {approx}> 2(B{sub IGMF}/10{sup -18}G){sup 2}/(E/10 GeV){sup 2} yr for an IGMF coherence length {approx}1 Mpc, where E is the measured photon energy. Restricting TeV activity of 1ES 0229+200 to {approx}3-4 years during which the source has been observed leads to a more robust lower limit of B{sub IGMF} {approx}> 10{sup -18} G, which can be larger by an order of magnitude if the intrinsic source flux above {approx}5-10 TeV from 1ES 0229+200 is strong.

79 ASTRONOMY AND ASTROPHYSICS↗

PARMA: PHITS-based Analytical Radiation Model in the Atmosphere--Verification of Its Accuracy in Estimating Cosmic Radiation Doses

Estimation of cosmic-ray spectra in the atmosphere has been an essential issue in the evaluation of the aircrew doses. We therefore developed an analytical model that can predict the terrestrial neutron, proton, He nucleus, muon, electron, positron and photon spectra at altitudes below 20 km, based on the Monte Carlo simulation results of cosmic-ray propagation in the atmosphere performed by the PHITS code. The model was designated PARMA. In order to examine the accuracy of PARMA in terms of the neutron dose estimation, we measured the neutron dose rates at the altitudes between 20 to 10400 m, using our developed dose monitor DARWIN mounted on an aircraft. Excellent agreement was observed between the measured dose rates and the corresponding data calculated by PARMA coupled with the fluence-to-dose conversion coefficients, indicating the applicability of the model to be utilized in the route-dose calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Low-Z linac targets for low-MV gold nanoparticle radiation therapy

Purpose: To investigate the potential of low-Z/low-MV (low-Z) linac targets for gold nanoparticle radiotherapy (GNPT) and to determine the microscopic dose enhancement ratio (DER) due to GNP for the alternative beamlines. In addition, to evaluate the degradation of dose enhancement arising from the increased attenuation of x rays and larger skin dose in water for the low-MV beams compared to the standard linac. Methods: Monte Carlo simulations were used to compute dose and DER for various flattening-filter-free beams (2.5, 4, 6.5 MV). Target materials were beryllium, diamond, and tungsten-copper high-Z target. Target thicknesses were selected based on 20%, 60%, 70%, and 80% of the continuous slowing down approximation electron ranges for a given target material and energy. Evaluation of the microscopic DER was carried out for 100 nm GNP including the degradation factors due to beam attenuation. Results: The greatest increase in DER compared to the standard 6.5 MV linac was for a 2.5 MV Be-target (factor of ∼2). Skin dose ranged from ∼10% (Be, 6.5 MV-80%) to ∼85% (Be, 2.5 MV-20%) depending on the target case. Attenuation of 2.5 MV beams at 22 cm was higher by ∼75% compared with the standard beam. Taking into account the attenuation at 22 cm depth, the effective dose enhancement was up to ∼60% above the DER of the high-Z target. For these cases the effective DER ranged between ∼1.6 and 6 compared with the standard linac. Conclusions: Low-Z (2.5 MV) GNPT is possible even after accounting for greater beam attenuation for deep-seated tumors (22 cm) and the increased skin dose. Further, it can lead to significant sparing of normal tissue while simultaneously escalating the dose in the tumor cells.

61 RADIATION PROTECTION AND DOSIMETRY↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

On the eigenstructure of spherical harmonic equations for radiative transport

The spherical harmonic equations for radiative transport are a linear, hyperbolic set of balance laws that describe the state of a system of particles as they advect through and collide with a material medium. For regimes in which the collisionality of the system is light to moderate, significant qualitative differences have been observed between solutions, based on whether the angular approximation used to derive the equations occurs in a subspace of even or odd degree. This difference can be traced back to the eigenstructure of the coefficient matrices in the advection operator of the hyperbolic system. In this paper, we use classical properties of the spherical harmonics to examine this structure. In particular, we show how elements in the null space of the coefficient matrices depend on the parity of the spherical harmonic approximation and we relate these results to observed differences in even and odd expansions.

Garrett, Charles K.↗