Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESEARCH FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology

Purpose: Microbeam radiation therapy (MRT) is an experimental radiotherapy technique that has shown potent antitumor effects with minimal damage to normal tissue in animal studies. This unique form of radiation is currently only produced in a few large synchrotron accelerator research facilities in the world. To promote widespread translational research on this promising treatment technology we have proposed and are in the initial development stages of a compact MRT system that is based on carbon nanotube field emission x-ray technology. We report on a Monte Carlo based feasibility study of the compact MRT system design. Methods: Monte Carlo calculations were performed using EGSnrc-based codes. The proposed small animal research MRT device design includes carbon nanotube cathodes shaped to match the corresponding MRT collimator apertures, a common reflection anode with filter, and a MRT collimator. Each collimator aperture is sized to deliver a beam width ranging from 30 to 200 {mu}m at 18.6 cm source-to-axis distance. Design parameters studied with Monte Carlo include electron energy, cathode design, anode angle, filtration, and collimator design. Calculations were performed for single and multibeam configurations. Results: Increasing the energy from 100 kVp to 160 kVp increased the photon fluence through the collimator by a factor of 1.7. Both energies produced a largely uniform fluence along the long dimension of the microbeam, with 5% decreases in intensity near the edges. The isocentric dose rate for 160 kVp was calculated to be 700 Gy/min/A in the center of a 3 cm diameter target. Scatter contributions resulting from collimator size were found to produce only small (<7%) changes in the dose rate for field widths greater than 50 {mu}m. Dose vs depth was weakly dependent on filtration material. The peak-to-valley ratio varied from 10 to 100 as the separation between adjacent microbeams varies from 150 to 1000 {mu}m. Conclusions: Monte Carlo simulations demonstrate that the proposed compact MRT system design is capable of delivering a sufficient dose rate and peak-to-valley ratio for small animal MRT studies.

60 APPLIED LIFE SCIENCES↗

PW2 Pumping: March 18 thru March 22, 2020

Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m

Distributed Strain Sensing↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Waves of Electric Charge Generated by Pulse Corona of Alternating Polarity

The project contributes to DoE Office of Science program “Opportunities in Frontier Plasma Science” by providing plasma science experiments at the Princeton Collaborative Research Facility (PCRF) – the Princeton Plasma Physics Laboratory. The research consisted of - extensive experimental/simulation studies of a pulse corona discharge pattern and dynamics performed at the University of Notre Dame; - non-intrusive measurements of electric field distribution and dynamics performed at PCRF by the method employing Electric Field-Induced Second Harmonic Generation (EFISH); and - analysis of the data acquired.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Heavy-Duty Fueling Methods and Components

Building on the successful commissioning and demonstration of NREL's heavy-duty (HD) fast flow research facility under the Innovating Hydrogen Station's Project, researchers advanced R&D activities to the next phase under a new project titled, Assessment of Heavy-Duty Fueling Methods and Components. This Cooperative Research and Development Agreement (CRADA) is led by NREL in partnership with NextEnergy, Argonne National Laboratory, and Chevron with NextEnergy representing a larger group of industry partners that includes AirLiquide, Hyundai, Nel, Nikola, Shell, and Toyota. The CRADA seeks to develop a comprehensive assessment of HD fuel cell electric vehicle fueling protocols and fueling hardware to understand the effects of fueling protocol architectures on station design, vehicle design, functional safety requirements, and the implications on the total cost of ownership (TCO) and techno economic assessment (TEA).

class 8 truck↗

Flight experience with lightweight, low-power miniaturized instrumentation systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs is reported. The data loggers, the sensors, and the hardware and software developed to complete the systems are described. How the systems were used is described and the challenges encountered to make them work are covered. Examples of raw data and derived results are shown as well. Finally, future plans for these systems are discussed. For some flight research applications where miniaturized instrumentation is a requirement, the authors conclude that commercially available data loggers and sensors are viable alternatives. In fact, the data loggers and sensors make it possible to gather research-quality data in a timely and cost-effective manner.

Hamory, Philip J.↗

Flight Experience With Lightweight, Low-Power Miniaturized Instrumentation Systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this paper is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. The paper will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. The paper also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. Finally, future plans for these systems will be discussed.

Flight Testing↗

NIST: Information Management in the AMRF

The information management strategies developed for the NIST Automated Manufacturing Research Facility (AMRF) - a prototype small batch manufacturing facility used for integration and measurement related standards research are outlined in this video. The five major manufacturing functions - design, process planning, off-line programming, shop floor control, and materials processing are explained and their applications demonstrated.

Callaghan, George↗

Flight experience with lightweight, low-power miniaturized instrumentation systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this article is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. This article will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. It also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. For some flight research applications where miniaturized instrumentation is a requirement, the authors conclude that commercially available data loggers and sensors are viable alternatives. In fact, the data loggers and sensors make it possible to gather research-quality data in a timely and cost-effective manner.

LOW POWER MINIATURIZED INSTRUM↗

Space Rose Pleases the Senses

International Flavors and Fragrances (IFF), Inc., discovered a new scent by flying a miniature rose plant aboard NASA's Space Shuttle Discovery Flight STS-95. IFF and the Wisconsin Center for Space Automation and Robotics (WCSAR) partnered to fly the rose plant in the commercial plant research facility, ASTROCULTURE(TM), for reduced-gravity environment research. IFF commercialized the space rose note, which is now a fragrance ingredient in a perfume developed by Shiseido Cosmetics (America), Ltd. In addition to providing a light crisp scent, the oil from the space rose can also serve as a flavor enhancer. ASTROCULTURE(TM) is a trademark of the Wisconsin Center for Space Automation and Robotics.

Source record↗

A new facility to study three dimensional viscous flow and rotor-stator interaction in turbines

A description of the Axial Flow Turbine Research Facility (AFTRF) being built at the Turbomachinery Laboratory of the Pennsylvania State University is presented. The purpose of the research to be performed in this facility is to obtain a better understanding of the rotor/stator interaction, three dimensional viscous flow field in nozzle and rotor blade passages, spanwise mixing and losses in these blade rows, transport of wake through rotor passage, and unsteady aerodynamics and heat transfer of rotor blade row. The experimental results will directly feed and support the analytical and the computational tool development. This large scale low speed facility is heavily instrumented with pressure and temperature probes and has provision for flow visualization and laser Doppler anemometer measurement. The facility design permits extensive use of the high frequency response instrumentation on the stationary vanes and more importantly on the rotating blades. Furthermore it facilitates detailed nozzle wake, rotor wake, and boundary layer surveys. The large size of the rig also has the advantage of operating at Reynolds numbers representative of the engine environment.

Lakshminarayana, B.↗

NSTX-U liquid metal core-edge facility (LMCE)

NSTX-U/LMCE will provide a unique and world-leading research facility to address the primary challenge to delivering economic and timely magnetic fusion energy, namely the need to develop a power and particle exhaust and first-wall system that can withstand very high edge heat fluxes, maximize energy confinement, and avoid the production of large masses of solid eroded first-wall material. The NSTX-U/LMCE facility will assess the ability of liquid metals (LMs) – especially liquid lithium – to provide a new boundary condition for magnetic fusion systems, to extend the lifetime of the plasma facing components (PFCs) and improve core plasma confinement. Such capability is needed to establish the basis for next-step fusion facilities including fusion pilot plants, and to maintain U.S. world leadership in core-edge integration research. NSTX-U/LMCE will leverage the ability to generate very high divertor perpendicular heat flux q⊥ ~ 100MW/m 2 , extensive diagnostics, and liquid-metal-applicable infrastructure of NSTX-U. NSTX-U/LMCE will provide access to a high-confinement plasma core with majority self-driven plasma current, the flexibility to test a range of liquid metal divertor concepts, access to a range of separatrix collisionalities (from high to very low), and the ability to controllably vary the first-wall temperature to vary the plasma- wall interaction physics on liquid lithium components. Further, NSTX-U/LMCE will utilize more reactor-relevant high-Z refractory-metal PFC substrates. With these capabilities the NSTX-U/LMCE facility will explore the full continuum of core-edge solutions ranging from high core radiated power, to conditions with radiative losses concentrated in the scrape-off layer (SOL), and ultimately low recycling conditions. The low collisionality SOL that may be accessible in the low recycling regime is relatively unexplored and will require a kinetic treatment of the edge, which can be addressed theoretically, and with experiments in LTX-β. Additional smaller-scale preparatory R&D facilities will be required to reduce the risk of premature technical/engineering failure of liquid metal systems implemented in NSTX-U. The NSTX-U/LMCE facility aligns very well with recommendations in the FESAC Long-Range Plan and NASEM Pilot Plant reports and the Bold Decadal Vision, will be unique in the world program throughout the next decade, and is garnering private company interest in utilizing NSTX-U/LMCE for development of LM PFCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Protection for the First Korea Heavy-ion Medical Accelerator (KHIMA) Facility - Paper 7

The number of particle therapy facilities is increasing worldwide due to the encouraging results obtained at research facilities such as the Lawrence Berkeley National Laboratory (USA), the Helmholtz Center for Heavy Ion Research GSI (Germany), and the Heavy Ion Medical Accelerator (HIMAC) in Chiba (Japan). The first hospital-based heavy-ion therapy facility is under construction in Busan, Korea, at the Korea Institute of Radiological and Medical Sciences [KIRAMS]. The project was originally designed to develop a compact superconducting cyclotron for hadron therapy able to deliver forefront beams of heavier ions, essentially carbon ions of energy, 430 MeV/u. Radiation protection issues play an important role in every stage of the project such as civil construction planning, control system design, and special technological plants. Monte Carlo transport codes are the best tools to solve these issues and the FLUKA2011 and MCNPX2.7.0 codes are used in this work. Beam loss distributions of cyclotron installations in combination with passive or active beam shaping methods have a particularly high implication on the protection layout of the facility. Methods for shielding and activation calculations are described with an emphasis on carbon ion beams. All the tools and databases require verification. Benchmarking is an instrumental process for verification. An overview of benchmarking efforts will also be given and the need for further benchmarks is discussed. (authors)

43 PARTICLE ACCELERATORS↗

Remote Handling and Maintenance in the Facility for Rare Isotope Beams

Michigan State University (MSU) in East Lansing, MI was selected by the U.S. Department of Energy (DOE) to design and establish a Facility for Rare Isotope Beams (FRIB), a cutting-edge research facility to advance the understanding of rare nuclear isotopes and the evolution of the cosmos. The research conducted at the FRIB will involve experimentation with intense beams of rare isotopes within a well-shielded target cell that will result in activation and contamination of components. The target cell is initially hands-on accessible after shutdown and a brief cool-down period. Personnel are expected to have hands-on access to the tops of shielded component modules with the activated in-beam sections suspended underneath. The modules are carefully designed to include steel shielding for protecting personnel during these hand-on operations. However, as the facility has greater levels of activation and contamination, a bridge mounted servomaniputor may be added to the cell, to perform the disconnecting of services to the component assemblies. Dexterous remote handling and exchange of the modularized activated components is completed at a shielded window workstation with a pair of master-slave manipulators. The primary components requiring exchange or maintenance are the production target, the beam wedge filter, the beam dump, and the beam focusing and bending magnets. This paper provides an overview of the FRIB Target Facility remote handling and maintenance design requirements, concepts, and techniques.

36 MATERIALS SCIENCE↗

An automated calibration laboratory for flight research instrumentation: Requirements and a proposed design approach

NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

Oneill-Rood, Nora↗

An automated calibration laboratory - Requirements and design approach

NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

O'Neil-Rood, Nora↗

Space Station gas-grain simulation facility - Microgravity particle research

The proposed Space Station gas-grain simulation facility (GGSF) and the possibilities for research in the facility are discussed. The physics of particles in microgravity is reviewed. The proposed design of the GGSF is illustrated and examined. Examples of experiments which have been suggested for the GGSF are presented, including the formation of organic haze particles in Titan's atmosphere, organic compound synthesis on surfaces of growing particles, fractal particles, planetary ring particle dynamics, aggregation of fine geological particulates in planetary atmospheres, and dipolar grain coagulation and orientation.

Carle, Glenn C.↗

The rodent research animal holding facility as a barrier to environmental contamination

The rodent Research Animal Holding Facility (RAHF), developed by NASA Ames Research Center (ARC) to separately house rodents in a Spacelab, was verified as a barrier to environmental contaminants during a 12-day biocompatibility test. Environmental contaminants considered were solid particulates, microorganisms, ammonia, and typical animal odors. The 12-day test conducted in August 1988 was designed to verify that the rodent RAHF system would adequately support and maintain animal specimens during normal system operations. Additional objectives of this test were to demonstrate that: (1) the system would capture typical particulate debris produced by the animal; (2) microorganisms would be contained; and (3) the passage of animal odors was adequately controlled. In addition, the amount of carbon dioxide exhausted by the RAHF system was to be quantified. Of primary importance during the test was the demonstration that the RAHF would contain particles greater than 150 micrometers. This was verified after analyzing collection plates placed under exhaust air ducts and rodent cages during cage maintenance operations, e.g., waste tray and feeder changeouts. Microbiological testing identified no additional organisms in the test environment that could be traced to the RAHF. Odor containment was demonstrated to be less than barely detectable. Ammonia could not be detected in the exhaust air from the RAHF system. Carbon dioxide levels were verified to be less than 0.35 percent.

Savage, P. D., Jr.↗