Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELIABLE OPERATION PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Space Shuttle Main Engine (SSME) Options for the Future Shuttle

The main engines for the Future Shuttle will focus on improved safety and operability. Performance enhancements may also be required for vehicle safety purposes to achieve more desirable abort scenarios. This paper discusses the potential improvements that will be considered for implementation into the Future Shuttle. Integrated engine and vehicle health management systems will achieve additional system-level reliability improvements over those currently in development. Advanced instrumentation for detecting leaks, analyzing component wear and degradation, and providing sophisticated operational data will be used for reliable engine control and scheduling maintenance operations. A new nozzle and main combustion chamber (MCC) will reduce failure probability by 50% and allow for higher thrust capability without requiring the entire engine to be redesigned. Turbopump improvements may range from minor component improvements to using 3rd-generation pumps built on the advanced concepts demonstrated by the Integrated Powerhead Development (IPD) program and the Space Launch Initiative (SLI) prototype engines.The main engines for the Future Shuttle will focus on improved safety and operability. Performance enhancements may also be required for vehicle safety purposes to achieve more desirable abort scenarios. This paper discusses the potential improvements that will be considered for implementation into the Future Shuttle. Integrated engine and vehicle health management systems will achieve additional system-level reliability improvements over those currently in development. Advanced instrumentation for detecting leaks, analyzing component wear and degradation, and providing sophisticated operational data will be used for reliable engine control and scheduling maintenance operations. A new nozzle and main combustion chamber (MCC) will reduce failure probability by 50% and allow for higher thrust capability without requiring the entire engine to be redesigned. Turbopump improvements may range from minor component improvements to using 3rd-generation pumps built on the advanced concepts demonstrated by the Integrated Powerhead Development (IPD) program and the Space Launch Initiative (SLI) prototype engines.

Jue, Fred↗

A Metadata-Rich File System

Despite continual improvements in the performance and reliability of large scale file systems, the management of file system metadata has changed little in the past decade. The mismatch between the size and complexity of large scale data stores and their ability to organize and query their metadata has led to a de facto standard in which raw data is stored in traditional file systems, while related, application-specific metadata is stored in relational databases. This separation of data and metadata requires considerable effort to maintain consistency and can result in complex, slow, and inflexible system operation. To address these problems, we have developed the Quasar File System (QFS), a metadata-rich file system in which files, metadata, and file relationships are all first class objects. In contrast to hierarchical file systems and relational databases, QFS defines a graph data model composed of files and their relationships. QFS includes Quasar, an XPATH-extended query language for searching the file system. Results from our QFS prototype show the effectiveness of this approach. Compared to the defacto standard, the QFS prototype shows superior ingest performance and comparable query performance on user metadata-intensive operations and superior performance on normal file metadata operations.

99 GENERAL AND MISCELLANEOUS↗

Chemical Looping Coal Gasification Sub-Pilot Unit Demonstration and Economic Assessment for IGCC applications (Final Report)

The Ohio State University (OSU) coal to syngas (CTS) technology is an advanced air separation process that can be applied for electricity production via an integrated gasification combined cycle (IGCC). The objective of the proposed project is to enable the OSU CLG technology for a commercially relevant demonstration by 2020. In order to accomplish this objective, small pilot scale demonstration of the CLG reactor system was performed. The small pilot test unit incorporates commercially scalable non-mechanical gas sealing and solids flow control components for extended operations of the integrated reactor system. A cumulative demonstration of greater than 100 hours was performed to confirm the reliability of the reactors (reducer and oxidizer) and non-mechanical devices in maintaining controlled solid circulation, gas sealing, and coal distribution in the reactor (reducer) as well as to confirm sustained syngas product performance. A comprehensive techno-economic analysis (TEA) of the OSU CLG process for IGCC application was conducted with the support of WorleyParsons, Ltd. (WP) and compared to the Department of Energy (DOE) baseline IGCC report. Using the data gained from the small pilot demonstration, a complete comprehensive techno-economic analysis (TEA) of the CLG process was conducted. The evaluation was used as basis to attract utilities and coal industries in Ohio. The project duration lasts 30 months (6 months of no cost extension). Ohio coal was used in the integrated CLG small pilot unit to convert to high hydrogen syngas. A demonstration of the integrated chemical looping reactor system at the 15 kW th scale accelerates technology commercialization in the near term. The 15 kWth demonstration addressed several major technology gaps, such as coal injection and distribution in the reducer, controllable solids circulation with the desired fuel to solids ratio, system pressure distribution for proper gas sealing, effects of contaminants and fuel/oxygen carrier residence time requirements. The fates of impurities, such as SO x and NO x was also investigated in unit demonstrations. WP conducted a comprehensive system TEA to optimize the OSU CLG process design for efficient electricity generation with greater than 90% CO 2 capture in IGCC applications. The conclusion of this project supports the further scale-up of the technology to a commercially applicable large pilot scale test unit for operation by 2020. More importantly, it benefits Ohio as it provides an economically competitive mean for power generation with carbon capture. Given the rise of natural gas usage and strict environmental regulations, the use of Ohio coal is expected to decrease and thus impact the coal economy in Ohio. The conclusion of this project provided way for Ohio coal to compete in the future and secure jobs in the energy sector.

01 COAL, LIGNITE, AND PEAT↗

Transformational Solid Oxide Fuel Cell (SOFC) Technology

This project was conducted under the Co-operative Agreement No. DE-FE0027584 with the US Department Energy to developed advanced Solid Oxide Fuel Cell (SOFC) Technologies. The overall objective of this project was to advance SOFC technology at the cell and stack level to enhance cell robustness and durability, increase performance, and reduce balance-of-plant (BOP) requirements. By reducing system complexity combined with the increases in power density and efficiency, the ultimate goal of the project was to increased reliability and to reduce capital and operating costs of installed systems. The project was focused on pathways that will reduce the cost of the SOFC cell and stack, including the following areas: Robust, redox tolerant cell technology Lower cost cell manufacturing through advances in cell design, which will reduce the amount of material, energy and time used in the fabrication of SOFCs High performance, low temperature electrolyte based on improvement of established materials Innovative SOFC stack architecture which truly integrates Balance of Plant functionality into the stack level design Thermal management of the fuel cell stack for increased durability and expanded window of operation Novel stack design amenable for use in sub-MW to multi-MW-scale power plants and having low replacement cost The incorporation of balance-of-plant (BOP) equipment into the stack platform increased the economic viability of smaller scale systems. The project objectives were met by a multi-prong approach, including new cell design complemented with modifications to existing cell technology, as well as a new stack design incorporating components typically included in the BOP, such as heat exchangers, oxidizer, fuel reformers, and recycle systems. The project culminated with demonstration of a stack test validating the viability of the cell and stack improvements. A cost model was also developed to estimate costs for the advanced stack technology at high volume manufacturing levels. The net outcome of the project is SOFC cell and stack technology with costs significantly below current DOE targets without compromising and, in some cases, improving on the performance and degradation rate demonstrated with the current state-of-the-art stack design. The results of this project advanced the reliability, robustness, and endurance of low-cost SOFC technology that ultimately are ready to be deployed in coal power systems with greater than 60 percent efficiency (based on higher heating value of fuel) and the capability for ≥97% CO 2 capture at a cost-of-electricity that is approximately 40 percent below presently available Integrated Gasification Combined Cycle systems.

03 NATURAL GAS↗

Future Vision for Instrumentation, Information and Control Modernization

A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II&C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can address provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns.

99 GENERAL AND MISCELLANEOUS↗

Loss Analysis and Mapping of a SiC MOSFET Based Segmented Two-Level Three-Phase Inverter for EV Traction Systems

Emerging wide-bandgap based power semiconductor devices are gaining popularity in power electronic systems for automotive applications with the aim of increased power density, reduced weight and increased efficiency. In this work, loss analysis and mapping of a segmented two-level inverter based on SiC MOSFETs are presented in order to identify the challenges in design of power electronics and electric machines for EV applications. The paper starts with description of the EV traction system that is chosen as the study case, followed by segmented inverter topology, power device selection and sizing. The theoretical switching, conduction and dead-time conduction loss analysis for the SiC MOSFETs in the segmented two-level inverter topology are presented under any given operating condition. The analysis is followed by loss mapping of the motor, inverter and overall EV traction system. The loss maps of the inverter and the motor show that each component has different thermal loading trends under given torque-speed characteristics. Therefore, various operating conditions have to be considered for the design of traction system components to ensure reliability and high performance, which are critical requirements for EV systems.

Gurpinar, Emre↗

Analysis of System and Interoperability Impact from Securing Communications for Distributed Energy Resources

As the power grid incorporates increasing amounts of distributed energy resources (DER) that provide new generation sources, new opportunities are created for improving operation of the grid while large challenges also arise for preserving grid reliability and security. To improve grid performance, DERs can be utilized to provide important support functionality, such as supporting frequency and voltage levels, especially if they are assisted by communication schemes as part of an advanced distribution management system (ADMS). Unfortunately, such connectivity and grid support functionality also creates additional cyber security risk with the potential for degradation of grid services, especially under conditions with high amounts of distributed generation. This paper will first discuss the communications needed by DERs to support system and interoperability objectives, as well as the security requirements and impact of securing these communications. Some common security mechanisms are discussed in relation to DERs, and a simulated 15-bus model of a distribution feeder is used to demonstrate aspects of the DER communications and impact to grid performance. These results help to advance understanding of the benefits, requirements, and mechanisms for securely implementing DER communications while ensuring that grid reliability is maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

( Invited ) Ruggedness of SiC and GaN Power Transistors in Switching Based Tests

Currently, a spectrum of reliability tests are being performed by both device manufacturers and end users. Many of these qualification tests are operated within the device safe-operating-area (SOA), however, the devices often undergo dynamic events in many converter applications that can exceed the SOA boundaries. This paper presents our recent work on quantifying the out-of-SOA robustness of GaN power high-electron-mobility transistors (HEMTs) and SiC power MOSFETs by switching based tests. The unclamped inductive switching stresses are applied to p-gate GaN HEMTs to evaluate their surge-energy and overvoltage robustness. The continuous, hard-switching, turn-off stresses are applied to SiC MOSFETs to evaluate their overvoltage switching robustness. As a result, both experiments demonstrate the robustness of SiC and GaN devices under out-of-SOA switching events, and the physics of degradation and failure are understood.

42 ENGINEERING↗

Understanding Microstructure Variability in Vapor-Deposited Energetic Materials by Using Phase-Field Methods

Critical components, such as detonators, in Sandia's stockpile contain heterogeneous materials whose performance and reliability depend on accurate, predictive models of coupled, complex phenomena to predict their synthesis, processing, and operation. Ongoing research in energetic materials has shown that microstructural properties, such as density, pore-size, morphology, and specific surface area are correlated to their initiation threshold and detonation behavior. However, experiments to study these specific characteristics of energetic materials are challenging and time consuming. Therefore, in this work, we turn to mesoscale modeling methods that may be capable of reproducing some observed phenomena to refine and predict outcomes beforehand. Even so, we have no physics-based modeling capability to predict how the microstructure of an energetic material will evolve over near- and long-term time scales. Thus, the goal of this work is to (i) identify any knowledge gaps in how the underlying microstructure forms and evolves during the synthesis process, and (ii) develop and test a mesoscale phase-field model for vapor deposition to capture critical mechanisms of microstructure formation, evolution, and variability in vapor-deposited energetic materials, such as processing conditions, material properties, and substrate interactions. Based on this work, the phase-field method is shown to be a valuable tool for developing the necessary models containing coupled, complex phenomena to investigate and understand the synthesis and processing of energetic materials.

36 MATERIALS SCIENCE↗

Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept

This report summarizes the work performed for the U. S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) under Cooperative Agreement DE-FE0026211 entitled “Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept”. The overall objective of this project was to develop and evaluate a solid oxide fuel cell (SOFC) stack configuration based on a novel prime-surface interconnect design for a broad range of power generation applications. The prime-surface is a one-piece metallic interconnect that incorporates both fuel and oxidant flow fields with peaks on one side of the interconnect serving as flow channels (valleys) on the other side. (One example is the egg-carton shaped interconnect design.) This stack technology has several attractive features including reduced stack weight and volume, decreased performance losses in stacking, improved sealing, versatility in incorporation of different types of cell construction (thin-film cells or sintered cells) and flexibility in gas flow configuration (cross-flow, co-flow or counter-flow). These features lead to lower cost, better performance, and enhanced reliability for the stack. The R&D work of this project focused on demonstrating fabrication, operability and cost effectiveness of the stack design and was conducted by University of California, San Diego (UCSD) in conjunction with OxEon Energy (OxEon). The key technical activities of this project involved prime-surface interconnect design and fabrication development; supported thin-film cell structure development; stack development; stack operation demonstration; and stack cost assessment. The results of these activities are summarized in this report.

30 DIRECT ENERGY CONVERSION↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond

If power systems transition to integrate higher amounts of variable renewable energy sources, storage technologies, and distributed energy resources (DERs), new risk management frameworks are necessary to ensure cost-effective and reliable power system operations. Projects funded by the Advanced Research Projects Agency-Energy (ARPA-E) Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program aim to contribute new risk management frameworks by developing methods to quantify and manage risk at grid asset and system levels. The National Renewable Energy Laboratory (NREL) led a PERFORM project in collaboration with the Johns Hopkins University, the Electric Power Research Institute (EPRI), kWh Analytics, Packetized Energy, and Imperial Consultants (ICON). The project addressed two challenges related to risk management in electricity markets: managing net load imbalances and flexibility from DERs. This final technical report presents a list of project accomplishments, activities, and outputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review: Fuel Volatility Standards and Spark-Ignition Vehicle Driveability

We've put spark-ignition engine fuel standards in place in order to ensure acceptable hot and cold weather driveability (HWD and CWD). Vehicle manufacturers and fuel suppliers have developed systems that meet our driveability requirements so effectively that drivers overwhelmingly find that their vehicles reliably start up and operate smoothly and consistently throughout the year. For HWD, fuels that are too volatile perform more poorly than those that are less volatile. Vapor lock is the apparent cause of poor HWD, but there is conflicting evidence in the literature as to where in the fuel system it occurs. Most studies have found a correlation between degraded driveability and higher dry vapor pressure equivalent or lower TV/L = 20, and less consistently with a minimum T50. For CWD, fuels with inadequate volatility can cause difficulty in starting and rough operation during engine warmup. The Driveability Index (DI)-a function of T10, T50, and T90-is well correlated with CWD in hydrocarbon fuels. For ethanol-containing fuels, a correction factor to the DI equation improves the correlation with CWD, although the best value for that factor has still not been determined. Ethanol increases the heat of vaporization. But, this is likely insignificant for E15 and lower concentration fuels. The impact of ethanol on driveability is likely due to its direct effect on vapor pressure at cold temperatures. For E51-E83 or flex-fuel blends, ASTM sets a minimum vapor pressure; however, published data suggest that a correction for the amount of ethanol in the fuel is needed to accurately predict CWD, possibly because ethanol has a higher lower-flammability limit.

30 DIRECT ENERGY CONVERSION↗

Assess program: Interactive data management systems for airborne research

Two data systems were developed for use in airborne research. Both have distributed intelligence and are programmed for interactive support among computers and with human operators. The C-141 system (ADAMS) performs flight planning and telescope control functions in addition to its primary role of data acquisition; the CV-990 system (ADDAS) performs data management functions in support of many research experiments operating concurrently. Each system is arranged for maximum reliability in the first priority function, precision data acquisition.

Munoz, R. M.↗

Revised adage graphics computer system

Bootstrap loader and mode-control options for Adage Graphics Computer System Significantly simplify operations procedures. Normal load and control functions are performed quickly and easily from control console. Operating characteristics of revised system include greatly increased speed, convenience, and reliability.

Tulppo, J. S.↗

Ordering actions for visibility

The notion of 'atomic actions' has been considered in recent work on data integrity and reliability. It has been found that the standard database operations of 'read' and 'write' carry with them severe performance limitations. For this reason, systems are now being designed in which actions operate on 'objects' through operations with more-or-less arbitrary semantics. An object (i.e., an instance of an abstract data type) comprises data, a set of operations (procedures) to manipulate the data, and a set of invariants. An 'action' is a unit of work. It appears to be primitive to its surrounding environment, and 'atomic' to other actions. Attention is given to the conventional model of nested actions, ordering requirements, the maximum possible visibility (full visibility) for items which must be controlled by ordering constraints, item management paradigms, and requirements for blocking mechanisms which provide the required visibility.

Mckendry, M. S.↗

Lunar electric power systems utilizing the SP-100 reactor coupled to dynamic conversion systems

An integration study was performed by coupling an SP-100 reactor to either a Brayton or Stirling power conversion subsystem. The application was for a surface power system to supply power requirements to a lunar base. A power level of 550 kWe was selected based on the NASA Space Exploration Initiative 90-day study. Reliability studies were initially performed to determine optimum power-conversion redundancy. This study resulted in selecting three operating engines and one standby unit. Integratiaon-design studies indicated that either the Brayton or Stirling power conversion subsystem could be integrated with the SP-100 reactor. The Stirling system had an integration advantage because of smaller piping size and fewer components. The Stirling engine, however, is more complex and heavier than the Brayton rotating unit, which tends to offset the Stirling integration advantage. From a performance consideration, the Brayton had a 9-percent mass advantage and the Stirling a 50-percent radiator-area advantage.

Harty, Richard B.↗

Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. An engineering unit, the ASRG engineering unit (EU), was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently under extended operation test at the NASA Glenn Research Center (GRC) to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for the ASRG EU. This paper summarizes details of the test facility design, including the mechanical mounting, heat-rejection system, argon system, control systems, and maintenance. The effort proceeded from requirements definition through design, analysis, build, and test. Initial testing and facility performance results are discussed.

Lewandowski, Edward J.↗

DC to DC Converter Testing for Space Applications: Use of EMI Filters and Thermal Range of Operation

Several tests were performed on Interpoint and International Rectifier (IR) direct current (DC) to DC converters to evaluate potential performance and reliability issues in space use of DC to DC converters and to determine if the use of electromagnetic interference (EMI) filters mitigates concerns observed during previous tests. Test findings reported here include those done up until September - October 2008. Tests performed include efficiency, regulation, cross-regulation, power consumption with inhibit on, load transient response, synchronization, and turn-on tests. Some of the test results presented here span the thermal range -55 C to 125 C. Lower range was extended to -120 C in some tested converters. Determination of failure root cause in DC/DC converters that failed at thermal extremes is also included.

Leon, Rosa↗