Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REGENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Hydroelectric Power and Hydrogen Production Integration

Hydropower-based hydrogen production could introduce opportunities for new revenue streams for hydropower plants, including from energy storage and regeneration as well as from sale of the hydrogen product to external markets. Hydrogen-based energy storage and regeneration could also help support Idaho Power’s decarbonization goals by decreasing dependence on fossil-based peaking power plants. Additionally, integration of hydrogen production with hydropower generation could help address the issue of low dissolved oxygen river water conditions that commonly accompany hydropower plant operations by utilizing the oxygen byproduct from an electrolytic hydrogen production process as a resource for mitigation of low dissolved oxygen water conditions. Comprehensive techno-economic analysis of the hybrid hydroelectric and hydrogen energy storage system has revealed critical insights into the pathways and considerations for optimizing the economic value and environmental benefits of such systems. Among the three identified pathways of natural gas blending, regeneration, and direct sale of hydrogen, the direct sale of hydrogen emerges as the most profitable, particularly given the current pricing dynamics of hydrogen and electricity. However, as we anticipate a future grid characterized by higher renewable energy penetration, the landscape may evolve, featuring lower average electricity prices, heightened fluctuations, and more significant seasonal variations. Consequently, the attractiveness of electricity regeneration through hydrogen and the benefits of long-duration hydrogen storage are expected to increase substantially in such a dynamic energy scenario. The careful selection of component sizes within the hybrid system proves to be paramount for ensuring cost-effectiveness. Notably, the size of the hydrogen market has emerged as a critical determinant for the optimal size of the electrolyzer. Hydrogen storage should be sized to meet energy shifting requirements. The appropriate size of the fuel cell/microturbine generator hinges on the shape of electricity prices and the available revenue streams derived from participating in grid services. Striking the right balance among these components is essential for maximizing the overall efficiency and profitability of the hydrogen facility. Furthermore, the by-product of electrolysis, namely oxygen, introduces an additional dimension to the system's functionality. The oxygen generated can be effectively utilized for dissolved oxygen (DO) mitigation, particularly with larger electrolyzer sizes capable of satisfying the complete oxygen demand for this purpose. While the economic benefits derived from saved oxygen purchase costs may be relatively modest compared to other revenue streams, the environmental advantages of repurposing oxygen for DO mitigation could help Idaho Power meet their environmental obligations. In addition to the identified factors shaping the viability of hybrid hydrogen production and hydroelectric generation, it is noteworthy that the integration of hydrogen energy storage offers a unique advantage during unusually wet years. In such periods of increased water inflow, the hydrogen storage capacity serves as a valuable supplement to the reservoir. By utilizing hydrogen energy storage as a complementary reservoir, the system gains flexibility in reservoir management when dealing with fluctuations in water availability.

08 HYDROGEN↗

Electromagnetic Energy-Assisted Thermal Conversion of Fossil-Based Hydrocarbons to Low-Cost Hydrogen

The goal of this project was to develop and optimize catalysts for methane decomposition, particularly focusing on regeneration via an electromagnetic energy-assisted mechanism, to produce hydrogen more cost-effectively compared to electrolysis routes. To achieve this goal, the project pursued several key objectives. The project began with the preparation and testing of various catalysts. A nickel-silica based catalyst was identified as the most promising material for the pyrolysis of methane into carbon and hydrogen. Kinetic parameters for methane decomposition were determined, aiding in computational modeling efforts. Structured catalysts were investigated, highlighting the need for frequent cleaning or regeneration to maintain performance, with methane conversion rates exceeding 70% in tube furnace tests. Computational fluid dynamics modeling was employed to optimize reactor designs and electrode angles, leading the project team to propose a multi-compartment thermal conversion system for larger setups. This modeling work was important in understanding reaction characteristics, carbon deposition rates, and temperature profiles under various conditions. A bench-scale reactor system was assembled to evaluate catalyst regeneration using electromagnetic energy-assisted mechanisms. Experiments demonstrated the potential for carbon removal, though further optimization is needed. The carbon produced from the methane conversion process was evaluated for potential use in lithium-ion battery electrodes. The carbon exhibited properties similar to commercially available high-purity multi-walled carbon nanotubes and nanofibers, with a carbon content greater than 95%. Coin cell batteries assembled with this carbon showed that lower replacement levels (10% to 33%) outperformed the control group, improving specific capacity density and stability. However, higher replacement levels (100%) demonstrated poorer performance, suggesting that excessive carbon substitution negatively impacts battery performance. These findings indicate the potential marketability of the produced carbon as a component in lithium-ion batteries, though further testing is necessary to confirm long-term advantages and disadvantages associated with the use of the carbon product. These results however justified further technoeconomic assessments to determine if the process can provide low-cost hydrogen. The economic feasibility and technical performance of methane decomposition for hydrogen production were assessed, focusing on three plant configurations: 100E (electrically heated), 100C (combustion heated using produced hydrogen), and PE-Hybrid (a combination of pyrolysis (indicating decomposition) and electrolysis). The Levelized Cost of Hydrogen (LCOH) for the pyrolysis configurations was found to be approximately 25% lower than that of electrolysis. The 100E configuration had the lowest LCOH at $\$$3.12/kg. Including carbon product sales significantly improved the economics, with the 100C configuration achieving a negative LCOH of -$\$$0.35/kg. The PE-Hybrid configuration was not economically advantageous compared to pure pyrolysis plants due to its complexity and additional equipment requirements. Ultimately, methane pyrolysis presents a viable method for near carbon dioxide-free hydrogen production, with significant economic advantages over electrolysis, especially when considering the sale of carbon byproducts. The 100E and 100C configurations showed the most promise, with the choice between them ultimately depending on the prices of power and natural gas. In conclusion, this technology has the potential to lower hydrogen production costs by leveraging the methane decomposition process with the sale of valuable carbon byproducts. By optimizing catalyst performance and integrating electromagnetic energy-assisted regeneration, the process can achieve higher efficiency and economic viability, making it a competitive alternative to traditional hydrogen production methods.

08 HYDROGEN↗

Feasibility of using nuclear microreactor process heat for bioconversion and agricultural processes

Introduction There is a global goal to reduce greenhouse gas emissions by 43% by 2023. Nuclear microreactors, a subset of small modular reactors, offer a potential solution due to their compact size, transportability, and carbon-neutral power generation capabilities. Methods This study explores the feasibility of using heat from nuclear microreactors for bioconversion and agricultural processes, including transforming biomass into energy carriers and products such as syngas, bio-oil, and pasteurized milk. Operating requirements for gasification, pyrolysis, hydrothermal carbonization, hydrothermal liquefaction, hydrothermal gasification, ethanol production, anaerobic digestion, and pasteurization were obtained through a literature review. A Brayton cycle model based on the eVinci TM microreactor was developed to assess the feasibility of powering these processes using nuclear microreactor heat. Results and Discussion Exergetic efficiency values for high-temperature processes ranged from 72% to 100%, whereas lower-temperature processes ranged from 2% to 53%. These efficiencies depend on the available source temperature for each microreactor design. There were trade-offs between producing net power and using process heat, particularly for high-temperature processes. Three heat exchanger locations were considered: before the turbine (600 ℃ ), between the turbine and regenerator (370 ℃ ), and after the regenerator (192 ℃ ). High-temperature processes like gasification require temperatures too high for feasibility. Middle temperature processes are better suited to a heat exchanger between the turbine and regenerator, while also operable before the turbine. Lower-temperature processes like pasteurization and anaerobic digestion can use waste heat after the regenerator and do not impact power production. These findings are valuable for optimizing nuclear microreactor heat use and aligning with global climate initiatives.

09 BIOMASS FUELS↗

Regenerative CO2 removal for PLSS application

Various concepts for the design of the nonelectrochemical absorber were defined and evaluated. A preliminary design based on the use of hollow fiber membranes was developed. Small scale bench testing demonstrated the carbon dioxide removal capability and provided design data for scale-up to the one person level. A full scale conceptual design of the absorbent regeneration hardware using six electrochemical cells was also completed. The design was supported by single cell testing and showed that a full scale regeneration system, operating continuously over 24 hours, can regenerate the absorbent from one extravehicular activity mission. The single cell regeneration hardware was operated for over 800 hours.

Heppner, D. B.↗

The theory of an active magnetic regenerative refrigerator

The adiabatic temperature change with field which is limited to about 2 K/Tesla for ferromagnets near their Curie temperatures by the change of magnetization with temperature and the lattice heat capacity is discussed. Practical magnetic refrigerators operate on a regenerative cycle such as the Brayton cycle. This cycle can be executed through the use of an active magnetic regenerator, i.e., a regenerator composed of magnetic material that is cycled in an out of a magnetic field with appropriate fluid flows. The theory of these devices is predicted by solving the partial differential equations that describe fluid and the magnetic solid. The active magnetic regenerator is described along with the method of calculation. Temperature profiles for a normal regenerator and a magnetic regenerative refrigerator are shown.

Barclay, J. A.↗

Effects of leakage through clearance seals on the performance of a 10 K Stirling-cycle refrigerator

The use of clearance seals is essential to achieve long life, wear free operation of Stirling cycle cryogenic refrigerators. The effect of leakage through clearance seals on the performance of such a refrigerator operating at temperatures ranging from 20 K down to 10 K was determined. The ability of a Stirling cycle refrigerator to achieve 10 K with clearance seals was successfully demonstrated. It is indicated that the leakage flow undergoes gap regeneration before reaching the cold expansion volume. A simple model of gap regeneration was used to estimate the regeneration loss due to the leakage flow. This regeneration process minimizes the loss in refrigerator performance caused by the clearance seal leakage. It is found that clearance seals remain effective down to a refrigeration temperature of 10 K.

Keung, C. S.↗

Advanced Gas Turbine (AGT) technology report

Engine testing, ceramic component fabrication and evaluation, component performance rig testing, and producibility experiments at Pontiac comprised AGT 100 activities of this period, January to December 1984. Two experimental engines were available and allowed the evaluation of eight experimental assemblies. Operating time accumulated was 115 hr of burning and 156 hr total. Total cumulative engine operating time is now 225 hr. Build number 11 and 12 of engine S/N 1 totaled 28 burning hours and constituted a single assembly of the engine core--the compressor, both turbines, and the gearbox. Build number 11 of engine S/N 1 included a 1:07 hr continuous test at 100% gasifier speed (86,000 rpm). Build number 8 of engine S/N 2 was the first engine test with a ceramic turbine rotor. A mechanical loss test of an engine assembly revealed the actual losses to be near the original design allowance. Component development activity included rig testing of the compressor, combustor, and regenerator. Compressor testing was initiated on a rig modified to control the transfer of heat between flow path, lubricating oil, and structure. Results show successful thermal decoupling of the rig and lubricating/cooling oil. Rig evaluation of a reduced-friction compressor was initiated. Combustor testing covered qualification of ceramic parts for engine use, mapping of operating range limits, and evaluation of a relocated igniter plug. Several seal refinements were tested on the hot regenerator rig. An alternate regenerator disk, extruded MAS, was examined and found to be currently inadequate for the AGT 100 application. Also, a new technique for measuring leakage was explored on the regenerator rig. Ceramic component activity has focused on the development of state-of-the-art material strength characteristics in full-scale hardware. Injection-molded sintered alpha-SiC rotors were produced at Carborundum in an extensive process and tool optimization study.

Source record↗

Stirling Engine With Radial Flow Heat Exchangers

Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

Vitale, N.↗

Comparative Transduction Mechanisms of Vestibular Otolith Hair Cells

Hair cells in the bullfrog vestibular otolith organs regenerate following aminoglycoside ototoxicity. Hair cells in these organs are differentially sensitive to gentamicin, with saccular hair cells and hair cells in the utricular striola being damaged at lower gentamicin concentrations than hair cells in the utricular extrastriola. Regenerating hair cells in these organs have short hair bundles and can be classified into a number of phenotypes using the same morphological criteria used to identify their mature counterparts. Our studies suggest that some supporting cells can convert, or transdifferentiate,into hair cells without an intervening cell division. By stimulating these processes in humans, clinicians may be able to alleviate human deafness and peripheral vestibular disorders by regenerating and replacing lost hair cells. In vivo and in vitro studies were done on cell proliferation and hair cell regeneration.

Baird, Richard A.↗

Kinetics and Mechanism of the Reaction of Hydoxyl Radicals with Acetonitrile under Atmospheric Conditions

The pulsed laser photolysis-pulsed laser induced fluorescence technique has been employed to determine absolute rate coefficients for the reaction OH + CH3CN (1) and its isotopic variants, OH + CD3CN (2), OD + CH3CN (3), and OD + CD3CN (4). Reactions 1 and 2 were studied as a function of pressure and temperature in N2, N2/O2, and He buffer gases. In the absence of O2 all four reactions displayed well-behaved kinetics with exponential OH decays and pseudo-first rate constants which were proportional to substrate concentration. Data obtained in N2 over the range 50-700 Torr at 298 K are consistent with k(sub 1), showing a small pressure dependence. The Arrhenius expression obtained by averaging data at all pressures in k(sub 1)(T) = (1.1(sup +0.5)/(sub -0.3)) x 10(exp -12) exp[(-1130 +/- 90)/T] cu cm /(molecule s). The kinetics of reaction 2 are found to be pressure dependent with k(sub 2) (298 K) increasing from (1.21 +/- 0.12) x 10(exp -14) to (2.16 +/- 0.11) x 10(exp -14) cm(exp 3)/ (molecule s) over the pressure range 50-700 Torr of N2 at 298 K. Data at pressures greater than 600 Torr give k(sub 2)(T) = (9.4((sup +13.4)(sub -5.0))) x 10(exp -13) exp[(-1180 +/- 250)/T] cu cm/(molecule s). The rates of reactions 3 and 4 are found to be independent of pressure over the range 50-700 Torr of N2 with 298 K rate coefficient given by k(sub 3) =(3.18 +/- 0.40) x 10(exp -14) cu cm/(molecule s) and k(sub 4) = (2.25 +/-0.28) x 10(exp -14) cu cm/(molecule s). In the presence of O2 each reaction shows complex (non-pseudo-first-order) kinetic behavior and/or an apparent decrease in the observed rate constant with increasing [O2], indicating the presence of significant OH or OD regeneration. Observation of regeneration of OH in (2) and OD in (3) is indicative of a reaction channel which proceeds via addition followed by reaction of the adduct, or one of its decomposition products, with O2. The observed OH and OD decay profiles have been modeled by using a simple mechanistic scheme to extract kinetic information about the adduct reations with O2 and branching ratios for OH regeneration. A plausible mechanism for OH regeneration in (2) involves OH addition to the nitrogen atom followed by O2 addition to the cyano carbon atom, isomeriazation and decomposition to D2CO + DOCN + OH. Our results suggest that the OH + CH3CN reaction occurs via a complex mechanism involving both bimolecular and termolecular pathways, analogous to the mechanisms for the the important atmospheric reactions of OH with CO and HNO3.

Hynes, A. J.↗

The use of rice hulls for sustainable control of NOx emissions in deep space missions

The use of the activated carbon produced from rice hulls to control NOx emissions for future deep space missions has been demonstrated. The optimal carbonization temperature range was found to be between 600 and 750 degrees C. A burnoff of 61.8% was found at 700 degrees C in pyrolysis and 750 degrees C in activation. The BET surface area of the activated carbon from rice hulls was determined to be 172 m2/g when prepared at 700 degrees C. The presence of oxygen in flue gas is essential for effective adsorption of NO by activated carbon. On the contrary, water vapor inhibits the adsorption efficiency of NO. Consequently, water vapor in flue gas should be removed by drying agents before adsorption to ensure high NO adsorption efficiency. All of the NO in the flue gas was removed for more than 1.5 h when 10% oxygen was present and the ratio of the carbon weight to the flue gas flow rate (W/F) was 15.4 g min/L. Reduction of the adsorbed NO to form N2 could be effectively accomplished under anaerobic conditions at 550 degrees C. The adsorption capacity of NO on the activated carbon was found to be 5.02 mg of NO/g of carbon. The loss of carbon mass was determined to be about 0.16% of the activated carbon per cycle of regeneration if the regeneration occurred when the NO in the flue gas after the carbon bed reached 4.8 ppm, the space maximum allowable concentration. The reduction of the adsorbed NO also regenerated the activated carbon, and the regenerated activated carbon exhibited an improved NO adsorption efficiency.

NASA Program Advanced Human Support Technology↗

Microlith Based Sorber for Removal of Environmental Contaminants

The development of energy efficient, lightweight sorption systems for removal of environmental contaminants in space flight applications is an area of continuing interest to NASA. The current CO2 removal system on the International Space Station employs two pellet bed canisters of 5A molecular sieve that alternate between regeneration and sorption. A separate disposable charcoal bed removes trace contaminants. An alternative technology has been demonstrated using a sorption bed consisting of metal meshes coated with a sorbent, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI); thesemeshes have the potential for direct electrical heating for this application. This allows the bed to be regenerable via resistive heating and offers the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. The capability of removing both CO2 and trace contaminants within the same bed has also been demonstrated. Thus, the need for a separate trace contaminant unit is eliminated resulting in an opportunity for significant weight savings. Unlike the charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration. This paper describes the design and performance of a prototype sorber device for simultaneous CO2 and trace contarninant removal and its attendant weight and energy savings.

Roychoudhury, S.↗

Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

Roychoudhury, S.↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger with Bypass Setpoint Temperature Control

Spacecraft radiators are sized for their maximum heat load in their warmest thermal environment, but must operate at reduced heat loads and in colder environments. For systems where the radiator environment can be colder than the working fluid freezing temperature, radiator freezing becomes an issue. Radiator freezing has not been a major issue for the Space Shuttle and the International Space Station (ISS) active thermal control systems (ATCSs) because they operate in environments that are warm relative to the freezing point of their external coolants (Freon-21 and ammonia, respectively). For a vehicle that lands at the Lunar South Pole, the design thermal environment is 215K, but the radiator working fluid must also be kept from freezing during the 0 K sink of transit. A radiator bypass flow control design such as those used on the Space Shuttle and ISS requires more than 30% of the design heat load to avoid radiator freezing during transit - even with a very low freezing point working fluid. By changing the traditional ATCS architecture to include a regenerating heat exchanger inboard of the radiator and by using a regenerator bypass flow control valve to maintain system setpoint, the required minimum heat load can be reduced by more than half. This gives the spacecraft much more flexibility in design and operation. The present work describes the regenerator bypass ATCS setpoint control methodology. It includes analytical results comparing the performance of this system to the traditional radiator bypass system. Finally, a summary of the advantages of the regenerator bypass system are presented.

Ungar, Eugene K.↗

Advanced CO2 Removal and Reduction System

An advanced system for removing CO2 and H2O from cabin air, reducing the CO2, and returning the resulting O2 to the air is less massive than is a prior system that includes two assemblies . one for removal and one for reduction. Also, in this system, unlike in the prior system, there is no need to compress and temporarily store CO2. In this present system, removal and reduction take place within a single assembly, wherein removal is effected by use of an alkali sorbent and reduction is effected using a supply of H2 and Ru catalyst, by means of the Sabatier reaction, which is CO2 + 4H2 CH4 + O2. The assembly contains two fixed-bed reactors operating in alternation: At first, air is blown through the first bed, which absorbs CO2 and H2O. Once the first bed is saturated with CO2 and H2O, the flow of air is diverted through the second bed and the first bed is regenerated by supplying it with H2 for the Sabatier reaction. Initially, the H2 is heated to provide heat for the regeneration reaction, which is endothermic. In the later stages of regeneration, the Sabatier reaction, which is exothermic, supplies the heat for regeneration.

Alptekin, Gokhan↗

Reversible Ammonia Sorption for the Primary Life Support System (PLSS)

Results are presented on the development of regenerable trace-contaminant (TC) sorbent for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). Since ammonia is the most important TC to be captured, data presented in this paper are limited to ammonia sorption, with results relevant to other TCs to be reported at a later time. The currently available TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal. The sorbent is non-regenerable, and its use is associated with appreciable pressure drop, i.e. power consumption. The objective of this work is to demonstrate the feasibility of using vacuum-regenerable sorbents for PLSS application. In this study, several carbon sorbent monoliths were fabricated and tested. Multiple adsorption/vacuum-regeneration cycles were demonstrated at room temperature, as well as carbon surface conditioning that enhances ammonia sorption without impairing sorbent regeneration. Depending on sorbent monolith geometry, the reduction in pressure drop with respect to granular sorbent was found to be between 50% and two orders of magnitude. Resistive heating of the carbon sorbent monolith was demonstrated by applying voltage to the opposite ends of the monolith.

Wojtowicz, Marek A.↗

Self-Cleaning Particulate Prefilter Media

A long-term space mission requires efficient air revitalization performance to sustain the crew. Prefilter and particulate air filter media are susceptible to rapid fouling that adversely affects their performance and can lead to catastrophic failure of the air revitalization system, which may result in mission failure. For a long-term voyage, it is impractical to carry replacement particulate prefilter and filter modules due to the usual limitations in size, volume, and weight. The only solution to this problem is to reagentlessly regenerate prefilter and filter media in place. A method was developed to modify the particulate prefilter media to allow them to regenerate reagentlessly, and in place, by the application of modest thermocycled transverse or reversed airflows. The innovation may allow NASA to close the breathing air loop more efficiently, thereby sustaining the vision for manned space exploration missions of the future. A novel, self-cleaning coatings technology was developed for air filter media surfaces that allows reagentless in-place regeneration of the surface. The technology grafts thermoresponsive and nonspecific adhesion minimizing polymer nanolayer brush coatings from the prefilter media. These polymer nanolayer brush architectures can be triggered to contract and expand to generate a "pushing-off" force by the simple application of modestly thermocycled (i.e. cycling from ambient cabin temperature to 40 C) air streams. The nonspecific adhesion-minimizing properties of the coatings do not allow the particulate foulants to adhere strongly to the filter media, and thermocycled air streams applied to the media allow easy detachment and in-place regeneration of the media with minimal impact in system downtime or astronaut involvement in overseeing the process.

Weber, Olivia↗

Alpha-Stream Convertor

A thermo-acoustic engine and/or cooler is provided and includes an elongated tubular body, multiple regenerators disposed within the body, multiple heat exchangers disposed within the body, where at least one heat exchanger is disposed adjacent to each of the multiple regenerators, multiple transducers axially disposed at each end of the body, and an acoustic wave source generating acoustic waves. At least one of the acoustic waves is amplified by one of the regenerators and at least another acoustic wave is amplified by a second one of regenerators.

Dyson, Jr., Rodger William↗