Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The Zero-Degree Detector System

We will report on a detector system used for accelerator measurement of nuclear fragmentation cross sections. This system consists of two detector planes, each carrying a ring of 8 detectors. Each detector has 64 pads. These two detector planes are arranged facing each other so that the matching detector pads on each plane form a two element charged particle telescope. Each of these telescopes is capable of determining the elemental identity of nuclear fragments passing through it. The system is used to measure light fragment production in the presence of heavier fragments. We will present a detailed discussion of the 64-pad detector design, the substrate design. The front-end electronics used to read out the signals is based on a custom VLSI chip developed for the Advanced Thin Ionization Calorimeter experiment which has been flown successfully twice in Antarctica. Each of these chips has 16 channels and each channel consists of a charge-sensitive preamplifier followed by a shaping amplifier and a track-and-hold circuit. The track-and-hold circuits are connected via a multiplexer to an output line driver. This allows the held signals to be presented, one-by-one via a common data line to a analog-to-digital converter. Because the output line driver can be placed in a high input impedance state when not in use, it is possible to daisy-change many chips on the same common data line. The front-end electronics and data readout scheme will be discussed in detail. The Zero Degree Detector has been used in several accelerator experiments conducted at the NASA Space Radiation Laboratory and the Alternating Gradient Synchrotron at Brookhaven National Laboratory as well as at the HIMAC accelerator in Japan. We will show examples of data taken at these accelerator runs to demonstrate how the system works.

Adams, James H.↗

Development of the 3-D Track Imager for Medium and High-Energy Gamma-Ray Telescopes

The Advanced Compton Telescope (ACT) and Advanced Pair Telescope (APT) are envisioned as the next medium (0.3 ^ 50 MeV) and high-energy (30 MeV - greater than 100 GeV) gamma-ray missions. These missions will address many research focus areas of the Structure and Evolution of the Universe Roadmap. These areas include: element formation, matter, energy, & magnetic field interactions in galaxies, AGN & GRB emission, and behavior of matter in extreme environments of black holes & pulsars. Achieving these science goals requires a substantial increases in telescope sensitivity and angular resolution. This talk will discuss how these goals can be met with the three-dimensional track imager (3-DTI), a large volume, low density, time projection chamber with two-dimensional micro-well detector readout and report on our development of a 10 cm x 10 cm x 30 prototype instrument.

Hunter, Stanley D.↗

The Primordial Anisotropy Polarization Pathfinder Array (PAPPA): Instrument Overview and Status

PAPPA is a balloon-based experiment designed to measure the polarization of the Cosmic Microwave Background using candidate technology for an eventual Inflation Probe mission. It will survey a 20 x 20 degree patch of sky with 1 degree angular resolution covering 3 passbands centered at 100,200 and 300 GHz. Detection will be accomplished via antenna-coupled transition edge sensors (TESs) with SQUID-based readouts. In the eventual flight package, band defining filters and MEMS-based polarization modulators will be incorporated into the superconducting microstrip transmission lines that terminate in resistors that are thermally coupled to the TESs. The MEMS switches will allow on-chip polarization modulation that is faster than significant detector gain variations. The initial configuration will incorporate a simplified focal plane augmented by quasioptical polarization modulation. We describe the overall instrument design and present a summary of the current progress.

Chuss, David↗

The SWIFT Gamma-Ray Burst X-Ray Telescope

The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

Hill, J. E.↗

Progress towards high-performance thermopile imaging arrays

The purpose of this present work is to improve thermopile 2-D arrays substantially by combining Bi-Te and Bi-Sb-Te thermoelectric materials with a unique pixel structure and low-noise readout circuitry.

detector thermopile infrared uncooled array imagin↗

JPL CMOS Active Pixel Sensor Technology

This paper will present the JPL-developed complementary metal- oxide-semiconductor (CMOS) active pixel sensor (APS) technology. The CMOS APS has achieved performance comparable to charge coupled devices, yet features ultra low power operation, random access readout, on-chip timing and control, and on-chip analog to digital conversion. Previously published open literature will be reviewed.

Space Microelectronics Image Sensors APS Digital I↗

Algorithms for Unequal-Arm Michelson Interferometers

A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

Michelson Interferometer↗

Development of CMOS Active Pixel Image Sensors for Low Cost Commercial Applications

JPL, under sponsorship from the NASA Office of Advanced Concepts and Technology, has been developing a second-generation solid-state image sensor technology. Charge-coupled devices (CCD) are a well-established first generation image sensor technology. For both commercial and NASA applications, CCDs have numerous shortcomings. In response, the active pixel sensor (APS) technology has been under research. The major advantages of APS technology are the ability to integrate on-chip timing, control, signal-processing and analog-to-digital converter functions, reduced sensitivity to radiation effects, low power operation, and random access readout.

solid-state image sensors active pixel sensor APS ↗

NbN A/D Conversion of IR Focal Plane Sensor Signal at 10 K

We are implementing a 12 bit SFQ counting ADC with parallel-to-serial readout using our established 10 K NbN capability. This circuit provides a key element of the analog signal processor (ASP) used in large infrared focal plane arrays. The circuit processes the signal data stream from a Si:As BIB detector array. A 10 mega samples per second (MSPS) pixel data stream flows from the chip at a 120 megabit bit rate in a format that is compatible with other superconductive time dependent processor (TDP) circuits being developed. We will discuss our planned ASP demonstration, the circuit design, and test results.

conversion↗

Cosmic-ray Detector with Interdigitated-Finger Pixels for two-dimensional Position Information from a Singel Wafer Side

This paper describes a type of cosmic ray detector for isotopic and energy detection of energetic nuclei which derives both dimensions of position information from one side of the detector. This simplifies the required readout electronics, since only one precision amplifier connected to the other side is required for an accurate detection of the energy loss.

Cosmic-Ray Detector↗

A back-illuminated megapixel CMOS image sensor

In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.

Complementary Metal Oxide Semiconductor imager (CM↗

Integrated optics ring-resonator chemical sensor with polymer transduction layer

An integrated optics chemical sensor based on a ring resonator with an ethyl cellulose polymer coating has been demonstrated. The measured sensitivity to isopropanol in air is 50 ppm-the level immediately useful for health-related air quality monitoring. The resonator was fabricated using SiO2 and SixNy materials. The signal readout is based on tracking the wavelength of a resonance peak. The resonator layout optimisation for sensing applications is discussed.

chemical sensors.↗

Enhancing the ATIC Charge Resolution

The Advanced Thin Ionization Calorimeter (ATIC) experiment measures the energy spectra of elements, from H to Fe, in the energy region from about 100 GeV to tens of TeV. The ATIC instrument was flown twice in long-duration balloon flights around the South Pole; the ATIC-1 test flight during Dec. 2000 - Jan. 2001 and the ATIC-2 science flight during Dec. 2002 - Jan. 2003. Analyses of both datasets have, to date, relied upon the highly segmented Silicon Matrix (SiM) detector to separate the incident cosmic ray from the calorimeter backscatter and to identify the charge. This method has worked well, enabling ATIC to separate protons from helium and to resolve all the major species up through iron. This charge resolution can be significantly improved by restricting the analysis to particle trajectories that pass through two SiM pixels at the cost of using only a fraction of the potential instrument geometry. However, immediately below the SiM is the two layer SI hodoscope (x, y) consisting of Bicron BC-408 plastic scintillator 2 cm wide, 1 cm thick, 88.2 cm long strips viewed by Hamamatsu R5611 photomultiplier tubes on each end of each strip. The primary purpose of the ATIC hodoscopes is to provide a fast trigger, and each hodoscope includes two crossed layers of strips (42 per layer in the case of Sl) providing supplemental particle trajectory information. The hodoscope readout electronics were designed to provide reasonable charge resolution over the dynamic range from protons through iron. This presentation discusses the S 1 hodoscope energy deposit calibrations, examines the charge resolution possible with this detector and investigates combining the S1 and SiM charge measurements to improve the overall ATIC charge resolution while minimizing degradation of the instrument geometry.

Guzik, T. G.↗

Medical Monitoring during Short Radius Centrifugation in Bed-rested Subjects

The artificial gravity pilot project was designed to investigate the efficacy of daily exposure to a Gz acceleration gradient for counteracting the physiologic decrements induced by prolonged bed rest. A short radius centrifuge was used to produce a Gz gradient such that 1 g was applied at the level of the subject s heart and 2.5 g at the feet. For inclusion in the study, subjects were required to complete a 75-minute screening spin on the centrifuge. During the study, each active treatment subject was scheduled for a 60-minute spin each day for 20 consecutive days. During centrifugation, subjects were continuously monitored by a physician for signs and symptoms of pre-syncope, motion sickness, arrhythmias, joint/muscle pain and any other unanticipated problems. The physician was also present to provide emergency care in the case of a medical emergency. Cameras mounted on the centrifuge were used to provide a means of observing the subject s face and torso. Audio communication was continuously maintained. Other monitoring tools included two-lead EKG tracings, pulse oximetry, intermittent sphygmomanometer readings, lights in the peripheral visual field, and continuous blood pressure readout from a tonometry device. Thirty screening runs were attempted using twenty-seven subjects. Seven of these runs were terminated early for symptoms of pre-syncope, motion sickness, or GI distress. A total of eight subjects completed the active treatment arm of the study. Of the 160 centrifuge runs that were scheduled for these eight treatment subjects, 152 were completed, seven were terminated early, and one was not attempted. Of the seven early terminations, four were related to symptoms of pre-syncope, one to leg pain, one to GI discomfort, and one to equipment failure. Three terminations for adverse symptoms occurred on the first treatment day. Three terminations occurred on day nineteen of treatment and within 24 hours after scheduled soleus and quadriceps muscle biopsies. We have summarized the relative usefulness of the information obtained by the various monitoring modalities in making a decision to terminate a centrifuge run. The video and audio communication information was essential to the decision-making process. Heart rate and EKG tracings are considered valuable, even though no spins were terminated due to significant arrhythmias. The tonometer device was generally not reliable in this application. Our observations suggest that subjects may be less tolerant of centrifugation just after starting bed rest and after invasive procedures.

Reinertson, Randal↗

The Anti-Coincidence Detector for the GLAST Large Area Telescope

This paper describes the design, fabrication and testing of the Anti-Coincidence Detector (ACD) for the Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT). The ACD is LAT's first-level defense against the charged cosmic ray background that outnumbers the gamma rays by 3-5 orders of magnitude. The ACD covers the top and 4 sides of the LAT tracking detector, requiring a total active area of -8.3 square meters. The ACD detector utilizes plastic scintillator tiles with wave-length shifting fiber readout. In order to suppress self-veto by shower particles at high gamma-ray energies, the ACD is segmented into 89 tiles of different sizes. The overall ACD efficiency for detection of singly charged relativistic particles entering the tracking detector from the top or sides of the LAT exceeds the required 0.9997.

Moiseev, A. A.↗