Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Stabilized Nd:YAG laser output

Stabilization system consists of feedback-loop-controlled piezoelectric crystal to one of the reflectors to vary optical path length within laser cavity. Average second harmonic of fundamental 1.06 micrometer laser radiation is detected by integrating detector.

Osmundson, J.↗

The thermal instability in a sheared magnetic field - Filament condensation with anisotropic heat conduction

The condensation-mode growth rate of the thermal instability in an empirically motivated sheared field is shown to depend upon the existence of perpendicular thermal conduction. This typically very small effect (perpendicular conductivity/parallel conductivity less than about 10 to the -10th for the solar corona) increases the spatial-derivative order of the compressible temperature-perturbation equation, and thereby eliminates the singularities which appear when perpendicular conductivity = 0. The resulting growth rate is less than 1.5 times the controlling constant-density radiation rate, and has a clear maximum at a cross-field length of order 100 times and a width of about 0.1 the magnetic shear scale for solar conditions. The profiles of the observable temperature and density perturbations are independent of the thermal conductivity, and thus agree with those found previously. An analytic solution to the short-wavelength incompressible case is also given.

Van Hoven, G.↗

Vertebrate development in the environment of space: models, mechanisms, and use of the medaka

With the advent of space travel, it is of immediate interest and importance to study the effects of exposure to various aspects of the altered environment of space, including microgravity, on Earth-based life forms. Initial studies of space travel have focused primarily on the short-term effects of radiation and microgravity on adult organisms. However, with the potential for increased lengths of time in space, it is critical to now address the effects of space on all phases of an organism's life cycle, from embryogenesis to post-natal development to reproduction. It is already possible for certain species to undergo multiple generations within the confines of the Mir Space Station. The possibility now exists for scientists to consider the consequences of even potentially subtle defects in development through multiple phases of an organism's life cycle, or even through multiple generations. In this discussion, we highlight a few of the salient observations on the effects of the space environment on vertebrate development and reproductive function. We discuss some of the many unanswered questions, in particular, in the context of the choice of appropriate models in which to address these questions, as well as an assessment of the availability of hardware already existing or under development which would be useful in addressing these questions.

Flight Experiment↗

Liner Optimization Studies Using the Ducted Fan Noise Prediction Code TBIEM3D

In this paper we demonstrate the usefulness of the ducted fan noise prediction code TBIEM3D as a liner optimization design tool. Boundary conditions on the interior duct wall allow for hard walls or a locally reacting liner with axially segmented, circumferentially uniform impedance. Two liner optimization studies are considered in which farfield noise attenuation due to the presence of a liner is maximized by adjusting the liner impedance. In the first example, the dependence of optimal liner impedance on frequency and liner length is examined. Results show that both the optimal impedance and attenuation levels are significantly influenced by liner length and frequency. In the second example, TBIEM3D is used to compare radiated sound pressure levels between optimal and non-optimal liner cases at conditions designed to simulate take-off. It is shown that significant noise reduction is achieved for most of the sound field by selecting the optimal or near optimal liner impedance. Our results also indicate that there is relatively large region of the impedance plane over which optimal or near optimal liner behavior is attainable. This is an important conclusion for the designer since there are variations in liner characteristics due to manufacturing imprecisions.

Dunn, M. H.↗

Development of Detectability Limits for On-Orbit Inspection of Space Shuttle Wing Leading Edge

At the conclusion of the Columbia Accident Investigation, one of the recommendations of the Columbia Accident Investigation Board (CAIB) was that NASA develop and implement an inspection plan for the Reinforced Carbon-Carbon (RCC) system components of the Space Shuttle. To address these issues, a group of scientists and engineers at NASA Langley Research Center proposed the use of an IR camera to inspect the RCC. Any crack in an RCC panel changes the thermal resistance of the material in the direction perpendicular to the crack. The change in thermal resistance can be made visible by introducing a heat flow across the crack and using an IR camera to image the resulting surface temperature distribution. The temperature difference across the crack depends on the change in the thermal resistance, the length of the crack, the local thermal gradient, and the rate of radiation exchange with the environment. This paper describes how the authors derived the minimum thermal gradient detectability limits for a through crack in an RCC panel. This paper will also show, through the use of a transient, 3-dimensional, finite element model, that these minimum gradients naturally exist on-orbit. The results from the finite element model confirm that there are sufficient thermal gradient to detect a crack on 96% of the RCC leading edge.

Stephan, Ryan A.↗

Optimization for Single-Spike X-Ray FELs at LCLS with a Low Charge Beam

The Linac Coherent Light Source is an x-ray free-electron laser at the SLAC National Accelerator Laboratory, which is operating at x-ray wavelengths of 20-1.2 Angstrom with peak brightness nearly ten orders of magnitude beyond conventional synchrotron radiation sources. At the low charge operation mode (20 pC), the x-ray pulse length can be <10 fs. In this paper we report our numerical optimization and simulations to produce even shorter x-ray pulses by optimizing the machine and undulator setup at 20 pC charge. In the soft x-ray regime, with combination of slotted-foil or undulator taper, a single spike x-ray pulse is achievable with peak FEL power of a few 10s GW. Linac Coherent Light Source (LCLS), the world's first hard x-ray Free electron laser (FEL), has started operation since 2009. With nominal operation charge of 250 pC, the generated x-ray pulse length is from 70 fs to a few hundred fs. This marks the beginning of a new era of ultrashort x-ray sciences. In addition, a low charge (20pC) operation mode has also been established. Since the collective effects are reduced at the low charge mode, we can increase the compression factor and still achieve a few kA peak current. The expected electron beam and x-ray pulses are less than 10 fs. There are growing interests in even shorter x-ray pulses, such as fs to sub-fs regime. One of the simple solutions is going to even lower charge. As discussed, single-spike x-ray pulses can be generated using 1 pC charge. However, this charge level is out of the present LCLS diagnostic range. 20 pC is a reasonable operation charge at LCLS, based on the present diagnostic system. At 20 pC in the soft x-ray wavelength regime, we have experimentally demonstrated that FEL can work at undercompression or over-compression mode, such as 1 degree off the full-compression; at full-compression, however, there is almost no lasing. In hard x-ray wavelength regime, we observed that there are reasonable photons generated even at full-compression mode, although the photon number is less than that from under-compression or over-compression mode. Since we cannot measure the x-ray pulse length at this time scale, the machine is typically optimized for generating maximum photons, not minimum pulse length. In this paper, we study the methods of producing femtosecond (or single-spike) x-ray pulses at LCLS with 20 pC charge, based on start-to-end simulations. Figure 1 shows a layout of LCLS. The compression in the second bunch compressor (BC2) determines the final e-beam bunch length. However, the laser heater, dog-leg after the main linac (DL2) and collective effects also affect the final bunch length. To adjust BC2 compression, we can either change the L2 phase or BC2 R{sub 56}. In this paper we only tune L2 phase while keep BC2 R{sub 56} fixed. For the start-to-end simulations, we used IMPACT-T and ELEGANT tracking from the photocathode to the entrance of the undulator, after that the FEL radiation was simulated with GENESIS. IMPACT-T tracks about 10{sup 6} particles in the injector part until 135 MeV, including 3D space charge force. The output particles from IMPACT-T are smoothed and increased to 12 x 10{sup 6} to reduce high-frequency numerical noise for subsequent ELEGANT simulations, which include linear and nonlinear transport effects, a 1D transient model of CSR, and longitudinal space charge effects, as well as geometric and resistive wake fields in the accelerator. In GENESIS part, the longitudinal wake field from undulator chamber and longitudinal space field are also included.

43 PARTICLE ACCELERATORS↗

Optimization strategies for sustainable fuel cycle of the BR2 Reactor

The objective of the present study is to achieve a sustainable fuel cycle in a long term of reactor operation applying advanced in-core loading strategies. The optimization criteria concern mainly enhancement of nuclear safety by means of reactivity margins and minimization of the operational fuel cycle cost at a given (constant) power level and same or longer cycle length. An important goal is also to maintain the same or to improve the experimental performances. Current developments are focused on optimization of control rods localization; optimization of fresh and burnt fuel assemblies in-core distribution; optimization of azimuth and axial fuel burn up strategies, including fuel assembly rotating and flipping upside down. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electronic d-band properties of gold nanoclusters grown on amorphous carbon

The electronic d-band properties are important factors for the emerging catalytic activity of Au nanoclusters of sub-5-nm size. We analyzed the d-band properties of Au nanoclusters grown on amorphous carbon supports by photoelectron spectroscopy using synchrotron-radiation light coupled with high-resolution ion scattering spectrometry which enables us to estimate the size and shape of Au nanoclusters. The d-band width (W{sub d}), d-band center position (E{sub d}), and apparent 5d{sub 3/2}-d{sub 5/2} spin-orbit splitting (E{sub SO}) were determined as a function of a number of Au atoms per cluster (n{sub A}) and an average coordination number (n{sub C}) in a wide range (11<n{sub A}<1600). The W{sub d} and E{sub SO} values decrease steeply with decreasing n{sub A} below {approx}150 owing to band narrowing which is caused by hybridization of fewer wave functions of the valence electrons. However, E{sub d} shifts to the higher binding energy side with decreasing cluster size. The rapid movement of E{sub d} is attributed to the dynamic final-state effect, which results in higher binding energy shifts of core and valence states due to a positive hole created after photoelectron emission. We have estimated the contribution from the final-state effect and derived the approximated initial-state spectra. Modified data, however, still show a slight movement of the d-band center away from the Fermi level (E{sub F}) although the E{sub d} values for Au nanoclusters are closer to E{sub F} compared to the bulk value. This behavior is ascribed to the contraction of average Au-Au bond length with decreasing cluster size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence Report: Risk of Radiation Carcinogenesis

As noted by Durante and Cucinotta (2008), cancer risk caused by exposure to space radiation is now generally considered a main hindrance to interplanetary travel for the following reasons: large uncertainties are associated with the projected cancer risk estimates; no simple and effective countermeasures are available, and significant uncertainties prevent scientists from determining the effectiveness of countermeasures. Optimizing operational parameters such as the length of space missions, crew selection for age and sex, or applying mitigation measures such as radiation shielding or use of biological countermeasures can be used to reduce risk, but these procedures have inherent limitations and are clouded by uncertainties. Space radiation is comprised of high energy protons, neutrons and high charge (Z) and energy (E) nuclei (HZE). The ionization patterns and resulting biological insults of these particles in molecules, cells, and tissues are distinct from typical terrestrial radiation, which is largely X-rays and gamma-rays, and generally characterized as low linear energy transfer (LET) radiation. Galactic cosmic rays (GCR) are comprised mostly of highly energetic protons with a small component of high charge and energy (HZE) nuclei. Prominent HZE nuclei include He, C, O, Ne, Mg, Si, and Fe. GCR ions have median energies near 1 GeV/n, and energies as high as 10 GeV/n make important contributions to the total exposure. Ionizing radiation is a well known carcinogen on Earth (BEIR 2006). The risks of cancer from X-rays and gamma-rays have been established at doses above 50 mSv (5 rem), although there are important uncertainties and on-going scientific debate about cancer risk at lower doses and at low dose rates (<50 mSv/h). The relationship between the early biological effects of HZE nuclei and the probability of cancer in humans is poorly understood, and it is this missing knowledge that leads to significant uncertainties in projecting cancer risks during space exploration (Cucinotta and Durante 2006; Durante and Cucinotta 2008).

Huff, Janice↗

Radiative Heating Indicators and Uncertainty Analysis for Mars 2020

This paper will present analysis to evaluate a functional form and associated parameters to determine the radiative heating at various back-shell locations of the Mars 2020 aeroshell. The radiative heating indicators are used for preliminary vehicle design, and to determine the worst-case trajectories for peak radiative heat flux and load. Historically, the functional form for radiative heating is based on free-stream parameters of density, velocity and a length scale, typically the nose-radius (or equivalent). However, a fit of this form has been shown to not provide significant enough accuracy when compared to simulation results. Therefore, a fit based on post-shock equilibrium calculations of CO and CO2 number density, temperature and pressure has been devised. The results from the TPS 15 01 trajectory were used to develop the fit. The fit was then applied to the MSL best estimated trajectory (BET). Furthermore, the paper will quantify the uncertainty in simulations of the radiative heating for Mars 2020.

Mars 2020↗

SU-E-J-219: Quantitative Evaluation of Motion Effects On Accuracy of Image-Guided Radiotherapy with Fiducial Markers Using CT Imaging

Purpose: To investigate quantitatively patient motion effects on the localization accuracy of image-guided radiation with fiducial markers using axial CT (ACT), helical CT (HCT) and cone-beam CT (CBCT) using modeling and experimental phantom studies. Methods: Markers with different lengths (2.5 mm, 5 mm, 10 mm, and 20 mm) were inserted in a mobile thorax phantom which was imaged using ACT, HCT and CBCT. The phantom moved with sinusoidal motion with amplitudes ranging 0–20 mm and a frequency of 15 cycles-per-minute. Three parameters that include: apparent marker lengths, center position and distance between the centers of the markers were measured in the different CT images of the mobile phantom. A motion mathematical model was derived to predict the variations in the previous three parameters and their dependence on the motion in the different imaging modalities. Results: In CBCT, the measured marker lengths increased linearly with increase in motion amplitude. For example, the apparent length of the 10 mm marker was about 20 mm when phantom moved with amplitude of 5 mm. Although the markers have elongated, the center position and the distance between markers remained at the same position for different motion amplitudes in CBCT. These parameters were not affected by motion frequency and phase in CBCT. In HCT and ACT, the measured marker length, center and distance between markers varied irregularly with motion parameters. The apparent lengths of the markers varied with inverse of the phantom velocity which depends on motion frequency and phase. Similarly the center position and distance between markers varied inversely with phantom speed. Conclusion: Motion may lead to variations in maker length, center position and distance between markers using CT imaging. These effects should be considered in patient setup using image-guided radiation therapy based on fiducial markers matching using 2D-radiographs or volumetric CT imaging.

60 APPLIED LIFE SCIENCES↗

Diffusion length variation in 0.5- and 3-MeV-proton-irradiated, heteroepitaxial indium phosphide solar cells

Indium phosphide (InP) solar cells are more radiation resistant than gallium arsenide (GaAs) and silicon (Si) solar cells, and their growth by heteroepitaxy offers additional advantages leading to the development of light weight, mechanically strong, and cost-effective cells. Changes in heteroepitaxial InP cell efficiency under 0.5- and 3-MeV proton irradiations have been explained by the variation in the minority-carrier diffusion length. The base diffusion length versus proton fluence was calculated by simulating the cell performance. The diffusion length damage coefficient, K(sub L), was also plotted as a function of proton fluence.

Jain, Raj K.↗

A global climatology of albedo, roughness length and stomatal resistance for atmospheric general circulation models as represented by the Simple Biosphere Model (SiB)

Components of the Simple Biosphere Model (SiB) of Sellers et al. (1986) were used to generate global monthly fields of surface albedo (0.4-4.0 microns), roughness length and minimum surface (stomatal) resistance. SiB consists of three submodels which describe the roles of radiative transfer, turbulent transfer and surface resistance in determining the energy balance of the vegetated land surface. These three submodels were detached from SiB and used on the SiB parameter set (total and green leaf area index, leaf angle orientation, canopy dimensions, etc.) to calculate global monthly fields of albedo, roughness length and minimum stomatal resistance at 1 x 1 deg resolution. Time series of various parameters are also displayed for each vegetation type for specified grid points. The SiB results compare reasonably well with appropriate measurements obtained from the literature and have the additional merit of being mutually consistent; the three submodels use many common parameters, which ensures that, for each grid area, the calculated surface properties are closely interrelated as is the case in nature. The derived fields provide a check on the operation of the submodels and the correctness of the parameter set. They can also be used as prescribed fields for GCMs that do not have biophysically based land surface parameterizations.

Dorman, J. L.↗

Self-focusing of profiled ultrashort-wavelength laser beams in air

We report on the results of laboratory experiments of filamentation of sharply focused gigawatt femtosecond laser radiation passed through various aperture diaphragms in air. For the multiple filamentation regime, the dependences of the length and spatial structure of the filamentation region on the initial beam profile are established. It is found that light beam profiling by a diaphragm leads in some cases to a displacement of the filamentation region and to repeated self-focusing of radiation behind the linear focal waist. In the beam of the same power in the absence of a diaphragm and in the regime of the formation of a single filament, this effect terminates in front of the geometrical focus. The experimental results are illustrated by numerical simulation data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acoustic Radiation Pressure

The theoretical foundation of acoustic radiation pressure in plane wave beams is reexamined. It is shown from finite deformation theory and the Boltzmann-Ehrenfest Adiabatic Principle that the Brillouin stress tensor (BST) is the radiation stress in Lagrangian coordinates (not Eulerian coordinates) and that the terms in the BST are not the momentum flux density and mean excess Eulerian stress but are simply contributions to the variation in the wave oscillation period resulting from changes in path length and true wave velocity, respectively, from virtual variations in the strain. It is shown that the radiation stress in Eulerian coordinates is the mean Cauchy stress (not the momentum flux density, as commonly assumed) and that Langevin's second relation does not yield an assessment of the mean Eulerian pressure, since the enthalpy used in the traditional derivations is a function of the thermodynamic tensions - not the Eulerian pressure. It is shown that the transformation between Lagrangian and Eulerian quantities cannot be obtained from the commonly-used expansion of one of the quantities in terms of the particle displacement, since the expansion provides only the difference between the value of the quantity at two different points in Cartesian space separated by the displacement. The proper transformation is obtained only by employing the transformation coefficients of finite deformation theory, which are defined in terms of the displacement gradients. Finite deformation theory leads to the result that for laterally unconfined, plane waves the Lagrangian and Eulerian radiation pressures are equal with the value (1/4)(2K) along the direction of wave propagation, where (K) is the mean kinetic energy density, and zero in directions normal to the propagation direction. This is contrary to the Langevin result that the Lagrangian radiation pressure in the propagation direction is equal to (2K) and the BST result that the Eulerian radiation pressure in that direction is the momentum flux density.

Finite deformation theory↗

Reply to Comment by Cole-dai Et Al. on "Climatic Impact of the Long-lasting Laki Eruption: Inapplicability of Mass-independent Sulfur Isotope Composition Measurements"

Here we respond to the comments by Cole-Dai et al. [2014] on our article Schmidt et al. [2012]. Specifically, in response to section 2 of their reply, we argued in Schmidt et al. [2012] that based on previously published estimates of the volatile release height during the 1783-1784 C.E. Laki eruption, the lack of a sulfur massindependent fractionation (MIF) anomaly is expected. In other words, no previous study on Laki ever argued that this eruption emitted SO2 into altitudes >13-15 km. In section 2.3, Cole-Dai et al. [2014] argue that the nonzero Δ33S value of their Laki sample 1 may be explained by a short-lived explosive phase at Laki during which volatiles reached the stratosphere. In Schmidt et al. [2012] in section 2, we argued in agreement with Cole-Dai et al. [2014] (section 3.1) that for a MIF anomaly to be preserved, the Laki volatiles would have had to be emitted in >20 km altitude. Our main point is that eruption column heights >20 km are unlikely based on the historical accounts and plume-rise modeling for the Laki eruption [Stothers et al., 1986; Woods, 1993; Thordarson and Self, 2003]. In Schmidt et al. [2012], we argued that to deduce a short-lived climatic impact of the Laki eruption based on the lack of a MIF anomaly and the length of the sulfate deposition in Greenland ice cores may be misleading because the climatic impact will outlast the radiative forcing of the Laki aerosol cloud. Cole-Dai et al. [2014] acknowledge the latter in their reply in section 4.2. We agreewith Cole-Dai et al. [2014] in that themagnitude and length of the climatic impact during the winter of 1783-1784 depends on the altitude of the volatile release during the eruption (sections 2.3 and 4.2). However, even if we assumed that during Laki all sulfur dioxide (SO2) would have been released in the troposphere, then the aerosol cloud would still be present in the upper troposphere during March 1784, as is evident from independent model simulations of this "tropospheric-only" scenario [Stevenson et al., 2003]. We acknowledge that there is uncertainty on the volatile release height for Laki; however, it is worth considering that those climate model simulations that used an injection altitude between 9 km and 13 km for the Laki SO2 [Highwood and Stevenson, 2003; Oman et al., 2006a, 2006b; Schmidt et al., 2012] best match the observed temperature changes during summer of 1783 [Angell and Korshover, 1985; Brázdil et al., 2010; Briffa et al., 1998; D'Arrigo and Jacoby, 1999; Jacoby et al., 1999; Kington, 1988; Manley, 1974; Parker et al., 1992; Thordarson and Self, 2003]. Based on these model simulations, a climatic impact during the winter of 1783-1784, albeit weaker than during the climactic phases of Laki, is expected (and our argument here does not exclude the role of natural variability in contributing to the cold winter of 1783-1784 as discussed in Schmidt et al. [2012]). Therefore, we continue to argue that for high-latitude eruptions such as Laki, the applicability of sulfur isotopic measurements to interpret the climatic relevance has yet to be demonstrated. Itmay transpire that the interpretation of MIF signals for the climate-relevance of an eruption is valid and unambiguous only for short-lived explosive eruptions in the tropics. In terms of the processes producing a MIF anomaly (section 3.3 in Cole-Dai et al. [2014]), the works by Hattori et al. [2013] and Ono et al. [2013] suggest that there are remaining issues not discussed by Cole-Dai et al. [2014], for instance, self-shielding of SO2 due to high column densities typical for eruptions of Pinatubo-scale and greater, and the preservation of the MIF signature in general.

general circulation model↗

Radiation Exposure During Transarterial Chemoembolization: Angio-CT Versus Cone-Beam CT

Introduction: Cone-beam computed tomography (CBCT) has been developed to improve reliability of many interventional radiology (IR) procedures performed with Angio system, such as transarterial chemoembolization (TACE). Angio-CT has emerged as a new imaging technology that combines a CT scanner with an Angio system in the same IR suite. The purpose of our study was to compare Angio system with CBCT capability and Angio-CT in terms of patient radiation exposure during TACE procedures. Materials and Methods: Consecutive TACE procedures performed between January 2016 and September 2017 with the two imaging modalities (Artis Zeego defining the CBCT group and Infinix-i 4D-CT defining the Angio-CT group) were reviewed. TACE and patient’s characteristics and patient radiation exposure parameters were collected. Dose-area products (DAP) and dose-length products (DLP) were converted into effective doses (ED) using conversion factors. Accuracy of tumor targeting and response was retrospectively assessed. Results: A total of 114 TACE procedures in 96 patients were included with 57 procedures in each group. The total ED in the Angio-CT group was 2.5 times lower than that in the CBCT group (median 15.4 vs. 39.2 mSv, p < 0.001). Both 2D ED and 3D ED were lower in the Angio-CT group than in the CBCT group (5.1 vs. 20 mSv, p < 0.001, and 7.4 vs. 17.9 mSv, p < 0.001, respectively). There was no significant difference neither in terms of classes of tumor targeting (p = 0.509) nor in terms of classes of tumor response (p = 0.070) between both groups. Conclusion: Angio-CT provides significant decrease in patient effective dose during TACE procedures compared to Angio system with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗