Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Characterization of Structural Vibration and Acoustic Radiation with a Beam-Array Doppler Vibrometer

This paper discusses the operational principles of an assembly of two opto-electronic modules with their configurations based on a Laser-Array Doppler Vibrometer (LADV) and a Shack-Hartmann Wavefront Sensor (SHWFS). Both sensors can operate concurrently providing complementary data. While the SHWFS is a well-established system that enables low-bandwidth spatio-temporal characterization of aerodynamic turbulence, the LADV technology allows real-time detection of structural vibrations and associated acoustic radiation fields. Practical examples are shown of the instruments’ capabilities, focusing on the ability to simultaneously capture, visualize and quantitatively characterize full-field non-stationary structural dynamics and unsteady sound fields or transient flow fields around ground test facility airframe models or other structures of interest. The parallel multi-channel architecture of the LADV system enables synchronous detection and temporal correlation of indicators related to the spatio-temporal vibration of the structure under inspection. This unique feature is essential for real time detection and categorization of the structural and acoustic dynamics of transient events. For the present study, the LADV data have been successfully compared with measurements obtained with the SHWFS in the wake of a subsonic scale-model airfoil. The ability of the LADV-SHWFS coupled measurements to perform real time non-intrusive evaluation and characterization of dynamic processes at operationally relevant bandwidths should provide a deeper insight into the complex structural dynamics that contribute to radiated sound fields.

Vladimir B Markov↗

Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife

For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. These relatively large areas of electronic disequilibrium make accurate dosimetry as well as dose calculation more difficult, and this is exacerbated in regions of tissue heterogeneity. Tissue heterogeneity was considered insignificant in the brain where stereotactic radiosurgery was first used. However, as this technique is expanded to the head and neck and other body sites, dose calculations need to account for dose perturbations in and beyond air cavities, lung, and bone. In a previous study we have evaluated EBT Gafchromic film (International Specialty Products, Wayne, NJ) for dosimetry and characterization of the Cyberknife radiation beams and found that it was comparable to other common detectors used for small photon beams in solid water equivalent phantoms. In the present work EBT film is used to measure dose in heterogeneous slab phantoms containing lung and bone equivalent materials for the 6 MV radiation beams of diameter 7.5 to 40 mm produced by the Cyberknife (Accuray, Sunnyvale, CA). These measurements are compared to calculations done with both the clinically utilized Raytrace algorithm as well as the newly developed Monte Carlo based algorithm available on the Cyberknife treatment planning system. Within the low density material both the measurements and Monte Carlo calculations correctly model the decrease in dose produced by a loss of electronic equilibrium, whereas the Raytrace algorithm incorrectly predicts an enhancement of dose in this region. Beyond the low density material an enhancement of dose is correctly calculated by both algorithms. Within the high density bone heterogeneity the EBT film measurements represent dose to unit density tissue in bone and agree with the Monte Carlo results when corrected to dose to unit density tissue in bone. We conclude that EBT film is an appropriate dosimeter for measuring dose in heterogeneous materials and these measurements agree with Monte Carlo calculations of dose as implemented in the Cyberknife treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

HIRF Tolerance and Avoidance for Advanced Air Mobility Vehicles

Advanced Air Mobility (AAM), including Urban Air Mobility (UAM), and Unmanned Aerial Systems (UAS) vehicles may fly in similar airspace to Transport Category Rotorcraft, thereby requiring meeting the same stringent High-Intensity Radiated Fields (HIRF) certification requirements. In a previous effort, a proposed map-based approach protects a vehicle by keeping it away from high power sources at safe distances based on its tolerance level. By designing to a lower tolerance level, significant cost savings can be achieved at the cost of slightly more complex flight planning. However, too low a threshold can result in large avoidance areas, potentially reducing the vehicle operating space. This current effort suggests a minimum threshold for vehicles operating in an urban area. It is derived from analyzing regulatory transmitter data for New York City as a representative metropolitan. As a result, a vehicle can tolerate common lower-power transmitters by default and only needs to avoid far less common high-power sources. It is also found the existing HIRF requirements may be insufficient against many powerful transmitters such as weather radars and satellite uplink transmitters, and that the map-based approach can address this concern.

HIRF↗

Monte Carlo study for designing a dedicated “D”-shaped collimator used in the external beam radiotherapy of retinoblastoma patients

Purpose: Retinoblastoma is the most common intraocular malignancy in the early childhood. Patients treated with external beam radiotherapy respond very well to the treatment. However, owing to the genotype of children suffering hereditary retinoblastoma, the risk of secondary radio-induced malignancies is high. The University Hospital of Essen has successfully treated these patients on a daily basis during nearly 30 years using a dedicated “D”-shaped collimator. The use of this collimator that delivers a highly conformed small radiation field, gives very good results in the control of the primary tumor as well as in preserving visual function, while it avoids the devastating side effects of deformation of midface bones. The purpose of the present paper is to propose a modified version of the “D”-shaped collimator that reduces even further the irradiation field with the scope to reduce as well the risk of radio-induced secondary malignancies. Concurrently, the new dedicated “D”-shaped collimator must be easier to build and at the same time produces dose distributions that only differ on the field size with respect to the dose distributions obtained by the current collimator in use. The scope of the former requirement is to facilitate the employment of the authors' irradiation technique both at the authors' and at other hospitals. The fulfillment of the latter allows the authors to continue using the clinical experience gained in more than 30 years. Methods: The Monte Carlo codePENELOPE was used to study the effect that the different structural elements of the dedicated “D”-shaped collimator have on the absorbed dose distribution. To perform this study, the radiation transport through a Varian Clinac 2100 C/D operating at 6 MV was simulated in order to tally phase-space files which were then used as radiation sources to simulate the considered collimators and the subsequent dose distributions. With the knowledge gained in that study, a new, simpler, “D”-shaped collimator is proposed. Results: The proposed collimator delivers a dose distribution which is 2.4 cm wide along the inferior-superior direction of the eyeball. This width is 0.3 cm narrower than that of the dose distribution obtained with the collimator currently in clinical use. The other relevant characteristics of the dose distribution obtained with the new collimator, namely, depth doses at clinically relevant positions, penumbrae width, and shape of the lateral profiles, are statistically compatible with the results obtained for the collimator currently in use. Conclusions: The smaller field size delivered by the proposed collimator still fully covers the planning target volume with at least 95% of the maximum dose at a depth of 2 cm and provides a safety margin of 0.2 cm, so ensuring an adequate treatment while reducing the irradiated volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

POLARIZED LINE FORMATION IN MOVING ATMOSPHERES WITH PARTIAL FREQUENCY REDISTRIBUTION AND A WEAK MAGNETIC FIELD

The dynamical state of the solar and stellar atmospheres depends on the macroscopic velocity fields prevailing within them. The presence of such velocity fields in the line formation regions strongly affects the polarized radiation field emerging from these atmospheres. Thus it becomes necessary to solve the radiative transfer equation for polarized lines in moving atmospheres. Solutions based on the “observer’s frame method” are computationally expensive to obtain, especially when partial frequency redistribution (PRD) in line scattering and large-amplitude velocity fields are taken into account. In this paper we present an efficient alternative method of solution, namely, the comoving frame technique, to solve the polarized PRD line formation problems in the presence of velocity fields. We consider one-dimensional planar isothermal atmospheres with vertical velocity fields. We present a study of the effect of velocity fields on the emergent linear polarization profiles formed in optically thick moving atmospheres. We show that the comoving frame method is far superior when compared to the observer’s frame method in terms of the computational speed and memory requirements.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiative neutrino decay in a strong magnetic field

The radiative decay of neutrinos in a strong magnetic field that have relatively high energies, E ≫ m{sub e}, is studied with allowance for positronium contribution to the photon polarization operator in the vicinity of the cyclotron resonance. It is shown that the probability for the process ν → νγ increases substantially upon taking into account the positronium contribution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nimbus 7 earth radiation budget wide field of view climate data set improvement. II - Deconvolution of earth radiation budget products and consideration of 1982-1983 El Nino event

A deconvolution technique is employed that permits recovery of daily averaged earth radiation budget (ERB) parameters at the top of the atmosphere from a set of the Nimbus 7 ERB wide field of view (WFOV) measurements. Improvements in both the spatial resolution of the resultant fields and in the fidelity of the time averages is obtained. The algorithm is evaluated on a set of months during the period 1980-1983. The albedo, outgoing long-wave radiation, and net radiation parameters are analyzed. The amplitude and phase of the quasi-stationary patterns that appear in the spatially deconvolved fields describe the radiation budget components for 'normal' as well as the El Nino/Southern Oscillation (ENSO) episode years. They delineate the seasonal development of large-scale features inherent in the earth's radiation budget as well as the natural variability of interannual differences. These features are underscored by the powerful emergence of the 1982-1983 ENSO event in the fields displayed. The conclusion is that with this type of resolution enhancement, WFOV radiometers provide a useful tool for the observation of the contemporary climate and its variability.

Ardanuy, Phillip E.↗

A HIRF-Map Certification Approach for UAM, AAM, and UAS Vehicles

Advanced Air Mobility (AAM), Urban Air Mobility (UAM), and Unmanned Aerial Systems (UAS) vehicles will fly in airspace similar to Transport Category Rotorcraft, requiring them to meet stringent requirements for High-Intensity Radiated Fields (HIRF) certification. The environment is notably severe, particularly compared to fixed-wing aircraft, due to operations at lower altitudes. This potentially exposes the vehicles to high-power transmitters on the ground, leading to significant challenges. High-level HIRF exposure can result in avionic system upsets, interference, and undesirable effects. Shielding and circuit protection against HIRF pose significant barriers concerning size, weight, and cost, especially for emerging electric vertical take-off and landing (eVTOL) and electric short take-off and landing (eSTOL) vehicles. This paper proposes a novel HIRF protection approach, aiming to reduce costs by certifying vehicles to a "vehicle tolerance level" lower than that required for Transport Category Rotorcraft. The remaining protection is achieved by maintaining a safe distance from known HIRF sources. This distance is calculated based on the vehicle's tolerance level and transmitter characteristics, such as transmit power, antenna beamwidth, and direction. Tailored flight maps are developed to identify transmitters and avoidance zones within an operating area or along a flight path, enabling restricted vehicle operations. Vehicles with higher tolerance levels could have smaller HIRF avoidance zones, allowing them to operate closer to transmitters. Transmitter data are sourced from government databases, such as those of the Federal Communications Commission (FCC) and the National Oceanic and Atmospheric Administration (NOAA). A map tool is developed using Matlab to calculate and visualize HIRF avoidance zones based on available databases. The tool determines stand-off distances based on input vehicle tolerance levels, displaying results on various base maps depicting HIRF-restricted areas. Illustrations cover various FCC transmitters, including AM/FM/TV transmitters, satellite earth stations, and NOAA weather radars. The HIRF zones of smaller transmitters, such as land-mobile radios, pagers, microwave links, and cellular towers, are also illustrated. An example of flight planning around transmitters is provided. For now, airports and government-owned lands are excluded due to limited access to sensitive transmitter data. Despite this approach, a minimum HIRF tolerance level for vehicles may still be necessary to cover mobile devices, cellular base stations, transmitters on other AAM vehicles, and other small power devices not included in the FCC databases. The paper discusses findings and areas for improving existing databases and suggests an approach for better access to sanitized data in more restricted government databases. This method significantly deviates from the standard approach and introduces slightly higher flight-planning complexity. However, the potential cost savings are considerable. Future AAM/UAM/UAS aeronautical charts could potentially incorporate these new HIRF avoidance zones. Keywords—HIRF; Map; AAM; UAM; UAS; Advanced Air Mobility; Urban Air Mobility; Unmanned Aerial Systems; Certification.

HIRF↗

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface-wave-assisted nonreciprocity in spatio-temporally modulated metasurfaces

Emerging photonic functionalities are mostly governed by the fundamental principle of Lorentz reciprocity. Lifting the constraints imposed by this principle could circumvent deleterious effects that limit the performance of photonic systems. Most efforts to date have been limited to waveguide platforms. Here, we propose and experimentally demonstrate a spatiotemporally modulated metasurface capable of complete violation of Lorentz reciprocity by reflecting an incident beam into far-field radiation in forward scattering, but into near-field surface waves in reverse scattering. These observations are shown both in nonreciprocal beam steering and nonreciprocal focusing. We also demonstrate nonreciprocal behavior of propagative-only waves in the frequency- and momentum-domains, and simultaneously in both. We develop a generalized Bloch-Floquet theory which offers physical insights into Lorentz nonreciprocity for arbitrary spatial phase gradients, and its predictions are in excellent agreement with experiments. Our work opens exciting opportunities in applications where free-space nonreciprocal wave propagation is desired.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Curium(iii) radiation-induced reaction kinetics in aqueous media

Insight into the effects of radiolytic processes on the actinides is critical for advancing our understanding of their solution chemistry because the behaviour of these elements cannot be easily separated from the influence of their inherent radiation field. However, minimal information exists on the radiation-induced redox behaviour of curium (Cm), a key trivalent transuranic element present in used nuclear fuel and frequently used as an alpha radiation source. Here we present a kinetic study on the aqueous redox reactions of Cm(III) with radicals generated through the radiolysis of aqueous media. In particular, we probe reaction kinetics in nitric acid solutions that are used as the aqueous phase component of used nuclear fuel reprocessing solvent systems. Second-order rate coefficients (k) were measured for the reaction of Cm(III) with the hydrated electron (e aq - , k = (1.25 ± 0.03) × 10 10 M -1 s -1 ), hydrogen atom (H˙, k = (5.16 ± 0.37) × 10 8 M -1 s -1 ), hydroxyl radical (˙OH, k = (1.69 ± 0.24) × 10 9 M -1 s -1 ), and nitrate radical (NO 3 ˙, k = (4.83 ± 0.09) × 10 7 M -1 s -1 ). Furthermore, the first-ever Cm(II) absorption spectrum (300–700 nm) is also reported. These kinetic data dispel the status quo notion of Cm(III) possessing little to no redox chemistry in aqueous solution, and suggest that the resulting Cm(II) and Cm(IV) transients could exist in irradiated aqueous solutions and be available to undergo subsequent redox chemistry with other solutes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MO-FG-202-07: Real-Time EPID-Based Detection Metric For VMAT Delivery Errors

Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling and translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error source. J. V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

On the Number of Photons in a Classical Electromagnetic Field

Relations determining the number of photons in an electromagnetic field are considered from the point of view of a classical electromagnetic field. A relativistically invariant expression is obtained for the number of emitted photons in terms of charges and currents producing the electromagnetic field. Examples are considered for calculating the numbers of photons in the electromagnetic field for the case of the electric dipole radiation field, as well as the field of a finite and spatially restricted electromagnetic pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-driven Explosions of Stripped High-mass Stars: Synthetic Light Curves and Spectra of Stripped-envelope Supernovae with Broad Light Curves

Stripped-envelope supernovae (SESNe) represent a significant fraction of core-collapse supernovae, arising from massive stars that have shed their hydrogen and, in some cases, helium envelopes. The origins and explosion mechanisms of SESNe remain a topic of active investigation. In this work, we employ radiative-transfer simulations to model the light curves and spectra of a set of explosions of single, solar-metallicity, massive Wolf–Rayet stars with ejecta masses ranging from 4 to 11 M ⊙ , which were computed from a turbulence-aided and neutrino-driven explosion mechanism. We analyze these synthetic observables to explore the impact of varying ejecta mass and helium content on observable features. We find that the light curve shape of these progenitors with high ejecta masses is consistent with observed SESNe with broad light curves but not the peak luminosities. The commonly used analytic formula based on rising bolometric light curves overestimates the ejecta mass of these high-initial-mass progenitor explosions by a factor of up to 2.6. In contrast, the calibrated method by Haynie et al., which relies on late-time decay tails, reduces uncertainties to an average of 20% within the calibrated ejecta mass range. Spectroscopically, the He I 1.083 μm line remains prominent even in models with as little as 0.02 M ⊙ of helium. However, the strength of the optical He I lines is not directly proportional to the helium mass but instead depends on a complex interplay of factors such as the 56 Ni distribution, composition, and radiation field. Thus, producing realistic helium features requires detailed radiative transfer simulations for each new hydrodynamic model.

79 ASTRONOMY AND ASTROPHYSICS↗

Unsteady temperature distribution in volume reflectors

The development of unsteady temperature distributions in semitransparent scattering materials under the influence of arbitrary incident radiative flux with other than specified temperature boundary conditions is considered. Specifically, such a problem is considered for an approximate radiative transfer model which allows analytic solutions. The model represents the unsteady, one-dimensional, radiative heating of a weakly absorbing, semitransparent medium with specified conductive heat flux at one boundary. The radiation field is modeled using an approximation to the radiative heat flux obtained by solution of the Kubelka-Munk differential equations.

Weston, K. C.↗

Evolution of polar stratospheric clouds during the Antarctic winter

The occurrence of Polar Stratospheric Clouds (PSCs), initially inferred from satellite measurements of solar extinction, have now also been noted by the recent scientific expeditions in the Antarctic. The presence of such clouds in the Antarctic has been postulated to play a significant role in the depletion of ozone during the transition from winter to spring. The mechanisms suggested involve both dynamical and chemical processes which, explicity or implicitly, are associated with the ice particles constituting the PSCs. It is, thus, both timely and necessary to investigate the evolution of these clouds and ascertain the nature and magnitude of their influences on the state of the Antarctic stratosphere. To achieve these objectives, a detailed microphysical model of the processes governing the growth and sublimation of ice particles in the polar stratosphere was developed, based on the investigations of Ramaswamy and Detwiler. The present studies focus on the physical processes that occur at temperatures below those required for the onset of ice deposition from the vapor phase. Once these low temperatures are attained, the deposition of water vapor onto nucleation particles becomes extremely significant. First, the factors governing the magnitude of growth and the growth rate of ice particles at various altitudes are examined. Second, the ice phase mechanisms are examined in the context of a column model with altitudes ranging from 100 to 5 mb pressure levels. The column microphysical model was used to perform simulations of the cloud evolution, using the observed daily temperatures. The effect due to the growth of the particles on the radiation fields are also investigated using a one dimensional radiative transfer model. Specifically, the perturbations in the longwave cooling and that in the shortwave heating for the late winter/early spring time period are analyzed.

Ramaswamy, V.↗

Kinetics model for initiation and promotion for describing tumor prevalence from HZE radiation

A kinetics model for cellular repair and misrepair for multiple radiation-induced lesions (mutation-inactivation) is coupled to a two-mutation model of initiation and promotion in tissue to provide a parametric description of tumor prevalence in the Harderian gland in a mouse. Dose-response curves are described for gamma-rays and relativistic ions. The effects of nuclear fragmentation are also considered for high-energy proton and alpha particle exposures The model described provides a parametric description of age-dependent cancer induction for a wide range of radiation fields. We also consider the two hypotheses that radiation acts either solely as an initiator or as both initiator and promoter and make model calculations for fractionation exposures from gamma-rays and relativistic Fe ions. For fractionated Fe exposures, an inverse dose-rate effect is provided by a promotion hypothesis using a mutation rate for promotion typical of single-gene mutations.

Cucinotta, Francis A.↗