Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Searches for dark matter subhaloes with wide-field Cherenkov telescope surveys

The presence of substructures in dark matter haloes is an unavoidable consequence of the cold dark matter paradigm. Indirect signals from these objects have been extensively searched for with cosmic rays and {gamma} rays. At first sight, Cherenkov telescopes seem not very well suited for such searches, due to their small fields of view and the random nature of the possible dark matter substructure positions in the sky. However, with long enough exposure and an adequate observation strategy, the very good sensitivity of this experimental technique allows us to constrain particle dark matter models. We confront here the sensitivity map of the HESS experiment built out of their Galactic scan survey to the state-of-the-art cosmological N-body simulation Via Lactea II. We obtain competitive constraints on the annihilation cross section, at the level of 10{sup -24}-10{sup -23} cm{sup 3} s{sup -1}. The results are extrapolated to the future Cherenkov Telescope Array, in the cases of a Galactic plane survey and of an even wider extragalactic survey. In the latter case, it is shown that the sensitivity of the Cherenkov Telescope Array will be sufficient to reach the most natural particle dark matter models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First study of the $^{139}\text{Ba}(n,y)^{140}\text{Ba}$ reaction to constrain the conditions for the astrophysical $\mathcal{i}$ process

New astronomical observations point to a nucleosynthesis picture that goes beyond what was accepted until recently. The intermediate “i” process was proposed as a plausible scenario to explain some of the unusual abundance patterns observed in metal-poor stars. The most important nuclear physics properties entering i-process calculations are the neutron-capture cross sections and they are almost exclusively not known experimentally. In this report we provide the first experimental constraints on the 139 Ba(n,γ) 140 Ba reaction rate, which is the dominant source of uncertainty for the production of lanthanum, a key indicator of i-process conditions. This is an important step towards identifying the exact astrophysical site of stars carrying the i-process signature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrahigh supercurrent density in a two-dimensional topological material

Ongoing advances in superconductors continue to revolutionize technology thanks to the increasingly versatile and robust availability of lossless supercurrents. In particular, high supercurrent density can lead to more efficient and compact power transmission lines, high-field magnets, as well as high-performance nanoscale radiation detectors and superconducting spintronics. In this work, we report the discovery of an unprecedentedly high superconducting critical current density (17 MA / cm 2 at 0 T and 7 MA / cm 2 at 8 T) in 1T'–WS 2 , exceeding those of all reported two-dimensional superconductors to date. 1T'–WS 2 features a strongly anisotropic (both in- and out-of-plane) superconducting state that violates the Pauli paramagnetic limit signaling the presence of unconventional superconductivity. Spectroscopic imaging of the vortices further substantiates the anisotropic nature of the superconducting state. More intriguingly, the normal state of 1T'–WS 2 carries topological properties. The band structure obtained via angle-resolved photoemission spectroscopy and first-principles calculations points to a Z 2 topological invariant. The concomitance of topology and superconductivity in 1T'–WS 2 establishes it as a topological superconductor candidate, which is promising for the development of quantum computing technology.

36 MATERIALS SCIENCE↗

Point defects in CdTe and CdSeTe alloy: a first principles investigation with DFT+U

CdTe and its alloy CdSeTe are widely used in optoelectronic devices, such as radiation detectors and solar cells, due to their superior electrical properties. However, the formation of defects and defect complexes in these materials can significantly affect their performance. As a result, understanding the defect formation and recombination processes in CdTe and CdSeTe alloy is of great importance. In recent years, density functional theory (DFT) calculations have emerged as a powerful tool for investigating the properties of defects in semiconductors. In this paper, we use DFT+U calculations to comprehensively study the properties of intrinsic defects as well as extrinsic defects induced by commonly used dopants, such as Cu and group V elements, in CdTe and CdSeTe alloy. This work provides insights into the effects of these defects on the electrical and optical properties of the material.

14 SOLAR ENERGY↗

Challenges for Interdiction of Nuclear Threats at Borders

Paper for the ANIMMA (International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications) conference proceedings on the general topic of border screening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reactor Facility Operational State Classification Using Gas Effluents and Radiation Measurements

Inferring the operational state of a reactor facility, using measurements from an independent in-situ monitoring system, is critical to the assessment of its compliance to agreements. We consider the problem of inferring the on/off operational state of a facility by using gas effluents and radiation measurements collected at the reactor's off-gas ventilation stack and within its surrounding area. Effluent release concentrations of three noble gases, namely, Ar-41, Cs-138, and Xe-138, are collected inside the ventilation stack and provided every four hours. Gamma spectra is recorded every second by a radiation detector located about 100 meters offset from the stack, which is affected by weather and nearby conditions. We study classifiers based on the correlation coefficient (CC) method [1] applied to individual modalities and their combinations. We implement CC classifiers using ground truth measurements collected over 2 operational cycles of High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) in year 2017.

Ramirez Aviles, Camila A.↗

Investigation of Timing Properties for an Event Driven with Access and Reset Decoder Readout Architecture for a Pixel Array

The large number of data generating sources (data channels) on a single chip requires appropriate techniques to manage a readout from these channels. One of the main methods is sharing a medium of transmission, which requires arbitration to avoid collisions or deadlocks. Existing solutions face several problems such as a dead time, unintended prioritization or metastability. That is why we decided to create a new readout architecture named EDWARD i.e., Event Driven with Access and Reset Decoder. The EDWARD architecture gets rid of the earlier mentioned problems and mitigates the other ones. However, due to the use of logic circuits outside a standard cell library, which are hard to characterize, we were challenged to perform an additional transient analysis to validate the architecture. Here we show a methodology and the results of the simulations. Based on the results obtained we can confirm the functional correctness of the system and plan the optimization of operating conditions in order to achieve better performance. Our goal is to use the EDWARD architecture in the future radiation detectors to be built at Brookhaven National Laboratory.

47 OTHER INSTRUMENTATION↗

Characterizing Quality Factor of Niobium Resonators Using a Markov Chain Monte Carlo Approach

The next generation of radiation detectors in high precision Cosmology, Astronomy, and particle-astrophysics experiments will rely heavily on superconducting microwave resonators and kinetic inductance devices. Understanding the physics of energy loss in these devices, in particular at low temperatures and powers, is vital. We present a comprehensive analysis framework, using Markov Chain Monte Carlo methods, to characterize loss due to two-level system in concert with quasi-particle dynamics in thin-film Nb resonators in the GHz range.

MKID↗

Commissioning and field tests of a van-mounted system for the detection of radioactive sources and Special Nuclear Material

MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-step annealing to remove Te secondary-phase defects in CdZnTe while preserving the high electrical resistivity

We report the presence of Te secondary-phase defects (i.e., Te inclusions and Te precipitates) is a major factor limiting the performance of CdZnTe (CZT) X- and gamma-ray radiation detectors. We find that Te secondary-phase defects in CZT crystals can be removed through post-growth, two-step annealing without creating new trapping centers (i.e., prismatic punching defects). Two-step annealing (with the first in a Cd pressure and the second one in a Te pressure) was demonstrated to be effective in removing the Te secondary-phase defects, while preserving the electrical resistivity of the CZT detector. The first step involves annealing of semi-insulating CZT under a Cd overpressure at 700/600 °C (CZT/Cd) for 24 hours, which completely eliminated the Te-rich secondary-phase defects (Te inclusions). However, it resulted in a lower resistivity of the samples (down to 2 × 10 4-6 Ω·cm). A subsequent annealing step involves processing CZT under a Te ambient condition at 540/380 °C (CZT/Te) for 120 hours, which restored the crystal’s resistivity to 6.4 × 10 10 Ω·cm without creating new Te secondary-phase defects. However, Te inclusions reappeared in the case of unnecessarily long Te ambient annealing. Finally, pulse height spectra taken with the two-step annealed CZT detectors showed improved detector performance due to a reduced concentration and size of Te secondary-phase defects.

36 MATERIALS SCIENCE↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

Development of ML FPGA Filter for Particle Identification and Tracking in Real Time

Real-time data processing is a frontier field in experimental particle physics. Machine Learning methods are widely used and have proven to be very powerful in particle physics. The growing computational power of modern FPGA boards allows us to add more sophisticated algorithms for real time data processing. Many tasks could be solved using modern Machine Learning (ML) algorithms which are naturally suited for FPGA architectures. The FPGA-based machine learning algorithm provides an extremely low, sub-microsecond, latency decision and makes information-rich data sets for event selection. We report work has started to evaluate an FPGA based Machine Learning (ML) algorithm for a real-time particle identification and tracking with Transition Radiation Detector (TRD) and e/m calorimeter. The first target is the GlueX experiment, with a plan to build a TRD based on GEM technology. GlueX trigger latency is 3.3 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal conductivity studies of CdZnTe with varying Te excess

Cadmium Zine Telluride (CZT) has been extensively studied as a room temperature semiconductor gamma radiation detector. CZT continues to show promise as a bulk and pixelated gamma spectrometer with less than one percent energy resolution; however the fabrication costs are high. Improved yields of high quality, large CZT spectroscopy grade crystals must be achieved. CZT is grown by the Traveling Heater Method (THM) with a Te overpressure to account for vaporization losses. This procedure creates Te rich zones. During growth, boules will often cleave limiting the number of harvestable crystals. As a result, crystal growth parameter optimization was evaluated by modeling the heat flow within the system. Interestingly, Cadmium Telluride (CdTe) is used as a thermal conductivity surrogate in the absence of a thorough study of the CZT thermal properties. The current study has measured the thermal conductivity of CZT pressed powders with varying Te concentrations from 50-100% over 25-800°C to understand the variation in this parameter from CdTe. Cd0.9Zn0.1Te1.0 is the base CZT (designated 50%). CZT exhibits a thermal conductivity of nearly 1 W/mK, an order of magnitude greater than CdTe. Lastly, the thermal conductivity decreased with increasing Te concentration.

36 MATERIALS SCIENCE↗

Mechanisms contributing to dark current across metal/CdMnTe/metal structures

The study of the electro-physical properties of n-type semi-insulating crystals of indium-doped Cd(Mn)Te solid solution with a resistivity ~ (4÷5)×10 10 Ohm×cm at T = 300 K was carried out. The structures both with an ohmic (In/Cd(Mn)Te/In) contacts and with the rectifying (Ni/Cd(Mn)Te/In) contact were fabricated. It was found that for the Ni/Cd(Mn)Te/In structure, the main mechanisms of charge transport were: the generation currents in the space-charge region, space-charge limited currents (SCLC) at high voltages, and the Ohm’s law was valid only on initial section the of the volt-ampere characteristics (I-VC). Calculation of the generation current dependence on the voltage according to the theory of Sah-Noyce-Shockley was carried out. For the In/Cd(Mn)Te/In structure it was observed the I-VC initial section, where the Ohm’s law was implemented, and the SCLCs with the participation of deep centers (traps) in semiinsulating crystal - at greater voltages. The concentration of deep centers (Nt ~ 7.4×10 10 cm -3 ) responsible for the trap mechanism in SCLC In/Cd(Mn)Te/In structures was calculated. The energy position Et of the deep levels was determined (provided that the energy was calculated from the valence band edge, Et = 0.89÷0.9 eV). It was discussed and grounded the assumption that SCLC was the main mechanism limiting the operating voltages and, consequently, the use of Cd(Mn)Te-based ionizing-radiation detectors with ohmic contacts.

36 MATERIALS SCIENCE↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based autoradiography have adequate sensitivity to detect the tumor burden needed for genetic profiling in 18G core needle biopsies. Supported in part through the NIH/NCI Cancer Center Support Grant P30 CA008748 and by a sponsored research agreement with Biospace Lab S.A.

60 APPLIED LIFE SCIENCES↗