Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Pretreatment Quality of Life Predicts for Locoregional Control in Head and Neck Cancer Patients: A Radiation Therapy Oncology Group Analysis

Purpose: To analyze the prospectively collected health-related quality-of-life (HRQOL) data from patients enrolled in two Radiation Therapy Oncology Group randomized Phase III head and neck cancer trials (90-03 and 91-11) to assess their value as an independent prognostic factor for locoregional control (LRC) and/or overall survival (OS). Methods and Materials: HRQOL questionnaires, using a validated instrument, the Functional Assessment of Cancer Therapy-Head and Neck (FACT-H and N), version 2, were completed by patients before the start of treatment. OS and LRC were the outcome measures analyzed using a multivariate Cox proportional hazard model. Results: Baseline FACT-H and N data were available for 1,093 patients and missing for 417 patients. No significant difference in outcome was found between the patients with and without baseline FACT-H and N data (p = 0.58). The median follow-up time was 27.2 months for all patients and 49 months for surviving patients. Multivariate analyses were performed for both OS and LRC. Beyond tumor and nodal stage, Karnofsky performance status, primary site, cigarette use, use of concurrent chemotherapy, and altered fractionation schedules, the FACT-H and N score was independently predictive of LRC (but not OS), with p = 0.0038. The functional well-being component of the FACT-H and N predicted most significantly for LRC (p = 0.0004). Conclusions: This study represents, to our knowledge, the largest analysis of HRQOL as a prognostic factor in locally advanced head and neck cancer patients. The results of this study have demonstrated the importance of baseline HRQOL as a significant and independent predictor of LRC in patients with locally advanced head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-mixing detection of backscattered radiation in a single-mode erbium fibre laser for Doppler spectroscopy and velocity measurements

We report an experimental study of the self-mixing effect in a single-mode multifrequency erbium fibre laser when radiation backscattered from an external moving object arrives at its cavity. To eliminate resulting chaotic pulsations in the laser, we have proposed a technique for suppressing backscattered radiation through the use of multimode fibre for radiation delivery. The multifrequency operation of the laser has been shown to lead to strong fluctuations of the amplitude of the Doppler signal and a nonmonotonic variation of the amplitude with distance to the scattering object. In spite of these features, the self-mixing signal was detected with a high signal-to-noise ratio (above 10{sup 2}) when the radiation was scattered by a rotating disc, and the Doppler frequency shift, evaluated as the centroid of its spectrum, had high stability (0.15%) and linearity relative to the rotation rate. We conclude that the self-mixing effect in this type of fibre laser can be used for measuring the velocity of scattering objects and in Doppler spectroscopy for monitoring the laser evaporation of materials and biological tissues. (control of laser radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stronger Efforts are Needed to Improve the Control of Radioactive Sources: An IAEA Perspective

High activity radioactive sources provide great benefit to humanity through their utilization in agriculture, industry, medicine, research and education, and the vast majority is used in well-controlled environments. None-the-less, control has been lost over a small fraction of those sources resulting in accidents of which some had serious - even fatal - consequences. In order to improve the existing situation, concerted national and international efforts are needed and, to some degree, are being implemented to strengthen the safety and security of sources in use, as well as to improve the control of disused sources located at numerous facilities throughout the world. More efforts must also be made to identify, recover, and bring into control vulnerable and orphan sources. The IAEA has been involved in efforts to bring about better control of radioactive sources for many years but since the events of September 2001 the amount of effort put into this area has increased considerably. This paper highlights IAEA work in this regard. This paper also discusses in some detail the overall nature of the problem with regards to disused sources and points out how there is still much to do in both improving the existing situation and ensuring the sustainability of control over radioactive sources for the future. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Anaerobic digestion of organic fraction of municipal solid waste combining two pretreatment modalities, high temperature microwave and hydrogen peroxide

Highlights: Black-Right-Pointing-Pointer Microwave and H{sub 2}O{sub 2} pretreatment were studied to enhance anaerobic digestion of organic waste. Black-Right-Pointing-Pointer The whole waste pretreated at 115 Degree-Sign C or 145 Degree-Sign C had the highest biogas production. Black-Right-Pointing-Pointer Biogas production of the whole waste decreased at 175 Degree-Sign C due to formation of refractory compounds. Black-Right-Pointing-Pointer Pretreatment to 145 Degree-Sign C and 175 Degree-Sign C were the best when considering only the free liquid fraction. Black-Right-Pointing-Pointer H{sub 2}O{sub 2} pretreatment had a lag phase and the biogas production was not higher than MW pretreated samples. - Abstract: In order to enhance anaerobic digestion (AD) of the organic fraction of municipal solid waste (OFMSW), pretreatment combining two modalities, microwave (MW) heating in presence or absence of hydrogen peroxide (H{sub 2}O{sub 2}) were investigated. The main pretreatment variables affecting the characteristics of the OFMSW were temperature (T) via MW irradiation and supplemental water additions of 20% and 30% (SWA20 and SW30). Subsequently, the focus of this study was to evaluate mesophilic batch AD performance in terms of biogas production, as well as changes in the characteristics of the OFMSW post digestion. A high MW induced temperature range (115-175 Degree-Sign C) was applied, using sealed vessels and a bench scale MW unit equipped with temperature and pressure controls. Biochemical methane potential (BMP) tests were conducted on the whole OFMSW as well as the liquid fractions. The whole OFMSW pretreated at 115 Degree-Sign C and 145 Degree-Sign C showed 4-7% improvement in biogas production over untreated OFMSW (control). When pretreated at 175 Degree-Sign C, biogas production decreased due to formation of refractory compounds, inhibiting the digestion. For the liquid fraction of OFMSW, the effect of pretreatment on the cumulative biogas production (CBP) was more pronounced for SWA20 at 145 Degree-Sign C, with a 26% increase in biogas production after 8 days of digestion, compared to the control. When considering the increased substrate availability in the liquid fraction after MW pretreatment, a 78% improvement in biogas production vs. the control was achieved. Combining MW and H{sub 2}O{sub 2} modalities did not have a positive impact on OFMSW stabilization and enhanced biogas production. In general, all samples pretreated with H{sub 2}O{sub 2} displayed a long lag phase and the CBP was usually lower than MW irradiated only samples. First order rate constant was calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Output energy parameters of a KULON-10Cu-UV laser

The output energy parameters of an industrial KULON copper vapour laser equipped with a nonlinear frequency converter based on DKDP and BBO crystals are studied. The average and peak powers, as well as the energies and pulse durations of radiation at wavelengths of 510, 578, 255, 271, and 289 nm, are measured in the regime of high-speed pulse modulation, which is used in lasers of this series. The maximum average power was 420 mW at a wavelength of 271 nm (DKDP) and 350 and 110 mW at 255 and 289 nm, respectively (BBO). It is experimentally shown that the average energy characteristics of UV radiation can be controlled on-line by changing the pulse repetition rate of the laser. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical investigation of multichannel laser beam phase locking in turbulent atmosphere

The efficiency of coherent multichannel beam combining under focusing through a turbulent medium on a target in the cases of phase conjugation and target irradiation in the feedback loop is investigated numerically in various approximations. The conditions of efficient focusing of multichannel radiation on the target are found. It is shown that the coherent beam combining with target irradiation in the feedback loop, which does not require a reference beam and wavefront measurements, is as good as the phase conjugation approach in the efficiency of focusing. It is found that the main effect of focusing is provided by properly chosen phase shifts in the channels, whereas taking into account local wavefront tip tilts weakly affects the result. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupling of the radiative, convective, and surface fluxes over the equatorial Pacific

An idealized energy-balance model for a closed tropical circulation is first presented to illustrate the coupling between the net tropospheric cooling, the surface fluxes, and the mean subsidence away from the precipitation zones. Then a one-dimensional diagnostic model and a radiation model with boundary layer clouds are combined to explore this coupling for a specific region, using mean sounding data over the tropical Pacific. The radiatively driven subsidence rate at the top of the convective boundary layer is approximately 35 mb/day and is largely independent of boundary layer cloud fraction. The sensitivity of the corresponding convective heat flux profiles to the mass divergence profile and cloud fraction within the boundary layer is explored. Reasonable assumptions give realistic surface sensible and latent heat fluxes for this region of approximately 10 and 130 W/sq m. The paper illustrates the important background climatic control of the radiation field on the tropical surface fluxes.

Ridgway, W.↗

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optomechanical interaction in fibre lasers with micro-optomechanical resonance structures

We report the results of studies of fibre lasers with passive modulators based on light-excited micro-optomechanical resonance structures (micro-oscillators). It is shown that in fibre lasers based on active fibres doped with rare-earth elements (Er, Er/Yb, Yb, Nd), the optomechanical interaction of laser radiation with micro-oscillators of various types (fibre-optic, microvolume) leads to self-oscillations of the characteristics of laser radiation at frequencies of relaxation oscillations and intermode beats synchronised with the frequencies of elastic eigenoscillations of micro-oscillators. It is found that in an ultra-long erbium – ytterbium fibre laser with a nonlinear mirror based on a microcantilever, laser photothermal excitation of the second mode of elastic transverse oscillations of the microcantilever makes it possible to perform passive mode locking exclusively due to Q-switching of the laser cavity. Pulsed lasing with a controlled repetition rate (∼76 kHz), a pulse duration of 2 – 5 μs and an output energy of 0.1 μJ per pulse is implemented. Based on a simplified physical model of the indicated fibre lasers with micro-oscillators, we have developed an approximate mathematical model describing the regimes of passive mode locking of fibre lasers with micro-oscillators that play the role of mirrors with a nonlinear reflection coefficient in the laser cavity. The prospects for the development and application of the considered laser systems are discussed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Influence of The Galilean Satellites on Radio Emissions From The Jovian System

The Galilean satellites influence radio emissions from the Jovian system in a variety of ways. The best and most familiar example of these is the Io control of decametric radiation discovered in 1964 by Bigg. Voyager observations of broadband kilometric radiation revealed a low-latitude shadow zone cast by the Io torus at frequencies between a few tens of kHz and about 1 MHz. Voyager also discovered narrowband kilometric radio emissions emanating from the outer edge of the torus. In this paper we will discuss expansions in the suite of satellite influences based on new observations by Galileo. These include the discovery of Ganymede's magnetosphere and evidence of radio emissions generated via mode conversion from upper hybrid waves in the frequency range of about 20 - 100 kHz. There is evidence that Ganymede may control some of the hectometric or low-frequency decametric radio emissions based on occultation measurements and statistical studies of radio emission occurrence as a function of Ganymede phase. Direction-finding measurements in the vicinity of Io suggest that a portion of the hectometric emissions may be generated near the lo L-shell. A rotationally modulated attenuation band in the hectometric emission appears to be the result of scattering at or near the Io L-shell where the waves propagate nearly parallel to the magnetic field. There is even a tantalizing hint of a Europa connection to the source of narrowband kilometric radiation.

Kurth, W. S.↗

Layer-Dependent Bit Error Variation in 3-D NAND Flash Under Ionizing Radiation

In this paper, we studied the total ionization dose (TID) effects on the multilevel-cell (MLC) 3-D NAND flash memory using Co-60 gamma radiation. We found a significant page-to-page bit error variation within a physical memory block of the irradiated memory chip. Our analysis showed that the origin of the bit error variation is the unique vertical layer-dependent TID response of the 3-D NAND. We found that the memory pages located at the upper and lower layers of the 3-D stack show higher fails compared to the middle-layer pages of a given memory block. We confirmed our findings by comparing radiation response of four different chips of the same specification. In addition, we compared the TID response of the MLC 3-D NAND with that of the 2-D NAND chip, which showed less page-to-page variation in bit error within a given memory block. We discuss the possible application of our findings for the radiation-tolerant smart memory controller design.

3-D NAND flash↗

Effects of Probiotic Lactobacillus Casei DN-114 001 in Prevention of Radiation-Induced Diarrhea: Results From Multicenter, Randomized, Placebo-Controlled Nutritional Trial

Purpose: To determine whether a probiotic drink containing Lactobacillus casei DN-114 001 reduces the incidence of radiation-induced diarrhea in patients with gynecologic cancer. Methods and Materials: Patients who were undergoing pelvic radiotherapy (45-50 Gy, conventional fractionation) for either cervical carcinoma (radiotherapy and weekly cisplatin) or endometrial adenocarcinoma (postoperative radiotherapy) were randomly assigned to a probiotic drink or placebo, in a double-blind fashion. The probiotic drink consisted of liquid yogurt containing L. casei DN-114 001 at 10{sup 8} CFU/g. The patients recorded the daily the number of bowel movements and scored the stool consistency using the Bristol scale. Diarrhea was graded weekly according the Common Toxicity Criteria system. The primary endpoint was to reduce the incidence of diarrhea, defined by a Common Toxicity Criteria Grade of 2 or greater or the need for loperamide. Results: A total of 85 patients were enrolled. Grade 2 or greater diarrhea and/or the use of loperamide was observed in 24 of 41 patients in the placebo group and 30 of 44 in the probiotic group (p = 0.568). No differences were found in the median time to the presentation of the primary endpoint. Probiotic intervention had a significant effect on stool consistency (p = 0.04). The median time for patients to present with Bristol scale stools of Type 6 or greater was 14 days for patients receiving the probiotic drink vs. 10 days for those receiving placebo. Conclusion: Nutritional intervention with the probiotic drink containing L. casei DN-114 001 does not reduce the incidence of radiation-induced diarrhea as defined by a Common Toxicity Criteria Grade 2 or greater. However, it had a significant effect on stool consistency as measured by the Bristol scale.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mode-selective thermal radiation from a microparticle

We experimentally demonstrate that thermal radiation from a micron-sized dielectric particle depends sensitively on its size and shape through the cavity quantum-electrodynamic effect. Our laser trapping technique levitated a high-temperature microsphere of Al{sub 2}O{sub 3} and enabled emission spectroscopy of the single particle. As the particle becomes smaller, a blackbodylike spectrum turns into a spectrum dominated by multiple peaks resonant with whispering gallery modes of the spherical resonator. The observed sharp frequency selectivity is applicable to spectral control of thermal radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NMR-based Metabolomics Analysis of Liver from C57BL/6 Mouse Exposed to Ionizing Radiation

The health effects of exposing to ionizing radiation are attracting great interest in the space exploration community and patients considering radiotherapy. However, the impact to metabolism after exposure to high dose radiation has not yet been clearly defined in livers. In the present study, 1H nuclear magnetic resonance (NMR) based metabolomics combined with multivariate data analysis are applied to study the changes of metabolism in the liver of C57BL/6 mouse after whole body exposure to either gamma (3.0 and 7.8 Gy) or proton (3.0 Gy) radiation. Principal component analysis (PCA) and orthogonal projection to latent structures analysis (OPLS) are employed for classification and identification of potential biomarkers associated with gamma and proton irradiation. The results show that the radiation exposed groups can be well separated from the control group. At the same radiation dosage, the group exposed to proton radiation is well separated from the group exposed to gamma radiation, indicating different radiation sources induce different alterations based on metabolic profiling. Common to both gamma and proton radiation at the high radiation doses studied in this work, compared with the control groups the concentrations of choline, O-phosphocholine and trimethylamine N-oxide are decreased statistically, while those of glutamine, glutathione, malate, creatinine, phosphate, betaine and 4-hydroxyphenylacetate are statistically and significantly elevated after exposure to radiation. Since these altered metabolites are associated with multiple biological pathways, the changes suggest that the exposure to radiation induce abnormality in multiple biological pathways. In particular, metabolites such as 4-hydroxyphenylacetate, betaine, glutamine, choline and trimethylamine N-oxide may be good candidates of pre-diagnose biomarkers for ionizing radiation in liver.

Xiao, Xiongjie↗

SU-F-J-54: Towards Real-Time Volumetric Imaging Using the Treatment Beam and KV Beam

Purpose: Existing real-time imaging uses dual (orthogonal) kV beam fluoroscopies and may result in significant amount of extra radiation to patients, especially for prolonged treatment cases. In addition, kV projections only provide 2D information, which is insufficient for in vivo dose reconstruction. We propose real-time volumetric imaging using prior knowledge of pre-treatment 4D images and real-time 2D transit data of treatment beam and kV beam. Methods: The pre-treatment multi-snapshot volumetric images are used to simulate 2D projections of both the treatment beam and kV beam, respectively, for each treatment field defined by the control point. During radiation delivery, the transit signals acquired by the electronic portal image device (EPID) are processed for every projection and compared with pre-calculation by cross-correlation for phase matching and thus 3D snapshot identification or real-time volumetric imaging. The data processing involves taking logarithmic ratios of EPID signals with respect to the air scan to reduce modeling uncertainties in head scatter fluence and EPID response. Simulated 2D projections are also used to pre-calculate confidence levels in phase matching. Treatment beam projections that have a low confidence level either in pre-calculation or real-time acquisition will trigger kV beams so that complementary information can be exploited. In case both the treatment beam and kV beam return low confidence in phase matching, a predicted phase based on linear regression will be generated. Results: Simulation studies indicated treatment beams provide sufficient confidence in phase matching for most cases. At times of low confidence from treatment beams, kV imaging provides sufficient confidence in phase matching due to its complementary configuration. Conclusion: The proposed real-time volumetric imaging utilizes the treatment beam and triggers kV beams for complementary information when the treatment beam along does not provide sufficient confidence for phase matching. This strategy minimizes the use of extra radiation to patients. This project is partially supported by a Varian MRA grant.

60 APPLIED LIFE SCIENCES↗

Generation of frequency-tunable pulsed terahertz radiation by a Cr : forsterite laser system with an acoustooptical control of the pulse temporal profile

We report the experimental results on generating pulsed terahertz (THz) radiation, frequency-tunable within the range 0.5−2 THz. The THz pulse generation was implemented using the method of optical rectification of femtosecond laser pulses in the nonlinear organic crystal OH1. The frequency tuning of the THz radiation was provided by adaptive phase – amplitude modulation of the pump pulses from the Cr : forsterite laser system with a radiation wavelength of 1230 nm using the acoustooptical dispersion delay line. (paper)

42 ENGINEERING↗

Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure

Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.

leakage↗