Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Interfacial Unit-Dependent Catalytic Activity for CO Oxidation over Cerium Oxysulfate Cluster Assemblies

Atomically precise cerium oxo clusters offer a platform to investigate structure–property relationships that are much more complex in the ill-defined bulk material cerium dioxide. We investigated the activity of the MCe 70 torus family (M = Cd, Ce, Co, Cu, Fe, Ni, and Zn), a family of discrete oxysulfate-based Ce 70 rings linked by monomeric cation units, for CO oxidation. CuCe 70 emerged as the best performing MCe 70 catalyst among those tested, prompting our exploration of the role of the interfacial unit on catalytic activity. Temperature-programmed reduction (TPR) studies of the catalysts indicated a lower temperature reduction in CuCe 70 as compared to CeCe 70 . In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) indicated that CuCe 70 exhibited a faster formation of Ce 3+ and contained CO bridging sites absent in CeCe 70 . Isothermal CO adsorption measurements demonstrated a greater uptake of CO by CuCe 70 as compared to CeCe 70 . The calculated energies for the formation of a single oxygen defect in the structure significantly decreased with the presence of Cu at the linkage site as opposed to Ce. Furthermore, this study revealed that atomic-level changes in the interfacial unit can change the reducibility, CO binding/uptake, and oxygen vacancy defect formation energetics in the MCe 70 family to thus tune their catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Goniospectrometric properties of a white standard

Reflection spectroscopy is one of the fundamental tools in planetary remote sensing. Most of the laboratory work is done in terms of bidirectional reflectance R in the wavelength range of reflected sunlight (250 nm - 2500 nm). Bidirectional reflectance R is defined as the radiance of a surface relative to the radiance of an ideal Lambertian reflector, identically illuminated (radiance coefficient). For quantitative laboratory work the absolute scale of R has to be known. In addition, for many purposes it is necessary to know the dependence of R from phase angle for a large range of geometries. In many cases, this can only be achieved if the goniospectrometric properties of the white standard that is used are known with high precision. For a long time Halon has been used as a white standard by most laboratories. Because Halon is no more available we have now analyzed the goniospectrometric properties of Spectralon SRS-99 with the DLR-goniospectrometer.

Oehler, A.↗

Realization of a high luminosity muon beam at the Jefferson Lab

The proton is the major component of the visible matter of our universe, so being able to determine its fundamental properties, such as its charge radius, is of vital importance. In recent years, several experiments have been performed for the accurate measurement of the proton radius with different experimental techniques. The main and most common are based on two different techniques: ep scattering and Lamb shift spectroscopy of regular hydrogen atoms. The latter can also be performed on muonic hydrogen atoms with a significant improvement in accuracy. Recent measurements that use this method have highlighted a discrepancy between the results obtained with the diffusion of electrons and those obtained with the spectroscopic technique leading to the so-called ?proton radius puzzle?. The explanation of why this difference between the measured values exists is still a matter of discussion. The last attempt to address the puzzle was the PRad Experiment. It was performed with a unique experimental setup that gave the scientists an excellent control on the systematic errors that are usually present in electron-proton scattering experiments. This has significantly increased the precision of the measurement, bringing it in the same area as the spectroscopic ones done on muonic hydrogen atoms, which are considered the most precise. However, to solve the puzzle once and for all, even more precise electron scattering measurements are needed. Alternatively, new methods can be used, such as eg. muon-proton scattering at low transferred momenta in order to lower the systematic errors that comes with the measurement. This thesis tries to address this problem by studying the set up of an intense muon beam at the Jefferson Laboratory (JLab) that can be used to carry out a high-precision m ? p scattering experiment. Using Montecarlo simulations I studied the muon production resulting from the interaction of the primary electron beam with the beam-dump at JLab Hall-A. The simulations were performed using the FLUKA package via the FLAIR graphical interface. In this study, I modified an existing geometry (built for the ?Beam Dump eXperiment?) and performed several studies in order to optimize the muon beam parameters. In order to estimate the beam intensity, I studied the muon generation and transportation through the concrete bunker surrounding the Hall-A beam-dump. Detailed studies on muon attenuation and dispersion at different depth allowed me to track the beam profile in space and momentum as a function of the distance from the beam-dump. Last, but not least, I studied a possible tagging system for the muon beam. The tagging system will allow us to know with good precision (O(1=1000)) the energy of each muon of the beam. Based on the results obtained, I created an event generator that incorporates the detailed description of the muon beam (energy, position, emittance) useful to define and optimize the experimental setup for a future measurement of the proton radius at the JLab.

Fulci, Antonino↗

Characterization of mApple as a Red Fluorescent Protein for Cryogenic Single-Molecule Imaging with Turn-Off and Turn-On Active Control Mechanisms

Single-molecule superresolution microscopy is a powerful tool for the study of biological structures on size scales smaller than the optical diffraction limit. Imaging samples at cryogenic temperatures (77 K) reduces the quantum yield of photobleaching for many fluorescent labels, yielding localization precisions below 10 nm. Cryogenic imaging further enables correlation with cryogenic electron tomography. A key limitation in applying methods such as PALM and STORM to samples maintained at 77 K is the limited number of fluorophores known to undergo efficient turn-on and turn-off mechanisms necessary to control the sparsity of active emitters. Here we find that mApple, a red-emitting fluorescent protein, undergoes a novel turn-off mechanism in response to simultaneous illumination with two colors of light. This turn-off mechanism enables localization of many individual molecules in initially bright samples, but the final density of localizable emitters is limited by relatively inefficient turn-on (photoactivation). Bulk excitation and emission spectroscopy shows that mApple has access to two distinct emissive states as well as dark states accessible optically or through changes in pH. The bright and stable emission of mApple enables widefield collection of single-molecule emission spectra, which highlight the complex nature and environmental sensitivity of states observed in red fluorescent proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Percolated Ionic Aggregate Morphologies and Decoupled Ion Transport in Precise Sulfonated Polymers Synthesized by Ring-Opening Metathesis Polymerization

Here, we describe a set of precise single-ion conducting polymers that form self-assembled percolated ionic aggregates in glassy polymer matrices and have decoupled transport of metal cations. These precise single-ion conductors (SICs), synthesized by a scalable ring-opening metathesis polymerization, consist of a polyethylene backbone with a sulfonated phenyl group pendant on every fifth carbon and are fully neutralized by a counterion X + (Li + , Na + , or Cs + ). Experimental X-ray scattering measurements and fully atomistic molecular dynamics (MD) simulations are in good agreement. The MD simulations show that the ionic groups nanophase separate from the polymer backbone to form percolating ionic aggregates. Using graph theory, we find that within the Li + - and Na + -neutralized polymers the percolated aggregates exhibit planar and ribbon-like configurations at intermediate length scales, while the percolated aggregates within the Cs + -neutralized polymers are more isotropic. Electrical impedance spectroscopy measurements show that the ionic conductivities exhibit Arrhenius behavior, with conductivities of 10 –7 to 10 –6 S/cm at 180 °C. In the MD simulations, the cations move between sulfonate groups in the percolated aggregates, larger ions travel further, and overall cations travel further than the polymer backbones, indicating a decoupled ion-transport mechanism. Thus, the percolated ionic aggregates in these polymers can serve as pathways to facilitate decoupled ion motion through a glassy polymer matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AuPd Nanoicosahedra: Atomic-Level Surface Modulation for Optimization of Electrocatalytic and Photocatalytic Energy Conversion

Modulation of bimetallic nanocatalysts with atomic precision would allow for significant increases in catalyst activity through the optimization of heteroatomic interplay. In practice, this level of control over homogeneously turning the heteroatomic states in the surface regions of catalysts remains a great challenge for practical applications requiring mass production. In this work, a one-step aqueous strategy for preparation of AuPd nanoicosahedra core–shell structures has been developed. By turning the molar ratio of Au and Pd precursors, the nanoicosahedra could be made with uniform core composition (Pd ~20%) and largely flexible surface compositions (Pd: 20–70%). Under model reactions of electrochemical ethanol oxidation (EOR) and 4-nitrophenol (4-NP) reduction, the Au 55 Pd 45 surface displayed superior activities. Here, x-ray absorption spectroscopy revealed that AuPd nanoicosahedra with Pd-poor surfaces (Au 79 Pd 21 and Au 60 Pd 40 ) maintain Au-like electronic structures while those with Pd-rich surfaces are more Pd-like. The Au 55 Pd 45 surface struck a delicate balance between the two extremes, leading to the optimal Au–Pd interplay for catalytic performance. Overall, the development of a one-step aqueous strategy for atomic-level control over bimetallic nanoparticle surface states is an important milestone for future advances in catalysis. Our findings in atomic-scale catalyst design will bring deep insights into the fields of nanosynthesis and heterogeneous catalysis, which will be beneficial for further scientific breakthroughs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring the Near-Surface Environment of Rh Single-Atom Catalysts for Selective CO 2 Hydrogenation

For this study, we used a combination of experimental spectroscopies, density functional theory calculations, and CO 2 hydrogenation studies to investigate the effects of modifying single-atom Rh 1 /TiO 2 catalysts with functionalized phosphonic acid monolayers. We found that the deposition of specific amine-functionalized ligands resulted in an ~8× increase in site-specific CO 2 reduction turnover frequency at 150 °C and a ~2× increase at 250 °C. On-stream stability also improved following ligand deposition. The effect of the modifier on reactivity was highly sensitive to the proximity of the amine functional group to the surface, which was controlled by adjusting the length of the phosphonic acid tail. Furthermore, deposition of alkyl phosphonic acids without an amine functional group resulted in blocked CO 2 adsorption and a near-complete loss of catalytic activity. Infrared spectroscopy studies suggested that the amine group provided binding sites for CO 2 that enabled hydrogenation when the amine was positioned near a Rh1 site. Phosphonic acid-modified catalysts also exhibited high selectivity to CO over the series product methane; the selectivity effect was traced to modification of the Rh1 sites to favor CO desorption. Phosphonic acid deposition resulted in 80–90% loss of accessible Rh1 sites, likely due to blocking by tail groups. However, even with the loss of sites, under low-temperature reaction conditions, the rates of CO 2 hydrogenation were improved with the coatings, indicating that the remaining sites are highly efficient. Organic functionalization of the supports for atomically dispersed catalysts offers the opportunity to precisely control the positioning of functional groups in the vicinity of a well-defined active site, potentially enabling an additional level of control over active site design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid spatial analysis of surrogate TRISO fuel particles using laser-induced breakdown spectroscopy image analysis

Laser-induced breakdown spectroscopy (LIBS) mapping enables rapid elemental and spatial analysis of solid samples. In this work, surrogate TRi-structural ISOtropic (TRISO) particles with various layers consisting of Zr, W, C, and Si were used to demonstrate the use of a new thickness measurement tool developed to analyze elemental images generated from LIBS maps. Zr particles with varying outer-layer thicknesses ranging from 16 to 32 μm were measured with scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) and LIBS with both a complementary metal-oxide-semiconductor (CMOS) detector and an intensified charged coupled device (ICCD) detector. LIBS maps of particles were completed using CMOS and ICCD spectrometers with effective spatial resolutions of 4 and 2 μm, respectively. The novel thickness measurement tool identified layer regions within a LIBS map and then identified the locations of the boundaries between these layers. The tool then generated up to 1000 random profiles stemming radially from the center region, which were used to measure the layer thickness/radius. This image analysis tool demonstrated LIBS's ability to provide values comparable with SEM-EDS (3.7% relative difference) along with a 95% reduction in measurement time. Furthermore, the precision of these measurements was on par with the SEM-EDS measurements at <15% relative standard deviation. Following the analysis of the Zr particles, W particles with increased complexity (e.g., five versus three layers) were analyzed using both the CMOS and ICCD spectrometers simultaneously. The spatial dimensions were extracted with an average relative difference of 2.7% and an average relative standard deviation of 9%.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

25 Siβ + -decay spectroscopy

Background: β-decay spectroscopy provides valuable information on exotic nuclei and a stringent test for nuclear theories beyond the stability line. Purpose: To search for new β-delayed protons and γ rays of 25 Si to investigate the properties of 25 Al excited states. Method: 25 Si β decays were measured by using the Gaseous Detector with Germanium Tagging system at the National Superconducting Cyclotron Laboratory. The protons and γ rays emitted in the decay were detected simultaneously. Here, a Monte Carlo method was used to model the Doppler broadening of 24 Mg γ-ray lines caused by nuclear recoil from proton emission. Shell-model calculations using two newly developed universal sd-shell Hamiltonians were performed. Results: The most precise 25Si half-life to date has been determined. A new proton branch at 724(4) keV and new proton-γ-ray coincidences have been identified. Three 24 Mg γ-ray lines and eight 25 Al γ-ray lines are observed for the first time in 25 Si decay. The first measurement of the 25 Si β-delayed γ-ray intensities through the 25 Al unbound states is reported. All the bound states of 25 Al are observed to be populated in the β decay of 25 Si. Several inconsistencies between the previous measurements have been resolved, and new information on the 25 Al level scheme is provided. An enhanced decay scheme has been constructed and compared to the mirror decay of 25 Na and the shell-model calculations. Conclusions: The measured excitation energies, γ-ray and proton branchings, log $ft$ values, and Gamow-Teller transition strengths for the states of 25 Al populated in the β decay of 25 Si are in good agreement with the shell model calculations, offering gratifyingly consistent insights into the fine nuclear structure of 25 Al.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

Structural Effects on Solubility and Crystallinity in Polyamide Ionomers

Although polyamides have been an industrial staple for decades, their solubility and processability remain limited due to the strong hydrogen bonding between amide groups. Here, we report a family of polyamides in which aryl rings, alkyl spacers, sulfonate groups, and amide linkages are regularly spaced along the polymer backbone, allowing us to probe the structural elements that affect processability. We accessed these polymers through a synthetic route based on an expanded diamine monomer and characterized them through a range of physical and spectroscopic techniques. Our results show that the combination of sulfonate groups with increased amide content results in highly soluble polymers, which can dissolve in polar solvents such as water, methanol, and N,N-dimethylformamide. Infrared spectroscopy on the solid polymers shows that the aliphatic amides engage in hydrogen bonding with the sulfonate groups, thus inhibiting ion aggregation, crystallization, and microphase separation. These findings expand the avenue to sulfonate-containing polyamide chemistry and provide design rules for the synthesis of more processable ionic polyamides.

amides↗

Domain coupling in activation of a family C GPCR

Abstract The G protein-coupled metabotropic glutamate receptors form homodimers and heterodimers with highly diverse responses to glutamate and varying physiological functions. We employ molecular dynamics, single-molecule spectroscopy and hydrogen–deuterium exchange to dissect the activation pathway triggered by glutamate. We find that activation entails multiple loosely coupled steps, including formation of an agonist-bound, pre-active intermediate whose transition to active conformations forms dimerization interface contacts that set efficacy. The agonist-bound receptor populates at least two additional intermediates en route to G protein-coupling conformations. Sequential transitions into these states act as ‘gates’, which attenuate the effects of glutamate. Thus, the agonist-bound receptor is remarkably dynamic, with low occupancy of G protein-coupling conformations, providing considerable headroom for modulation by allosteric ligands. Sequence variation within the dimerization interface, as well as altered conformational coupling in receptor heterodimers, may contribute to precise decoding of glutamate signals over broad spatial and temporal scales.

Biochemistry & Molecular Biology↗

Engineering of Exciton Spatial Distribution in CdS Nanoplatelets

Zinc-blende CdS nanoplatelets with atomically flat and very large {100} basal planes terminated solely by one type of element (either Cd or S atoms) are synthesized. Optical spectroscopy, X-ray diffraction, X-ray absorption, and transmission electron microscopy confirm that the surface structures of newly developed S-terminated CdS nanoplatelets are at least as well-defined as the original Cd-terminated nanoplatelets. Band gaps of the nanoplatelets are found to depend on not only the quantum-confined dimension (thickness) but also the nature of the surface termination. The facet structure dictates the packing of the ligands (carboxylate for Cd-terminated nanoplatelets and alkyl for S-terminated nanoplatelets), which causes a difference in the lattice strain and significantly affects the optical spectral width. Experimental and theoretical results reveal that engineering the exciton spatial distribution by the tailored synthesis of semiconductor nanocrystals with a precisely controlled surface structure is fully possible, which should open a new door for delivering the long-promised potential of semiconductor nanocrystals.

Cadmium sulfide↗

Parity-doublet coherence times in optically trapped polyatomic molecules

Polyatomic molecules provide complex internal structures that are ideal for applications in quantum information science, quantum simulation and precision searches for physics beyond the standard model. A key feature of polyatomic molecules is the presence of parity-doublet states. These structures, which generically arise from the rotational and vibrational degrees of freedom afforded by polyatomic molecules, are a powerful feature to pursue diverse quantum science applications. Linear triatomic molecules contain ℓ-type parity-doublet states in the vibrational bending mode, which are predicted to exhibit robust coherence properties. Here we report optically trapped CaOH molecules prepared in ℓ-type parity-doublet states and realize a bare qubit coherence time of $T$$^{*}_{2}$, which is longer than the 0.36 s lifetime of the bending mode. We suppress differential Stark shifts by cancelling ambient electric fields using molecular spectroscopy and characterize parity-dependent trap shifts, which are found to limit the coherence time. Furthermore, the parity-doublet coherence times achieved in this work are a defining milestone for the use of polyatomic molecules in quantum science.

Quantum information↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Scalable Layer-by-Layer Electrospray-Assisted Interfacial Polymerization: Enabling Large-Area Polyamide Membrane Fabrication

Layer-by-layer electrospray-assisted interfacial polymerization (LBL-EAIP) has recently been proposed as an alternative approach for fabricating polyamide membranes with precisely controlled thickness and polymerization degree, showing great potential for reverse osmosis (RO) membrane synthesis. In this article, we report a scale-up strategy for LBL-EAIP to enable its practical application in RO membrane manufacturing. A multi-jet electrospray apparatus was developed, and the device configuration and process parameters were carefully adjusted to produce polyamide-on-polyethersulfone thin film composite (TFC) membranes with consistently high salt rejection and water permeance across the membrane area. Specifically, an average 97.1% NaCl rejection from a 2000 ppm NaCl feed was achieved with an area-to-area deviation of 1%, along with a deionized water permeance of 0.90 ± 0.11 LMH/bar at 15 bar feed pressure. In addition, a Fourier-transform infrared spectroscopy (FTIR)-based analytical method was developed for semi-quantitative assessment of membrane thickness and compositional uniformity, enabling rapid mapping of film microstructure and chemical variations. This work provides a pathway to scale up LBL-EAIP technology, bridging the gap between laboratory-scale innovation and industrial-scale manufacturing.

Feng, Yue (ORCID:0000000221343980)↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

On the Assessment and Uncertainty of Atmospheric Trace Gas Burden Measurements with High Resolution Infrared Solar Occultation Spectra from Space by the ATMOS Experiment

The Atmospheric Trace Molecule Spectroscopy (ATMOS) instrument is a high resolution Fourier transform spectrometer that measures atmospheric composition from low Earth orbit with infrared solar occultation sounding in the limb geometry. Following an initial flight in 1985, ATMOS participated in the Atmospheric Laboratory for Applications and Science (ATLAS) 1, 2, and 3 Space Shuttle missions in 1992, 1993, and 1994 yielding a total of 440 occultation measurements over a nine year period. The suite of more than thirty atmospheric trace gases profiled includes CO2, O3, N2O, CH4, H2O, NO, NO2, HNO3, HCl, HF, ClONO2, CCl3F, CCl2F2, CHF2Cl, and N2O5. The analysis method has been revised throughout the mission years culminating in the 'version 2' data set. The spectroscopic error analysis is described in the context of supporting the precision estimates reported with the profiles; in addition, systematic uncertainties assessed from the quality of the spectroscopic database are described and tabulated for comparisons with other experiments.

Abrams, M. C.↗