Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Customer-Focused Key Performance Indicators for Electric Vehicle Charging

To systematically improve the public charging experience, EV charging industry stakeholders need to define and measure it precisely. Many stakeholders currently measure aspects of the charging experience, but they typically employ metrics that are either operational in nature, such as charger uptime and mean time between failures, or composite customer satisfaction indices. To improve the customer experience most effectively, the industry needs metrics that define the charging experience from the perspective of the customer, not business operations. Furthermore, industry practitioners need granular metrics to know what specific aspects of the charging experience need improvement. This report defines such customer-focused metrics, called key performance indicators (KPIs).

33 ADVANCED PROPULSION SYSTEMS↗

Customer-Focused Key Performance Indicators for Electric Vehicle Charging

To systematically improve the public charging experience, EV charging industry stakeholders need to define and measure it precisely. Many stakeholders currently measure aspects of the charging experience, but they typically employ metrics that are either operational in nature, such as charger uptime and mean time between failures, or composite customer satisfaction indices. To improve the customer experience most effectively, the industry needs metrics that define the charging experience from the perspective of the customer, not business operations. Furthermore, industry practitioners need granular metrics to know what specific aspects of the charging experience need improvement. This report defines such customer-focused metrics, called key performance indicators (KPIs).

33 - ADVANCED PROPULSION SYSTEMS↗

ChargeX KPIs Transition to SAE

To systematically improve the public charging experience, EV charging industry stakeholders need to define and measure it precisely. Many stakeholders currently measure aspects of the charging experience, but they typically employ metrics that are either operational in nature, such as charger uptime and mean time between failures, or composite customer satisfaction indices. To improve the customer experience most effectively, the industry needs metrics that define the charging experience from the perspective of the customer, not business operations. Furthermore, industry practitioners need granular metrics to know what specific aspects of the charging experience need improvement. This presentation gives an overview of the key performance indicators (KPIs) defined by the ChargeX Consortium.

33 ADVANCED PROPULSION SYSTEMS↗

237 Np Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 237 Np. Fission was induced in a NpO 2 (NO 3 ) target using the Godiva IV critical assembly in burst mode. The irradiated sample was transferred to a high-resolution γ-ray detection setup within 50 minutes. γ-ray list mode data was collected from 50 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. Finally, the initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision γ-ray branching ratio measurements for long-lived fission products of importance to nuclear-security applications (TAMU Annual Report 2020)

Continuing with our effort of precisely measuring the branching ratios for long-lived fission products we have collected and measured two radiopure ¹⁵⁶Eu samples. The samples were collected on thin (40 μg/cm²) carbon-foil backings using a low-energy mass-separated beam of A = 156 fission products from CARIBU at Argonne National Laboratory. During collection, a HPGe detector was used to continuously monitor the implantation rate by detecting the characteristic γ rays emitted following the β decay of the shorter-lived fission products. The first sample had measured activity of 375 Bq while the second one had an activity of 700 Bq. The implanted samples were then shipped to Texas A&M University for measurement of the subsequent decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗

Quantum metrology timing limits of the Hong-Ou-Mandel interferometer and of general two-photon measurements

We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case, we consider the use of two-photon measurements using photons with variable bandwidths and frequency correlations. When the photon bandwidths are not equal, maximizing the measurement precision involves a trade-off between high interference visibility and strong frequency anticorrelations, with the optimal precision occurring when the photons share non-maximal frequency anticorrelations. We show that a generalized measurement has precision limits that are qualitatively similar to those of the HOM measurement whenever the generalized measurement is insensitive to the net delay of both photons. Finally, by examining the performance of states with more general frequency distributions, our analysis allows for engineering of the joint spectral amplitude for use in realistic situations, in which both photons may not have ideal spectral properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Analysis of Unpolarised p+p¿ Photoproduction with the GlueX Experiment

This thesis presents measurements of spin-density matrix elements in unpolarised p+p? photoproduction on a proton target. The dominant resonance contribution to the dipion system is the r(770) meson. Due to the large production cross section for this resonance, a valid comparison can be made between the obtained final results and r(770) spin-density matrix elements measured previously with other experiments. The measurement was performed over the 3:0 ? 11:6 GeV beam energy regime, which is a more extensive energy range than has ever been studied previously for the r(770). Results were obtained by analysing data from the GlueX experiment based at Jefferson Lab. Extended maximum likelihood fits were applied to extract three spin-density matrix elements using Markov chain Monte Carlo based parameter estimations. This was performed using various binning configurations to probe the energy, mass, and four-momentum transfer dependence of the determined physics observables. Spin-density matrix elements are shown to be consistent with the model of s-channel helicity conservation at low ?t. The effects of pomeron and f2 exchanges are clearly visible in the energy dependence of the measured observables. These observations provide valuable insights into the relative strengths of both processes as a function of the photon energy, and may enable theorists to disentangle the f2=P coupling ratio. Spin-density matrix elements are seen to be highly dependent on the reconstructed resonance mass. This observation is likely to be a result of non-resonant S-wave background processes, and emphasises the need for a more detailed model of the p+p? angular distribution that considers all of the competing angular momentum components that contribute to the measured final state. The statistical precision of measurements performed for this thesis surpass what was achievable in previous studies of the r(770) by several orders of magnitude. Studies of the energy and four-momentum transfer dependence, and insights into the effects of non r(770) background contributions provide valuable input for production models. This will help inform the choice of wave-sets used for partial wave analyses, supporting GlueX in its search for exotic hybrid meson states.

Fitches, James↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Improving Fission Products at CARIBU: Near Field Detection (Q1/FY24 Quarterly Progress Report)

The article on “Direct Mass Measurements to Inform the Behavior for 128mSb in Nucleosynthesis Environments” by Daniel Hoff et al., recently published in Physical Review Letters. The results of the work are a combination of an extraordinary work on precision mass measurements performed with the Canadian Penning Trap at ANL (the most precise mass measurement of the ground state and the isomeric state in 128Sb performed to date), and an extensive nucleosynthesis theory calculation that include isomers performed by the theorists at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Idealized simulation study of the relationship of disdrometer sampling statistics with the precision of precipitation rate measurement

Due to the discretized nature of rain, the measurement of a continuous precipitation rate by disdrometers is subject to statistical sampling errors. Here, Monte Carlo simulations are employed to obtain the precision of rain detection and rate as a function of disdrometer collection area and compared with World Meteorological Organization guidelines for a 1 min sample interval and 95 % probability. To meet these requirements, simulations suggest that measurements of light rain with rain rates R ≤ 0.50 mm h-1 require a collection area of at least 6 cm × 6 cm, and for R = 1 mm h -1 , the minimum collection area is 13 cm × 13 cm. For R = 0.01 mm h -1 , a collection area of 2 cm × 2 cm is sufficient to detect a single drop. Simulations are compared with field measurements using a new hotplate device, the Differential Emissivity Imaging Disdrometer. The field results suggest an even larger plate may be required to meet the stated accuracy, likely in part due to non-Poissonian hydrometeor clustering.

54 ENVIRONMENTAL SCIENCES↗

Elastic positron–proton scattering at low Q$^2$

Systematic differences in the the proton's charge radius, as determined by ordinary atoms and muonic atoms, have caused a resurgence of interest in elastic lepton scattering measurements. The proton's charge radius, defined as the slope of the charge form factor at Q$^2$=0, does not depend on the probe. Any difference in the apparent size of the proton, when determined from ordinary versus muonic hydrogen, could point to new physics or need for the higher order corrections. While recent measurements seem to now be in agreement, there is to date no high precision elastic scattering data with both electrons and positrons. A high precision proton radius measurement could be performed in Hall B at Jefferson Lab with a positron beam and the calorimeter based setup of the PRad experiment. This measurement could also be extended to deuterons where a similar discrepancy has been observed between the muonic and electronic determination of deuteron charge radius. A new, high precision measurement with positrons, when viewed alongside electron scattering measurements and the forthcoming MUSE muon scattering measurement, could help provide new insights into the origins of the proton radius puzzle, and also provide new experimental constraints on radiative correction calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New precise half-life measurement for the superallowed β+ emitter Ar34

We have measured the half-life of 34 Ar, the parent of a superallowed 0 + → 0 + β transition, to be 0.84646(35) s. With a precision of 0.04%, this result is an essential ingredient needed to complete a third pair of mirror superallowed transitions, 34 Ar → 34 Cl and 34 Cl → 34 S, the ratio of whose ft values would provide the most sensitive test yet of the isospin-symmetry-breaking corrections used to obtain V ud . In a sequence repeated thousands of times, we implanted a very pure 34 Ar beam into tape for 0.7 s, and then rapidly transported the collected source to a shielded 4π proportional gas counter, which detected the decay positrons from the combined decays of 34 Ar and its daughter 34 Cl. The data were analyzed as a linked parent-daughter pair. Our new result replaces one we published 13 years ago.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of directed flow in Au + Au collisions at $\sqrt{s{NN}}$ = 19.6 and 27 GeV with the STAR event plane detector

In heavy-ion collision experiments, the global collectivity of final-state particles can be quantified by anisotropic flow coefficients (𝑣 𝑛 ) . The first-order flow coefficient, also referred to as the directed flow (𝑣 1 ), describes the collective sideward motion of produced particles and nuclear fragments in heavy-ion collisions. It carries information on the very early stage of the collision, especially at large pseudorapidity (𝜂), where it is believed to be generated during the nuclear passage time. Directed flow therefore probes the onset of bulk collective dynamics during thermalization, providing valuable experimental guidance to models of the pre-equilibrium stage. In 2018, the Event Plane Detector (EPD) was installed in STAR and used for the Beam Energy Scan phase-II (BES-II) data taking. The combination of EPD (2.1 < |𝜂| < 5.1) and high-statistics BES-II data enables us to extend the 𝑣 1 measurement to the forward and backward 𝜂 regions. In this paper, we present the measurement of 𝑣 1 over a wide 𝜂 range in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV using the STAR EPD. The results of the analysis at $\sqrt{s_{NN}}$ = 19.6 GeV exhibit excellent consistency with the previous PHOBOS measurement, while elevating the precision of the overall measurement. The increased precision of the measurement also revealed finer structures in heavy-ion collisions, including a potential observation of the first-order event-plane decorrelation. Multiple physics models were compared to the experimental results. Only a transport model and a three-fluid hybrid model can reproduce a sizable 𝑣 1 at large 𝜂 as was observed experimentally. The model comparison also indicates 𝑣 1 at large 𝜂 might be sensitive to the QGP phase transition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MEASUREMENT OF THE GENERALIZED POLARIZABILITIES OF THE PROTON IN VIRTUAL COMPTON SCATTERING

Understanding how the visible matter in the universe arises from its elementary quark and gluon constituents is a central question for science. The visible world is founded on the proton, the only composite building block of matter that is stable in nature. Consequently, understanding the formation of matter relies on explaining the dynamics and the properties of the proton?s bound state. A fundamental property of the proton involves the system?s response to an external electromagnetic (EM) field. It is characterized by the EM polarizabilities that describe how easily the charge and magnetization distributions inside the system are distorted by the EM field. When the polarizabilities are generalized to finite momentum transfer, their Fourier transform can map out the spatial distribution of the polarization densities in a proton subject to an EM field. This thesis focuses on the measurement of the proton generalized polarizabilities (GPs) at low four-momentum transfer in experimental Hall C at the Thomas Jefferson National Accelerator Facility (TJNAF). Among the six independent GPs, we will focus on the electric (aE1) and the magnetic (bM1) scalar GPs. The GPs can be accessed through measurements of the Virtual Compton Scattering reaction, by replacing the incoming real photon of the Compton scattering process with a space-like virtual photon. The outgoing real photon provides the EM perturbation to the system. In addition, the Dispersion Relation Formalism is used for generalized polarizability extraction. In this work, the two scalar GPs measured with unprecedented precision, and the measurements help explore a momentum transfer region where an anomalous enhancement of the electric GP that contradicts the predictions of nuclear theory has been observed.

Li, Ruonan↗