Multiple operating points in photovoltaic power systems.
Multiple operating points in photovoltaic power systems analyzed for lockup condition using graphs
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Multiple operating points in photovoltaic power systems analyzed for lockup condition using graphs
Isotope reentry vehicle/Brayton cycle space power system design, noting blunt conical aeroshell housing of heat source capsule
Aircraft electrical power systems optimization
Developing suitable solid state power controllers for space vehicles electrical power systems
Nuclear space power systems computer simulation for preliminary system and mission analysis, considering Brayton, Rankine and thermionic systems
Nuclear reactor Brayton cycle space power system design point characteristics, discussing cycle parameters, working fluid, turbine inlet temperature, operating pressure level, etc
The use of solar thermal power systems coupled with thermal energy storage (TES) is being studied for both terrestrial and space applications. In the case of terrestrial applications, it was found that one or two hours of TES could shift the insolation peak (solar noon) to coincide with user peak loads. The use of a phase change material (PCM) is attractive because of the higher energy storage density which can be achieved. However, the use of PCM has also certain disadvantages which must be addressed. Proof of concept testing was undertaken to evaluate corrosive effects and thermal ratcheting effects in a slurry system. It is concluded that the considered alkali metal/alkali salt slurry approach to TES appears to be very viable, taking into account an elimination of thermal ratcheting in storage systems and the reduction of corrosive effects. The approach appears to be useful for an employment involving temperatures applicable to Brayton or Stirling cycles.
The Space Station solar dynamic power system is a hybrid of solar photovoltaic and solar dynamic systems, the latter of which uses a parabolic reflector to collect solar energy. This paper describes analytical results of an off-axis solar illumination on the intensity distribution in arbitrary target planes perpendicular to the axis of a parabolic reflector. Such computational capability would make it possible to predict optical intensity distributions resulting from off-axis angles of incident radiation on such target planes. To validate the computer code, experimental optical measurements were performed on the multifaceted paraboloidal collecor at the Solar Dynamic Test Facility at Rockedyne's Santa Susana Field Laboratory. The experimental data compared reasonably well with the calculated values.
Interactions of the SP-100 power system with its expected ambient environments are defined. SP-100 payloads will float 100 V negative of the low Earth orbit (LEO) plasma. Choice of proper geometries and materials will prevent arcing at conductor-insulator junctions in LEO. Care in selecting surface coatings will prevent dielectric breakdown. Sputtering is a concern for long-duration LEO missions. Atomic oxygen durability of SP-100 materials will be tested in ground and flight tests. Evaluation of SP-100 in lunar and planetary environments has begun. The report of a recent workshop on Chemical and Electrical Interactions on Mars identified many of the primary interactions.
The potential economic benefit of small solar thermal electric power systems to small municipal and rural electric utilities is assessed. Five different solar thermal small power system configurations were considered in three different solar thermal technologies. The configurations included: (1) 1 MW, 2 MW, and 10 MW parabolic dish concentrators with a 15 kW heat engine mounted at the focal point of each dish, these systems utilized advanced battery energy storage; (2) a 10 MW system with variable slat concentrators and central steam Rankine energy conversion, this system utilized sensible thermal energy storage; and (3) a 50 MW central receiver system consisting of a field of heliostats concentrating energy on a tower-mounted receiver and a central steam Rankine conversion system, this system also utilized sensible thermal storage. The results are summarized in terms of break-even capital costs. The break-even capital cost was defined as the solar thermal plant capital cost which would have to be achieved in order for the solar thermal plants to penetrate 10 percent of the reference small utility generation mix by the year 2000. The calculated break-even capital costs are presented.
In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.
Data defining space environmental effects on the Long Duration Exposure Facility (LDEF) are examined in terms of the design of the electrical power system (EPS) of the Space Station Freedom (SSF). The significant effects of long-term exposure to space are identified with respect to the performance of the LDEF's materials, components, and systems. A total of 57 experiments were conducted on the LDEF yielding information regarding coatings, thermal systems, electronics, optics, and power systems. The resulting database is analyzed in terms of the specifications of the SSF EPS materials and subsystems and is found to be valuable in the design of control and protection features. Specific applications are listed for findings regarding the thermal environment, atomic oxygen, UV and ionizing radiation, debris, and contamination. The LDEF data are shown to have a considerable number of applications to the design and planning of the SSF and its EPS.
A 100 kWe thermionic nuclear power system conceptual design has been completed as part of the SP-100 space power program. The configuration and performance of the baseline system and its components are described along with the rationale for the selection of coolant and structural material. Growth and scalability are also discussed.
In this work, we discuss the design of visualizations for understanding the complex oscillatory dynamics of an island power system with renewable generation sources after the loss of a large oil power plant. As more renewable generation sources are added to power systems, the oscillatory dynamics will change, which requires new visualization techniques to determine causes and strategies to avoid unwanted behaviors in the future. Our approach integrates geographic views, time-series plots, and novel oscillatory-trajectory curves, providing unique insights into the interdependent oscillatory behaviors of multiple state variables and generators over time. By enabling multi-node and multivariate comparisons over time, users can qualitatively determine drivers of oscillations and differences in generator dynamics, which is not possible with other commonly used visualization techniques.
Resilience is a vital concept in engineering, business, and natural sciences, and is a measure of the ability of an entity to withstand High Impact Low Probability (HILP) events. During the COVID-19 pandemic, which started in late 2019/early 2020, power system utilities around the globe have responded in effective and efficient ways to enhance the resilience of their organisations, both in terms of real-time operations and prudent management of its infrastructure, in order to continue their mandate in providing reliable supply to meet customer demands. Here, this paper presents the CIGRE definition for power system resilience, established by the C4.47 Working Group in 2018, and demonstrates the application of resilience-oriented thinking within the electrical sector. The response and recovery efforts are described, with respect to the key actionable measures integral to the power system resilience definition, taken before, during and after the COVID-19 pandemic. A practical conceptual framework is also presented for thinking about resilience in terms of three key components of resilience strategies: organisational, infrastructure and operational resilience. The paper also discusses the different strategies adopted in response to COVID-19, based on the C4.47 members’ experiences during the pandemic. Finally, a case study is presented, which proves the effectiveness of a set of response measures, using graph theory and the characteristics of the staff-asset interactions.
The satellite power systems point design concept is described. The concept definition includes satellite, ground and space systems, and their relationships. Emphasis is placed on the definition of the GaAlAs photovoltaic satellite system. The major subsystems of the satellite system including power conversion, power distribution and control, microwave, attitude control and stationkeeping, thermal control, structures, and information management and control are discussed.
A number of attractive options are available for the Space Station Power System. These include a photovoltaic system or solar dynamic system for power generation, batteries or fuel cells for energy storage and ac or dc for power management and distribution. These options are being explored during the present preliminary design and definition phase of the Space Station Program. Final selections are presently targeted for January 1986.
The results of design integration studies of uranium-zirconium hydride (UZr-Hx) reactor power systems for the NASA space base study program are presented. The power conversion systems investigated include the Brayton cycle, the organic Rankine cycle, the SNAP-8 mercury Rankine cycle, and thermoelectric (PbTe). The proposed space base has a 10-year life and requires 100 kWe of power. Two 50-kWe power systems with a nominal replacement life of 5 years are utilized. Parametric design data such as life, weight, radiator area, reactor outlet-temperature, reactor thermal power, and power conversion system efficiency are presented and used for the design and integration of the system with the space base.