Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale distribution system of 11,000 nodes, the DERMS software controller, and 90 power hardware photovoltaics (PVs) and battery inverters. The applied DERMS algorithm is designed based on a realtime optimal power flow algorithm and implemented with acceleration design that performs fast dispatch of simulated PVs and real physical hardware DER devices every 4 seconds.

DERMS↗

Augmentation of the space station module power management and distribution breadboard

The space station module power management and distribution (SSM/PMAD) breadboard models power distribution and management, including scheduling, load prioritization, and a fault detection, identification, and recovery (FDIR) system within a Space Station Freedom habitation or laboratory module. This 120 VDC system is capable of distributing up to 30 kW of power among more than 25 loads. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level consists of fast, simple (from a computing standpoint) switchgear that is capable of quickly safing the system. At the next level are local load center processors, (LLP's) which execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. Above the LLP's are three cooperating artificial intelligence (AI) systems which manage load prioritizations, load scheduling, load shedding, and fault recovery and management. Recent upgrades to hardware and modifications to software at both the LLP and AI system levels promise a drastic increase in speed, a significant increase in functionality and reliability, and potential for further examination of advanced automation techniques. The background, SSM/PMAD, interface to the Lewis Research Center test bed, the large autonomous spacecraft electrical power system, and future plans are discussed.

Walls, Bryan↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Systems study for an Integrated Digital-Electric Aircraft (IDEA)

The results of the Integrated Digital/Electric Aircraft (IDEA) Study are presented. Airplanes with advanced systems were, defined and evaluated, as a means of identifying potential high payoff research tasks. A baseline airplane was defined for comparison, typical of a 1990's airplane with advanced active controls, propulsion, aerodynamics, and structures technology. Trade studies led to definition of an IDEA airplane, with extensive digital systems and electric secondary power distribution. This airplane showed an improvement of 3% in fuel use and 1.8% in DOC relative to the baseline configuration. An alternate configuration, an advanced technology turboprop, was also evaluated, with greater improvement supported by digital electric systems. Recommended research programs were defined for high risk, high payoff areas appropriate for implementation under NASA leadership.

Tagge, G. E.↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of 20 kHz space station power distribution technology

Power Distribution on the NASA Space Station will be accomplished by a 20 kHz sinusoidal, 440 VRMS, single phase system. In order to minimize both system complexity and the total power coversion steps required, high frequency power will be distributed end-to-end in the system. To support the final design of flight power system hardware, advanced development and demonstrations have been made on key system technologies and components. The current status of this program is discussed.

Hansen, Irving G.↗

Digital Control Technologies for Modular DC-DC Converters

Recent trends in aerospace Power Management and Distribution (PMAD) systems focus on using commercial off-the-shelf (COTS) components as standard building blocks. This move to more modular designs has been driven by a desire to reduce costs and development times, but is also due to the impressive power density and efficiency numbers achieved by today's commercial DC-DC converters. However, the PMAD designer quickly learns of the hidden "costs" of using COTS converters. The most significant cost is the required addition of external input filters to meet strict electromagnetic interference (MIAMI) requirements for space systems. In fact, the high power density numbers achieved by the commercial manufacturers are greatly due to the lack of necessary input filters included in the COTS module. The NASA Glenn Research Center is currently pursuing a digital control technology that addresses this problem with modular DC-DC converters. This paper presents the digital control technologies that have been developed to greatly reduce the input filter requirements for paralleled, modular DC-DC converters. Initial test result show that the input filter's inductor size was reduced by 75 percent, and the capacitor size was reduced by 94 percent while maintaining the same power quality specifications.

Button, Robert M.↗

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defensive Islanding to Enhance the Resilience of Distribution Systems Against Cyber-Induced Failures

The extensive integration of communication, computation, and control technologies into cyber-physical power systems (CPPSs) has increased the vulnerabilities of CPPSs to cyberattacks. This calls for developing solutions that assess and reduce the impacts of cyber-induced failures on CPPSs. This paper proposes a defensive islanding strategy to isolate impacted parts of the CPPS and form self-sufficient islanded grids with an objective of minimum load curtailment. The defensive islanding aims to split a power system into smaller grids to improve its resilience against a potential extreme event. A clustering approach that leverages the hierarchical spectral clustering method is utilized for the optimal defensive islanding. The proposed approach captures the fragility behavior and loading conditions of power system components due to cyber-induced failures. A graphical-based coupling framework is used to map the impacts of cyber failures into operation of power system components. The proposed method is demonstrated on a modified 33-node distribution feeder system integrated with distributed energy resources. The amount of load curtailment and radiality constraints have been used to evaluate the performance of the proposed clustering strategies. The results show the capability of the proposed algorithm to create islands considering the cyber-induced failures for enhanced resilience.

cyber-induced failures↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Tidal Power for Enhancing Power System Resilience with Networked Microgrids

The resilience of a power system to withstand a high-impact low-frequency event is a growing concern, especially in coastal communities that tend to be densely populated and very prone to extreme events such as storms and flooding. In such areas, marine renewable energy can be integrated with the existing renewable energy sources to improve generation diversity and power system resiliency. Using networked microgrids as an example, this paper proposes an empirical study to investigate the impact of marine resources, in particular, tidal energy on the power system resiliency. A set of quantitative metrics with intuitive physical interpretations is used to evaluate the resiliency of a power system that is enhanced with distributed generation in the form of rooftop photovoltaic systems and tidal generators. The effectiveness of resource diversification on the power system resiliency is demonstrated through simulations on a model of a real-world coastal distribution feeder located in Sequim, Washington.

Peerzada, Aaqib A.↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Power management

The multihundred kW power system management and a distribution program aims to develop critical components, circuits, and subsystems required to manage the generation, storage, and distribution of energy in large, orbital space systems. To accomplish this objective, a reference system including subsystems for the generation and storage of energy and management of electrical and thermal energy was designed and is being used to assess at the system level the impact of changing various subsystem parameters. A power management subsystem will then be designed. The subsystem is autonomous and based on ground utility systems concepts to the maximum extent possible. An agency power system breadboard is under development for characterizing and verifying the various component and subsystem technology developments.

Graves, J.↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Distributed Energy Resource Management Systems Using Software- and Hardware-in-the-Loop

Distributed energy resource management systems (DERMS) are an important emerging technology for coordinating distributed energy resources (DERs) integrated in power distribution networks. These solutions implement a software platform to monitor, control, and coordinate DERs in real time to provide aggregate grid services to the electric utility or distribution system operator. To move DERMS technology forward, research and performance validation in a laboratory environment are needed to ensure proper function of DERMS prior to field deployment. This presentation presents a generic hardware-in-the-loop (HIL) platform to evaluate performance of DERMS using software-in-the-loop (SIL) and power HIL. The platform provides realistic testing in a laboratory environment, including accurate modeling of full-scale distribution systems, DERMS software controllers, and at-power distributed energy resources (DERs), such as solar and battery inverters. Two case studies are presented to demonstrate how the platform can be used independently as an integrated development and validation approach for different projects. Laboratory testing results are included to showcase the voltage regulation performance of each study and the benefits of implementing such a platform for DERMS evaluation.

DERMS↗

Design and fabrication of a photovoltaic power system for the Papago Indian village of Schuchuli (Gunsight), Arizona

A stand alone photovoltaic power system for installation in the Papago Indian village of Schuchuli is being designed and fabricated to provide electricity for village water pumping and basic domestic needs. The system will consist of a 3.5 kW (peak) photovoltaic array; controls, instrumentations, and storage batteries located in an electrical equipment building and a 120 volt dc village distribution network. The system will power a 2 HP dc electric motor.

Bifano, W. J.↗