At least 847 records · Page 47

Effective Selective Area Doping for GaN Vertical Power Transistors Enabled by Innovative Materials Engineering

GaN vertical power transistors have emerged as promising candidates for future high efficiency high power electronic applications, with the potential to outperform conventional GaN lateral power devices in terms of power, breakdown, and avalanche characteristics. However, the development of current GaN vertical power transistors is seriously hindered by the poor materials performance of selective area doped p-n junctions. A mechanistic understanding of these fundamental materials issues is essential in order to achieve high performance selective area doped p-n junctions and consequently to advance the GaN vertical power transistor technology. To address this challenge, we carried out a comprehensive research program that advance fundamental knowledge in the selective area doping for GaN materials, and which will lead to the development of high performance GaN vertical power transistors. First, we developed innovative fabrication processes, including novel surface etching, surface passivation, and metalorganic chemical vapor deposition (MOCVD) growth, which provided enhanced opportunities for solving the unique challenges of selective area doping in GaN materials. Second, we performed a fundamental materials study using powerful characterization methods including transmission electron microscopy (TEM), ultraviolet (UV-), x-ray and angle-resolved photoelectron spectroscopy (UPS/XPS/ARPES), electron holography, and cathodoluminescence (CL); Third, we investigated several related issues, including Mg incorporation, polarization effects in carrier transport, and non-ideal material effects, which have rarely been explored so far. At the end of this project, we successfully demonstrated (1) fundamental understanding of selective area etching, regrowth, and doping of GaN, and associated knowledge on defects, interface, and breakdown properties. (2) Effective etch and regrowth processing recipes to achieve etch/regrowth GaN p-n diodes with very low leakage of 3.5 nA at 600 V, which meets the ARPA-E target. (2) High performance vertical GaN p-n didoes and vertical junction termination extension (JTE) devices with breakdown voltage of ~ 2 kV, and breakdown electric field of ~ 3.5 MV/cm, which are close to the performance limit of GaN. The successful outcome has resulted in new fundamental understandings in the selective area doping and regrowth process for GaN, which will lead to groundbreaking GaN vertical transistors for high performance next generation power electronics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Day-Ahead PV Estimation Using Autoencoder-LSTM and Persistence Model

Inherent variability in photovoltaic (PV) and associated impacts on power systems is a challenging problem for both the PV owners and the grid operators. Existing statistical and machine learning algorithms typically work well for weather conditions similar to historical data. Furthermore, uncertain weather conditions pose a great challenge to the estimation accuracy of the estimation models. With the enhanced integration of intelligent electronic devices and the realization of associated automation in the power grid, renewable energy data is becoming more accessible, which can be utilized by deep learning models and improve the PV power generation estimation accuracy. In this paper, a hybrid deep learning model driven by external weather data is proposed to do day-ahead PV output forecasting at 15-minute-interval. The proposed model is motivated by the recent advancement of Long-Short-Term-Memory (LSTM) networks and AutoEncoder (AE), which estimates uncertainties in sequence while making the prediction for complex weather conditions. Meanwhile, the persistence model (PM) is used to predict continuous sunny weather conditions. The forecasting result is validated with data from multiple locations

42 ENGINEERING↗

Using spatio-temporal graph neural networks to estimate fleet-wide photovoltaic performance degradation patterns

Accurate estimation of photovoltaic (PV) system performance is crucial for determining its feasibility as a power generation technology and financial asset. PV-based energy solutions offer a viable alternative to traditional energy resources due to their superior Levelized Cost of Energy (LCOE). A significant challenge in assessing the LCOE of PV systems lies in understanding the Performance Loss Rate (PLR) for large fleets of PV systems. Estimating the PLR of PV systems becomes increasingly important in the rapidly growing PV industry. Precise PLR estimation benefits PV users by providing real-time monitoring of PV module performance, while explainable PLR estimation assists PV manufacturers in studying and enhancing the performance of their products. However, traditional PLR estimation methods based on statistical models have notable drawbacks. Firstly, they require user knowledge and decision-making. Secondly, they fail to leverage spatial coherence for fleet-level analysis. Additionally, these methods inherently assume the linearity of degradation, which is not representative of real world degradation. To overcome these challenges, we propose a novel graph deep learning-based decomposition method called the Spatio-Temporal Graph Neural Network for fleet-level PLR estimation (PV-stGNN-PLR). PV-stGNN-PLR decomposes the power timeseries data into aging and fluctuation components, utilizing the aging component to estimate PLR. PV-stGNN-PLR exploits spatial and temporal coherence to derive PLR estimation for all systems in a fleet and imposes flatness and smoothness regularization in loss function to ensure the successful disentanglement between aging and fluctuation. We have evaluated PV-stGNN-PLR on three simulated PV datasets consisting of 100 inverters from 5 sites. Experimental results show that PV-stGNN-PLR obtains a reduction of 33.9% and 35.1% on average in Mean Absolute Percent Error (MAPE) and Euclidean Distance (ED) in PLR degradation pattern estimation compared to the state-of-the-art PLR estimation methods.

14 SOLAR ENERGY↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Implication of production tax credit on economic dispatch for electricity merchants with storage and wind farms

The production tax credit (PTC) promotes wind energy development, reduces power generation costs, and can affect merchants’ joint economic dispatch, particularly for electricity merchants with both energy storage and wind farms. Two common PTC policies are studied – in the first policy, a wind farm receives PTC by selling wind generation to the market and its storage can be used to store energy from the wind generation and energy purchased from the grid but the energy released from the storage cannot receive PTC; in the second policy, the energy released from the storage can also qualify for PTC but purchasing energy from the grid is not allowed. We then employ dynamic programming to study merchants' optimal decision-making while considering PTC and the physical characteristics of storage systems. We analytically show that the state of charge (SOC) range can be segmented into different regions by SOC reference points under two PTC policies. The merchant's optimal action can be conveniently and uniquely determined based on the region within which the current SOC falls. Moreover, this study illustrates that PTC could substantially alter the optimal scheduling policy structures by affecting reference points and their relationships. The results showed that the frequencies for charging and discharging storage decisions decreased with an increase in PTC subsidy. Last, we confirm that, although the first policy allows merchants to buy electricity from the market, the second policy can bring more profits when the PTC is large at the current PTC rates. Furthermore, the findings can provide multistage decision-making guidance to electricity merchants in the wholesale power market.

17 WIND ENERGY↗

MRS Modelling in OpenFAST

Multi-rotor wind turbines, where more than one rotor is connected to a single support structure, are increasing in popularity due to their balance of power generation with component size, weight, and cost. Multi-rotor turbines are also common in marine energy, where deployment sites tend to be depth-constrained, limiting the maximum size of a rotor. To support the industry and research communities in designing and modeling multi-rotor turbines, the open-source turbine modeling tool OpenFAST, developed and supported by the National Renewable Energy Laboratory, is being extended to model multi-rotor wind and marine turbines. This presentation gives an overview of the current state of OpenFAST, planned changes to enable coupled aero-hydro-servo-elastic dynamic modeling of multi-rotor turbines, and examples of the types of turbines that OpenFAST will support.

marine energy↗

Distributed Solar Quality and Safety in India: Key Challenges and Potential Solutions

The quality and safety of solar systems and their installation has become a concern for investors, regulators, consumers, and Discoms in India. The push for low prices and lack of quality standards are driving project developers to install low quality products, with poor system design and execution on-site. Existing literature and stakeholder interviews point to the rampant use of low quality, sub-standard solar products in India. These products deliver less energy than expected, or have high detrition rates, or have lower product life–all of which are serious issues for developers whose return on investment depend on the amount of power generation from these solar systems for the expected life of the project. Equipment which does not conform to the minimum quality standards also creates safety risks for the distribution network. Performance and safety concerns lower investor and consumer confidence in solar products with the potential to threaten market development. This report formulates a set of recommendations to concerned authorities in India to improve the quality and safety of rooftop solar systems. Primary and secondary sources are employed to understand the current solar quality and safety scenario in India to provide the basis for future recommendations. An overview of international experiences and lessons learned on solar quality and safety issues is also conducted to understand potential solutions for India.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of abatement potentials and costs of air pollution emissions in China

Understanding the air pollution emission abatement potential and associated control cost is a prerequisite to design cost ef?cient control policies. In this study, a linear programming algorithm model, International Control Cost Estimate Tool, was updated with cost data for applications of 56 types of end-of-pipe technologies and ?ve types of renewable energy in 10 major sectors namely power generation, industry combustion, cement pro-duction, iron and steel production, other industry processes, domestic combustion, transportation, solvent use, livestock rearing, and fertilizer use. The updated model was implemented to estimate the abatement potential and marginal cost of multiple pollutants in China. The total maximum abatement potentials of sulfur dioxide (SO2), nitrogen oxides (NOx), primary particulate matter (PM2.5), non-volatile organic compounds (NMVOCs), and ammonia (NH3) in China were estimated to be 19.2, 20.8, 9.1, 17.2 and 8.6 Mt, respectively, which accounted for 89.7%, 89.9%, 94.6%, 74.0%, and 80.2% of their total emissions in 2014, respectively. The associated control cost of such reductions was estimated as 92.5, 469.7, 75.7, 449.0, and 361.8 billion CNY in SO2, NOx, primary PM2.5, NMVOCs and NH3, respectively. Shandong, Jiangsu, Henan, Zhejiang, and Guangdong provinces exhibited large abatement potentials for all pollutants. Provincial disparity analysis shows that high GDP regions tend to have higher reduction potential and total abatement costs. End-of-pipe technologies tended be a cost-ef?cient way to control pollution in industries processes (i.e., cement plants, iron and steel plants, lime production, building ceramic production, glass and brick production), whereas such technologies were less cost- effective in fossil fuel-related sectors (i.e., power plants, industry combustion, domestic combustion, and transportation) compared with renewable energy. The abatement potentials and marginal abatement cost curves developed in this study can further be used as a crucial component in an integrated model to design optimized cost-ef?cient control policies.

Zhang, Fenfen↗

The U.S. Agrivoltaic Shading Tool: A National-Scale Interface for Modeling Light and Shade Patterns in Ten Common Agrivoltaic Configurations

Agrivoltaic systems are dual-use configurations that co-locate agriculture and photovoltaic (PV) infrastructure and require careful design to balance crop performance and energy generation. A critical element of agrivoltaic design is the spatial and temporal distribution of irradiance and shade within and around PV arrays. To support research, planning, and stakeholder decision-making, we introduce the U.S. Agrivoltaic Shading Tool, a novel web-based application that delivers high-resolution irradiance and photosynthetically active radiation (PAR) modeling for ten standardized PV configurations across the conterminous United States. The tool leverages the National Laboratory of the Rockies (NLR) System Advisor Model (SAM) to perform detailed irradiance simulations, using meteorological data from the National Solar Radiation Database (NSRDB). Outputs include seasonal, monthly, weekly, and diurnal patterns of available sunlight, amount of shade, irradiance, and PAR at ground level within agrivoltaic system footprints. For a user's selected location, these results are visualized through interactive visualizations, heatmaps, and time-series plots, designed to be accessible to both technical and non-technical users. In addition to facilitating rapid spatial exploration of agrivoltaic light environments, the tool will offer seamless integration with the InSPIRE Agrivoltaics Design and Analysis Model (ADAM). This optional workflow will allow users to port selected site and configuration parameters into a more advanced modeling environment for further customization of structural layouts, crop-system compatibility, power generation, and technoeconomic performance. Finally, to promote open science, the entire dataset will be hosted and available for open access through the OpenEI platform. By standardizing and disseminating high-quality irradiance data and design tools, the U.S. Agrivoltaic Shading Tool supports a wide range of users, including researchers, landowners, energy developers, and policymakers, in evaluating the agronomic and energetic feasibility of agrivoltaic systems across the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A grid-scale study of demand bidding by large industrial users

A demand bidding mechanism for engaging large industrial electricity users in the operation of the power grid is presented. Demand bidding is formulated as an optimization problem based on a modified version of the alternating current optimal power flow problem, and can be interpreted as a tâtonnement process between the grid operator and electricity users. Here, the work provides the first – to the authors’ knowledge – grid-scale case study of demand bidding, using a synthetic grid structure in the footprint of the grid of Texas. Results reveal that the demand bidding lowers overall power generation costs, but economic benefits plateau as the number of participants increases. Transmission line and transformer capacity constraints become the limiting factors, revealing that expanding and fortifying the transmission infrastructure is key to expanding demand-side participation. Demand bidding does not substantially alter the optimal operation of existing bidding entities when the number of bidders increases, thereby supporting existing bidders to stay in the system and encouraging new ones to join.

Chlor-alkali plant↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Coordinated Modeling of Electric Grid and Natural Gas Network Operations

Presentation based upon full report of a Colorado case study and coordination framework, which is available at https://www.nrel.gov/docs/fy20osti/77096.pdf. JISEA analysts Brian Sergi, Omar Guerra, and Bri-Mathias Hodge will present on recent JISEA work on coordination between the natural gas and electricity sectors. Power and gas are becoming increasingly interdependent but weren't designed to function together. How does greater coordination impact system operations with different levels of solar and wind penetrations? This free JISEA presentation will take place in a Webinar on Tuesday, May 11, 2021 at 12 p.m.: Learn how greater coordination between the natural gas and electricity sectors impacts system operations with different levels of solar and wind penetrations. Presentation information includes: Historical and projected data for natural gas consumption and power generation in the United States as demonstrated by 2014 East Coast Polar Vortex, 2021 Texas Winter Storm Uri. Showing coupling points, FERC identified need for better coordination, different levels of coordination (decision making and optimization control), coordination framework. Case study on Colorado Front Range, ramping requirements and gas nominations, real-time dispatch (June and December scenarios), results of analysis of impacts of coordination on unserved load. Total real-time gas offtakes by node, impacts on unserved gas, effect on CO2 emissions. Discussions on clusions drawn from Colorado Case study expanded co-simulation via HELICS, objectives of the HELICS+ natural gas use case, modeling of hydrogen blending, techno economic assessment of blending, and blending impacts on energy content and pressure.

analysis↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

Interpretation of hydrothermal conditions, production-injection induced effects, and evidence for enhanced geothermal system-type heat exchange in response to >30 years of production at Roosevelt Hot Springs, Utah, USA

The Roosevelt Hot Springs hydrothermal system is located at the base of the Mineral Mountains in southwestern Utah on the eastern side of the Basin and Range. Hydrothermal activity is related to relatively recent bimodal magmatism, and the system is hosted in coarsely crystalline rock made of Oligocene–Miocene granitoids and Precambrian gneiss. The hydrothermal plume covers ~5 km 2 , with a maximum temperature of 268 °C at ~750 m depth, and a vertically extensive fault-fracture mesh east of the Opal Mound fault controls the upflow of hydrothermal fluids. Power generation (currently 38 MWe gross) began in 1984, and up through 2016, four wells were used for fluid production, and three wells were used for edge-field injection. Chemical analyses of produced fluids show that modern reservoir fluid compositions are similar to but more concentrated than those at the start of production, having near-neutral pH, total dissolved solids of 7000–10,000 mg/kg, and ionic ratios of Cl/HCO 3 ~50–100, Cl/SO4 ~50–100, and Na/K ~4–5. Chemical geothermometers indicate equilibration temperatures that mainly range between 240° and 300 °C. Early production induced a steep drop in pressure (~3.0–3.5 MPa), which was accompanied by a 250–300 m lowering of piezometric levels in wells and development of a shallow steam zone across the system. Hydrothermal fluid compositions evolved continuously in response to production-related steam-loss and injection breakthrough, which is reflected by gradual increases in chloride of up to 35% and stable isotope ratios of up to ~2‰δ 18 O and ~10‰δD. Simple mixing model calculations suggest that there has been a significant amount, ~10–20 MW th , of sustained multi-decadal heat mining and enhanced geothermal system (EGS)–type heat transfer by the injectate as it returns to the production zone. Overall, the two factors that have sustained long-term power production (currently 38 MWe gross) are the increased upflow of deep chloride water and, to a lesser extent, the mining of heat at <1 km depth.

58 GEOSCIENCES↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗