Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Transmission gap, Bragg-like reflection, and Goos-Haenchen shifts near the Dirac point inside a negative-zero-positive index metamaterial slab

Motivated by the realization of the Dirac point (DP) with a double-cone structure for optical field in the negative-zero-positive index metamaterial (NZPIM), the reflection, transmission, and Goos-Haenchen (GH) shifts inside the NZPIM slab are investigated. Due to the linear Dirac dispersion, the transmission as the function of the frequency has a gap, thus, the corresponding reflection has a frequency or wavelength window for the perfect reflection, which is similar to the Bragg reflection in the one-dimensional photonic crystals. Near the DP, the associated GH shifts in the transmission and reflection can be changed from positive to negative with increasing the wavelength. These negative and positive shifts can also be enhanced by transmission resonances when the frequency is far from that at the DP. All these phenomena will lead to some potential applications in the integrated optics and optical devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon position measure

The positive operator valued measure (POVM) for a photon counting array detector is derived and found to equal photon flux density integrated over pixel area and measurement time. Since photon flux density equals number density multiplied by the speed of light, this justifies theoretically the observation that a photon counting array provides a coarse-grained measurement of photon position. The POVM obtained here can be written as a set of projectors onto a basis of localized states, consistent with the description of photon position in a recent quantum imaging proposal [Tsang, Phys. Rev. Lett. 102, 253601 (2009)]. The wave function that describes a photon counting experiment is the projection of the photon state vector onto this localized basis. Collapse is to the electromagnetic vacuum and not to a localized state, thus violating the textbook rules of quantum mechanics but compatible with the theory of generalized observables and the nonlocalizability of an incoming photon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generalized position-momentum uncertainty products: Inclusion of moments with negative order and application to atoms

Rigorous and universal relationships among radial expectation values of any D-dimensional quantum-mechanical system are obtained, using Renyi-like position-momentum inequalities in an information-theoretical framework. Although the results are expressed in terms of four moments (two in position space and two in the momentum one), especially interesting are the cases that provide expressions of uncertainty in terms of products <r{sup a}>{sup 1/a}<p{sup b}>{sup 1/b}, widely considered in the literature, including the famous Heisenberg relationship <r{sup 2}><p{sup 2}>{>=}D{sup 2}/4. Improved bounds for these products have recently been provided, but are always restricted to positive orders a,b>0. The interesting part of this work are the inequalities for negative orders. A study of these relationships is carried out for atomic systems in their ground state. Some results are given in terms of relevant physical quantities, including the kinetic and electron-nucleus attraction energies, the diamagnetic susceptibility, and the height of the peak of the Compton profile, among others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-position independent descriptor for machine learning of material properties

The high-throughput screening of periodic inorganic solids using machine learning methods requires atomic positions to encode structural and compositional details into appropriate material descriptors. These atomic positions are not available a priori for new materials, which severely limits exploration of novel materials. In this work, we overcome this limitation by using only crystallographic symmetry information in the structural description of materials. We show that for materials with identical structural symmetry, machine learning is trivial, and accuracies similar to that of density functional theory calculations can be achieved by using only atomic numbers in the material description. For machine learning of formation energies of bulk crystalline solids, this simple material descriptor is able to achieve prediction mean absolute errors of only 0.07 eV/at on a test dataset consisting of more than 85 000 diverse materials. Finally, this atomic-position independent material descriptor presents a new route of materials discovery wherein millions of materials can be screened by training a machine learning model over a drastically reduced subspace of materials.

36 MATERIALS SCIENCE↗

Abundance of Ground States with Positive Parity

We investigate analytically and numerically a random-matrix model for m fermions occupying {ell}{sub 1} single-particle states with positive parity and {ell}{sub 2} single-particle states with negative parity and interacting through random two-body forces that conserve parity. The single-particle states are completely degenerate and carry no further quantum numbers. We compare spectra of many-body states with positive and with negative parity. We show that in the dilute limit defined by m, {ell}{sub 1,2} {yields} {infinity} and ml {ell}{sub 1,2} {yields} 0, ground states with positive and negative parity occur with equal probability. Differences in the ground-state probabilities are, thus, a finite-size effect and are mainly due to different dimensions of the Hilbert spaces of either parity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectrum and structure of octet and decuplet baryons and their positive-parity excitations

A continuum approach to the three-valence-quark bound-state problem in quantum field theory, employing parametrizations of the necessary kernel elements, is used to compute the spectrum and Poincare-covariant wave functions for all flavor- SU (3) octet and decuplet baryons and their first positive-parity excitations. Such analyses predict the existence of nonpointlike, dynamical quark-quark (diquark) correlations within all baryons; and a uniformly sound description of the systems studied is obtained by retaining flavor-antitriplet-scalar and flavor-sextet-pseudovector diquarks. Thus constituted, the rest-frame wave function of every system studied is primarily S wave in character; and the fast positive-parity excitation of each octet or decuplet baryon exhibits the characteristics of a radial excitation. Importantly, every ground-state octet and decuplet baryon possesses a radial excitation. Hence, the analysis predicts the existence and masses of positive-parity excitations of the Ξ, Ξ*, and Ω baryons, states which have not yet been empirically identified. This body of analysis suggests that the expression of emergent mass generation is the same in all u , d , and s baryons and, notably, that dynamical quark-quark correlations play an essential role in the structure of each one. Furthermore, it also provides the basis for developing an array of predictions that can be tested in new generation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Position-dependent matter density probability distribution function

Here, we introduce the position-dependent probability distribution function (PDF) of the smoothed matter field as a cosmological observable. In comparison to the PDF itself, the spatial variation of the position-dependent PDF is simpler to model and has distinct dependence on cosmological parameters. We demonstrate that the position-dependent PDF is characterized by variations in the local mean density, and we compute the linear response of the PDF to the local density using separate universe N-body simulations. The linear response of the PDF to the local density field can be thought of as the linear bias of regions of the matter field selected based on density. We provide a model for the linear response, which accurately predicts our simulation measurements. We also validate our results and test the separate universe consistency relation for the local PDF using global universe simulations. We find excellent agreement between the two, and we demonstrate that the separate universe method gives a lower variance determination of the linear response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Position-dependent Voronoi probability distribution functions for matter and halos

Here, we measure the Voronoi density probability distribution function (PDF) for both dark matter and halos in N-body simulations. For the dark matter, Voronoi densities represent the matter density field smoothed on a uniform mass scale, which approximates the Lagrangian density field. For halos, the Voronoi densities contain information about the local environment of each halo. We measure the halo virial masses, the total amount of dark matter within each halo Voronoi cell, and the halo Voronoi cell volumes, and we show how halo abundances depend on these three quantities. We then study the position-dependent Voronoi density PDF, measured within finite subregions of the Universe, using separate universe simulations. We demonstrate that the spatial variation of the position-dependent PDF is due to large-scale density fluctuations, indicating that the position-dependent PDF is a biased tracer of large-scale structure. We measure this bias for the dark matter, and interpret it as the bias of regions of the Lagrangian density field that are selected based on density. For the halos, this bias can be interpreted as a form of assembly bias. We present the mapping from late-time to early-time Voronoi density for each simulation dark matter particle, which is highly stochastic. We compare the median of this stochastic map with spherical collapse calculations and discuss challenges involved in modeling the evolution of the density field on these scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gauge invariance of radiative jet functions in the position-space formulation of SCET

In subleading powers of soft-collinear effective theory (SCET), the Lagrangian contains couplings between soft quarks and hard-collinear quarks. Matrix elements of the hard-collinear parts of these couplings are radiative jet functions. In the position-space formulation of SCET, the Lagrangians are constructed from operators that appear to be gauge invariant. Nevertheless, we find violations of gauge invariance arise in the hard-collinear sector because gauge transformations can shift the momentum of a hard-collinear quark field from the hard-collinear sector to the soft sector, where the hard-collinear fields, by definition, have no support. The violations of gauge invariance are manifested in perturbation theory in the hard-collinear sector through the absence of certain Feynman diagrams that would be present in full QCD. A consequence of the absence of these diagrams is that the radiative jet functions that follow directly from the position-space Lagrangians are not gauge invariant, and we demonstrate this through explicit calculations in lower-order perturbation theory. We obtain gauge-invariant Lagrangians by adding to existing position-space Lagrangians terms that are proportional to the soft-quark equation of motion. These gauge-invariant Lagrangians are valid for nonzero, as well as zero, quark masses. We also remark briefly on the gauge invariance of certain Lagrangians that have been constructed in the label-momentum formulation of SCET. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Flux Positivity and Unitarity in Conformal Field Theories

We show that in most conformal field theories the condition of the energy flux positivity, proposed by Hofman and Maldacena, is equivalent to the absence of ghosts. At finite temperature and large energy and momenta, the two-point functions of the stress energy tensor develop light like poles. The residues of the poles can be computed, as long as the only spin-two conserved current, which appears in the stress energy tensor operator-product expansion and acquires a nonvanishing expectation value at finite temperature, is the stress energy tensor. The condition for the residues to stay positive and the theory to remain ghost-free is equivalent to the condition of positivity of energy flux.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of Optical Pulse Position Modulation (PPM) Translating Receiver

M-ary pulse position modulation (M-ary PPM) signaling is a means of transmitting multiple bits per symbol in an intensity modulated/direct detection (IM/DD) system. PPM is used in applications with average power limitations. In optical communication systems, PPM becomes challenging to implement at gigabit rates and/or large M, since pulsed signaling requires higher electronic processing bandwidths than the fundamental transmission rate. they have thus been exploring techniques for PPM communications using optical processing. Previous work described a transmitter algorithm that directly translates a bit sequence of N digital bits to the optical pulse position m for any M = 2{sup N}. It has been considerably more difficult to define a similar receiver algorithm that translates the received optical pulse position directly back to a bit sequence with minimal electronic processing. Designs for specific Ms (e.g., 4-ary) have been shown and implemented, but are difficult to scale to larger M. In this work, they present for the first time a generalized PPM translating receiver that is applicable to all M and data rates.

42 ENGINEERING↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of the Water Table Position in Unconfined Aquifers with MODFLOW 6

Abstract The numerical estimation of the position of the water table in unconfined aquifers is important for many practical applications. Its determination through observations or analytical methods is restricted to a few cases. Therefore, it is often estimated through numerical simulations, which may be affected by numerical artifacts and/or poor stability. We use MODFLOW to estimate the position of the water table for a seemingly simple example problem and demonstrate difficulties that can be faced when performing this kind of numerical simulation. We explain the causes for the numerical challenges that originate from the properties of the mathematical equations that must be solved. Based on the results of more than 600 steady‐state simulations, we show how the stability of the numerical solution can be affected by the values of physical parameters that define the problem (e.g., recharge rate, anisotropy ratio, and other parameters that control the numerical algorithm such as settings of the linear and nonlinear solution methods). Finally, we comment on some best practices to apply numerical simulations to estimate the water table position.

Geology↗

Inhibition of PTEN activity promotes IB4‐positive sensory neuronal axon growth

Abstract Traumatic nerve injuries have become a common clinical problem, and axon regeneration is a critical process in the successful functional recovery of the injured nervous system. In this study, we found that peripheral axotomy reduces PTEN expression in adult sensory neurons; however, it did not alter the expression level of PTEN in IB4‐positive sensory neurons. Additionally, our results indicate that the artificial inhibition of PTEN markedly promotes adult sensory axon regeneration, including IB4‐positive neuronal axon growth. Thus, our results provide strong evidence that PTEN is a prominent repressor of adult sensory axon regeneration, especially in IB4‐positive neurons.

Zhou, Li‐Yu↗

A Nonintrusive Optical Approach to Characterize Heliostats in Utility-Scale Power Tower Plants: Camera Position Sensitivity Analysis

Optics plays a major role in the effectiveness of concentrating solar power (CSP) technologies. The nonintrusive optical (NIO) approach developed by the National Renewable Energy Laboratory uses uncrewed aircraft system (UAS)-based imaging to survey heliostats in a commercial-scale power tower CSP plant and characterize their optical errors. The image processing algorithm uses photogrammetry to calculate the camera position for each image frame, and the accuracy of the estimated optical errors is highly sensitive to the calculated camera position accuracy. In this study, we simulate a series of case studies in python to examine the impact of different parameters of the sensitivity of the camera calculation, including the number of facet corners used as control points for the photogrammetric calculation, precision error in the detected pixel locations of the facet corners in the image, and precision error of the canting and mounting positions of the facets of the heliostat. The case studies consider heliostat geometry based on three commercial designs to serve as representative examples of different possible sizes of heliostats that the NIO method could be applied to. The results show that increasing the number of control points can improve accuracy for heliostats with many facets, pixel precision has a significantly larger impact on camera calculation accuracy than facet canting and mounting errors, and the camera distance and focal length must be chosen to ensure adequate pixel accuracy on the heliostat surface depending on the size of heliostat. In conclusion, based on the results, recommendations for the allowable values of each parameter are provided to achieve the required NIO optical error estimation accuracy depending on the size of heliostat.

14 SOLAR ENERGY↗

Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc

Purpose: The commercial release of volumetric modulated arc therapy techniques using a conventional linear accelerator and the growing number of helical tomotherapy users have triggered renewed interest in dose verification methods, and also in tools for exploring the impact of machine tolerance and patient motion on dose distributions without the need to approximate time-varying parameters such as gantry position, MLC leaf motion, or patient motion. To this end we have developed a Monte Carlo-based calculation method capable of simulating a wide variety of treatment techniques without the need to resort to discretization approximations. Methods: The ability to perform complete position-probability-sampled Monte Carlo dose calculations was implemented in the BEAMnrc/DOSXZYnrc user codes of EGSnrc. The method includes full accelerator head simulations of our tomotherapy and Elekta linacs, and a realistic representation of continous motion via the sampling of a time variable. The functionality of this algorithm was tested via comparisons with both measurements and treatment planning dose distributions for four types of treatment techniques: 3D conformal, step-shoot intensity modulated radiation therapy, helical tomotherapy, and volumetric modulated arc therapy. Results: For static fields, the absolute dose agreement between the EGSnrc Monte Carlo calculations and measurements is within 2%/1 mm. Absolute dose agreement between Monte Carlo calculations and treatment planning system for the four different treatment techniques is within 3%/3 mm. Discrepancies with the tomotherapy TPS on the order of 10%/5 mm were observed for the extreme example of a small target located 15 cm off-axis and planned with a low modulation factor. The increase in simulation time associated with using position-probability sampling, as opposed to the discretization approach, was less than 2% in most cases. Conclusions: A single Monte Carlo simulation method can be used to calculate patient dose distribution for various types of treatment techniques delivered with either tomotherapy or a conventional linac. The method simplifies the simulation process, improves dose calculation accuracy, and involves an acceptably small change in computation time.

60 APPLIED LIFE SCIENCES↗

On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations

Purpose: Every year, new radiotherapy techniques including stereotactic radiosurgery using linear accelerators give rise to new applications of Monte Carlo (MC) modeling. Accurate modeling requires knowing the size of the electron spot, one of the few parameters to tune in MC models. The resolution of integrated megavoltage imaging systems, such as the tomotherapy system, strongly depends on the photon spot size which is closely related to the electron spot. The aim of this article is to clarify the relationship between the electron spot size and the photon spot size (i.e., the focal spot size) for typical incident electron beam energies and target thicknesses. Methods: Three electron energies (3, 5.5, and 18 MeV), four electron spot sizes (FWHM=0, 0.5, 1, and 1.5 mm), and two tungsten target thicknesses (0.15 and 1 cm) were considered. The formation of the photon beam within the target was analyzed through electron energy deposition with depth, as well as photon production at several phase-space planes placed perpendicular to the beam axis, where only photons recorded for the first time were accounted for. Photon production was considered for ''newborn'' photons intersecting a 45x45 cm{sup 2} plane at the isocenter (85 cm from source). Finally, virtual source position and ''effective'' focal spot size were computed by backprojecting all the photons from the bottom of the target intersecting a 45x45 cm{sup 2} plane. The virtual source position and focal spot size were estimated at the plane position where the latter is minimal. Results: In the relevant case of considering only photons intersecting the 45x45 cm{sup 2} plane, the results unambiguously showed that the effective photon spot is created within the first 0.25 mm of the target and that electron and focal spots may be assumed to be equal within 3-4%. Conclusions: In a good approximation photon spot size equals electron spot size for high energy X-ray treatments delivered by linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric accuracy of a deterministic radiation transport based {sup 192}Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator

Purpose: The aim of this work is the dosimetric validation of a deterministic radiation transport based treatment planning system (BRACHYVISION v. 8.8, referred to as TPS in the following) for multiple {sup 192}Ir source dwell position brachytherapy applications employing a shielded applicator in homogeneous water geometries. Methods: TPS calculations for an irradiation plan employing seven VS2000 {sup 192}Ir high dose rate (HDR) source dwell positions and a partially shielded applicator (GM11004380) were compared to corresponding Monte Carlo (MC) simulation results, as well as experimental results obtained using the VIP polymer gel-magnetic resonance imaging three-dimensional dosimetry method with a custom made phantom. Results: TPS and MC dose distributions were found in agreement which is mainly within {+-}2%. Considerable differences between TPS and MC results (greater than 2%) were observed at points in the penumbra of the shields (i.e., close to the edges of the ''shielded'' segment of the geometries). These differences were experimentally verified and therefore attributed to the TPS. Apart from these regions, experimental and TPS dose distributions were found in agreement within 2 mm distance to agreement and 5% dose difference criteria. As shown in this work, these results mark a significant improvement relative to dosimetry algorithms that disregard the presence of the shielded applicator since the use of the latter leads to dosimetry errors on the order of 20%-30% at the edge of the ''unshielded'' segment of the geometry and even 2%-6% at points corresponding to the potential location of the target volume in clinical applications using the applicator (points in the unshielded segment at short distances from the applicator). Conclusions: Results of this work attest the capability of the TPS to accurately account for the scatter conditions and the increased attenuation involved in HDR brachytherapy applications employing multiple source dwell positions and partially shielded applicators.

60 APPLIED LIFE SCIENCES↗