Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Advanced HVAC System for Smart Grid

Rocky Research (Boulder City, NV) has developed an advanced roof top air conditioning unit (RTU) with the potential for providing smart grid functions such as regulation services and PV integration. The RTU contains advanced technologies that have been demonstrated to enable 1) improved coefficient of performance (COP) during start-up transients, 2) improved steady-state efficiency, and 3) blending of DC and AC power with high conversion efficiency. Technologies incorporated by Rocky Research include a pulsing thermal expansion valve (PTXV) to dynamically optimize refrigerant flow, a variable frequency drive (VFD) for the compressor, and on-board integrated power conversion electronics for inverting and blending DC and AC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

OpenDSS-wrapper (Distribution System Co-simulator with Distributed Energy Resource Controls)

Electric grid transformation with the proliferation of distributed energy resources (DER), such as solar photovoltaic (PV), wind, advanced energy storage technologies, and electric vehicles, and the growing use of communication technologies in both transmission and distribution systems are increasing the need to capture the interactions among these systems. Advanced modeling, control, and simulation tools that can perform co-simulation of electric power systems with other domains become indispensable to accurately model these interactions. To address this need, we have developed a codebase that integrates an electric power distribution system simulator, DER models, and DER controls. The codebase is based on OpenDSS, a distribution system simulator, and an existing open source co-simulation framework called HELICS. The contribution and uniqueness of the proposed codebase is that it tailors the generic HELICS framework specifically for distribution grid-related applications. The codebase includes an OpenDSS wrapper that controls the simulation, implements advanced DER controls, and extracts power flows, voltages, and other power system element information from the the distribution network modeled in OpenDSS. Sample HELICS federates, including a federate for OpenDSS, are provided that can communicate messages through the HELICS interface. Sample federates can be modified and additional HELICS federates can be added by the user depending on their use case requirements. SEE ALSO: https://github.com/NREL/dss-cosim

Blonsky, Michael↗

Fort Mason Center: Pier 2 Project

The rooftop Photovoltaic (PV) panels and radiant piping project was constructed by Fort Mason Center as part of its $21 million comprehensive rehabilitation of the Pier 2 shed which include the shed’s electrical, natural gas and water systems. Fort Mason Center improved performance while reducing energy and water usage and costs to demonstrate the efficiencies and opportunities available to large multi-function facilities. The scalable demand of these facilities required a layered approach to conservation, control and production. The project employed a comprehensive retrofit of electrical natural gas, and plumbing systems to maximize efficiency and lower carbon footprint specifically to demonstrate the effectiveness of these strategies in a public setting with varied and diverse use. The project was completed in July 2014 and met the expected outcomes regarding increased comfort and operational efficiency throughout the Pier 2 shed as well as on site electrical generation of current consumption. The entire Pier 2 shed project won a 2015 California Preservation Foundation design award for historic rehabilitation.

14 SOLAR ENERGY↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies. Draft

There exist several different reliability- and approximation-based methods to determine the capacity contribution of solar resources towards resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this article we study the effect of time resolution and solar PV penetration using a capacity planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity factor based on time-series data can yield relatively accurate results for small penetration levels (less than 5%). For higher penetration levels (up to 20%), the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV. Although our results are not general, they highlight the importance of accounting for the variation in both energy and capacity value of solar resources endogenously in capacity planning models. A11 numerical experiments are performed using the IEEE Reliability Test System and 7 years worth of demand and solar data from a utility in Arizona.

14 SOLAR ENERGY↗

Benefits and Critical Knowledge Gaps in Determining the Role of Floating Photovoltaics in the Energy-Water-Food Nexus

Floating solar photovoltaic (FPV) systems have become an increasingly attractive application of photovoltaics (PV) because of land-use constraints, the cost of land and site preparation, and the perceived energy and environmental co-benefits. Despite the increasing interest in FPV systems, a robust validation of their suggested co-benefits and impacts on the nexus of energy, water, and food (EWF) systems is lacking. This information gap makes it challenging for decision makers to justify its adoption—potentially suppressing FPV deployment. To address this gap and to help de-risk this PV deployment opportunity, we (1) review the suggested co-benefits of FPV systems with a focus on the impacts that could alleviate pressures on EWF systems and (2) identify areas where further research is needed to reduce uncertainty around FPV system performance. Our review reveals that EWF nexus-relevant co-benefits, such as improved panel efficiency and reduced land usage, are corroborated in the literature, whereas others, such as water quality impacts, lack empirical evidence. Our findings indicate that further research is needed to quantify the water-related and broader economic, environmental, social, sustainability, justice, and resilience co-benefits and impacts of FPV systems.

14 SOLAR ENERGY↗

Effect of power system technology and mission requirements on high altitude long endurance aircraft

An analysis was performed to determine how various power system components and mission requirements affect the sizing of a solar powered long endurance aircraft. The aircraft power system consists of photovoltaic cells and a regenerative fuel cell. Various characteristics of these components, such as PV cell type, PV cell mass, PV cell efficiency, fuel cell efficiency, and fuel cell specific mass, were varied to determine what effect they had on the aircraft sizing for a given mission. Mission parameters, such as time of year, flight altitude, flight latitude, and payload mass and power, were also altered to determine how mission constraints affect the aircraft sizing. An aircraft analysis method which determines the aircraft configuration, aspect ratio, wing area, and total mass, for maximum endurance or minimum required power based on the stated power system and mission parameters is presented. The results indicate that, for the power system, the greatest benefit can be gained by increasing the fuel cell specific energy. Mission requirements also substantially affect the aircraft size. By limiting the time of year the aircraft is required to fly at high northern or southern latitudes, a significant reduction in aircraft size or increase in payload capacity can be achieved.

Colozza, Anthony J.↗

Deciphering Degradation: Machine Learning on Real-World Performance Data (Final Report)

This project addresses a fundamental flaw in solar PV research and solar project financing; the assumed rate of degradation for solar plants. The solar industry currently relies on an out-dated report that observed a 0.5% degradation rate based on a small sample size of systems (~100). While the research conducted at the time was new and innovative, the solar community has not updated this research and universally applies this 0.5% degradation assumption in financial models. Our project updates this assumption by analyzing observed degradation from the industry’s largest dataset of operating solar assets (>10,000 systems) and creating the first machine-learning model based on these observed results to quantify and identify features that drive degradation. There are two strategic goals for this award: reduce the cost of capital (enable solar to attract more capital) and improve the reliability of solar itself. These dual goals are achieved by leveraging an industry dataset to observe system degradation on a large scale, deploying advanced data analysis and machine learning methods to quantify and predict system reliability, and engaging with industry stakeholders to help them accurately price degradation in financial models.

14 SOLAR ENERGY↗

Investigating Local Carrier Dynamics in PERC Patterned CdTe Solar Cells

Remarkable progress has been achieved in CdTe photovoltaics (PVs) to further improve cell performance while reducing manufacturing costs. Researchers optimized the front contact that leads the short-circuit current density (J sc ) over 31mA/cm 2 (e.g., (Zn, Mg)O buffer layer and/or alloying CdTe with Se). Reese et al. reported an open-circuit voltage (V oc ) over 1 V with group-V doped single crystal, showing the feasibility of increasing V oc in CdTe PV that is fixed to less than 900 mV in most cases. Recent studies suggested that the V oc improvement in polycrystalline CdTe PVs requires well-passivated back contact. One possible strategy is to use CdMgTe alloy (E g > 1.8 eV), where the band-gap offset (ΔE CB ≈ 0.2 eV) reflects minority carrier electrons, thereby decreasing surface recombination. Another strategy is to utilize a stable Al 2 O 3 layer as an electron reflector; experimental works confirmed the improved performance with a conformal Al 2 O 3 layer. In this configuration, the precise control of Al 2 O 3 (≈1 nm) over the entire CdTe layer is essential because the J sc greatly depends on the tunneling current. While promising, both CdMgTe and Al 2 O 3 passivation on CdTe introduce unfavorable valence band offset that blocks the hole transport. Kephart et al. proposed a patterned passixc vation layer (≈ 20 nm Al 2 O 3 ) with point contacts (≈ 3 μm in diameter) that extract hole carriers. This configuration is similar to the passive emitter and rear contact (PERC) design that has been extensively studied in Si PVs. While remarkably high carrier lifetime and photoluminescence (> 10 X) were measured, consistent improvement in V oc and efficiency in this CdTe PERC were not yet observed. At this time, it is unclear how the surface potential is distributed in the presence of patterned Al 2 O 3 reflectors and how this additional field impacts the PV performance for Cu-doped and group-V doped CdTe PERC devices. To tackle this challenge, we develop robust nanofabrication and characterization platform to study CdTe PERC devices consisting of a patterned Al 2 O 3 layer on CdSe( 1-x )Te x (Cu-doped, GrV-doped; x = 0 to 1; CST). First Solar supplies high-quality CST materials. The dark and light I-Vs under 1-sun illumination are extracted for a series of each set of devices. We perform quantitative and qualitative PV analysis for a series of Cu-doped and Gr-V doped PERC devices, showing notably different V oc changes for GrV-doped compared to Cu-doped PERC devices. This project attempts to produce individual contacts on single grains and grain boundaries to measure lateral transport. As a model system, we use a CdSe( 1-x )Te x film on glass prepared by a colossal grain growth (CGG) technique at National Renewable Research Laboratories (NREL). Our preliminary results confirm that intergranular transport is hindered by the electrical barrier formed near grain boundaries. The PERC fabrication and the lateral transport measurement platform developed in this project can easily be applied to other types of advanced CdSe( 1-x )Te x architectures to better understand local photocarrier transport, in turn, providing the fundamental knowledge to improve the performance of CdTe PVs.

14 SOLAR ENERGY↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

GPS vertical axis performance enhancement for helicopter precision landing approach

Several areas were investigated for improving vertical accuracy for a rotorcraft using the differential Global Positioning System (GPS) during a landing approach. Continuous deltaranging was studied and the potential improvement achieved by estimating acceleration was studied by comparing the performance on a constant acceleration turn and a rough landing profile of several filters: a position-velocity (PV) filter, a position-velocity-constant acceleration (PVAC) filter, and a position-velocity-turning acceleration (PVAT) filter. In overall statistics, the PVAC filter was found to be most efficient with the more complex PVAT performing equally well. Vertical performance was not significantly different among the filters. Satellite selection algorithms based on vertical errors only (vertical dilution of precision or VDOP) and even-weighted cross-track and vertical errors (XVDOP) were tested. The inclusion of an altimeter was studied by modifying the PVAC filter to include a baro bias estimate. Improved vertical accuracy during degraded DOP conditions resulted. Flight test results for raw differential results excluding filter effects indicated that the differential performance significantly improved overall navigation accuracy. A landing glidepath steering algorithm was devised which exploits the flexibility of GPS in determining precise relative position. A method for propagating the steering command over the GPS update interval was implemented.

Denaro, Robert P.↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation: Preprint

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

Bayesian structural time series↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Reducing PV Performance Uncertainty by Accurately Quantifying the PV Resource

Reducing uncertainty in the prediction and/or verification of photovoltaic (PV) plant output can directly increase the expected return on investment for each party in a contract, likely leading to more favorable terms for the contract, including a possible reduction in interest rates. Note that a reduction of 1% in the interest rate is estimated to reduce the levelized cost of energy by approximately 0.5 cents/kWh. This project developed a capability to provide spectrally resolved solar information from the National Solar Radiation Data Base (NSRDB), effectively providing 20 years of half-hourly data for all of the United States at a 4-km by 4-km spatial resolution. These data are now available freely to users directly through a geographic information system-based Web interface (https://nsrdb.nrel.gov) as well as through an application programming interface. Users of these data can conduct more accurate prefeasibility studies and assess multiple PV technologies. It is expected that widely used models such as PVSyst, the National Renewable Energy Laboratory's System Advisor Model (SAM), and PlantPredict, designed by First Solar, will develop the capabilities to use these spectral data.

14 SOLAR ENERGY↗

FTIR Investigation of EVA Chemical Bonding Environment and Its Impact on Debond Energy

The chemical makeup of ethylene vinyl acetate (EVA) interfaces in photovoltaic (PV) modules is probed via Fourier-transform infrared spectroscopy (FTIR) to determine the impact of the EVA formulation on the adhesion degradation. EVA samples laminated with glass particles are used to demonstrate the effect of damp heat exposure on the glass-EVA interface, showing that increasing silane content increases chemical stability. Delamination interfaces created in one cell modules demonstrate a high correlation between the siloxane bonding at the silicon cell-EVA interface and the debond energy. A significant decrease in debond energy after UV exposure is also shown to be due in part to decreasing siloxane bond density at the interface. However, FTIR results indicated contributions to the adhesion beyond the chemical interface, and a basic tensile test indicates increasing bulk mechanical properties with increasing silane. These results demonstrate the importance of the EVA formulation on its adhesion performance and long-term reliability. Furthermore, it is shown that FTIR is a capable technique for assessing and quantifying chemical mechanisms within PV modules. These results can then be used to more effectively model module lifetimes and to better design polymer systems for PV modules.

14 SOLAR ENERGY↗

Identifying Challenging Operating Hours for Solar Intergration in the NV Energy System

Abstract-- In this paper, the ability of the Nevada (NV) Energy generation fleet to meet its system balancing requirements under different solar energy penetration scenarios is studied. System balancing requirements include capacity, ramp rate, and ramp duration requirements for load following and regulation. If, during some operating hours, system capability is insufficient to meet these requirements, there is certain probability that the balancing authority’s control and reliability performance can be compromised. These operating hours are considered as “challenging” hours. Five different solar energy integration scenarios have been studied. Simulations have shown that the NV Energy system will be potentially able to accommodate up to 942 MW of solar photovoltaic (PV) generation. However, the existing generation scheduling procedure should be adjusted to make it happen. Fast-responsive peaker units need to be used more frequently to meet the increasing ramping requirements. Thus, the NV Energy system operational cost can increase. Index Terms—Solar Generation, Renewables Integration, Balancing Process, Load Following, Regulation.

capacity↗

US DOE Regional Test Centers Program - 2016 Annual Report.

The US Department of Energy’s Regional Test Center (RTC) program provides outdoor validation and bankability data for innovative solar technologies at five sites across the US representing a range of climate conditions. Data helps get new technologies to market faster and improves US industry competitiveness. Managed by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL), the RTC program partners with US manufacturers of photovoltaic (PV) technologies, including modules, inverters, and balance-of-system equipment. The study is collaborative, with manufacturers (also known as RTC industry partners) and the national labs working together on a system design and validation strategy that meets a clearly defined set of performance and reliability objectives.

14 SOLAR ENERGY↗