Field Experience with 3-Sun Mirror Module Systems

JX Crystals 3-sun PV mirror modules have now been operating in four separate systems in the field for up to 2 years. Two post-mounted 2-axis tracking arrays of 12 modules each were installed at the Shanghai Flower Park in April of 2006. Then 672 modules were installed in a 100 kW array on N-S horizontal beam trackers at the Shanghai Flower Port in November of 2006. Finally, sets of 4 modules were installed on azimuth-tracking carousels on buildings at the Oak Ridge National Lab and at the U. of Nevada in Las Vegas in late 2007. All of these modules in each of these systems are still operating at their initial power ratings. No degradation in performance has been observed. The benefit of these 3-sun PV mirror modules is that they use 1/3 of the silicon single-crystal cell material in comparison to traditional planar modules. Since aluminum mirrors are much cheaper than high-purity single-crystal silicon-cells, these modules and systems should be much lower in cost when manufactured in high volume.

14 SOLAR ENERGY↗

Are policy incentives for solar power effective? Evidence from residential installations in the Northeast

State incentives for solar power have grown significantly in the past several years. This paper examines the effectiveness of policy incentives to increase residential solar photovoltaic (PV) capacity. We use county-level panel data and control for demographic characteristics, solar resources, and pro-environmental preferences. Results show that among financial incentives, rebates have the most impact with an additional $1 per watt rebate increasing annual PV capacity additions by close to 50%. Factors that affect financial returns to solar PV such as electricity price and solar insolation are also found to be significant. Results also point to a significant positive relationship between hybrid vehicle sales and residential PV capacity growth, indicating the importance of pro-environmental preferences as a predictor of solar PV demand. Back of the envelope calculations suggest that the cost of carbon mitigation through rebates is around $184 per ton of CO2.

14 SOLAR ENERGY↗

Artificial Replication of Field Soiling Losses on PV Modules

In this paper, we experimentally demonstrate an improved replication of field soiling losses using an indoor artificial soiling chamber and tests on anti-soiling coated PV modules and coupons. The primary focus is to use site-specific soil collected from module surface and replicate the natural soiling processes including dust concentration in the air, slow and gradual dust accumulation and sedimentation on the module surface during the dominant soiling season of the site of interest. The experiments were conducted on two sample sets having different anti-soiling properties. The first set contains commercial modules with two different surface properties retrieved after three years of exposure from a single PV plant in a mid-Atlantic location; the other set contain glass coupons with three different coating materials that were installed and exposed over 4 months, at Lemoore, California. Major field-representative factors considered here for the close replication in the chamber include: the use of dust collected from modules surfaces at the outdoor sites to give the same dust chemistry; dust particle size distribution and concentration; the charge size of dust (< 0.15 g per injection); field humidity, and module temperature. The effectiveness of antisoiling coatings (or surface properties) for both sample sets were ranked in the artificial testing and were found to be closely matching with the field rank orders of the respective sites and sample sets. This paper provides the rank ordering results to objectively demonstrate the replication of field soiling losses in the artificial soiling chamber.

artificial soiling↗

U.S. Solar Photovoltaic System Cost Benchmark Q1 2018

NREL has been modeling U.S. photovoltaic PV system costs since 2009. The U.S. Solar Photovoltaic System CostBenchmark Q1 2018 report benchmarks costs of U.S. solar PV for residential commercial and utility-scale systems built in the first quarter of 2018 Q1 2018. THE methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential commercial and utility-scale systems and it models the capital costs for such systems.

14 SOLAR ENERGY↗

The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

03 NATURAL GAS↗

Photovoltaic and Cost Analysis for Winston-Salem, North Carolina

This study assesses the feasibility of solar installations at various sites in Winston-Salem, focusing on factors such as solar resource availability, electricity costs, and rooftop area for photovoltaic systems. The analysis begins by estimating daily energy requirements based on annual electricity use, followed by adjusting for seasonal and operational fluctuations. Using regional solar data from the National Solar Radiation Database (NSRDB), we calculate average peak sun hours to determine effective system sizing. A parametric approach using the System Advisor Model (SAM) refines this sizing process, incorporating a safety margin of 1.2 to address demand peaks. Each PV system is designed to fit available rooftop space, and a coverage threshold of 70% is identified as optimal for maximizing cost savings and sustainability. This threshold allows installations to meet substantial energy demands, supporting energy resilience and enhancing economic returns.

14 SOLAR ENERGY↗

Economic Analysis of a Brackish Water Photovoltaic-Operated (BWRO-PV) Desalination System: Preprint

The photovoltaic (PV)-powered reverse-osmosis (RO) desalination system is considered one of the most promising technologies in producing fresh water from both brackish and sea water, especially for small systems located in remote areas. We analyze the economic viability of a small PV-operated RO system with a capacity of 5 m3/day used to desalinate brackish water of 4000 ppm total dissolve solids, which is proposed to be installed in a remote area of the Babylon governorate in the middle of Iraq; this area possesses excellent insolation throughout the year. Our analysis predicts very good economic and environmental benefits of using this system. The lowest cost of fresh water achieved from using this system is US $3.98/ m3, which is very reasonable compared with the water cost reported by small-sized desalination plants installed in rural areas in other parts of the world. Our analysis shows that using this small system will prevent the release annually of 8,170 kg of CO2, 20.2 kg of CO, 2.23 kg of CH, 1.52 kg of particulate matter, 16.41 kg of SO2, and 180 kg of NOx.

14 SOLAR ENERGY↗

U.S. Solar Photovoltaic System Cost Benchmark: Q1 2018

NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2018 (Q1 2018). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

14 SOLAR ENERGY↗

MUNI Ways and Structures Building Integrated Solar Membrane Project

The initial goal of the MUNI Ways and Structures Building Integrated Solar Membrane Installation Project was for the City and County of San Francisco (CCSF) to gain experience using the integrated higher efficiency solar photovoltaic (PV) single-ply membrane product, as it differs from the conventional, low efficiency, thin-film PV products, to determine the feasibility of success of larger deployment.

14 SOLAR ENERGY↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

U.S. Solar Photovoltaic System Cost Benchmark: Q1 2016

NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2016 (Q1 2016). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

14 SOLAR ENERGY↗

U.S. Solar Photovoltaic System Cost Benchmark: Q1 2016

NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2016 (Q1 2016). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

14 SOLAR ENERGY↗

Photovoltaic (PV) Module Technologies: 2020 Benchmark Costs and Technology Evolution Framework Results

This report benchmarks 2020 PV module minimum sustainable price (MSP) via bottom-up manufacturing cost analysis, for established PV technologies in mass production, including crystalline silicon, cadmium telluride (CdTe), and copper indium gallium (di)selenide. We provide technology roadmaps to additional MSP reductions for these PV technologies. Separately, we consider III-V and perovskite PV technologies which are currently in small-scale or pilot production. Finally, this report uses a technology evolution framework (TEF) to analyze drivers of levelized cost of energy reductions, including installed system cost - which is heavily influenced by module price - as well as service life and annual energy yield.

14 SOLAR ENERGY↗

A country-scale green energy-water-hydrogen nexus: Jordan as a case study

Many developing countries suffer from a shortage of clean energy-water production, causing significant dependency on imported fossil fuel to meet the local energy and freshwater demands. Furthermore, when planning a 100 % renewable energy system (RES) to match the energy demand on an hourly basis, the RES is usually oversized. Hence, unavoidable large amounts of excess energy would be generated during hours of high production, low demand, and fully charged energy storage systems (ESSs). Hence, using Jordan as a case study, this work proposes a novel integrated system of wind, solar photovoltaic (PV), and lithium-ion ESS to match 100 % of the country's energy demand while using the excess generated power to drive reverse osmosis water desalination plants to match the demand of freshwater as well. Furthermore, the remaining excess energy is used for producing green hydrogen. A techno-economic optimizer was developed to show that this concept is indeed feasible. Here, the model was used to scan Jordan for the fitting sites of the highest demand-supply matching and the lowest levelized cost of electricity (LCOE), simultaneously. Three different integration scenarios are presented, namely PV-ESS, wind-ESS, and hybrid PV-wind-ESS RESs. The hybrid system showed the best performance, especially compared to the wind-ESS RES, in terms of total installed capacity (33.37 GW), LCOE (0.0492 USD/kWh), specific water cost (0.3629 USD/m 3 ), and energy and water demand-supply fractions (99.47 and 96.16 %, respectively). Storing desalinated water in natural aquifers was found to be a favorable option to enhance the performance of the three systems, where stored water by the end of the year was sufficient to cover the freshwater requirements for several following years. Finally, the remaining excess energy is used to produce green hydrogen with an annual production of up to 1.37 million tons and a specific cost down to 1.08 USD/kg.

14 SOLAR ENERGY↗

Rear-Side Irradiance Simulation of Field PV Modules: Preprint

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand realworld outdoor degradation.

backsheet↗

Information Searching in the Residential Solar PV Market

This paper examines the consumer information search behavior of households in San Diego County with solar photovoltaic (PV) systems. We focus on whether solar PV households financing the technology through third-party ownership (TPO) versus host-ownership (HO), which is equivalent to leasing or buying goods in other markets, have heterogeneous preferences as reflected by information search. Conditional on adoption, we find that TPO households tend to seek more information on home modifications required for solar installation whereas HO households seek more information on the financial returns of solar investments. These preferences may be correlated with the consumption of other goods and services, and thus, if used to inform marketing strategies, our results could help reduce solar PV customer acquisition costs and accelerate technology diffusion. They also have indirect implications for marketing goods and services in other contexts where consumers exhibit similar preferences.

California↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

Remote Power Systems for Sensors on the Northern Border

The National Renewable Energy Laboratory (NREL) is working with the Department of Homeland Security (DHS) [1] to field sensors that accurately track different types of transportation across the northern border of the U.S.. To do this, the sensors require remote power so that they can be placed in the most advantageous geographical locations, often where no grid power is available. This enables the sensors to detect and track aircraft/vehicles despite natural features (e.g., mountains, ridges, valleys, trees) that often prevent standard methods (e.g., monostatic radar or visual observers) from detecting them. Without grid power, portable power systems were used to provide between 80 and 300 W continuously, even in bitter cold and when buried under feet of snow/ice. NREL provides details about the design, installation, and lessons learned from long-term deployment of a second-generation of novel power systems that used adjustable-angle photovoltaics (PV), lithium ion batteries, and fuel cells that provide power to achieve 100% up-time.