Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE VESSEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of a Helical Tube Bundle in Cross-Flow for Application to Flow-Induced Vibration

Helical tubes have been used in a number of systems, including the energy and chemical processing industries. Helical-Coil Steam Generators (HCSGs) in particular have special application in systems for which spatial constraints are important. Variants of these designs are notably included in a number of integral-vessel small modular reactor (SMR) designs which are currently in development by multiple companies. These designs typically have the primary side located within the vessel, with the secondary side flowing upward through the helical tubes. One complexity in implementing an HCSG within the reactor pressure vessel is that any potential flow-induced vibration (FIV) can impact reactor safety. In a typical power plant, heat exchanger tube failures caused by FIV can be costly, but generally do not have immediate impact on the core safety due to their relative isolation from the core area. In an integral-vessel design, a tube rupture could eject material from the secondary side into the primary flow, potentially damaging the core itself or other crucial components. Thus a higher degree of confidence in predicting and/or preventing FIV should be attained for implementing the helical tubes in these designs. A significant campaign is currently underway to address the topic of FIV in helical tube arrays. The U.S. Department of Energy, under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) initiative, has deemed this a 'high-impact problem'. This will include both experimental and computational contributions from a consortium consisting of multiple universities, industry partners, and national laboratories, including Argonne National Laboratory. The primary industrial partner is NuScale, which will see direct benefits from this initiative to the development of their SMR and its component design. The primary focus of this paper is to establish some of the computational efforts that have been made to this stage and the initial benchmarking of computational tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrity Assessment of Hanford 242-A Evaporator Facility E-A-1 Re-boiler Vessel via Fluorescein Liquid Tracer Test Methods - 17357

The 242-A Evaporator Facility is critical to the United States Department of Energy's (DOE) Hanford Site clean-up mission due to limited space within the existing Double-Shell Tanks (DSTs) used to store nuclear and chemical waste until future processing. The 242-A Evaporator Facility is currently the sole waste volume reduction process used at Hanford, and the E-A-1 Re-boiler is essential to the Evaporator process. Due to the potential for cross-contamination between the Re-boiler tubes through which waste passes and the tube sheets of uncontaminated steam, an assessment of the Re-boiler vessel's integrity is required for continuing operations of the facility. In order to meet these requirements, an independent integrity assessment was designed to use fluorescein liquid tracer (LT) to verify the leak-tightness of the Re-boiler vessel in accordance with Washington River Protection Solutions, LLC (WRPS) tightness test standards, as well as, the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 1, NB-6300. LT test methodologies were evaluated and determined to be appropriate for a vessel with restricted access, such as the E-A-1 Re-boiler, as it provided the needed sensitivity, reliability, and cost; as well as, exceeded the leak-tightness specifications required by both WRPS and ASME B and PV Code standards. The integrity test requires water laced with fluorescein be circulated through the waste processing loop of the 242-A Evaporator and samples of steam condensate be collected and analyzed for traces of fluorescein to determine leak-tightness. Liquid condensate sampling was conducted prior to and during testing and the samples were analyzed for fluorescein tracer to determine the amount of fluorescein that flowed out of the tubes of the Re-boiler into the steam side of the vessel. Given the established criteria for 'leak-tight,' test results determined that the Re-boiler passed the integrity assessment. After further scrutiny of the 2014 test and data results, it was determined that although the Re-boiler was 'leak-tight,' as established by the test criteria, there was concern of future leakage. The DOE and the DOE Office of River Protection (ORP) requested that WRPS repeat the integrity assessment in two and a half years to determine if the potential leak was growing, which could threaten continuing operations of the 242-A Evaporator. The 2017 test has been redesigned using lessons learned from the 2014 test and was modified to account for ergonomic and safety considerations, ease of repeatability, and accuracy of results. The liquid tracer methodology and test plan developed for the Re-boiler will continue to be implemented in 5 year increments to monitor current and future integrity. The method may also prove useful for other aging components across the Hanford Site, where appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic emission testing of composite vessels under sustained loading

Acoustic emissions (AE) generated from Kevlar 49/epoxy composite pressure vessels subjected to sustained load-to-failure tests were studied. Data from two different transducer locations on the vessels were compared. It was found that AE from vessel wall-mounted transducers showed a wide variance from those for identical vessels subjected to the same pressure loading. Emissions from boss-mounted transducers did, however, yield values that were relatively consistent. It appears that the signals from the boss-mounted transducers represent an integrated average of the emissions generated by fibers fracturing during the vessel tests. The AE from boss-mounted transducers were also independent of time for vessel failure. This suggests that a similar number of fiber fractures must occur prior to initiation of vessel failure. These studies indicate a potential for developing an AE test procedure for predicting the residual service life or integrity of composite vessels.

Lark, R. F.↗

Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices

Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) with the HDR 1000 Plus well chamber.

07 ISOTOPE AND RADIATION SOURCES↗

Factors Influencing Propensity for Stress Relaxation Cracking in Inconel® Alloy 740H® and Practical Guidance for Applications

Inconel® alloy 740H® (UNS N07740) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. In recent years, advanced energy systems such as supercritical CO2 power cycles have utilized alloy 740H in large demonstration projects driven by the requirement for higher fluid temperatures and pressures. Stress relaxation cracking (SRxC) following post-weld heat-treatment (PWHT), also known as strain age cracking (SAC), has been identified in a limited number of weldments during these industrial builds resulting in focused research to further clarify factors influencing this cracking tendency. This paper will summarize some of the findings from shop and field fabrication leading to successful welds and characteristics of observed SRxC. Laboratory experiments supported by microstructural characterization will be presented to highlight the importance of variables such as strain, material starting condition, and PWHT temperatures. Finally, the results will be summarized within the context of practical guidance for industry to successfully weld the material in boiler, heat exchanger, and piping applications.

14 SOLAR ENERGY↗

Detecting Thermally Induced Spinodal Decomposition with Picosecond Ultrasonics in Cast Austenitic Stainless Steels

Given the existential climate crisis faced by mankind and the world, the lifetime and sustainability of nuclear reactors as a carbon-free source of renewable energy depend on the susceptibility of their structural components to environmental degradation. In particular, critical components for light water reactors (LWRs) evolve over decades in service, losing ductility and toughness due to thermal and irradiation aging. Techniques to monitor their health cannot be easily applied in the field due to their destructive, expensive, or immobile nature. Thus, non-destructive evaluation (NDE) methods are sought to monitor and evaluate the health of major LWR components such as core barrels, steam generator tubes, or primary coolant pipes and are often required by policy, such as NRC policy #10-CFR-50.65. In this work we demonstrate the use of gigahertz, non-contact ultrasonics to gauge the state of cast austenitic stainless steels (CASS), used in some of the largest components in LWR primary systems. We do so by linking changes in their surface acoustic wave (SAW) characteristics using transient grating spectroscopy (TGS) to transmission electron microscopy (TEM)-verified evidence of spinodal decomposition and G-phase precipitation. In this thesis, thermal aging is shown to induce SAW peak splitting in spinodally decomposed CASS alloys, correlated strongly with lowered toughness and decreased ductility. Furthermore, statistical testing on the number of SAW peak splits observed show that the second SAW peak significantly appears more frequently and is significantly different in frequency in comparison to counts and frequencies measured in unaged specimens. The ability of this technique to non-destructively detect microstructural degradation at a distance in a predictive manner in the case of CASS motivates extending gigahertz ultrasonics to detect other LWR material degradation modes as an in-vessel inspection technique, such as reactor pressure vessel (RPV) embrittlement. This allows for the greater use of NDE techniques for confident monitoring of LWR structural material health to 80 years and beyond, saving costs by minimizing structural replacements until needed and maximizing energy production by preventing early decommission until necessary.

36 MATERIALS SCIENCE↗

Gas loading apparatus for the Paris-Edinburgh press

We describe the design and operation of an apparatus for loading gases into the sample volume of the Paris-Edinburgh press at room temperature and high pressure. The system can be used for studies of samples loaded as pure or mixed gases as well as for loading gases as pressure-transmitting media in neutron-scattering experiments. The apparatus consists of a high-pressure vessel and an anvil holder with a clamp mechanism. The vessel, designed to operate at gas pressures of up to 150 MPa, is used for applying the load onto the anvils located inside the clamp. This initial load is sufficient for sealing the pressurized gas inside the sample containing gasket. The clamp containing the anvils and the sample is then transferred into the Paris-Edinburgh press by which further load can be applied to the sample. The clamp has apertures for scattered neutron beams and remains in the press for the duration of the experiment. The performance of the gas loading system is illustrated with the results of neutron-diffraction experiments on compressed nitrogen.

43 PARTICLE ACCELERATORS↗

Innovative Method for Welding in Generation 3 CSP to Enable Reliable Manufacturing of Solar Receivers to withstand Daily Cycling at Temperatures Above 700°C (Final Technical Report)

Inconel® Alloy 740H® (alloy 740H) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. Over the past ~20 years the alloy has been optimized for weldability and high-temperature stability, approved for use in different applications. Development of a supply chain combined with the advantageous properties of the alloy (high-temperature creep strength, oxidation and corrosion resistance, etc.) have resulted in the alloy being applied to new high-temperature power cycle demonstration projects, and of particular interest are applications to concentrating solar power (CSP) to enable higher-efficiency Generation 3 CSP systems and the corresponding supercritical CO 2 (sCO 2 ) power cycle components (heat exchangers, piping, etc.). The high allowable stresses of alloy 740H also make it a desirable material for current Generation 2 CSP solar power receivers to improve cyclic capability and/or reduce receiver height. Recent experiences in demonstration projects utilizing alloy 740H identified cracking issues during welding and fabrication. In this project, a detailed study was done to confirm and clarify the Stress Relaxation Cracking (SRxC) mechanism, also known as stress relief cracking or strain-age cracking (SAC), during post-weld heat-treatment (PWHT). This involved detailed microscopy and advanced characterization to understand the root cause(s) of three failures obtained from industry. Based in-part on these findings, a targeted laboratory based SRxC test method was utilized to evaluate variables such as heat-to-heat variations, strain level, PWHT temperature, and starting material condition on three heats of alloy 740H. Industrial shop welding of cold-worked plates was also conducted. The research showed the following: SRxC was confirmed as the cracking mechanism for all field failures; Stress state (from residual stresses, constraint, deformation, and local stress concentrations) was playing a significant role in field failures and laboratory testing confirmed increasing susceptibility for all heats with increasing strain levels. High levels of microstructural strain were identified at crack initiation locations, in some cases leading to local recrystallization; Precipitate free zones (PFZs) at grain boundaries were found at relaxation cracks and crack initiation locations uniquely associated with SRxC in alloy 740H. Laboratory testing reproduced this microstructural feature which had only previously been reported in long-term creep testing of weldments. Advanced nano-scale characterization confirmed the presence of a moving boundary leading to coarsening of precipitates and PFZs where damage accumulated; The research suggested heat-to-heat variations due to local chemistry and processing may influence SRxC susceptibility, but more work is needed to fully clarify these effects. To disseminate the key learnings from this research to the scientific and engineering communities and alloy 740H end users, multiple technical publications and presentations were made, an industrial alloy 740H users meeting was held, and a new industry guideline specification document which can be directly implemented by end-users of alloy 740H was produced.

14 SOLAR ENERGY↗

Nuclear characteristics of a fissioning uranium plasma test reactor with light-water cooling

An analytical study was performed to determine a design configuration for a cavity test reactor. Test section criteria were that an average flux of 10 to the 15th power neutrons/sq cm/sec (E less than or equal to 0.12 eV) be supplied to a 61-cm-diameter spherical cavity at 200-atm pressure. Design objectives were to minimize required driver power, to use existing fuel-element technology, and to obtain fuel-element life of 10 to 100 full-power hours. Parameter calculations were made on moderator region size and material, driver fuel arrangement, control system, and structure in order to determine a feasible configuration. Although not optimized, a configuration was selected which would meet design criteria. The driver fuel region was a cylindrical annular region, one element thick, of 33 MTR-type H2O-cooled elements (Al-U fuel plate configuration), each 101 cm long. The region between the spherical test cavity and the cylindrical driver fuel region was Be (10 vol. % H2O coolant) with a midplane dimension of 8 cm. Exterior to the driver fuel, the 25-cm-thick cylindrical and axial reflectors were also Be with 10 vol. % H2O coolant. The entire reactor was contained in a 10-cm-thick steel pressure vessel, and the 200-atm cavity pressure was equalized throughout the driver reactor. Fuel-element life was 50 hr at the required driver power of 200 MW. Reactor control would be achieved with rotating poison drums located in the cylindrical reflector region. A control range of about 18 percent delta k/k was required for reactor operation.

Whitmarsh, C. L., Jr.↗

Pressure measurement system for the National Transonic Facility

The electronically scanned pressure (ESP) measurement system concept was selected for application at the Langley Research Center's National Transonic Facility. This pressure measurement application required a complex system design to meet the pressure resolution, range, and accuracy requirements over this facility's wide operating pressure and temperature range of 1.38 x 10 to the 5th to 9.3 x 10 to the 5th N/sq m and 80 to 340 K, respectively. The design uses five ESP systems to measure the nearly 1000 channels of pressure located throughout the facility circuit. Pressure modules mounted inside the facility were housed in specially designed thermal enclosures, while the modules mounted outside the tunnel were mounted in pressure vessels. The unique features of this pressure measurement system design including a special ESP module pressure calibration unit are presented.

Mitchell, M.↗

Demonstration Testing for Ground Servicing of the Commercial Crew Vehicle Emergency Breathing Air Assembly

The new Commercial crew vehicle (CCV) Breathing Air Assembly (CEBAA) is a Composite Overwrapped Pressure Vessel (COPV) filled with high-pressure air, which is designed to provide portable emergency breathing air for up to five crew in the event of an ammonia leak aboard the International Space Station (ISS). Industrially, several common methods of delivering breathing air exist; however, ground processing constraints and flight requirements necessitate the more unusual approach of servicing a COPV with high purity gaseous nitrogen and oxygen serially to achieve a specific mixture of breathing air at approximately 4000 PSIA. A dwell period allows the gases to mix before sampling for composition verification. The novelty of this approach led to concerns about acceptable gas mixing and the ability to deliver accurate gas compositions. Tests examining mixing rate over a series of post-servicing dwell periods were conducted to determine the optimal time for achieving a homogeneous mixture. Further testing was conducted to examine process accuracy using temperature-pressure load criteria to target a specific concentration of oxygen and nitrogen. Test results show that while some stratification of nitrogen and oxygen was observed, a seven-day dwell is adequate time to achieve an acceptable level of mixing, and that existing ground support equipment can accurately service CEBAA COPVs to the required temperature, pressure and composition for flight.

Active Thermal↗