Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Designs of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target - Further Studies

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU dispersion targets to LEU for the production of 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier) is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitricacid concentration after dissolution will be ~1 M. The resultant solution will then be run through a column to recover Mo from other target components; the Mo will be stripped from the column with a sodium hydroxide solution that will be compatible with the current purification processes used for dispersion targets. The volume of dissolved-foil solution is assumed to be 500 mL, and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 was chosen.

Stepinski, Dominique C.↗

Incompressible flow in stepped labyrinth seals

A steped labyrinth seal was experimentally investigated to determine the effects of pressure ratio, shaft speed, number of teeth, and tooth/step location upon the leakage through the seal for incompressible flow. The dependence of the flow coefficient upon the number of throttles and pressure ratio are similar to those for straight-through labyrinth seals. It can be noted that the axial location of the throttle with respect to the step had a special effect upon the flow coefficient. That is, the dependency of the flow coefficient upon rotation rate and the number of throttles changes with axial location. It was found that the minimum flow coefficient was obtained when the seal teeth were centered on the step surface. Axial pressure distribution measurements show that when the teeth are centered on the step, the pressure drop from cavity to cavity is almost uniform. It is speculated that the obtaining of this uniform pressure gradient is the cause for the enhanced performance of the stepped labyrinth seal when operated in that configuration.

Morrison, G. L.↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

Analysis and modeling of edge fluctuations and transport mechanism in the Maryland Centrifugal Experiment

The Maryland Centrifugal Experiment [R. F. Ellis et al., Phys. Plasmas 12, 055704 (2005)] is a mirror machine designed to have a plasma axially confined by supersonic rotation and dominantly interchange stable by the radial shear in the azimuthal velocity. Nevertheless, residual fluctuations still persist. To investigate the presence of such fluctuations, an azimuthal array of 16 magnetic pickup coils at the edge region of the plasma has been employed. A comprehensive analysis of the magnetic fluctuations reveals that, under the imposed shear flow, only m=0 and m=2 modes are dominant; yet, the observed frequency spectrum is broadband. Using higher order spectral analysis, clear evidence of nonlinear mode coupling is detected. It is also observed that the amplification of magnetic fluctuations leads to enhanced transport consistent with the drop of the plasma density and voltage. As a result, the magnetic fluctuations start to decrease in amplitude as the central plasma pressure drops. In return, the anomalous radial particle and momentum transport are reduced; thus, the plasma confinement improves. As the plasma pressure starts to build up, the plasma voltage increases, destabilizing the m=2 interchange mode. The cycle of enhanced transport and intermittent fluctuations repeats itself. A two-dimensional magnetohydrodynamics code in slab geometry is employed to investigate the dynamics of the primary interchange instability and to assess the level of transport. For very low sheared rotation, a broad spatial spectrum of unstable modes is obtained. As the sheared rotation is increased, the high mode numbers become stabilized and low mode numbers dominate the spectrum. Both the experimental data obtained from the azimuthal array probes and the simulations in case of parabolic shear flow show clear evidence of nonlinear mode coupling, explaining the broadband frequency spectrum for low mode numbers. A detailed comparison of spatiotemporal dynamics of simulations with the experimental data is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion from conventional HEU dispersion targets to LEU for 99Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitric-acid concentration after dissolution will be ~1 M. The volume of solution is assumed to be 500 mL and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of a vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 is chosen.

Stepinski, D. C.↗

Large Eddy Simulation of Externally Induced Ingress about an Axial Seal by Stator Vanes

Turbine inlet temperatures in advanced gas turbines could be as high as 2000 °C. To prevent ingress of this hot gas into the wheelspace between the stator and rotor disks, whose metals can only handle temperatures up to 850 °C, rim seals and sealing flows are used. This study examines the abilities of large eddy simulation (LES) based on the WALE subgrid model and Reynolds-averaged Navier–Stokes (RANS) based on the SST model in predicting ingress in a rotor–stator configuration with vanes but no blades, a configuration with experimental data for validation. Results were obtained for an operating condition, where the ratio of the external Reynolds number to the rotational Reynolds number is 0.538. At this operating condition, both LES and RANS were found to correctly predict the coefficient of pressure, C p , located downstream of the vanes and upstream of the seal, but only LES was able to correctly predict the sealing effectiveness. This shows C p by itself is inadequate in quantifying externally induced ingress. RANS was unable to predict the sealing effectiveness because it significantly under predicted the pressure drop in the hot gas path along the axial direction, especially about the seal region. This affected the pressure difference across the seal in the radial direction, which ultimately drives ingress.

42 ENGINEERING↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

Hydraulic model of the proposed Water Recovery and Management system for Space Station Freedom

A model of the Water Recovery and Management (WRM) system utilizing SINDA '85/FLUINT to determine its hydraulic operation characteristics, and to verify the design flow and pressure drop parameters is presented. The FLUINT analysis package is employed in the model to determine the flow and pressure characteristics when each of the different loop components is operational and contributing to the overall flow pattern. The water is driven in each loop by storage tanks pressurized with cabin air, and is routed through the system to the desired destination.

Martin, Charles E.↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system's liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems, but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.6 lb. The water side and gas side pressure drops were 0.8 psid and 0.5 inches of water, respectively. Performance of the heat exchanger at the nominal pressure of 4.1 psia was measured at 94%, while a gas inlet pressure of 25 psia resulted in an effectiveness of 84%. These results compared well with the model, which was scaled for the small size. Modeling of certain phenomena that affect performance, such as flow distribution in the headers was particularly difficult due to the small size of the heat exchanger. Data from the tests has confirmed the correction factors that were used in these parts of the model.

Jennings, Mallory↗

Maximizing REE Recovery in Geothermal Systems

Rare Earth element (REE) concentrations were measure in several on-land geothermal systems, many of which boil due to pressure drop during fluid upflow in geothermal production wells. REE were also measured in several seafloor hydrothermal systems sampled at pressures above the boiling point for comparison to boiled systems. Boiling during production lowers REE concentration in fluids sampled at the well head due to changes in fluid pH and Temperature that occur during boiling that affect the solubility of REE mineral phases. Geochemical calculations using the best available thermodynamic data were preformed to extend the understanding of REE behavior beyond the systems sampled for this study. Our data and modeling show that REE concentration in geothermal fluids is controlled by solubility limits, not by concentration in the source rocks. With the exception of La and Ce, the concentration of most of the REE in geothermal fluids are less than one part per trillion. There are no reasonable scenarios under which co-production of REE from geothermal fluids used to produce energy will contribute to the economic viability of the resource.

15 GEOTHERMAL ENERGY↗

Prediction of performance of centrifugal pumps during starts under pressure

Method which calculates start-up characteristics of centrifugal pumps reveals a capacity to predict pressure drop characteristics of pumps with vaned diffusers. Calculations are based on pump geometry, design-point flow, speed, and pressure rise, and the pump characteristic within range of approximately ten percent of the design-point flow.

Rostafinski, W.↗

Internal Flow and Burning Characteristics of 16-inch Ram Jet Operating in a Free Jet at Mach Numbers of 1.35 and 1.73

The effects of mass-flow ratio on the additive drag and normal-shock position of a single oblique-shock diffuser are presented. Also evaluated is the variation with operating condition of the velocity distribution at the combustion-chamber inlet. A comparison with connected-pipe data is included. Burner performance with a corrugated gutter-grid flame holder is discussed. It is shown that the total-pressure drop across the combustion chamber can be predicted with reasonable accuracy from the computed flame holder and combustion momentum pressure losses.

DIFFUSERS, SUPERSONIC↗

Flow of Supercritical Hydrogen in a Uniformly Heated Circular Tube

Turbulent flow of supercritical hydrogen through a uniformly heated circular tube has been investigated using numerical methods, for the range of 4 x 10(exp 5) less than Re less than 3 x 10(exp 6), 5 less than or equal to q(sub W) less than or equal to 10 MW/sq m, 30 less than or equal to T(sub in) less than or equal to 90 K, and 5 less than or equal to P(sub in) less than or equal to 15 MPa. The purpose is to validate a turbulence model and calculation method for the design of active cooling systems of hydrogen-fueled hypersonic aircraft, where the hydrogen fuel a used as coolant. The PHOENICS software package was used for the computations, which required special provision for evaluation of the thermophysical properties of the supercritical hydrogen, and a low Reynolds number form of the k-epsilon turbulence model. Pressure drop and heat transfer data were compared with experiment and existing correlations and good agreement was demonstrated. For the pressure range considered here a "thermal spike" was observed and shown to be due to the secondary peak in specific heat, rather than the primary peak.

Youn, B.↗

An Assessment of Combustion Dynamics in a Low-Nox, Second-Generation Swirl-Venturi Lean Direct Injection Combustion Concept

Dynamic pressure measurements were taken during flame-tube emissions testing of three second-generation swirl-venturi lean direct injection (SV-LDI) combustor configurations. These measurements show that combustion dynamics were typically small. However, a small number of points showed high combustion dynamics, with peak-to-peak dynamic pressure fluctuations above 0.5 psi. High combustion dynamics occurred at low inlet temperatures in all three SV-LDI configurations, so combustion dynamics were explored further at low temperature conditions. A point with greater than 1.5 psi peak-to-peak dynamic pressure fluctuations was identified at an inlet temperature of 450!F, a pressure of 100 psia, an air pressure drop of 3%, and an overall equivalence ratio of 0.35. This is an off design condition: the temperature and pressure are typical of 7% power conditions, but the equivalence ratio is high. At this condition, the combustion dynamics depended strongly on the fuel staging. Combustion dynamics could be reduced significantly without changing the overall equivalence ratio by shifting the fuel distribution between stages. Shifting the fuel distribution also decreased NOx emissions.

low emissions combustors↗

Uncertainty Analysis of Experimental Discharge Coefficients in Additively Manufactured Liquid Injector Elements

Screening of two additively manufactured liquid injector designs was conducted in the UAH high pressure spray facility. Four variants of each geometry with slightly different dimensions were obtained from eleven separate commercial additive manufacturing services. The devices were manufactured from Inconel 625 using the selective laser melting (SLM) powder bed process. The devices were cold flowed with water over a range of relevant pressure drops (75 psi to 1500 psi) to produce water flow rates from 0.037 to 1.75 lbm/s into ambient back pressure. Discharge coefficients determined from the testing along with the associated uncertainties provide insight into characteristic flow performance variabilities that can be expected from the SLM process for similar geometries.

Venters, James P.↗

Mars 2020 Perseverance Rover Studies of the Martian Atmosphere Over Jezero From Pressure Measurements

The pressure sensors on Mars rover Perseverance measure the pressure field in the Jezero crater on regular hourly basis starting in sol 15 after landing. The present study extends up to sol 460 encompassing the range of solar longitudes from Ls ∼ 13°–241° (Martian Year (MY) 36). The data show the changing daily pressure cycle, the sol-to-sol seasonal evolution of the mean pressure field driven by the CO2 sublimation and deposition cycle at the poles, the characterization of up to six components of the atmospheric tides and their relationship to dust content in the atmosphere. They also show the presence of wave disturbances with periods 2–5 sols, exploring their baroclinic nature, short period oscillations (mainly at night-time) in the range 8–24 min that we interpret as internal gravity waves, transient pressure drops with duration ∼1–150 s produced by vortices, and rapid turbulent fluctuations. We also analyze the effects on pressure measurements produced by a regional dust storm over Jezero at Ls ∼ 155°.

A. Sánchez-Lavega↗

Altitude-Wind-Tunnel Investigation of a 4000-Pound-Thrust Axial-Flow Turbojet Engine: Analysis of Turbine Performance - 5

Performance characteristics of the turbine of a 4000-pound-thrust axial-flow turbojet engine was determined in investigations of the complete engine in the NACA Cleveland altitude wind tunnel. Characteristics are presented as functions of the total-pressure ratio across the turbine and of turbine speed and gas flow corrected to sea-level conditions. Three turbine nozzles of different areas were used to determine the area that gave optimum performance. Inasmuch as tail-pipe nozzles of different diameters were investigated in combination with the standard turbine nozzle, the effect of varying discharge conditions on turbine operation could be observed. The investigations covered a range of pressure attitudes from 5000 to 40,000 feet. The engine was investigated over the entire operable range of speeds at each altitude. At pressure altitude of 30,000 feet, the effect on turbine operation of varying the ram pressure ration over a range from 1.10 to 1.77 was evaluated. An altitude effect was apparent when turbine pressure ratio was plotted against corrected turbine speed but it was so slight as to be negligible insofar as the turbine efficiencies were concerned. A maximum turbine efficiency of slightly more than 82 percent was obtained with the configuration using the standard turbine nozzle and the low-flow compressor. This efficiency, which is somewhat lower than the actual turbine efficiency, is uncorrected for accessories drive power, bearing friction, tail-pipe pressure drop, compressor thermal radiation, and introduction of turbine-disk cooling air into the gas stream. Changes in the ram pressure ratio had a negligible effect on the turbine efficiency.

Krebs, Richard P.↗