Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Self-assembled hierarchical Sn3O4-multi-wall carbon nanotubes: Facile fabrication, promoted charge separation, and enhanced photocatalytic performances

Highlights: • Controlled self-assembly of Sn{sub 3}O{sub 4} nanoflakes over CNTs was achieved. • The SO-CNT-4 hybrid exhibits the best activity under visible light. • Promoted charge separation efficiency lead to the activity enhancement. - Abstract: Controlled assembling of Sn{sub 3}O{sub 4} nanoflakes over multi-wall carbon nanotubes (CNTs) was achieved for the first time by using a facile hydrothermal method. The SEM and TEM images showed that numerous Sn{sub 3}O{sub 4} nanoflakes were widely assembled over the surface of CNTs. In these hybrids, the CNTs served as dispersing-template could reduce the agglomeration of Sn{sub 3}O{sub 4} nanoflakes, as well as facilitate the interfacial charge transfer because of its high electrical conductivity. The Sn{sub 3}O{sub 4}-CNTs photocatalysts have exhibited remarkably promoted performances in decomposing organic contaminant under visible or solar light. The Sn{sub 3}O{sub 4}-CNTs hybrid with CNTs mass ratio of 4.37% exhibited the best activity under visible light, while that with CNTs mass ratio of 1.41% was more efficient when irradiated by solar light, the activity of which was about 3.47 times higher than that of pristine Sn{sub 3}O{sub 4} under identical conditions. Controlled experiments proved that O{sub 2}{sup −} and h{sup +} played the chief role in decomposing organic pollutants.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Illumina sequencing-based analysis of free-living bacterial community dynamics during an Akashiwo sanguine bloom in Xiamen sea, China

Although phytoplankton are the major source of marine dissolved organic matter (DOM), their blooms are a global problem that can greatly affect marine ecological systems, especially free-living bacteria, which are the primary DOM degraders. In this study, we analyzed free-living bacterial communities from Xiamen sea during an Akashiwo sanguine bloom using Illumina MiSeq sequencing of 16S rRNA gene amplicons. The bloom was probably stimulated by low salinity and ended after abatement of eutrophication pollution. A total of 658,446 sequence reads and 11,807 OTUs were obtained in both bloom and control samples with Alpha-proteobacteria and Gamma-proteobacteria being the predominant classes detected. The bloom decreased bacterial diversity, increased species evenness and significantly changed the bacterial community structure. Bacterial communities within the bloom were more homogeneous than those within the control area. The bacteria stimulated by this bloom included the SAR86 and SAR116 clades and the AEGEAN-169 marine group, but a few were suppressed. In addition, many bacteria known to be associated with phytoplankton were detected only in the bloom samples. This study revealed the great influence of an A. sanguinea bloom on free-living bacterial communities and provided new insights into the relationship between bacteria and A. sanguinea in marine ecosystems.

Science & Technology - Other Topics↗

Inter-Individual Variability in Human Response to Low-Dose Ionizing Radiation, Final Report

In order to investigate inter-individual variability in response to low-dose ionizing radiation, we are working with three models, 1) in-vivo irradiated human skin, for which we have a realistic model, but with few subjects, all from a previous project, 2) ex-vivo irradiated human skin, for which we also have a realistic model, though with the limitations involved in keeping skin pieces alive in media, and 3) MatTek EpiDermFT skin plugs, which provides a more realistic model than cell lines, which is more controllable than human samples.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Wall Upgrades for Residential Deep Energy Retrofits: A Literature Review

In the United States, 39% of total energy consumption comes from the building sector, 20% of which is attributed to residential buildings. New, high-performance homes incorporate a combination of tight building envelopes, mechanical ventilation and efficient components to ensure comfort, adequate airflow and moisture control. These systems work together to create energy efficient homes that employ measures to manage moisture and indoor pollutants. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established represent approximately 68% of building stock in the country, and often have significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation result in heating and cooling losses, which can represent a substantial portion of utility bills. Done correctly, deep energy retrofits (DERs) can significantly improve the energy performance of a home’s thermal envelope, decrease indoor pollutants and increase homeowner comfort. This literature review summarizes current practices for exterior wall retrofits for existing homes, provides an overview of techno-economic approaches to investigate residential wall systems, and discusses thermal and hygrothermal modeling strategies. Accompanying this literature review is a larger effort to identify state-of-the-art technologies for existing wall energy efficiency retrofit systems that can be applied over existing siding and are suitable for the cold/very cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control system for the Stirling engine

A new control system is proposed for Stirling engines. The system is based on a sealed external system for hydrogen sorption and desorption, with a thermoelectric heating and cooling system. It is intended to improve the operational reliability and the safety of the maintenance crew; to reduce the operational noise level; and to reduce the size and mass of the motor and simplify its design.

42 ENGINEERING↗

A STUDY OF EXTRACTIVE AND REMOTE-SENSING SAMPLING AND MEASUREMENT OF EMISSIONS FROM MILITARY AIRCRAFT ENGINES

Aircraft emissions contribute to the increased atmospheric burden of particulate matter (e.g., black carbon and secondary organic compounds) that plays a role in air quality, contrail formation and climate change. Sampling and measurement of modern aircraft emissions at the engine exhaust plane (EEP) for to engine and fuel certification remains a daunting task, no agency-certified method is available for the task. In this paper we summarize the results of a recent study that was devoted to investigate both extractive and optical remote-sensing (ORS) technologies in sampling and measurement of gaseous and particulate matter (PM) emitted by a number of military aircraft engines operated with JP-8 and a Fischer-Tropsch (FT) fuel at various engine conditions. These engines include cargo, bomber, and helicopter types of military aircraft that consumes 70-80% of the military aviation fuel each year. The emission indices of selected pollutants are discussed as these data may be of interest for atmospheric modeling and for design of air quality control strategies around the airports and military bases. It was found that non-volatile particles in the engine emissions were all in the ultrafine range. The mean diameter of particles increased as the engine power increased; the mode diameters were in the 20nm range for the low power condition of a new helicopter engine to 80nm for the high power condition of a newly maintained bomber engine. Elemental analysis indicated little metals were present on particles in the exhaust, while most of the materials on the exhaust particles were based on carbon and sulfate. Carbon monoxide, carbon dioxide, nitrogen oxide, sulfur dioxide, formaldehyde, ethylene, acetylene, propylene, and alkanes were detected using both technologies. The last five species (in the air toxics category) were most noticeable only under the low engine power. The emission indices calculated based on the ORS data were however observed to differ significantly (up to 90%) from (typically lower than) those based on the extractive techniques. However, the ORS techniques were useful in providing non-intrusive real-time measurements of gaseous species in the exhaust plume, which warrants further development. The results obtained in this program validate sampling methodology and measurement techniques used for non-volatile PM aircraft emissions as described in the SAE AIR-6037.

54 ENVIRONMENTAL SCIENCES↗

High Resistance of Resting Eggs of Cladoceran Moina macrocopa to the Effect of Heavy Metals

The research aimed to determine critical concentrations of heavy metals at which survival of resting eggs of the cladoceran Moina macrocopa is negatively affected. Resting eggs’ viability was not affected over a 30-days exposure towards copper, cadmium, zinc or nickel at concentrations up to 60–70 g/L. When resting eggs were exposed to sediment contaminated with heavy metals for 8 months, the hatching success was affected at 30 g copper/kg. Thus, resting eggs of Cladocera can tolerate heavy metals at concentrations that far exceed lethal concentrations of heavy metals to active life stage and exceed low or moderate levels of environmental pollution. Follow up investigation of life table parameters of hatchlings from resting eggs exposed to heavy metals demonstrated that neither lifespan nor fecundity of hatchlings differ from control animals. These results demonstrate that zooplankton may rapidly recover from resting egg bank once aquatic habitat becomes unpolluted.

54 ENVIRONMENTAL SCIENCES↗

Thermal battery for portable climate control

Current technologies that provide climate control in the transportation sector are quite inefficient. In gasoline-powered vehicles, the use of air-conditioning is known to result in higher emissions of greenhouse gases and pollutants apart from decreasing the gas-mileage. On the other hand, for electric vehicles (EVs), a drain in the onboard electric battery due to the operation of heating and cooling system results in a substantial decrease in the driving range. As an alternative to the conventional climate control system, we are developing an adsorption-based thermal battery (ATB), which is capable of storing thermal energy, and delivering both heating and cooling on demand, while requiring minimal electric power supply. Analogous to an electrical battery, the ATB can be charged for reuse. Furthermore, it promises to be compact, lightweight, and deliver high performance, which is desirable for mobile applications. In this study, we describe the design and operation of the ATB-based climate control system. We present a general theoretical framework to determine the maximum achievable heating and cooling performance using the ATB. The framework is then applied to study the feasibility of ATB integration in EVs, wherein we analyze the use of NaX zeolite-water as the adsorbent-refrigerant pair. In order to deliver the necessary heating and cooling performance, exceeding 2.5 kW h thermal capacity for EVs, the analysis determines the optimal design and operating conditions. While the use of the ATB in EVs can potentially enhance its driving range, it can also be used for climate control in conventional gasoline vehicles, as well as residential and commercial buildings as a more efficient and environmentally-friendly alternative. (C) 2015 Elsevier Ltd. All rights reserved.

Narayanan, S↗

Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The concentration of BTEX in selected urban areas of Malaysia during the COVID-19 pandemic lockdown

Volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene and xylene (BTEX) are air pollutants that harm human health. This study aims to identify BTEX concentrations before the lockdown known as the Movement Control Order was imposed (BMCO), during the implementation of the Movement Control Order (MCO), and then during the Conditional Movement Control Order (CMCO). These orders were introduced during the COVID-19 pandemic in Malaysia. The study utilised data measured by the continuous monitoring of BTEX using online gas chromatography instruments located at three urban area stations. Here, the results showed that the BTEX concentrations reduced by between –38% and –46% during the MCO compared to the BMCO period. The reduction of human mobility during the MCO and CMCO influenced the lower BTEX concentrations recorded at a station within the Kuala Lumpur area. The results of the BTEX diagnostic ratios and principal component analysis showed that the major source of BTEX, especially during the BMCO and CMCO periods, was motor vehicle emissions. Further investigation, using correlation analysis and polar plots, showed that the BTEX concentrations were also influenced by meteorological variables such as wind speed, air temperature and relative humidity.

54 ENVIRONMENTAL SCIENCES↗

Iron Speciation and Mixing in Single Aerosol Particles from the Asian Continental Outflow

Bioavailable iron from atmospheric aerosol is an essential nutrient that can control oceanic productivity, thereby impacting the global carbon budget and climate. Particles collected on Okinawa Island during an atmospheric pollution transport event from China were analyzed using complementary single particle techniques to determine the iron source and speciation. Comparing the spatial distribution of iron within ambient particles and standard Asian mineral dust, it was determined that field-collected atmospheric Fe-containing particles have numerous sources, including anthropogenic sources such as coal combustion. Fe-containing particles were found to be internally mixed with secondary species such as sulfate, soot, and organic carbon. The mass weighted average Fe(II) fraction (defined as Fe(II)/[Fe(II)+Fe(III)]) was determined to be 0.33 {+-} 0.08. Within the experimental uncertainty, this value lies close to the range of 0.26-0.30 determined for representative Asian mineral dust. Previous studies have indicated that the solubility of iron from combustion is much higher than that from mineral dust. Therefore, chemical and/or physical differences other than oxidation state may help explain the higher solubility of iron in atmospheric particles.

01 COAL, LIGNITE, AND PEAT↗

An Integrated High Pressure SOFC and Premixed Compression Ignition (PCI) Engine System

Components for a transformative, high pressure, intermediate temperature solid oxide fuel cell (SOFC) and premixed compression ignition (PCI) engine system were developed. The resulting system is a 1 MWe natural gas fueled hybrid SOFC and reciprocating internal combustion engine system capable of achieving over 70% electrical efficiency at a cost of $0.87/W. To achieve 70% electric efficiency, the SOFC system operates at 80% fuel utilization; however, when operating at this high level of fuel utilization, fuel to the engine (anode tailgas) is extremely dilute. Accordingly, a substantial portion of the effort focused on development and assessment of the combustion strategy capable of consuming this dilute fuel mixture. The engine testing effort showed that pre-chamber assisted compression ignition provides the best combination of controllability, efficiency and emissions. The engine experiments showed that high efficiency combustion can be achieved with near zero criteria pollutants. It is likely that the engine system could operate with minimal aftertreatment requirements, reducing complexity, cost, and precious metal usage. System level modeling was used to assess the overall efficiency, determine cost and efficiency tradeoffs, and demonstrate the potential to perform load following with the hybrid system. Finally, advanced manufacturing was used to demonstrate the potential to fabricate heat exchangers needed for the hybrid system from low chromium materials, which addresses the issue of chromium poisoning of the SOFC stack material.

03 NATURAL GAS↗

Our Mission to Planet Earth: A guide to teaching Earth system science

Volcanic eruptions, hurricanes, floods, and El Nino are naturally occurring events over which humans have no control. But can human activities cause additional environmental change? Can scientists predict the global impacts of increased levels of pollutants in the atmosphere? Will the planet warm because increased levels of greenhouse gases, produced by the burning of fossil fuels, trap heat and prevent it from being radiated back into space? Will the polar ice cap melt, causing massive coastal flooding? Have humans initiated wholesale climatic change? These are difficult questions, with grave implications. Predicting global change and understanding the relationships among earth's components have increased in priority for the nation. The National Aeronautics and Space Administration (NASA), along with many other government agencies, has initiated long-term studies of earth's atmosphere, oceans, and land masses using observations from satellite, balloon, and aircraft-borne instruments. NASA calls its research program Mission to Planet Earth. Because NASA can place scientific instruments far above earth's surface, the program allows scientists to explore earth's components and their interactions on a global scale.

Source record↗

An offline unstructured biogeochemical model (UBM) for complex estuarine and coastal environments

Due to increased pollutant loads and water use from coastal development and population growth, occurrences of low-dissolved oxygen and "hypoxic zones" have increased. Reports of fish kills and water quality impairment are also becoming more frequent in many coastal waters. Water quality managers and regulatory agencies rely on numerical modeling tools to quantify the relative contributions of anthropogenic and "natural" pollutant loads (nutrients and biochemical oxygen demand) on dissolved oxygen levels and use the results for remedial activities and source control. The ability to conduct seasonlong simulations with sufficient nearshore resolution is therefore a key requirement. Mesh flexibility and the ability to increase site specific resolution without disturbing the larger domain setup and calibration are critical. The objective of this effort was to develop a robust biogeochemical model suitable for simulation of water quality dynamics including dissolved oxygen in complex coastal environments with multiple tidal channels, tidal flats, and density-driven circulation using unstructured-grid formulation. This paper presents an offline unstructured biogeochemical model that uses the Finite Volume Coastal Ocean Model (FVCOM) discretization of the study domain and the corresponding hydrodynamic solution to drive biogeochemical kinetics based on a water quality model CE-QUAL-ICM. In this paper, the linkage between selected hydrodynamic and water quality models is subjected to several scalar transport and biogeochemical module tests (plume transport and dilution, BOD/DO sag, and phytoplankton/nutrients reaction), and results are compared to their analytical solutions as part of model validation. A preliminary application of the biogeochemical model with a year-long simulation of Hood Canal basin in Puget Sound, USA, is presented as an example and a test of the tool in a real estuary setting. The model reproduced the dynamics and seasonal variations in the biogeochemical state variables and was used to test short-term wind-driven dynamics that could influence dissolved oxygen concentrations in Hood Canal.

54 ENVIRONMENTAL SCIENCES↗

Development of a Residential Integrated Ventilation Controller

The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20%, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

30 DIRECT ENERGY CONVERSION↗

STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas after the repair the levels were near 0.04 mg/m3 . This does not mean that local sources in the Lab have been reduced, only that the excess of formaldehyde produced in the Lab is distributed into the whole volume of the ISS.