Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Cross strip microchannel plate imaging photon counters with high time resolution

We have implemented cross strip readout microchannel plate detectors in 18 mm active area format including open face (UV/particle) and sealed tube (optical) configurations. These have been tested with a field programmable gate array based parallel channel electronics for event encoding which can process high input event rates (> 5 MHz) with high spatial resolution. Using small pore MCPs (6 {micro}m) operated in a pair, we achieve gains of >5 x 10{sup 5} which is sufficient to provide spatial resolution of <35 {micro}m FHWM, with self triggered event timing accuracy of {approx}2 ns for sealed tube optical sensors. A peak quantum efficiency of {approx}19% at 500 nm has been achieved with SuperGenII photocathodes that have response over the 400 nm to 900 nm range. Local area counting rates of up to >200 events/mcp pore sec{sup -1} have been attained, along with image linearity and stability to better than 50 {micro}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U-Mo Plate Blister Anneal Interim Report

Blister thresholds in fuel elements have been a longstanding performance parameter for fuel elements of all types. This behavior has yet to be fully defined for the RERTR U-Mo fuel types. Blister anneal studies that began in 2007 have been expanded to include plates from more recent RERTR experiments. Preliminary data presented in this report encompasses the early generations of the U-Mo fuel systems and the most recent but still developing fuel system. Included is an overview of relevant dispersion fuel systems for the purposes of comparison.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coherent x-ray diffraction imaging of paint pigmentparticles by scanning a phase plate modulator

We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hot Isostatic Press Manufacturing Process Development for Fabrication of RERTR Monolithic Fuel Plates

We use experimentation and finite element modeling to study a Hot Isostatic Press (HIP) manufacturing process for U-10Mo Monolithic Fuel Plates. Finite element simulations are used to identify the material properties affecting the process and improve the process geometry. Accounting for the high temperature material properties and plasticity is important to obtain qualitative agreement between model and experimental results. The model allows us to improve the process geometry and provide guidance on selection of material and finish conditions for the process strongbacks. We conclude that the HIP can must be fully filled to provide uniform normal stress across the bonding interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulsed X-ray Characterization of Stripline Micro-Channel Plate Gated Imager

We report on characterization of x-ray imaging arrays developed by National Security Technologies, LLC. These devices are based on a microchannel plate (MCP) with a conventional glass microchannel structure, but the top and bottom conductive coatings, rather than covering the entire area, are configured into several (4 to 8) parallel strips. Since the bias voltage is a pulse launched from one end, these operate as striplines; relative delays between these pulses give different active exposure times. Unlike the case of a static bias voltage, non-uniformities in impedance along a stripline will produce spatial fluctuations in the bias voltage. These are expected to be slight, but the very sensitive dependence of gain on voltage - approximately like Vl/4d, where l and d are the length and diameter of the channel - means there may be very significant spatial non-uniformities in gain. Flat-field calibrations are therefore required so that such effects can be unfolded from the raw images if quantitative data is required. Such flat-field and other characterization measurements, e.g. responsivity and linearity, have therefore been done with a flash X-ray radiographic system. The maximum endpoint energy is 500 keV. The duration is {approx}40 ns, and so is essentially flat (temporally) during the MCP stripline transit time, which is a maximum of 600 ps. Spatial variations are significant, but the data are corrected using independent flat-field measurements. A monochromator selects a particular X-ray transition line (typically K{alpha}) of the anode material, so that characterizations can be done for various well-defined input photon energies.

47 OTHER INSTRUMENTATION↗

Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dimensionless parameters to categorize the failure modes of ductile plate perforation

In this work, two dimensionless parameters were derived organically from impact mechanics equations to remove the need for empirical constants. These two dimensionless parameters effectively collapse the ballistic performance of ductile metal plates along two distinct loci, depending on the projectile geometry and the corresponding failure mode. Projectiles that initiate ductile hole enlargement via cavity expansion fall along a linear curve, while shear-plugging failure modes tend to fall along a cubic curve. Results were demonstrated for various projectiles of different calibers impacting aluminum and Ti-6Al-4V alloys, and further explored for more complex target combinations. The main advantage of the approach in this work is to drastically reduce the number of features for input into machine learning algorithms.

36 MATERIALS SCIENCE↗

Next Generation IGBT Switch Plate Development for the SNS High Voltage Converter Modulator

The RF source High Voltage Converter Modulator (HVCM) systems installed on the Spallation Neutron Source (SNS) have operated well in excess of 200,000 hours, during which time numerous failures have occurred. An improved Insulated Gate Bipolar Transistor (IGBT) switch plate is under development to help mitigate these failures. The new design incorporates two significant improvements. The IGBTs are upgraded to 4500 V, 1200 A, press-pack devices, which increase the voltage margin, facilitate better cooling, and eliminate explosive disassembly of the package in the event of device failure. The upgrade to an advanced IGBT gate drive circuit decreases switching losses and improves fault-condition response. The upgrade design and development status will be presented.

43 PARTICLE ACCELERATORS↗

Nuclear Fuel Plate Fabrication Employing Friction Welding

This paper provides an overview of the friction bonding process, a novel modification of the more conventional friction stir welding process. The process has been modified to enable the fabrication of plate-type nuclear fuels for the conversion of research and test reactors currently operating using highly enriched uranium to low-enriched uranium. Discussions related to the specific modifications of the friction bonding process have been provided, in addition to challenges associated with these modifications. Progression of the process and solutions to the challenges are provided so that users of the friction stir welding process and those investigating fabrication of other laminar composites, where joining of one or more layers is essential, might draw from the authors’ experiences discussed in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint measurement of the atmospheric muon flux through the Puy de Dome volcano with plastic scintillators and Resistive Plate Chambers detectors

The muographic imaging of volcanoes relies on the measured transmittance of the atmospheric muon flux through the target. An important bias affecting the result comes from background contamination mimicking a higher transmittance. The MU-RAY and TOMUVOL collaborations measured independently in 2013 the atmospheric muon flux transmitted through the Puy de Dôme volcano using their early prototype detectors, based on plastic scintillators and on Glass Resistive Plate Chambers, respectively. These detectors had three (MU-RAY) or four (TOMUVOL) detection layers of 1 m 2 each, tens (MU-RAY) or hundreds (TOMUVOL) of nanosecond time resolution, a few millimeter position resolution, an energy threshold of few hundreds MeV, and no particle identification capabilities. The prototypes were deployed about 1.3 km away from the summit, where they measured, behind rock depths larger than 1000 m, remnant fluxes of 1.83±0.50(syst)±0.07(stat) m –2 d –1 deg –2 (MU-RAY) and 1.95±0.16(syst)±0.05(stat) m –2 d –1 deg –2 (TOMUVOL), that roughly correspond to the expected flux of high-energy atmospheric muons crossing 600 meters water equivalent (mwe) at 18° elevation. This implies that imaging depths larger than 500 mwe from 1 km away using such prototype detectors suffer from an overwhelming background. These measurements confirm that a new generation of detectors with higher momentum threshold, time-of-flight measurement, and/or particle identification is needed. As a result, the MU-RAY and TOMUVOL collaborations expect shortly to operate improved detectors, suitable for a robust muographic imaging of kilometer-scale volcanoes.

79 ASTRONOMY AND ASTROPHYSICS↗

A new algorithm for three‐dimensional joint inversion of body wave and surface wave data and its application to the Southern California plate boundary region

Abstract We introduce a new algorithm for joint inversion of body wave and surface wave data to get better 3‐D P wave ( V p ) and S wave ( V s ) velocity models by taking advantage of the complementary strengths of each data set. Our joint inversion algorithm uses a one‐step inversion of surface wave traveltime measurements at different periods for 3‐D V s and V p models without constructing the intermediate phase or group velocity maps. This allows a more straightforward modeling of surface wave traveltime data with the body wave arrival times. We take into consideration the sensitivity of surface wave data with respect to V p in addition to its large sensitivity to V s , which means both models are constrained by two different data types. The method is applied to determine 3‐D crustal V p and V s models using body wave and Rayleigh wave data in the Southern California plate boundary region, which has previously been studied with both double‐difference tomography method using body wave arrival times and ambient noise tomography method with Rayleigh and Love wave group velocity dispersion measurements. Our approach creates self‐consistent and unique models with no prominent gaps, with Rayleigh wave data resolving shallow and large‐scale features and body wave data constraining relatively deeper structures where their ray coverage is good. The velocity model from the joint inversion is consistent with local geological structures and produces better fits to observed seismic waveforms than the current Southern California Earthquake Center (SCEC) model.

Fang, Hongjian↗

Enhanced Electrolyte Transport and Kinetics Mitigate Graphite Exfoliation and Li Plating in Fast–Charging Li–Ion Batteries

Despite significant progress in energy retention, lithium-ion batteries (LIBs) face untenable reductions in cycle life under extreme fast-charging (XFC) conditions, which primarily originate from a variety of kinetic limitations between the graphite anode and the electrolyte. Through quantitative Li + loss accounting and comprehensive materials analyses, it is directly observed that the operation of LIB pouch cells at 4 C||C/3 (charging||discharging) results in Li plating, disadvantageous solid-electrolyte-interphase formation, and solvent co-intercalation leading to interstitial decomposition within graphite layers. It is found that these failure modes originate from the insufficient properties of conventional electrolytes, where employing a designed ester-based electrolyte improved the capacity retention of these cells from 55.9% to 88.2% after 500 cycles when operated at the aforementioned conditions. These metrics are the result of effective mitigation of the aforementioned failure modes due to superior Li + transport and desolvation characteristics demonstrated through both experimental and computational characterization. Finally, this work reveals the vital nature of electrolyte design to XFC performance.

25 ENERGY STORAGE↗

Evaluating Pressure‐dependent Discharge Behavior of Foil Versus In situ Plated Lithium Metal Anodes in Solid‐State Batteries

Abstract Anode‐free manufacturing of solid‐state batteries (SSBs) shows promise to maximize energy density by eliminating excess lithium (Li) and simplifying battery production. However, high reversibility during discharge (stripping of Li) is necessary for long‐lifetime SSBs with a limited Li reservoir. Further, the plastic flow of Li changes depending on the Li thickness, leading to possible differences in discharge performance under stack pressure. This work investigates the pressure‐dependent discharge performance of anode‐free manufactured SSBs with in situ plated Li and compares the performance to that of conventional thick Li foil cells. Distinct stripping behavior is observed at low pressures (0–1 MPa), where Li diffusivity and initial interfacial contact may control accessible capacity, compared to high pressures (3–10 MPa) where mechanical deformation of Li likely governs stripping behavior. Analysis of impedance spectra collected during stripping shows that additional stack pressure delays the formation of deep, as opposed to lateral, voids in the Li anode. These results provide insights to guide the transition from thick Li foil anodes to anode‐free manufactured SSBs.

Haslam, Catherine G.↗

Photon to plate: A holistic view of photosynthetic and anthropogenic energy fluxes

Modern agriculture couples photosynthetic energy with human-applied energy supplements (e.g., fertilizers, labor, cultivation) to feed a growing population. These energy supplements usually come from fossil fuels, presenting an opportunity to decrease fossil fuel required per calorie by improving photosynthetic efficiency. To quantify how improving photosynthetic efficiency would decrease the supplemental energy needed per calorie, we present a “photon to plate” life cycle analysis of energy flows (photosynthetic and human-applied) needed to produce fresh-cut fries. Our results show that photosynthetic inefficiencies require ~80 times the energy used to cultivate, harvest, transport and prepare fries for consumption and that improvements to photosynthesis could reduce the energy applied by humans per calorie by almost 40%. This study highlights the magnitude of energy used during photosynthesis and the potential for photosynthetic improvements to increase agricultural sustainability.

60 APPLIED LIFE SCIENCES↗

Multi-Instrument Characterization of the Surfaces and Materials in Microfabricated, Carbon Nanotube-Templated Thin Layer Chromatography Plates. An Analogy to ‘The Blind Men and the Elephant’

Herein we apply a suite of surface/materials analytical tools to characterize some of the materials created in the production of microfabricated thin layer chromatography plates. Techniques used include X-ray photoelectron spectroscopy (XPS), valence band spectroscopy, static time-of-flight secondary ion spectrometry (ToF-SIMS) in both positive and negative ion modes, Rutherford backscattering spectroscopy (RBS), and helium ion microscopy (HIM). Materials characterized include: the Si(100) substrate with native oxide: Si/SiO2, alumina (35 nm) deposited as a diffusion barrier on the Si/SiO2: Si/SiO2/Al2O3, iron (6 nm) thermally evaporated on the Al2O3: Si/SiO2/Al2O3/Fe, the iron film annealed in H2 to make Fe catalyst nanoparticles: Si/SiO2/Al2O3/Fe(NP), and carbon nanotubes (CNTs) grown from the Fe nanoparticles: Si/SiO2/Al2O3/Fe(NP)/CNT. The Fe thin films and nanoparticles are found in an oxidized state. Some of the analyses of the CNTs/CNT forests reported appear to be unique: the CNT forest appears to exhibit an interesting ‘channeling’ phenomenon by RBS, we observe an odd-even effect in the ToF-SIMS spectra of Cn- species for n = 1 – 6, with ions at even n showing greater intensity than the neighboring signals, and ions with n ≥ 6 showing a steady decrease in intensity, and valence band characterization of CNTs using X-radiation is reported. The information obtained from the combination of the different analytical tools provides a more complete understanding of our materials than a single technique, which is analogous to the story of ‘The Blind Men and the Elephant’. (Of course there is increasing emphasis on the use of multiple characterization tools in surface and materials analysis.) The raw XPS and ToF-SIMS spectra from this study will be submitted to Surface Science Spectra for archiving.

Environmental Molecular Sciences Laboratory↗