Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

New Precise Measurement of the Pion Weak Form Factors in pi{sup +}->e{sup +}nugamma Decay

We have measured the pi{sup +}->e{sup +}{nu}{gamma} branching ratio over a wide region of phase space, based on a total of 65 460 events acquired using the PIBETA detector. Minimum-{chi}{sup 2} fits to the measured (E{sub e}{sup +}, E{sub {gamma}}) energy distributions result in the weak form factor value of F{sub A}=0.0119(1) with a fixed value of F{sub V}=0.0259. An unconstrained fit yields F{sub V}=0.0258(17) and F{sub A}=0.0117(17). In addition, we have measured a=0.10(6) for the dependence of F{sub V} on q{sup 2}, the e{sup +}{nu} pair invariant mass squared, parametrized as F{sub V}(q{sup 2})=F{sub V}(0)(1+aq{sup 2}). The branching ratio for the kinematic region E{sub {gamma}}>10 MeV and {theta}{sub e}{sup +}{sub {gamma}}>40 deg. is measured to be B{sup expt}=73.86(54)x10{sup -8}. Earlier deviations we reported in the high-E{sub {gamma}}-low-E{sub e}{sup +} kinematic region are resolved without a tensor term. We also derive new values for the pion polarizability {alpha}{sub E}=2.78(10)x10{sup -4} fm{sup 3} and neutral pion lifetime {tau}{sub {pi}}{sub 0}=(8.5+-1.1)x10{sup -17} s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS: Present status, limitations, and upgrade plans

An overview of the CMS upgrade plans will be presented. A brief status of the CMS detector will be given, covering some of the issues we have so far experienced. This will be followed by an overview of the various CMS upgrades planned, covering the main motivations for them, and the various R&D efforts for the possibilities under study. The CMS detector has been working extremely well since the start of data-taking at the LHC as is evidenced by the numerous excellent results published by CMS and presented at this workshop and recent conferences. Less well documented are the various issues that have been encountered with the detector. In the spirit of this workshop I will cover some of these issues with particular emphasis on problems that motivate some of the upgrades to the CMS detector for this decade of data-taking. Though the CMS detector has been working extremely well and expectations are great for making the most of the LHC luminosity, there have been a number of issues encountered so far. Some of these have been described and while none currently presents a problem for physics performance, some of them are expected to become more problematic, especially at the highest Phase 1 luminosities for which the majority of the integrated luminosity will be collected. These motivate upgrades for various parts of the CMS detector so that the current excellent physics performance can be maintained or even surpassed in the realm of the highest Phase 1 luminosities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated plan for LArTPC neutrino detectors in the US

We present an integrated R&D plan aimed at demonstrating the ability to build a very large Liquid Argon Time Projection Chamber (LArTPC), on a scale suitable for use as a Far Detector for the LBNE neutrino oscillation experiment. This plan adopts current LArTPC R&D-related activities and proposes new ones to address questions that go beyond those being answered by the current efforts. We have employed a risk evaluation strategy to identify questions that can be answered (or risks that can be mitigated) through one or more R&D steps. In summary form, the plan consists of the following pre-existing components: (1) The Materials Test Stand program, now in operation at Fermilab, addressing questions pertaining to maintenance of argon purity; (2) Existing electronics test stands at FNAL and BNL; (3) The Liquid Argon Purity Demonstrator (LAPD) now being assembled at Fermilab; (4) The ArgoNeuT prototype LArTPC, now running in the NuMI beam; (5) The MicroBooNE experiment, proposed as a physics experiment that will advance our understanding of the LArTPC technology, now completing its conceptual design phase; (6) A software development effort that is well integrated across present and planned LArTPC detectors. We are proposing to add to these efforts the following: (1) A membrane cryostat mechanical prototype to evaluate and gain expertise with this technology; (2) An installation and integration prototype, to understand issues pertaining to detector assembly, particularly in an underground environment; (3) A {approx} 5% scale electronics systems test to understand system-wide issues as well as individual component reliability. (4) A calibration test stand that would consist of a small TPC to be exposed to a test beam for calibration studies, relevant for evaluation of physics sensitivities. We have developed a timeline and milestones for achieving these goals as discussed in Section 4. The proposed activities necessary for the final design of LAr20 are complete by CD3 in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of CP violation in $B_s^0\to J/\psi \phi$ decays using the full CDF data set

We report on the final measurement of the CP-violating $B_s^0$ mixing phase $\beta_s^{J/ψφ}$ in √s = 1.96 TeV proton-antiproton collisions collected with the Collider Detector at the Fermilab Tevatron collider. Using a sample corresponding to 9.6 fb -1 of integrated luminosity, we fit the decay-time evolution of $B_s^0$ → J/ψ (→ μ + μ - ) φ (→ K + K ₋ ) decays in which the b-quark content at production and the CP parity of the final state are identified. The interference of decays with and without mixing renders the $B_s^0$ mixing phase observable. The phase is determined to be -0.06 < $\beta_s^{J/ψφ}$ < 0.30 at 68% confidence level. The decay-width difference between heavy and light $B_s^0$ eigenstates, and the average $B_s^0$ lifetime are also determined to be ΔΓ s = 0.068 ± 0.027 ps -1 and $\tau_s$ = 1.528 ± 0.021 ps, respectively. These results are among the world’s most precise from a single experiment, and compatible with standard model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of moire fringes by Wiener filtering: An extension to the Fourier method

In X-ray Talbot interferometry, tilting the phase grating with respect to the absorption grating results in the formation of spatial fringes. The analysis of this moire pattern, classically performed by the Fourier method, allows the extraction of the sample phase shift information from a single image. In this context, an extension to the Fourier method is proposed. The filter used to extract the fringe information is chosen optimally in the least-squares sense, given models for the zeroth and first order modes, noise and the modulation transfer function. The latter is obtained by measuring the detector response to moire fringes with increasing frequencies. The obtained Wiener filter allows a better reconstruction of the phase information at all fringe frequencies, compared to the usual box or gaussian filters. This is demonstrated quantitatively by experiments using synchrotron radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

43 PARTICLE ACCELERATORS↗

Phase retrieval for Bragg coherent diffraction imaging at high x-ray energies

Coherent x-ray beams with energies ≥ 50 keV can potentially enable three-dimensional imaging of atomic lattice distortion fields within individual crystallites in bulk polycrystalline materials through Bragg coherent diffraction imaging (BCDI). However, the undersampling of the diffraction signal due to Fourier-space compression at high x-ray energies renders conventional phase-retrieval algorithms unsuitable for three-dimensional reconstruction. To address this problem, we utilize a phase-retrieval method with a Fourier constraint specifically tailored for undersampled diffraction data measured with coarse-pitched detector pixels that bin the underlying signal. With our approach, we show that it is possible to reconstruct three-dimensional strained crystallites from an undersampled Bragg diffraction data set subject to pixel-area integration without having to physically upsample the diffraction signal. Using simulations and experimental results, we demonstrate that explicit modeling of Fourier-space compression during phase retrieval provides a viable means by which to invert high-energy BCDI data, which is otherwise intractable.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radiochromic film imaging spectroscopy of laser-accelerated proton beams

This article reports on an experimental method to fully reconstruct laser-accelerated proton beam parameters called radiochromic film imaging spectroscopy (RIS). RIS allows for the characterization of proton beams concerning real and virtual source size, envelope- and microdivergence, normalized transverse emittance, phase space, and proton spectrum. This technique requires particular targets and a high resolution proton detector. Therefore thin gold foils with a microgrooved rear side were manufactured and characterized. Calibrated GafChromic radiochromic film (RCF) types MD-55, HS, and HD-810 in stack configuration were used as spatial and energy resolved film detectors. The principle of the RCF imaging spectroscopy was demonstrated at four different laser systems. This can be a method to characterize a laser system with respect to its proton-acceleration capability. In addition, an algorithm to calculate the spatial and energy resolved proton distribution has been developed and tested to get a better idea of laser-accelerated proton beams and their energy deposition with respect to further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Absorption and Phase Contrast X-Ray Imaging in Paleontology Using Laboratory and Synchrotron Sources

X-ray micro-computed tomography (CT) is commonly used for imaging of samples in biomedical or materials science research. Owing to the ability to visualize a sample in a nondestructive way, X-ray CT is perfectly suited to inspect fossilized specimens, which are mostly unique or rare. In certain regions of the world where important sedimentation events occurred in the Precambrian geological time, several fossilized animals are studied to understand questions related to their origin, environment, and life evolution. This article demonstrates the advantages of applying absorption and phase-contrast CT on the enigmatic fossil Corumbella werneri, one of the oldest known animals capable of building hard parts, originally discovered in Corumba (Brazil). Different tomographic setups were tested to visualize the fossilized inner structures: a commercial laboratory-based CT device, two synchrotron-based imaging setups using conventional absorption and propagation-based phase contrast, and a commercial X-ray microscope with a lens-coupled detector system, dedicated for radiography and tomography. Based on our results we discuss the strengths and weaknesses of the different imaging setups for paleontological studies.

Corumbella werneri↗

The Search for Dark Matter with the XENON100 Experiment

The XENON Dark Matter Experiment aims at the direct detection of dark matter Weakly Interacting Massive Particles (WIMPs) with dual phase (liquid/gas) xenon time projection chambers (XeTPCs). Following the successful performance of the XENON10 detector, which has shown in 2007 the best sensitivity to spin-independent coupling of WIMPs to matter, we have designed and completed the construction of a new TPC with an active LXe shield, containing a total of 170 kg of xenon. The detector is currently undergoing final commissioning at the Gran Sasso Underground Laboratory. I will review the XENON10 results and present the status of the XENON100 experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The XENON100 Dark Matter Experiment

The XENON Dark Matter Experiment aims at the direct detection of dark matter Weakly Interacting Massive Particles (WIMPs) with dual phase (liquid/gas) xenon time projection chambers (XeTPCs). Following the successful performance of the XENON10 detector, which has shown in 2007 the best sensitivity to spin-independent coupling of WIMPs to matter, we have designed and completed the construction of a new TPC with an active LXe shield, containing a total of 170 kg of xenon. The detector is currently undergoing final commissioning at the Gran Sasso Underground Laboratory. I will review the XENON10 results and present the status of the XENON100 experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing and Modeling the Noise and Complex Impedance of Feedhorn-Coupled TES Polarimeters

We present results from modeling the electrothermal performance of feedhorn-coupled transition edge sensor (TES) polarimeters under development for use in cosmic microwave background (CMB) polarization experiments. Each polarimeter couples radiation from a corrugated feedhorn through a planar orthomode transducer, which transmits power from orthogonal polarization modes to two TES bolometers. We model our TES with two- and three-block thermal architectures. We fit the complex impedance data at multiple points in the TES transition. From the fits, we predict the noise spectra. We present comparisons of these predictions to the data for two TESes on a prototype polarimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core density gradient fluctuation measurement by differential interferometry in the helically symmetric experiment stellarator

The interferometer system on the Helically Symmetric eXperiment (HSX) stellarator uses an expanded beam and linear detector array to realize a multichord measurement. Unlike conventional interferometry which determines the plasma phase shift with respect to a reference, directly evaluating the phase between two adjacent chords can be employed to measure the change in plasma phase with impact parameter. This approach provides a measure of the equilibrium density gradient or the density gradient fluctuations and is referred to as differential interferometry. For central chords, measurements are spatially localized due to a geometrical weighting factor and can provide information on core density gradient fluctuations. The measurement requires finite coherence between fluctuations in the two spatially offset chords. This technique is applied on the HSX stellarator to measure both broadband turbulence and coherent modes. Spatial localization is exploited to isolate core turbulence changes associated with change in magnetic configuration or heating location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of muonic kaon atoms at high-energy colliders

We develop a framework for the formation of exotic muonic kaon atoms ($K\mu$) in semileptonic $D^{0}$ decays, using the effective weak Hamiltonian, a helicity-based treatment of the leptonic current, and a nonrelativistic bound-state projection. The resulting branching ratio, $\mathrm{BR}(D^{0}\!\to(K\mu )\nu_{\mu})=2.29\times10^{-10}$, is implemented in a ROOT-based code to estimate yields at RHIC, LHC, and STCF. We show quantitatively that $K\mu$ atoms—also produced through coalescence in the quark--gluon plasma (QGP)—provide a sensitive probe of low-momentum primordial muons and early-time electromagnetic radiation, offering complementary constraints in an otherwise unexplored phase space for thermal dilepton and photon emission. Newly estimated dissociation cross sections in detector material indicate that secondary‑vertex reconstruction should be experimentally feasible, allowing clean experimental identification of the atoms. Projected yields from QGP coalescence in LHC and RHIC heavy-ion collisions, and from $D^{0}$ decays in LHC high-luminosity $p+p$ collisions indicate that the first observation of $K\mu$ atoms is within reach. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Article funded by SCOAP3 and published under licence by Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Science and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗