Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERSPECTIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Advances and perspectives of hard carbon anode modulated by defect/hetero elemental engineering for sodium ion batteries

Sodium-ion batteries (SIBs) serve as a promising complement to lithium-ion batteries for large-scale energy storage, leveraging the abundance of sodium resources and notable safety advantages. The key advancement in SIB industrialization hinges on identifying a cost-effective and high-performance anode material, similar to the graphite anode in lithium-ion batteries. Hard carbon emerges as prime anode materials for SIBs, boasting high specific capacity, low sodium storage potential, and wide availability. However, practical applications of hard carbon encounters challenges such as low initial Coulombic efficiency (ICE), inadequate long-term cycling stability, and poor rate performance. Recent research has focused on the optimization of hard carbon electrodes through functional design. In this comprehensive review, we have meticulously examined the progress in enhancing sodium storage performance through microstructural modulation within hard carbon, encompassing four pivotal aspects: heteroatom doping, incorporation of oxygen functional groups, surface coating, and intrinsic defect engineering. Progress in implementing these strategies is scrutinized, while the merits and challenges of each defect engineering approach are discussed. In conclusion, this review also looks into forthcoming opportunities and challenges in the practical application process of hard carbon electrodes in SIBs.

25 ENERGY STORAGE↗

Exploring pressure-dependent inelastic deformation and failure in bonded granular composites: An energetic materials perspective

In polymer-filled granular composites, damage may develop in mechanical loading prior to material failure. Damage mechanisms such as microcracking or plastic deformation in the binder phase can substantially alter the material’s mesostructure. For energetic materials, such as solid propellants and plastic bonded explosives, these mesostructural changes can have far reaching effects including degraded mechanical properties, potentially increased sensitivity to further insults, and changes in expected performance. Unfortunately, predicting damage is nontrivial due to the complex nature of these composites and the entangled interactions between inelastic mechanisms. In this work, we assess the current literature of experimental knowledge, focusing on the pressure-dependent shear response, and propose a simple simulation framework of bonded particles to study four limiting-case material formulations at both meso- and macro-scales. Further, to construct the four cases, we systematically vary the relative interfacial strength between the polymer binder and granular filler phase and also vary the polymer’s glass transition temperature relative to operating temperature which determines how much the binder can plastically deform. These simulations identify key trends in global mechanical response, such as the emergence of strain hardening or softening regimes with increasing pressure which qualitatively resemble experimental results. By quantifying the activation of different inelastic mechanisms, such as bonds breaking and plastically straining, we identify when each mechanism becomes relevant and provide insight into potential origins for changes in mechanical responses. The locations of broken bonds are also used to define larger, mesoscopic cracks to test various metrics of damage. We primarily focus on triaxial compression, but also test the opposite case of triaxial extension to highlight the impact of Lode angle on mechanical behavior.

36 MATERIALS SCIENCE↗

Measuring pacemaker dose: A clinical perspective

Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

61 RADIATION PROTECTION AND DOSIMETRY↗

Immediate breast reconstruction with anatomical implants following mastectomy: The radiation perspective

Immediate implant-based breast reconstruction followed by postmastectomy radiation therapy (PMRT) is controversial because of the risk of compromised treatment plans and concerns regarding cosmetic outcomes. We evaluated the effects of immediate direct-to-implant breast reconstruction with anatomical implants on the quality of PMRT delivered by 3-dimensional conformal radiotherapy (3D-CRT). In this retrospective, single-institution study, patients who had undergone reconstruction with direct anatomic implant, performed by a single surgeon, received 3D-CRT between 2008 and 2013. For each patient, 2 plans (including or excluding internal mammary nodes [IMN]) were created and calculated. The primary end point was the dose distribution among reconstructed breasts, heart, lungs, and IMNs, and between right and left breasts. Of 29 consecutive patients, 11 received right-sided and 18 received left-sided PMRT to a total dose of 50 Gy. For plans excluding IMN coverage, mean D{sub mean} for right and left reconstructed breasts was 49.09 Gy (98.2% of the prescribed dose) and 48.51 Gy (97.0%), respectively. For plans including IMNs, mean D{sub mean} was 49.15 Gy (98.3%) for right and 48.46 Gy (96.9%) for left reconstructed breasts; the mean IMN D{sub mean} was 47.27 Gy (right) and 47.89 Gy (left). Heart D{sub mean} was below 1.56 Gy for all plans. Mean total lung volume receiving a dose of ≥ 20 Gy was 13.80% to 19.47%. PMRT can be delivered effectively and safely by 3D-CRT after direct-to-implant breast reconstruction with anatomical implants, even if patients require IMN treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrokinetic comparison of CaF 2 and AgCl from a MDS perspective

CaF 2 has limited electrokinetic sensitivity to fluoride ions in solution and the positive CaF 2 surface charge is not reversed at high fluoride ion concentration. Similar insensitivity of surface charge to high fluoride ion concentration has been observed for other alkali and alkaline earth fluoride salts. On the contrary, chloride ions act as potential determining ions for AgCl and reverse the surface charge, as expected. FTIR-IRS results indicate that the AgCl/water interface has a water structure-breaking tendency, whereas the CaF 2 /water interface has a structure-making tendency. Here, it is speculated that the strong hydrogen bonding between fluoride ions and water prevents the accommodation of excess fluoride ions at surface lattice sites of fluorite, and therefore explains the low sensitivity of the fluorite surface charge sign and magnitude to fluoride ion concentration. However, this speculation has not been examined at the molecular level and is evaluated by molecular dynamics simulations (MDS) in the research presented in this paper. Higher hydrogen bond density at the CaF 2 mineral/water interface confirms that the water structure has stronger hydrogen bonding at both the CaF 2 mineral surface and with the F - ion in solution. In this way, the interaction of the F - ion with the CaF 2 surface is inhibited.

36 MATERIALS SCIENCE↗

Thin-film semiconductor perspective of organometal trihalide perovskite materials for high-efficiency solar cells

Organolead trihalide perovskites (OTPs) are arising as a new generation of low-cost active materials for solar cells with efficiency rocketing from 3.5% to over 20% within only five years. From “dye” in dye sensitized solar cells to “hole conductors” and “electron conductors” in mesoscopic heterojunction solar cells, there has been a dramatic conceptual evolution on the function of OTPs in photovoltaic devices. OTPs were originally used as dyes in Gratzel cells, achieving a high efficiency above 15% which, however, did not manifest the excellent charge transport properties of OTPs. An analogy of OTPs to traditional semiconductors was drawn after the demonstration of highly efficient planar heterojunction structure OTP devices and the observation of their excellent bipolar transport properties with a large diffusion length exceeding 100 nm in CH 3 NH 3 PbI 3 (MAPbI 3 ) polycrystalline thin films. Here, this review aims to provide the most recent advances in the understanding of the origin of the high OTP device efficiency. Specifically we will focus on reviewing the progress in understanding 1) the characterization of fantastic optoelectronic property of OTPs, 2) the unusual defect physics that originate the optoelectronic property; 3) morphology control of the perovskite film from fabrication process and film post-treatment, and 4) device interface and charge transport layers that dramatically impact device efficiency in the OTP thin film devices; 5) photocurrent hysteresis; 6) tandem solar cells; 7) stability of the perovskite materials and solar cell devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoalloy catalysts inside fuel cells: An atomic-level perspective on the functionality by combined in operando x-ray spectroscopy and total scattering

We introduce an experimental approach for structural characterization of catalysts for fuel cells combining synchrotron x-ray spectroscopy and total scattering. The approach allows probing catalysts inside operating fuel cells with atomic-level precision (~ 0.02 Å) and element specificity (~ 2–3 at%) in both time (~ 1 min) and space (~ μm) resolved manner. The approach is demonstrated on exemplary Pd-Sn and Pt-Ni-Cu nanoalloy catalysts for the oxygen reduction reaction (ORR) deposited on the cathode of an operating proton exchange membrane fuel cell. In operando x-ray data show that under operating conditions, the catalyst particles can undergo specific structural changes, ranging from sub-Å atomic fluctuations and sharp nanophase transitions to a gradual strain relaxation and growth, which inflict significant losses in their ORR activity. Though triggered electrochemically, the changes are not driven solely by differences in the reduction potential and surface energy of the metallic species constituting the nanoalloys but also by the formation energy of competing nanophases, mismatch between the size of individual atomic species and their ability to interdiffuse fast in search of energetically favorable configurations. Given their complexity, the changes are difficult to predict and so the resulting ORR losses remain difficult to limit. We show that in operando knowledge of the structural evolution of nanoalloy catalysts helps create strategies for improving their activity and stability. In particular, we show that shaping Pd-Sn nanoalloys rich in Pd as cubes reduces the interdiffusion of atoms at their surface and so makes them better catalysts for ORR in fuel cells in comparison to other Pd-Sn nanoalloys. In addition, we demonstrate that the approach introduced here can provide knowledge of other major factors affecting the performance of fuel cells such as operating temperature and the overall catalyst utilization, in particular the evolution of elemental and mass distribution of catalyst particles over the cells’ cathode. Last but not least, we discuss how in operando x-ray spectroscopy and total x-ray scattering can bridge the knowledge gap between the widely used in situ SAXS, EXAFS and monocrystal surface XRD techniques for structural characterization of nanoalloy catalysts explored for energy related applications.

25 ENERGY STORAGE↗

Dosimetry User's Perspective on Covariance Needs

The dosimetry community has a critical need for covariance matrices to characterize the uncertainty in the input nuclear data used in a range of applications. This need is growing more acute as the nuclear regulatory community increases the rigor with which dosimetry statements must be made and supported. This paper presents and prioritizes a set of needs that reflect the application of neutron dosimetry to the research reactor and commercial nuclear power industry.

99 GENERAL AND MISCELLANEOUS↗

Diamond detector technology, status and perspectives

Detectors based on Chemical Vapor Deposition (CVD) diamond have been used extensively and successfully in beam conditions/beam loss monitors as the innermost detectors in the highest radiation areas of Large Hadron Collider (LHC) experiments. The startup of the LHC in 2015 brought a new milestone where the first polycrystalline CVD (pCVD) diamond pixel modules were installed in an LHC experiment and successfully began operation. The RD42 collaboration at CERN is leading the effort to develop polycrystalline CVD diamond as a material for tracking detectors operating in extreme radiation environments. The status of the RD42 project with emphasis on recent beam test results is presented.

3D diamond detectors↗

Investigation of Compton scattering for gamma beam intensity measurements and perspectives at ELI-NP

Compton γ-ray sources have been used for over 30 years with new facilities being under construction or proposed. The gamma beam system under implementation at the Extreme Light Infrastructure - Nuclear Physics facility in Romania will deliver brilliant γ-ray beams with energies up to 19.5 MeV. Several instruments for measuring the parameters of the γ-ray beam are under development at ELI-NP. One of these instruments based on a High Purity Germanium detector is typically used for beam energy measurements at other facilities. Here we investigate the use of a High Purity Germanium detector to continuously monitor the intensity of the ELI-NP gamma beam by measuring the inelastic scattering of photons. This technique relies on both experimental and simulated data and it has been successfully tested during a recent experiment at the High Intensity γ-ray Source facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perspectives on the Application of Order-Statistics in Best-Estimate Plus Uncertainty Nuclear Safety Analysis

The application of order-statistics in best-estimate plus uncertainty nuclear safety analysis has received a considerable amount of attention from methodology practitioners, regulators, and academia. At the root of the debate are two questions: (1) what is an appropriate quantitative interpretation of “high level of probability” in regulatory language appearing in the LOCA rule, 10 CFR 50.46 and (2) how best to mathematically characterize the multi-variate case. An original derivation is offered to provide a quantitative basis for “high level of probability.” At root of the second question is whether one should recognize a probability statement based on the tolerance region method of Wald and Guba, et al., for multi-variate problems, one explicitly based on the regulatory limits, best articulated in the Wallis–Nutt “Testing Method”, or something else entirely. This paper reviews the origins of the different positions, key assumptions, limitations, and relationship to addressing acceptance criteria. It presents a mathematical interpretation of the regulatory language, including a complete derivation of uni-variate order-statistics (as credited in AREVA’s Realistic Large Break LOCA methodology) and extension to multi-variate situations. Lastly, it provides recommendations for LOCA applications, endorsing the “Testing Method” and addressing acceptance methods allowing for limited sample failures.

99 GENERAL AND MISCELLANEOUS↗