Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL REFLECTIVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Effect of annealing temperature on the structure and optical parameters of Ge{sub 20}Se{sub 50}Te{sub 30} thin films

Highlights: • The amorphous nature of as prepared Ge{sub 20}Se{sub 50}Te{sub 30} films was confirmed by XRD. • The thermal annealing was found to affect the structure and optical parameter. • Thermal annealing resulted in an appearance of crystalline phases in studied films. • The average particle size increased with increasing the annealing temperature. • The indirect band gap was found to decrease with increasing annealing temperature. - Abstract: Bulk glasses and thin films of Ge{sub 20}Se{sub 50}Te{sub 30} were prepared by melt-quenching and thermal evaporation technique, respectively. The stoichiometry of the composition was checked by energy dispersive X-ray diffraction (EDX), whereas the crystallization was investigated using differential scanning calorimetery (DSC). The effect of heat treatment on the structure transformation of Ge{sub 20}Se{sub 50}Te{sub 30} films was determined by X-ray diffraction (XRD). The XRD results reveal that the as-prepared films are amorphous in nature while the annealed ones show crystalline phases. Further, the average crystallite size, strain, and dislocation density were found to depend on the annealing temperature. The optical transmittance and reflectance of the studied films at different annealing temperatures were measured using spectrophotometer. The optical parameters were calculated as a function of annealing temperature. The optical transition was found to be allowed indirect transition with optical band gap decreases from 1.69 to 1.41 eV with increasing the annealing temperature from 553 to 633 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bulk plasmons in metal-insulator superlattices

A simple model is proposed to describe the long-wavelength oscillations in metal-insulator super-lattices. In such structures, the frequency range of bulk plasmons is shown to expand substantially as compared to a homogeneous metal and to cover the optical range. Resonances related to such modes are predicted when an electromagnetic wave is reflected by an optically thin superlattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗

Linear polarization sensitivity specifications for space-borne instruments

The radiometric accuracy of space-borne instruments such as radiometers and spectroradiometers which make measurements of the earth and other celestial objects can be compromised by the linear polarization sensitivity (LPS) induced by the optical system. Most of these optical systems contain optical elements whose reflectance or transmission is polarization dependent, such as diffraction gratings, folding and scanning mirrors, dichroic filters, and optical fibers. Optical system incorporating such elements generally display linear polarization sensitivity; different linear polarization states incident with equal radiometric power will be measured as different power levels. If the incident polarization state is unknown, the linear polarization sensitivity cannot be compensated during the data reduction. The light reflected from the earth and other planets and moons is usually partially linearly polarized, but in a random distribution. Thus, to make accurate radiometric measurements of these bodies, a radiometer or spectrometer should have a low level of linear polarization sensitivity. This paper contains a mathematical description of LPS, contains references to systems which have imposed a LPS specification, describes some of the sources of LPS, describes how to model LPS by polarization ray tracing, and discusses methods to reduce the LPS of an optical system.

Maymon, Peter W.↗

High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

Parker, Allen R. Jr.↗

Ultrafast free-carrier dynamics in Cu{sub 2}ZnSnS{sub 4} single crystals studied using femtosecond time-resolved optical spectroscopy

We studied the dynamics of photogenerated carriers in Cu{sub 2}ZnSnS{sub 4} (CZTS) single crystals using femtosecond transient reflectivity (TR) and optical pump-THz probe transient absorption (THz-TA) spectroscopy. The TR and THz-TA decay dynamics consistently showed that free carriers have long lifetimes of up to a few nanoseconds. The excitation-photon-energy-dependent TR measurements revealed a slow picosecond energy relaxation of free carriers to the band edge in CZTS. The relaxation and recombination dynamics of free carriers were affected by nonradiative recombinations at the surface. Our results revealed a global feature of energy relaxation and recombination processes of free carriers in CZTS single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Cirrus Clouds From Multi-pass AVIRIS Data

The optical depth and reflectance from thin cirrus clouds are calculated from two passes of AVIRIS over a scene in Florida. One of the passes contained partial cirrus cover, the other did not. Optical depths of 0.2 were calculated and the reflectance of the cloud at 1.381 micrometers was 0.026 The detection limit for cirrus is approximately an order of magnitude less in reflectance.

Goetz, Alexander F. H.↗

Development of a Multispectral Tissue Characterization System for Optimization of an Implantable Perfusion Status Monitor for Transplanted Liver

Optimizing wavelength selection for monitoring perfusion during liver transplant requires an in-depth characterization of liver optical properties. With these, the impact of liver absorption and scattering properties can be investigated to select optimal wavelengths for perfusion monitoring. To accomplish this, we are developing a single integrating-sphere-based using a unique spatially resolved diffuse reflectance system for optical properties determination for thick samples. We report early results using a monochromatic source implementation to measure the optical properties of well characterized tissue phantoms made from polystyrene spheres and Trypan blue. The presented results show the promise of using this unique system to measure the optical properties of the tissue phantoms. We are currently in the process of implementing an automated Levenberg Marquardt fitting algorithm to determine the peak location of the diffuse reflectance profile to ensure robust computation of sample optical properties. Future work will focus on the incorporation of multispectral capability to the technique to facilitate development of more realistic liver tissue phantoms.

59 BASIC BIOLOGICAL SCIENCES↗

Total Internal Reflection of Two Lasers in a Single Planar Optical Waveguide

Multiplex biomarker quantitation is ideal for tracking the progression of a disease, but sensitive, specific, and quantitative multiplex biosensing remains challenging. We achieved total internal reflection with two lasers in a single planar optical waveguide by coupling 532 nm laser light into the diffraction grating of a waveguide and 635 nm laser light directly into the thin film of the same waveguide. We confirmed that the evanescent fields generated in the waveguide can excite two fluorescent dyes (Alexa Fluor 532 and Alexa Fluor 647) held to the surface of the waveguide through biotin-streptavidin chemistry. This sensing concept holds significant potential as a platform for multiplex biomarker detection.

47 OTHER INSTRUMENTATION↗

Survey and adjustment methods applied on an 11 axes high performance reflectometer for synchrotron radiation

At BESSY-II a new UV-and XUV optics beamline [1] has recently been setup with an in-house developed versatile reflectometer [2], [3], [4] for at-wavelength metrology on reflective and diffractive optical elements up to 4 kg mass. High precision measurements of the reflection and polarization properties are feasible by a 360° azimuthal rotation of the sample around the beam of light, where samples can be adjusted reproducibly with a novel UHV-Tripod within arc sec and μm precision. The azimuthal rotation requires an extremely high precision adjustment of the goniometer axis with respect to the incident light beam. Here we describe sophisticated methods with which we achieve nearly perfect agreement of the azimuthal rotation axis and the synchrotron beam in the 30 arc sec range. By using geodetic instruments (lasertracker, theodolite, autocollimator) the quality of the reflectometer UHV-mechanics has been characterized with respect to stiffness and radial run out with highest precision [5].

43 PARTICLE ACCELERATORS↗

Cube-Corner Retroreflector Modeling

Collection of computer programs analyzes arrays of optical cube corners used in laser ranging. Programs compute impulse-response and interference effects of reflected pulses from optical cube corners and calculates interference-effects histogram and far-field diffraction patterns.

Kirk, J. G.↗

Fixed-Angle Reflectance from Uranium Compounds and U-Bearing Minerals: Experimental Challenges to Determine the Optical Constants n and k

Fixed-angle reflectance spectroscopy using a commercial Fourier transform infrared (FTIR) spectrometer was employed to derive the optical constants n and k of several uranium compounds. This technique relies upon measurement of the quantitative reflectance R(?) spectra from a polished surface across a broad spectral range (in this case, the mid- and far-IR covering ca. 7500 to 50 cm-1) followed by application of the Kramers-Kronig transformation (KKT). Near-normal fixed-angle measurements as used in this technique require continuous reflectance spectra to as low a wavenumber value as possible. Here, we discuss some of the many challenges in measuring the far-IR and very far-IR (terahertz) spectra using an interferometric instrument, particularly those stemming from small sample sizes, typically just millimeters on a face for crystalline samples, as well as limitations due to optical components and diffraction. We apply this method to single-crystal UO2 and its mineralogical form uraninite, as well as other U-bearing minerals such as autunite [Ca(UO2)2(PO4)2·8-12H2O] and the dehydrated form of autunite, meta-autunite. In addition to the specular reflectance spectra, x-ray diffractometry was used as a confirmatory technique to analyze the surface composition of the species. Deriving the infrared optical constants for such U-bearing species (as well as other solids) will enable nondestructive detection under a variety of environmental and compositional conditions.

Uranium Minerals, infrared spectroscopy, optical c↗

Determination of surface albedos and aerosol extinction characteristics from satellite imagery

A procedure is developed for calculating atmospheric extinction characteristics (optical thickness, scattering height, single scattering albedo) and surface albedo from radiometric images made at satellite altitudes. The procedure - a fast, computerized method - is suitable for the high-volume processing of satellite imagery data and thus can be used to map temporal and spatial distributions of aerosol parameters. Based on an analytical approximate solution to the equation of radiative transfer in a plane parallel atmosphere, the procedure is primarily applicable to the 0.4-micron to 0.8-micron wavelength range for solar zenith angles from 10 deg to 60 deg, surface albedos between 0.03 and about 0.5, and atmospheric optical thicknesses from 0.2 to 2. With a step-like change in the surface albedo (for example, a seashore or river bank or other similar change of terrain), both surface reflectivity and atmospheric optical thickness can be derived from radiance measurements. In this case, the resultant optical thickness is not based on a known surface reflectivity and is in essence independent of the radiometer calibration.

Kaufman, Y. J.↗

Use of 3000 Bragg Grating Strain Sensors Distributed on Four Eight-meter Optical Fibers During Static Load Tests of a Composite Structure

This paper describes the use of a fiber optic system to measure strain at thousands of locations along optical fibers where weakly reflecting Bragg gratings have been photoetched. The optical fibers were applied to an advanced composite transport wing along with conventional foil strain gages. A comparison of the fiber optic and foil gage systems used for this test will be presented including: a brief description of both strain data systems; a discussion of the process used for installation of the optical fiber; comparative data from the composite wing test; the processes used for the location and display of the high density fiber optic data. Calibration data demonstrating the potential accuracy of the fiber optic system will also be presented. The opportunities for industrial and commercial applications will be discussed. The fiber optic technique is shown to be a valuable augmentation to foil strain gages providing insight to structural behavior previously requiring reliance on modeling.

Childers, Brooks A.↗

Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS

Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental and chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.

36 MATERIALS SCIENCE↗

Initial Studies of the Bidirectional Reflectance Distribution Function of Multi-Walled Carbon Nanotube Structures for Stray Light Control Applications

The presentation examines the application of low reflectance surfaces in optical instruments, multi-walled carbon nanotubes (MWCNTs), research objects, MWCNT samples, measurement of 8 deg. directional/hemispherical reflectance, measurement of bidirectional reflectance distribution function (BRDF), and what is current the "blackest ever black".

Butler, J. J.↗

Temporal waveguides for optical pulses

Here we discuss, temporal total internal reflection (TIR), in analogy to the conventional TIR of an optical beam at a dielectric interface, is the total reflection of an optical pulse inside a dispersive medium at a temporal boundary across which the refractive index changes. A pair of such boundaries separated in time acts as the temporal analog of planar dielectric waveguides. We study the propagation of optical pulses inside such temporal waveguides, both analytically and numerically, and show that the waveguide supports a finite number of temporal modes. We also discuss how a single-mode temporal waveguide can be created in practice. In contrast with the spatial case, the confinement can occur even when the central region has a lower refractive index.

43 PARTICLE ACCELERATORS↗