UAS Live Incursion Drills Survey

Unmanned aircraft systems (UAS/drones) are rapidly evolving and are considered an emerging threat by nuclear facilities throughout the world. Due to the wide range of UAS capabilities, members of the workforce and security/response force personnel need to be prepared for a variety of drone incursion situations. Tabletop exercises are helpful, but actual live exercises are often needed to evaluate the quick chain of events that might ensue during a real drone fly-in and the essential kinds of information that will help identify the type of drone and pilot. Even with drone detection equipment, the type of UAS used for incursion drills can have a major impact on detection altitude and finding the UAS in the sky. Using a variety of UAS, the U.S. National Nuclear Security Administration (NNSA) Office of International Nuclear Security (INS) would like to offer partners the capability of adding actual UAS into workforce and response exercises to improve overall UAS awareness as well as the procedures that capture critical steps in dealing with intruding drones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]

The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory [Slides]

Sufficient AGN-201M fuel plate material exists at Y-12 to support the development of a new, inherently safe, subcritical assembly for use in NCS training courses at ORNL. Four experiments with the ORNL subcritical assembly are possible and feasible. Future work includes the final design of the core and reflector and split table component design specifications. The ORNL Material Demonstration Facility (MDF) may be used to 3D print ORSA stand/table components and graphite reflector. Researchers will consider fuel coatings for contamination control, rather than an Al can. A visit to Y-12 will be made to determine the location of AGN fuel plates and remaining fuel transportation considerations. Final facility location will be considered

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Cross Section Measurements at the RPI LINAC [Slides]

Cold polyethylene shows adequate capacity for enhancing sub-thermal neutron flux. Cold moderator system produced high quality thermal cross section measurements. Measurements were performed for polyethylene, polystyrene, Plexiglas, yttrium hydride and beryllium and compared with ENDF/B-VIII.0 TSL evaluations. All data reduction for all measurements was finalized. Future work includes completion of necessary journal publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Intercomparison for Nuclear Accident Dosimetry Using Godiva-IV

During the week of August 22, 2022, Integral Experiment Request (IER) 538, an international blind intercomparison for nuclear accident dosimetry (NAD) exercise, was completed using the Godiva-IV critical assembly at the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). This exercise builds upon a series of experiments that include the characterization the radiation fields around Godiva (IER-147) and Flattop (IER-252) and follow up intercomparisons of dosimetry around both Godiva IV and Flattop (IER-148 and IER-253, respectively). The participants consisted of seven Department of Energy laboratories and one laboratory each from the US Navy, United Kingdom, and France. The participants of the exercise were Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Sandia National Laboratory (SNL); Savannah River Site (SRS); Hanford Site, Missions Support and Test Services (MSTS); Y-12 National Security Complex (Y-12); Naval Dosimetry Center (NDC); Atomic Weapons Establishment (AWE); and Institut de Radioprotection et de Sûreté Nucléaire (IRSN). MSTS dosimeters were included in the irradiations but not reported for evaluation. This report primarily discusses the performance of the 24 hour results submitted by participants, though available final results are briefly discussed. Information for each irradiation performed is provided for participating laboratories to produce their own final report which will be incorporated into the CED-4a report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-501 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experimental Testbed for Thermal Scattering Law Benchmarks (PNDA)

This report summarizes the experiments done for IER-501, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The PNDA experiments were conducted in two separate two-day campaigns: one campaign for high-density polyethylene and another for Lucite. All experiments were performed at Lawrence Livermore Laboratory. They will become high-quality benchmarks that serve to optimize and validate thermal neutron scattering laws (TSLs), which are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the PNDA design and its equipment, and it documents the experimental die-away curves. It presents the characterization measurements that have been performed to-date. Importantly, mass spectrometry measurements to determine sample impurities were not yet completed. These will be included in the final benchmark. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the data for the die-away curves in the appendices. The HDPE experiments examined twelve targets of varying size. The Lucite measurements included ten targets of varying size. Experimenters in the campaign were Daniel Siefman, William Zywiec, and Ruby Araj.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flattop Benchmark CED-2 (IER-423)

The final design for the Flattop HEU Core Benchmark is presented in this report. Physical measurements will be performed on Flattop components using modern instruments and techniques to define uncertainties necessary to meet contemporary ICSBEP standards. A preliminary re-evaluation of ICSBEP HMF-0028 (Flattop HEU Core) led to the development of IER-423 CED-1, wherein total relative uncertainties in $k_{eff}$ were provided based on a new detailed model. The estimated uncertainty on the total uncertainty is +100%/-0%, given a lack of documented uncertainties on mass, dimensions, and densities of predominantly the natural uranium (NU) and highly enriched uranium (HEU) components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission TPC cross section ratio results [Abstract]

The fission TPC was designed for precision fission cross section ratio measurements. The high-fidelity 3D particle tracking data is used to conduct a detailed analysis of the uncertainty contributions. In this contribution a brief overview of the instrument was presented. The results of the 238 U(n,f)/ 235 U(n,f) cross section ratio measurement published in [Phys. Rev C 97, 034618 (2018)] were reviewed and the preliminary status of the 239 Pu(n,f)/ 235 U(n,f) cross section ratio measurement was shown.

238U(n,f)/235U(n,f) cross section ratio↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specification of EBR-II Gamma Scan Data from the Precision Gamma Scanner

The gamma scan data stored in the FIPD was originally measured using the Precision Gamma Scanner (PGS) at the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). This system was originally manufactured in 1971 (when the facilities, now at INL, were operated by Argonne National Laboratory) and was upgraded on several occasions. It consists of a germanium gamma ray detector (the exact nature of which changed over time as technology improved), a variable-slit collimator that blocks the view of gamma emissions from all but the selected area of the target, and a computer-controlled system for translating a sample past the slit and logging the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.