Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SU-F-J-225: Histology Study of MR Guided Pulsed Focused Ultrasound On Treatment of Prostate Cancer in Vivo

Purpose: Our previous study demonstrated significant tumor growth delay in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. The temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level using the DAB analysis software. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality may synergize with PARP inhibitors to achieve better therapeutic result.

60 APPLIED LIFE SCIENCES↗

Steam distribution and energy delivery optimization using wireless sensors

The Extreme Measurement Communications Center at Oak Ridge National Laboratory (ORNL) explores the deployment of a wireless sensor system with a real-time measurement-based energy efficiency optimization framework in the ORNL campus. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize the energy delivery within the steam distribution system. We address the goal of achieving significant energy-saving in steam lines by monitoring and acting on leaking steam valves/traps. Our approach leverages an integrated wireless sensor and real-time monitoring capabilities. We make assessments on the real-time status of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observe the state measurements of these sensors. Our assessments are based on analysis of the wireless sensor measurements. We describe Fourier-spectrum based algorithms that interpret acoustic vibration sensor data to characterize flows and classify the steam system status. We are able to present the sensor readings, steam flow, steam trap status and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Variability of Gross Tumor Volume Delineation in Head-and-Neck Cancer Using PET/CT Fusion, Part II: The Impact of a Contouring Protocol

The purpose of this study was to assess the efficacy of a gross tumor volume (GTV) contouring protocol on interobserver variability between 4 physicians in positron emission therapy/computed tomography (PET/CT) treatment planning of head-and-neck cancer. A GTV contouring protocol for PET/CT treatment planning was developed utilizing 4 stages: Preliminary contouring on CT alone, determination of appropriate PET windowing, accurate image registration, and modification of CT contouring with correctly formatted PET/CT display and rules for modality disagreement. Two neuroradiologists and 2 radiation oncologists (designated as A, B, C, and D, respectively) were given a tutorial of PET/CT coregistered imaging individualized to their skill level, which included a step-by-step explanation of the protocol with clinical examples. Opportunities for questions and hands-on practice were given. The physicians were asked to re-contour 16 head-and-neck patients from Part I on PET/CT fusion imaging. Differences in volume magnitude were analyzed for statistical significance by analysis of variance (ANOVA) and paired t-tests ({alpha} < 0.05). Volume overlap was analyzed for statistical significance using Wilcoxon signed-rank tests ({alpha} < 0.05). Volume overlap increased significantly from Part I to Part II (p < 0.05). One previously significant difference between physicians disappeared with the protocol in place. The mean fusion volume of Physician C, however, remained significantly larger than that of Physician D (p < 0.01). This result is unchanged from Part I. The multidisciplinary contouring protocol significantly improved the coincidence of GTVs contoured by multiple physicians. The magnitudes of the volumes showed marginal improvement in consistency. Developing an institutional contouring protocol for PET/CT treatment planning is highly recommended to reduce interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multicenter Retrospective Analysis of Survival Outcome Following Postoperative Chemoradiotherapy in Non-Small-Cell Lung Cancer Patients With N2 Nodal Disease

Purpose: To retrospectively evaluate the role of postoperative chemoradiotherapy (POCRT) in patients with completely resected non-small-cell lung cancer (NSCLC) with N2 lymph node involvement. Methods and Materials: This study included 183 patients from four centers in southwest China who underwent radical section of Stage III-N2 NSCLC without any preoperative therapy. One hundred and four were treated with POCRT and 79 with postoperative chemotherapy (POCT) alone. The median radiation dose to clinical target volume (CTV) was 50 Gy (varying between 48 and 54 Gy), whereas the cycles of platinum-based chemotherapy ranged from two to six with a median of four. Results: The median duration of follow-up was 72 months. The 5-year overall survival rate (OS) was 30.5% in the POCRT group, and 14.4% in the POCT group (p = 0.007). The 5-year disease-free survival rate (DFS) was 22.2% in POCRT group and 9.3% in POCT group (p = 0.003). In a multivariate analysis, N1 nodal involvement (N1+/N2+) was associated with significantly worse OS (HR = 1.454, 95% CI, 1.012-2.087, p = 0.043) and DFS (HR = 1.685, 95% CI, 1.196-2.372, p = 0.003). Absence of radiotherapy and treatment with fewer than three cycles of chemotherapy both were poor prognostic factors for both OS and DFS. Conclusions: As compared with chemotherapy alone, adjuvant treatment with both radiotherapy and chemotherapy improves survival in patients with completely resected Stage III-N2 nodal disease in NSCLC. Future study of treatment modality with radiotherapy and chemotherapy is warranted, especially focusing on both N1 and N2 nodal status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Artificial Intelligence/Machine Learning Technologies for Advanced Reactors (Workshop Summary Report)

A workshop on artificial intelligence and machine learning (AI/ML) for advanced reactors (AR) was held October 5-6, 2021. The workshop was to be attended in-person at ANL but COVID restrictions forced the workshop to go virtual. The objectives of the workshop were to identify the most promising AI/ML opportunities for improving advanced reactor design, optimizing plant performance, and enhancing economic competitiveness and to develop an understanding of the scientific, engineering and licensing challenges facing their application. The workshop planning committee included GAIN, EPRI and NEI and members of three national laboratories (ANL, INL, and ORNL). The workshop was attended by more than 200 individuals representing academic and scientific institutions and the nuclear power industry. The definition put forth for an AI/ML system was one that perceives its environment and takes actions that maximize its chance of achieving its goals. In this report AI/ML refers to next generation algorithms that include deep learning, statistical analysis and data analytics and associated scientific computing and their potential application to the design, licensing, operation and maintenance of ARs. These methods typically incorporate models built from process data and may also include data generated by simulations that represent the behavior of a system. The workshop was organized in response to the growing interest in application of AI/ML for improving the economic competitiveness of nuclear energy. Increasingly more resources are being allocated to investigating the benefits of AI/ML methods. The DOE created the Artificial Intelligence & Technology Office to promote their development. And within the Office of Nuclear Energy, resources have been allocated to explore and understand the potential benefits of AI/ML. Additionally, the national laboratories are strategically positioned with DOE computing facilities such as Summit, Perlmutter, Aurora and Frontier that support large-scale simulations, hybrid HPC models with AI surrogates, and the exploration of new types of generative models emerging from multi-model data streams and sources. The workshop was organized with members of the AR community to understand the effort and to identify the level of interest and progress in this emerging technology. The workshop discussions focused on identifying opportunities for AI/ML across diverse areas of the nuclear industry and identifying current scientific and engineering challenges for advanced reactors that might be addressed through transformational uses of AI/ML. Discussion panels focused on four high-interest technical domains for advanced reactors: design, maintenance and operations, energy storage, and materials. The results of those discussions are summarized in this report. This includes opportunities that were identified for exploiting AI techniques and methods to improve the efficacy and efficiency of reactor analysis and to improve the operation and optimization of advanced reactors. Advanced reactor developers expressed an interest in learning more about AI/ML methods and their application. This included understanding whether ML methods can provide an advantage over existing nonlinear data regression methods for collapsing high-fidelity simulation results into faster running models. A consensus emerged that AR advances planned for the next decade will benefit from the use of AI/ML tools. The need exists to understand and model complex systems across length scales and modalities. AI/ML is a tool for discovery that can yield a set of engineering principles for use by nuclear engineers, licensing bodies, and operators to solve problems in plant design, safety analyses, autonomous operation, and predictive maintenance. While AI/ML represents a new set of tools, an awareness by the nuclear community of the full potential is still in the early stages so there is a need to increase awareness. It appears that the wide-spread adoption of AI/ML tools for ARs would be facilitated by future educational workshops that describe foundational methods and capabilities and describe successful applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

What Is the Optimal Treatment of Large Brain Metastases? An Argument for a Multidisciplinary Approach

Purpose: Single-modality treatment of large brain metastases (>2 cm) with whole-brain irradiation, stereotactic radiosurgery (SRS) alone, or surgery alone is not effective, with local failure (LF) rates of 50% to 90%. Our goal was to improve local control (LC) by using multimodality therapy of surgery and adjuvant SRS targeting the resection cavity. Patients and Methods: We retrospectively evaluated 97 patients with brain metastases >2 cm in diameter treated with surgery and cavity SRS. Local and distant brain failure (DF) rates were analyzed with competing risk analysis, with death as a competing risk. The overall survival rate was calculated by the Kaplain-Meier product-limit method. Results: The median imaging follow-up duration for all patients was 10 months (range, 1-80 months). The 12-month cumulative incidence rates of LF, with death as a competing risk, were 9.3% (95% confidence interval [CI], 4.5%-16.1%), and the median time to LF was 6 months (range, 3-17 months). The 12-month cumulative incidence rate of DF, with death as a competing risk, was 53% (95% CI, 43%-63%). The median survival time for all patients was 15.6 months. The median survival times for recursive partitioning analysis classes 1, 2, and 3 were 33.8, 13.7, and 9.0 months, respectively (p = 0.022). On multivariate analysis, Karnofsky Performance Status ({>=}80 vs. <80; hazard ratio 0.54; 95% CI 0.31-0.94; p = 0.029) and maximum preoperative tumor diameter (hazard ratio 1.41; 95% CI 1.08-1.85; p = 0.013) were associated with survival. Five patients (5%) required intervention for Common Terminology Criteria for Adverse Events v4.02 grade 2 and 3 toxicity. Conclusion: Surgery and adjuvant resection cavity SRS yields excellent LC of large brain metastases. Compared with other multimodality treatment options, this approach allows patients to avoid or delay whole-brain irradiation without compromising LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Suspension System for the Road Transportation of Cryomodule SSR1 through a Multilevel Finite Element-Multibody Approach

The on-road transportation of cryomodules (CM) is a critical phase during which the structure may be subject to relevant dynamic loading. Thus, an accurate design of Transportation Tool (TT), equipped with a proper suspension system, is mandatory. In this paper the TT design for the PIP-II proto SSR1 CM is presented. A finite element (FE) model was developed considering the main CM parts. However, the full model was not suited for the design of the suspension system because of its computational time. Thus, it was exported as a Modal Neutral File to a multibody (MB) software, where minor components were modeled as rigid bodies or lumped stiffnesses. The reduced MB model considerably shortened the computational time and it was exploited for the design of the TT, which includes helical isolators (HI) acting as a mechanical filter. A real 3D acceleration profile, acquired during the transportation of a LCLS-II CM from Fermilab to SLAC, was used to validate the TT effectiveness in reducing the vibrational loading. In addition, the results of the MB analysis were used to perform FE analysis of critical components, such as bellows.

43 PARTICLE ACCELERATORS↗

Monitoring of mechanical changes in a pipe assembly with complex geometry using multi-mode acoustic signals

Guided wave ultrasonic testing has been widely used for nondestructive and long-range evaluation of diverse mechanical structures, such as pipes and plates. In general, a large number of guided wave modes exist even in the simplest geometries, and they exhibit highly dispersive characteristics. Thus, sophisticated excitation methods and elaborate modal analyses need to be implemented to excite, acquire, and process well-defined pure modes as part of such a measurement method. If the interrogated structure has complex geometry, for example, with cross-sectional variations or multiple joints, the utilization of pure modes becomes significantly more difficult. To overcome this difficulty, this paper proposes the use of multi-mode, multi-frequency guided waves for long-range inspection of structures with arbitrarily complex geometries. Furthermore, using broadband chirp signals and multi-mode time–frequency analysis in a prototypical complex pipe assembly that includes multiple pipe diameters, elbows, and flange connections, we experimentally show sensitive detection of mechanical changes (both material addition and loss). In addition, we demonstrate that the complexity of the structure can be modeled in the digital domain with sufficient detail to allow accurate numerical simulation of the acoustic response using this method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural color from a coupled nanowire pair beyond the bonding and antibonding model

Optical resonances in nanostructures can be harnessed to produce a wide range of structural colors. Conversely, the analysis of structural colors has been used to clarify the nature of optical resonances. Here, we show that silicon nanowire (NW) pairs can display a wide range of structural colors by controlling their radiative coupling. This is accomplished by exciting a series of Fabry–Pérot-like modes where light is repeatedly scattered between two NWs. These modes are beyond the expectation from the conventional chemical bonding model under a quasi-electrostatic approximation, in which only bonding and antibonding modes can be formed in a pair system through modal hybridization. The additional eigenmodes found in a two-resonator system originate from the nonlinear, frequency-dependent coupling strength derived from the radiative nature of low- Q resonators. The Fabry–Pérot modes can be tuned across the entire visible frequency range by varying the distance between two NWs, leading to what we believe is a new type of universal building blocks that can provide structural color within a subwavelength footprint. The presented results pave the way toward the design and usage of highly tunable resonances that exploit the radiative coupling of high-index nanostructures.

Li, Qitong↗

Use of Molecular Imaging to Predict Clinical Outcome in Patients With Rectal Cancer After Preoperative Chemotherapy and Radiation

Purpose: To correlate changes in 2-deoxy-2-[18F]fluoro-D-glucose (18-FDG) positron emission tomography (PET) (18-FDG-PET) uptake with response and disease-free survival with combined modality neoadjuvant therapy in patients with locally advanced rectal cancer. Methods and Materials: Charts were reviewed for consecutive patients with ultrasound-staged T3x to T4Nx or TxN1 rectal adenocarcinoma who underwent preoperative chemoradiation therapy at Fox Chase Cancer Center (FCCC) or Robert H. Lurie Comprehensive Cancer Center of Northwestern University with 18-FDG-PET scanning before and after combined-modality neoadjuvant chemoradiation therapy . The maximum standardized uptake value (SUV) was measured from the tumor before and 3 to 4 weeks after completion of chemoradiation therapy preoperatively. Logistic regression was used to analyze the association of pretreatment SUV, posttreatment SUV, and % SUV decrease on pathologic complete response (pCR), and a Cox model was fitted to analyze disease-free survival. Results: A total of 53 patients (FCCC, n = 41, RLCCC, n = 12) underwent pre- and postchemoradiation PET scanning between September 2000 and June 2006. The pCR rate was 31%. Univariate analysis revealed that % SUV decrease showed a marginally trend in predicting pCR (p = 0.08). In the multivariable analysis, posttreatment SUV was shown a predictor of pCR (p = 0.07), but the test results did not reach statistical significance. None of the investigated variables were predictive of disease-free survival. Conclusions: A trend was observed for % SUV decrease and posttreatment SUV predicting pCR in patients with rectal cancer treated with preoperative chemoradiation therapy. Further prospective study with a larger sample size is warranted to better characterize the role of 18-FDG-PET for response prediction in patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-degree of Freedom Energy Analysis for Identification of Failure Risk in Structural Components Subjected to Random Vibration and Shock Loading

When designing or analyzing a mechanical system, energy quantities provide insight into the severity of shock and vibration environments; however, the energy methods in the literature do not address localized behavior because energy quantities are usually computed for an entire structure. The main objective of this paper is to show how to compute the energy in the components of a mechanical system. The motivation for this work is that most systems fail functionally due to component failure, not because the primary structure was overloaded, and the ability to easily compute the spatial distribution of energy helps identify failure sensitive components. The quantity of interest is input energy. That input energy can be decoupled modally is well known. What is less appreciated is that input energy can be computed at the component level exactly, using the component effective modal mass. We show the steady state input energy can be decomposed both spatially and modally and computed using input power spectra. A numerical example illustrates the spatial and modal decomposition of input energy and its utility in identifying components at risk of damage in random vibration and shock environments. Our work shows that the modal properties of the structure and the spectral content of the input must be considered together to assess damage risk. Because input energy includes absorbed energy as well as relative kinetic energy and dissipated energy, it is the recommended energy quantity for assessing the severity for both random vibration and shock environments on a structure.

42 ENGINEERING↗

O’Hare Airport Short-Term Ground Transportation Modal Demand Forecast Using Gaussian Processes

Here, the principal objective of this study is to analyze the spatial and temporal variation of ground transportation airport demand and provide demand forecast to inform planning capability and explore alternatives for investments to accommodate airport growth. Because of its good adaptability and strong generalization ability for dealing with high-dimensional input, small-sample, and nonlinear spatial data, Gaussian process (GP) regression is used to provide forecast estimates using data from transportation network company (TNC) trips and urban rail passengers at Chicago's O'Hare International Airport. TNC airport trips differ significantly, with three times more distance, more than twice the travel time, and half of the share requests compared with nonairport trips. This highlights the need for separate demand models. Hourly analysis of the rail service indicates that this is likely heavily used by airport workers, whereas TNC services focus on travelers because of variations in the peak demand hours. Heteroscedastic GP regression is implemented because of differences in trip variance between night and day hours. Estimates are given for weekdays and weekend trips, and the 95% confidence intervals are calculated. The introduction of flight schedule information into the models shows marginal improvements in their performance. However, fitting a GP regression becomes computationally expensive with increased sample size and the introduction of spatial components. Transportation planners and policymakers can use the results and methods implemented in this study to optimize transportation assets and provide long-range simulations of the current and future conditions in the area.

42 ENGINEERING↗

A dehydrated, aseptically-processed human amnion/chorion allograft accelerates healing in a delayed murine excisional wound model

Since chronic, non-healing wounds represent an increasing source of economic and temporal burden for patients who suffer from them and healthcare professionals that treat them, therapeutic modalities that promote closure of delayed and non-healing wounds are of utmost importance. Recent clinical results of allografts derived from amnion and chorion placental layers encourage further investigation of the mechanisms underlying clinical efficacy of these products for treatment of wounds. Here, we utilized a diabetic murine splinted excisional wound model to investigate the effects of a dehydrated human amnion/chorion-derived allograft (dHACA) on delayed wound healing, as well as the effects of dehydrated allograft derived solely from amnion tissue of the same donor. We examined wound healing by histological endpoint analysis, and we assessed other parameters relevant to functional wound healing in the wound bed including angiogenesis, macrophage phenotypes, proliferative activity, and gene expression. Herein we demonstrate that application of dHACA to a murine diabetic model of delayed wound progression results in better macroscale wound resolution outcomes, including rate of closure, compared to unaided wound progression, while dehydrated human amnion allograft (dHAA) fails to improve outcomes. Improved gross wound resolution observed with dHACA was accompanied by increased granulation tissue formation, proliferation and vascular ingrowth observed in the wound bed, early macrophage polarization towards anti-inflammatory phenotypes, and downregulation of pro-fibrotic gene expression. Overall, our data suggest that improvements in the rates of delayed wound closure observed from combined amnion/chorion allografts are associated with modulation of critical cellular and tissue processes commonly found to be dysregulated in delayed healing wounds, including proliferation, vascularization, inflammation, and re-epithelialization.

60 APPLIED LIFE SCIENCES↗

Variational inference of effective range parameters for 3 He− 4 He scattering

We use two different methods, Monte Carlo sampling and variational inference (VI), to perform a Bayesian calibration of the effective-range parameters in 3 He– 4 He elastic scattering. The parameters are calibrated to data from a recent set of 3 He– 4 He elastic scattering differential cross section measurements. Analysis of these data for E lab ≤ 4.3 MeV yields a unimodal posterior for which both methods obtain the same structure. However, the effective-range expansion amplitude does not account for the 7/2 − state of 7 Be so, even after calibration, the description of data at the upper end of this energy range is poor. The data up to E lab = 2.6 MeV can be well described, but calibration to this lower-energy subset of the data yields a bimodal posterior. After adapting VI to treat such a multi-modal posterior we find good agreement between the VI results and those obtained with parallel-tempered Monte Carlo sampling.

effective field theory↗

Regional Recurrence Risk Following a Negative Sentinel Node Procedure Does Not Approximate the False-Negative Rate of the Sentinel Node Procedure in Breast Cancer Patients Not Receiving Radiotherapy or Systemic Treatment

Background: Although the false-negative rate of the sentinel lymph node biopsy (SLNB) in breast cancer patients is 5–7%, reported regional recurrence (RR) rates after negative SLNB are much lower. Adjuvant treatment modalities probably contribute to this discrepancy. This study assessed the 5-year RR risk after a negative SLNB in the subset of patients who underwent breast amputation without radiotherapy or any adjuvant treatment. Methods: All patients operated for primary unilateral invasive breast cancer between 2005 and 2008 were identified in the Netherlands Cancer Registry. Patients with a negative SLNB who underwent breast amputation and who were not treated with axillary lymph node dissection, radiotherapy, or any adjuvant systemic treatment were selected. The cumulative 5-year RR rate was estimated by Kaplan–Meier analysis. Results: A total of 13,452 patients were surgically treated for primary breast cancer and had a negative SLNB, and 2012 patients fulfilled the selection criteria. Thirty-eight RRs occurred during follow-up. Multifocal disease was associated with a higher risk of developing RR (P = 0.04). The median time to RR was 27 months and was significantly shorter in patients with estrogen receptor-negative (ER−) breast cancer (9.5 months; P = 0.003). The 5-year RR rate was 2.4% in the study population compared with 1.1% in the remainder of 11,440 SLNB-negative patients (P = 0.0002). Conclusions: Excluding the effect of radiotherapy and systemic treatment resulted in a twofold 5-year RR risk in breast cancer patients with a tumor-free SLNB. This 5-year RR rate was still much lower than the reported false-negative rate of the SLNB procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗