Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Materials characterization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

TPS Certification by Analysis: Model-Driven Characterization of Properties and Failure in Woven Thermal Protection Systems

Woven, ablative thermal protection system (TPS) materials provide a robust option for aggressive (re)entries and thus have been baselined for the upcoming Mars Sample Return (MSR) mission’s Earth Entry System (EES). The reliability requirements for MSR-EES necessitate understanding of material property variability, which could be significant given the complex structure and anisotropic nature of properties in TPS weaves, as well as the response to potential impact with micrometeoroids or orbital debris during the EES re-entry. The TPS Certification by Analysis effort within the Entry Systems Modeling project seeks to provide computational models and analyses that support the certification against such material-based risks. For the present talk, focus will be given to the characterization of baseline woven TPS material properties and mechanical failure limits, which entails (1) use of computational techniques (e.g., machine learning) to interpret computed tomography images of the weave to generate representative structural models and (2) application of multiscale material modeling approaches to characterize thermomechanical and failure properties.

Justin B. Haskins↗

Materials Characterization of Electron Beam Melted Ti-6Al-4V

An in-depth material characterization of Electron Beam Melted (EBM) Ti-6Al-4V material has been completed on samples fabricated on an ARCAM A2X EBM machine. The specimens were fabricated under eight separate builds with the material divided into two lots for material testing purposes. Hot Isostatic Pressing (HIP) was utilized to close porosity from fabrication and also served as a material heat treatment to obtain the desired microstructure. The changes in the microstructure and chemistry from the powder to pre-HIP and post-HIP material have been analyzed. Several nondestructive evaluation (NDE) techniques were utilized to characterize the samples both before and after HIP. The test matrix included tensile, high cycle fatigue, low cycle fatigue, fracture toughness, and fatigue crack growth at cryogenic, room, and elevated temperatures. The mechanical properties of the EBM Ti-6Al-4V are compared to conventional Ti-6Al-4V in the annealed condition. Fractography was performed to determine failure initiation site. The EBM Ti-6Al-4V had similar or superior mechanical properties compared to conventionally manufactured Ti-6Al-4V.

Titanium↗

Development of a versatile, high-temperature, high-throughput ion irradiation system

We report ion irradiation has long been used as a surrogate for neutron irradiation experiments which are comparatively slower, more expensive, and often can leave materials activated and difficult to handle post-irradiation. However, with the growing use of combinatorial synthesis methods and high-throughput, automated characterization techniques, ion irradiation facilities will need to upgrade their capabilities to be able to accommodate these new material platforms. To address this challenge, a high-throughput ion irradiation system has been developed at the University of Wisconsin-Madison Ion Beam Laboratory (IBL). The system is capable of accommodating large sample arrays of arbitrary geometries and heat samples individually using an infrared laser to enable high-temperature, high-throughput ion irradiation while mitigating the risk of annealing the irradiation damage in nearby samples. To control stage motion, laser power, and beam current measurement, among other tasks, the program Chronos was developed which enables automated high-throughput irradiation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental and strain rate effects on graphite/epoxy composites

The hygrothermal characterization of unidirectional graphite/epoxy composites over a range of strain rates was investigated. Special techniques developed for such hygrothermal characterization are also described. The mechanical properties of the composite material were obtained and analyzed by means of a time-temperature-moisture superposition principle. The results show the following: (1) the embedded gage technique was thoroughly examined and found to be appropriate for both hygrothermal expansion and mechanical strain measurements; (2) all transverse properties were found to decrease with increasing temperature and moisture content; and (3) ultimate transverse properties were found to increase with strain rate at low temperatures but follow an opposite trend at high temperatures compared to dry specimens.

Peimandis, Konstantinos↗

Ultrasonic Characterization of Cast Austenitic Stainless Steel Microstructure: Discrimination between Equiaxed- and Columnar-Grain Material – An Interim Study

Ultrasonic nondestructive evaluation (NDE) and inspection of cast austenitic stainless steel (CASS) components used in the nuclear power industry is neither as effective nor reliable as is needed due to detrimental effects upon the interrogating ultrasonic beam and interference from ultrasonic backscatter. The root cause is the coarse-grain microstructure inherent to this class of materials. Some ultrasonic techniques perform better for particular microstructural classifications and this has led to the hypothesis that an ultrasonic inspection can be optimized for a particular microstructural class, if a technique exists to reliably classify the microstructure for feedback to the inspection. This document summarizes scoping experiments of in-situ ultrasonic methods for classification and/or characterization of the material microstructures in CASS components from the outside surface of a pipe. The focus of this study was to evaluate ultrasonic methods and provide an interim report that documents results and technical progress. An initial set of experiments were performed to test the hypothesis that in-service characterization of cast austenitic stainless steel (CASS) is feasible, and that, if reliably performed, such data would provide real-time feedback to optimize in-service inspections in the field. With this objective in mind, measurements for the experiment were restricted to techniques that should be robust if carried forward to eventual field implementation. Two parameters were investigated for their ability to discriminate between different microstructures in CASS components. The first parameter was a time-of-flight ratio of a normal incidence shear wave to that of a normal incidence longitudinal wave (TOFRSL). The ratio removed dependency on component thickness which may not be accurately reported in the field. The second parameter was longitudinal wave attenuation. The selected CASS specimens provided five equiaxed-grain material samples and five columnar-grain material samples for a two-class discrimination problem. Qualitative TOFRSL estimates and a threshold algorithm classified all 10 material samples correctly and indicated a reliable and robust technique. Qualitative longitudinal wave attenuation estimates and a threshold algorithm also classified all 10 materials samples correctly; however, the technique was not as robust as TOFRSL. The experiments provided promising results and demonstrated that good potential exists for future development of techniques to implement real-time classification of CASS material. However, the reported measurements need to be substantiated with measurements on additional specimens.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Carbon Contamination During Ion Irradiation - Accurate Detection and Characterization of its Effect on Microstructure of Ferritic/Martensitic Steels

Accelerator-based ion beam irradiation techniques have been used to study radiation effects in materials for decades. Although carbon contamination induced by ion beams in target materials is a well-known issue in some material systems, it has not been fully characterized nor quantified for studies in ferritic/martensitic (F/M) steels that are candidate materials for applications such as core structural components in advanced nuclear reactors. It is an especially important issue for this class of material because of the strong effect of carbon level on precipitate formation. In this paper, the ability to quantify carbon contamination using three common techniques, namely time-of-flight secondary ion mass spectroscopy (ToF-SIMS), atom probe tomography (APT), and transmission electron microscopy (TEM) is compared. Their effectiveness and shortcomings in determining carbon contamination are presented and discussed. The corresponding microstructural changes related to carbon contamination in ion irradiated F/M steels are also presented and briefly discussed.

36 MATERIALS SCIENCE↗

Case Studies on Facility Characterization with X-Ray Fluorescence Spectrometry

A hand-held x-ray fluorescence (XRF) analyzer is being used to characterize facilities in support of demolition activities at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Approximately 500 facilities at the U.S. Department of Energy site are being demolished under the ETTP Decontamination and Decommissioning (D and D) project. Facility characterization is being conducted to provide data for waste profiling and identify hazards to demolition workers. XRF spectrometry is a non-destructive analytical technique used to identify and quantify the elemental composition of a substance based on the intensity of its characteristic X-ray emission wavelength or energy. The Innov-X Systems{sup R} Model XT-245S XRF analyzer used at ETTP is equipped with a silver anode x-ray tube and a Si PIN diode detector. X-rays are generated by electrical current, eliminating the need for radioactive isotopes. Electronic components can be powered by either a lithium-ion battery or an A/C adapter, and the instrument is controlled by an iPAQ{sup R} pocket personal computer. The unit has two primary operating modes. Alloy analysis mode measures percent levels of elements in metals such as a pipes, valves, equipment, or construction materials. Soil mode provides parts-per-million (ppm) quantities in bulk solids like concrete dust, residue, paint chips, or soil. The hand-held unit can analyze material in place, or it can analyze samples in a test stand by remote operation. This paper present some case studies demonstrating a variety of XRF applications for facility characterization: Metal Materials Characterization, Lead Paint Identification, Hot Spot Delineation, Bulk Solids Testing. XRF has been the analytical technique of choice for identifying metal alloy components and has also been useful in analyzing bulk materials. Limitations of XRF testing include the inability to directly analyze elements with low atomic weights. Light elements such as beryllium and aluminum do not emit characteristic x-rays that the instrument can detect. However, process knowledge and existing historical data can be used to evaluate the presence of beryllium, which has been widely characterized at ETTP using industrial hygiene smear samples. Aluminum can be indirectly measured in aluminum alloys using x-ray scatter lines. The Innov-X Systems XRF has a light elements setting that employs this method, and it has been widely used on the ETTP D and D project. Another potential limitation involves analyzing samples that are radioactive, or analyzing samples in a radioactive environment. Radiation (including gamma, beta, and high energy alpha particles) acts as another excitation mechanism to create x-rays from materials being analyzed. Samples analyzed under those conditions will absorb more x-rays than just those emitted by the instrument silver anode tube, resulting in a potential high bias. This type of interference is identified by radiological surveys and minimized by relocating measurements to areas of lower activity when feasible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress With Multi-Cell Nb3Sn Cavity Development Linked With Sample Materials Characterization

Exploiting both the new Nb3Sn coating system and the materials characterization tools nearby, we report our progress in low-loss Nb3Sn films development. Nb3Sn films a few micrometers thick were grown on Nb coupons as well as single- and multi-cell cavities by the Sn-diffusion technique. Films structure and composition were investigated on coated samples and cavity cutouts with characterization tools including SEM/EDS/EBSD, AFM, XPS, SIMS towards correlating film growth and RF loss to material properties and deposition parameters. Cavity coating efforts focused on establishing techniques for coating progressively more complicated RF structures, and understanding limiting mechanisms in coated cavities. Nb3Sn coated 1.5 GHz 1-cell and 1.3 GHz 2-cell cavities have shown quality factors of 1010 at 4.3 K, with several cavities reaching above Eacc = 10 MV/m. The dominant limiting mechanisms were low field quenches and quality factor degradation above 8 MV/m. The surface data indicates a near-stoichiometric Nb3Sn consistent with the transition temperature and gap measurements. The Nb3Sn layer is covered with Nb2O5 and SnO2 native oxides and has little memory of the pre-coating surface.

Eremeev, Grigory V.↗

Comprehensive Chemical Characterization of Hydrocarbons in NIST Standard Reference Material 2779 Gulf of Mexico Crude Oil

Comprehensive chemical information is needed to understand the environmental fate and impact of hydrocarbons released during oil spills. However, chemical information remains incomplete because of the limitations of current analytical techniques and the inherent chemical complexity of crude oils. In this study, gas chromatography (GC)-amenable C 9 -C 33 hydrocarbons were comprehensively characterized from the National Institute of Standards and Technology Standard Reference Material (NIST SRM) 2779 Gulf of Mexico crude oil by GC coupled to vacuum ultraviolet photoionization mass spectrometry (GC/VUV-MS), with a mass balance of 68 ± 22%. This technique overcomes one important limitation faced by traditional GC and even comprehensive 2D gas chromatography (GC×GC): the necessity for individual compounds to be chromatographically resolved from one another in order to be characterized. VUV photoionization minimizes fragmentation of the molecular ions, facilitating the characterization of the observed hydrocarbons as a function of molecular weight (carbon number, N C ), structure (number of double bond equivalents, N DBE ), and mass fraction (mg kg -1 ), which represent important metrics for understanding their fate and environmental impacts. Linear alkanes (8 ± 1%), bran ched alkanes (11 ± 2%), and cycloalkanes (37 ± 12%) dominated the mass with the largest contribution from cycloalkanes containing one or two rings and one or more alkyl side chains (27 ± 9%). Linearity and good agreement with previous work for a subset of >100 components and for the sum of compound classes provided confidence in our measurements and represents the first independent assessment of our analytical approach and calibration methodology. Another crude oil collected from the Marlin platform (35 km northeast of the Macondo well) was shown to be chemically identical within experimental errors to NIST SRM 2779, demonstrating that Marlin crude is an appropriate surrogate oil for researchers conducting laboratory research into impacts of the DeepWater Horizon disaster.

02 PETROLEUM↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

Nanoscale chemical imaging with structured X-ray illumination

High-resolution imaging with compositional and chemical sensitivity is crucial for a wide range of scientific and engineering disciplines. Although synchrotron X-ray imaging through spectromicroscopy has been tremendously successful and broadly applied, it encounters challenges in achieving enhanced detection sensitivity, satisfactory spatial resolution, and high experimental throughput simultaneously. In this work, based on structured illumination, we develop a single-pixel X-ray imaging approach coupled with a generative image reconstruction model for mapping the compositional heterogeneity with nanoscale resolvability. This method integrates a full-field transmission X-ray microscope with an X-ray fluorescence detector and eliminates the need for nanoscale X-ray focusing and raster scanning. We experimentally demonstrate the effectiveness of our approach by imaging a battery sample composed of mixed cathode materials and successfully retrieving the compositional variations of the imaged cathode particles. Bridging the gap between structural and chemical characterizations using X-rays, this technique opens up vast opportunities in the fields of biology, environmental, and materials science, especially for radiation-sensitive samples.

Li, Jizhou↗

Metrology and Characterization Challenges for Emerging Research Materials and Devices

The International Technology Roadmap for Semiconductors (ITRS) Emerging Research Materials (ERM) and Emerging Research Devices (ERD) Technology Workgroups have identified materials and devices that could enable continued increases in the density and performance of future integrated circuit (IC) technologies and the challenges that must be overcome; however, this will require significant advances in metrology and characterization to enable progress. New memory devices and beyond CMOS logic devices operate with new state variables (e.g., spin, redox state, etc.) and metrology and characterization techniques are needed to verify their switching mechanisms and scalability, and enable improvement of operation of these devices. Similarly, new materials and processes are needed to enable these new devices. Additionally, characterization is needed to verify that the materials and their interfaces have been fabricated with required quality and performance.

36 MATERIALS SCIENCE↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic Energy Sciences Roundtable: Opportunities for Basic Research for Next-Generation Quantum Systems

For decades, scientists have predicted that devices based on “quantum phenomena” will be able to store and manipulate information to provide radical new approaches for computing, communication, and sensing. However, only recently have quantum phenomena been incorporated into technologies for next-generation computers, sensors, and detectors that demonstrate performance characteristics rivaling those of their conventional counterparts. These devices clearly demonstrate the enormous potential for future quantum-based technologies. The novel quantum device capabilities currently envisioned include enhanced resolution in imaging, sensors, and detectors; advanced cryptography for more secure communication; and significantly larger computational capabilities at speeds far greater than those possible in classical computing. However, realizing these advances requires a detailed understanding of how quantum systems (including quantum materials or assemblies of trapped ions and electrons) behave, accurate knowledge of how to integrate the components into complex systems, and precise control of the structures. In this context, creating and controlling quantum states within molecules and materials offer exciting scientific opportunities for fundamental research, as well as for enabling next-generation quantum-based technologies. Numerous questions remain, ranging from how quantum interactions may enable innovation through the creation of novel quantum systems, to how these new quantum technologies can advance our understanding of matter and chemistry at the most fundamental levels. To address these questions and identify priority research opportunities (PROs), the US Department of Energy (DOE) Office of Basic Energy Sciences (BES) convened a roundtable of experts in quantum materials and quantum systems encompassing the fields of physics, chemistry, materials synthesis science, device engineering, detector technology, and atomic-scale characterization techniques. This group of experimentalists and theorists met on October 30–31, 2017, to explore scientific research opportunities in this rapidly moving field, in which BES support can play a key role in advancing and utilizing quantum information science (QIS). The goals of this roundtable were to define the unique roles for BES in this active research field and to provide input on future research directions, forming the basis for a coordinated, long-term research effort that will enable major advances in quantum-based science and technology. BES is uniquely positioned to advance this field because of its long history of fundamental research support for both materials and chemical sciences, along with its construction and operation of world-class scientific user facilities. Fundamental research in this area is strongly coupled to DOE efforts in scientific computing, high-energy physics, and accelerator/detector research and related to activities in “Beyond Moore’s Law” computing, next-generation semiconductor materials, and exascale computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid Cylinder Torsion for Large Shear Deformation and Failure of Engineering Materials

Using a thin-walled tube torsion test to characterize a material’s shear response is a well-known technique; however, the thin walled specimen tends to buckle before reaching large shear deformation and failure. An alternative technique is the surface stress method (Nadai 1950; Wu et al. J Test Eval 20:396–402, 1992), which derives a shear stress-strain curve from the torque-angular displacement relationship of a solid cylindrical bar. The solid bar torsion test uniquely stabilizes the deformation which allows us to control and explore very large shear deformation up to failure. However, this method has rarely been considered in the literature, possibly due to the complexity of the analysis and experimental issues such as twist measurement and specimen uniformity.

42 ENGINEERING↗

Investigating new activators for small-bandgap LaX 3 (X = Br, I) scintillators

In this study, luminescence and scintillation properties of Bi 3+ , Sb 3+ , and Eu 2+ -doped LaI 3 and LaBr 3 were explored. Out of the three dopants investigated, Eu 2+ was the most promising new activator for small-bandgap LaX 3 (X = Br, I) and was further studied in the mixed-halide LaBr 3-x I x . Crystals were grown from the melt using the vertical Bridgman method. LaBr 3 :Eu 2+ 0.5% (mol) had the most favorable scintillation properties with a light output of 43,000 ph/MeV and 6% energy resolution at 662 keV. Performance of LaBr 3-x I x :Eu 2+ worsened for most samples as iodide concentration was increased. Finally, room-temperature scintillation of LaI 3 :Eu 2+ 0.1% and 0.5% was observed and is the first case of room-temperature emission reported for doped LaI 3 .

36 MATERIALS SCIENCE↗

Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252 Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead-free Zr-doped ceria ceramics with low permittivity displaying giant electrostriction

Electrostrictors, materials developing mechanical strain proportional to the square of the applied electric field, present many advantages for mechanical actuation as they convert electrical energy into mechanical, but not vice versa. Both high relative permittivity and reliance on Pb as the key component in commercial electrostrictors pose serious practical and health problems. Here we describe a low relative permittivity (<250) ceramic, Zr x Ce 1-x O 2 (x < 0.2), that displays electromechanical properties rivaling those of the best performing electrostrictors: longitudinal electrostriction strain coefficient ~10 -16 m 2 /V 2 ; relaxation frequency ≈ a few kHz; and strain ≥0.02%. Combining X-ray absorption spectroscopy, atomic-level modeling and electromechanical measurements, here we show that electrostriction in Zr x Ce 1-x O 2 is enabled by elastic dipoles produced by anharmonic motion of the smaller isovalent dopant (Zr). Unlike the elastic dipoles in aliovalent doped ceria, which are present even in the absence of an applied elastic or electric field, the elastic dipoles in Zr x Ce 1-x O 2 are formed only under applied anisotropic field. The local descriptors of electrostrictive strain, namely, the cation size mismatch and dynamic anharmonicity, are sufficiently versatile to guide future searches in other polycrystalline solids.

36 MATERIALS SCIENCE↗