Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing predictive understanding and accuracy in geological carbon dioxide storage monitoring: Simulation and history matching of tracer transport dynamics

Co-injection of conservative tracers with carbon dioxide (CO 2 ) is a viable tool for monitoring subsurface processes during geological CO 2 storage (GCS). This research investigates the simulation and history-matching of a gas tracer (sulfur hexafluoride, SF 6 ) during CO 2 flooding, employing a core flooding result in Berea sandstone. Four extensively used saturation functions are assessed for their efficacy in history matching of CO 2 /SF 6 injection at the core scale. The history-matching process incorporates particle swarm optimization (PSO) to fine-tune constitutive relationships parameters. Next, employing transport models at the aquifer scale, we interrogate the impact on tracer transport and mixing of saturation function uncertainties, arising from the non-uniqueness of constitutive relationships parameters and saturation function types. To assess the effects of geological heterogeneity on behavior of tracer breakthrough curves (BTCs), we employ two normalized parameters assessing the degree of mixing and SF 6 breakthrough time. The aquifer-scale investigation encompasses both homogeneous and heterogeneous systems with and without capillary heterogeneity effects. Our findings underscore the critical importance of addressing saturation function uncertainties, emphasizing the significance of auxiliary experiments and innovative methodologies to enhance predictive accuracy. The findings highlight significant disparities in arrival times, BTC peaks, tails, and mixing levels, even under optimal conditions. Heterogeneity, with or without capillary heterogeneity, plays a crucial role in shaping BTC variations, resulting in accelerated SF 6 breakthrough times and reduced BTC peaks. Evaluation of monitoring points distant from the injector reveals a dampening effect on the SF6 BTC peak, particularly in heterogeneous systems with capillary heterogeneity, where the peak is halved. These insights underscore the challenges associated with tracer monitoring and the necessity for enhanced methodologies to improve predictive accuracy in subsurface processes during GCS.

58 GEOSCIENCES↗

An innovative digital image correlation technique for in-situ process monitoring of composite structures in large scale additive manufacturing

As additive manufacturing (AM) continues to develop and become a standardized manufacturing method, there will be a continued need to provide in-situ monitoring during the manufacturing of polymer composite printed components. Thermal residual stress is a primary cause of failures such as interlayer disbonds or delamination, micro cracking, and dimensional instability, which can occur during or after the build. Here, we report a novel digital image correlation (DIC) adaptation to monitor thermal residual stresses during the entire print process for large-scale AM. In this work, DIC has been investigated (a) by the natural speckle produced by the polymer surface for correlation, (b) to monitor AM build, and (c) to evaluate the effect of thermal residual stress on warpage of the printed component. The natural speckle pattern of the AM material resulted in a respectable 3.57% error compared to the traditional painted speckle pattern of 3.05% error. DIC measured a 190% increase in vertical displacement at the edge of the wall compared to the center, indicating warpage during AM. This work is a step towards a non-intrusive residual stress measuring technique using DIC for large-scale AM.

36 MATERIALS SCIENCE↗

Monitoring river flow status using low-cost wildlife camera and image segmentation artificial intelligence

Continuous measurement and monitoring of surface water coverage in non-perennial streams are essential for understanding the exchange fluxes between surface and subsurface waters under both inundated and non-inundated conditions. In this study, a wildlife camera photo-based framework was developed to monitor small stream water inundation, depth, discharge, and velocity. Two advanced machine learning models, YOLOv8 and Mask2Former, were utilized to efficiently analyze images captured by wildlife cameras. The accuracy of the framework was validated against on-site depth measurements at six sites in the Yakima River Basin, along with the gage height, discharge, and velocity data from four USGS sites. This approach facilitates long-term, continuous monitoring and quantification of river intermittency and water availability with high precision and low cost, thereby advancing river ecosystem research and management.

machine learning↗

Improved geophysical monitoring of carbon sequestration through parameter linkage to reservoir modeling

Predictive reservoir modeling, even if present in the form of only basic hydrogeological model assumptions, is expected to accompany the majority of carbon capture and sequestration monitoring activities. It thus represents a source of prior information about the migration of injected fluids that can benefit geophysical survey planning and ensuing monitoring. Constraining the imaging of geophysical monitoring data with reservoir modeling is preferable over standalone geophysical imaging because of additional complementary hydrogeological information. However, fully coupled hydrogeophysical data inversion for flow-modeling parameters that control saturation predictions is an involved process. Within the context of three-dimensional electromagnetic (EM) inversion of data from borehole-to-surface layouts, we employ a "poor people's" alternative. The approach constrains geophysical inversion parameters through saturation predictions. The coupling is realized through spatially variable lower and upper parameter bounds that scale with gas saturation magnitudes, the latter provided by reservoir modeling. In this work, enhancement of three-dimensional time-lapse plume EM imaging is demonstrated for simulated sequestration into a depleted gas reservoir.

58 GEOSCIENCES↗

Elastic-wave sensitivity-guided adaptive seismic survey design for cost-effective monitoring of geological carbon storage

Effective seismic monitoring is essential for verifying CO₂ containment, detecting potential leakage, and optimizing operational decisions in geologic carbon storage. Here, this study presents a time-adaptive, elastic-wave sensitivity-guided framework for designing cost-effective seismic monitoring layouts for tracking CO₂ plume migration. The method is based on elastic-wave sensitivity analysis, which quantifies how variations in subsurface properties impact seismic wavefields. Two complementary design strategies are developed: one based on selecting a fixed number of seismic sources (Method A), and the other based on selecting source–receiver pairs contributing to a fixed fraction of cumulative elastic-wave sensitivity energy (Method B). The optimization workflow to identify source–receiver configurations with the highest detection potential is demonstrated using a hypothetical GCS scenario at the Kimberlina site in California using simulations of elastic-wave sensitivity data at multiple post-injection timesteps. Results show that both strategies adapt to evolving plume geometries and wavefield sensitivities, with Method B offering broader spatial coverage and Method A ensuring simpler deployment. This framework enables site-specific, cost-effective, and risk-informed seismic survey designs, enhancing the ability to monitor CO₂ migration over time in evolving geological environments

58 GEOSCIENCES↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and testing of a continuous maritime monitor for radionuclide aerosols

Monitoring airborne concentrations of radionuclide activity may provide a timely warning to sea-based assets to avoid contamination from a radioactive plume. The development and testing of an automated aerosol monitoring system that can capture and detect radioactive particulate from marine air is presented. A custom electrostatic precipitator (ESP) was designed to capture particulate onto a reusable collection media. The collection efficiency of the ESP system for radon progeny was determined to be ~23%. A conservative calculation of the minimum detectable concentration of 214 Bi was estimated as 0.3-8 Bq/m 3 . The system was demonstrated in continuous operation, without consumables and limited maintenance, in a marine environment at the PNNL campus in Sequim, Washington. In conclusion, a successful 2-month deployment indicates the feasibility of the approach for continuous maritime monitoring for radionuclide aerosols.

Moore, Michael E. [Pacific Northwest National Labo↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ ATR-IR monitoring of hydrothermal carbonation of wollastonite

In-situ reaction monitoring allows for the development of reaction models for hydrothermal carbonation reactions, which have recently gained attention due to their importance in CO 2 sequestration and utilization. Here, we measured the carbonation kinetics of wollastonite (β- CaSiO 3 ) powder compacts under hydrothermal conditions (90°C and 2.4atm) with the help of optical fiber-based attenuated total reflectance infrared spectroscopy (ATR-IR). Further, the fiber probe was positioned at the target area to study the reaction chemistry at the desired region of the powder compact. Absorbances of solid reactants and products were monitored throughout the entire reaction in the 1000–1600cm -1 spectral range. ATR-IR enabled the detection of amorphous silica, which allowed all solid reactants (β-CaSiO 3 ) and products (CaCO 3 and SiO 2 ) to be monitored independently and simultaneously. A linear proportionality constant between absorbance and CaCO 3 phase concentration was determined and used to construct a reaction kinetics profile for carbonate formation, which revealed a rapid reaction onset, followed by two distinct slower decaying regimes.

42 ENGINEERING↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic Analysis of Condition-Monitoring-Based Predictive Maintenance in Power Plants under Market Elasticity

Condition-monitoring-based predictive maintenance can increase the power plant availability by preventing forced outages. However, the actual on-stream time depends on market elasticity and dynamics, which are affected by cost and penetration of other power generation technologies. This paper develops a systematic approach for the economic analysis of investment in condition monitoring technologies with due consideration of market elasticity. Focus is on corrosion monitoring in coal-fired power plants (CFFPs) since corrosion in high-temperature coal-fired boilers is a leading cause of equipment failure. Investment in sensor networks for measuring corrosion and operating conditions like metal temperature and concentrations of O 2 and SO 2 is investigated. The unscented Kalman filter is used to estimate corrosion in the waterwall section of the boiler under multiple sensor networks. Electricity produced by CFPPs in the future in the U.S. due to changes in availability under market elasticity is studied. Sensitivity of the incremental net present value to factors like the number, type, and cost of sensors is analyzed.

Electrochemistry↗

Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process

Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd 3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd 3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd 3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd 3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd 3+ in different locations within the contactor system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗