Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Quasi-microscope concept for planetary missions

Viking lander cameras have returned stereo and multispectral views of the Martian surface with a resolution that approaches 2 mm/lp in the near field. A two-orders-of-magnitude increase in resolution could be obtained for collected surface samples by augmenting these cameras with auxiliary optics that would neither impose special camera design requirements nor limit the cameras field of view of the terrain. Quasi-microscope images would provide valuable data on the physical and chemical characteristics of planetary regoliths.

Huck, F. O.↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

Microscopic Lagrangian description of warm plasmas. I - Linear wave propagation. II - Nonlinear wave interactions

It is pointed out that the conventional iterative analysis of nonlinear plasma wave phenomena, which involves a direct use of Maxwell's equations and the equations describing the particle dynamics, leads to formidable theoretical and algebraic complexities, especially for warm plasmas. As an effective alternative, the Lagrangian method may be applied. It is shown how this method may be used in the microscopic description of small-signal wave propagation and in the study of nonlinear wave interactions. The linear theory is developed for an infinite, homogeneous, collisionless, warm magnetoplasma. A summary is presented of a perturbation expansion scheme described by Galloway and Kim (1971), and Lagrangians to third order in perturbation are considered. Attention is given to the averaged-Lagrangian density, the action-transfer and coupled-mode equations, and the general solution of the coupled-mode equations.

Kim, H.↗

Quasi-microscope concept for planetary missions - Stereo

The quasi-microscope has been used for stereo pictures using a small aperture placed at the right and left over the entrance aperture. A 16-degree stereo view angle yields an enhanced stereo effect. When viewed upward through a transparent support, all grains come into focus. The technique may be used for determining mineral constituents on the basis of cleavage and fracture patterns, grain details, and surface slopes used in estimating single-particle albedo and the illumination of scattering profiles.

Burcher, E. E.↗

Interpretation of scanning electron microscope measurements of minority carrier diffusion lengths in semiconductors

In scanning electron microscope (SEM) injection measurements of minority carrier diffusion lengths some uncertainties of interpretation exist when the response current is nonlinear with distance. This is significant in epitaxial layers where the layer thickness is not large in relation to the diffusion length, and where there are large surface recombination velocities on the incident and contact surfaces. An image method of analysis is presented for such specimens. A method of using the results to correct the observed response in a simple convenient way is presented. The technique is illustrated with reference to measurements in epitaxial layers of GaAs. Average beam penetration depth may also be estimated from the curve shape.

Flat, A.↗

Rotatable microscope stage

Samples mounted on rotatable microscope stage consisting of aluminum hemisphere resting in hemispherical cavity of polytetrafluoroethylene base is viewed at various angles. Stage permits operator to orient sample at selected fixed angles.

Ivanisko, J. A.↗

Microscope for high-temperature welding

Dark glass in eyepieces lets welder look at fine parts without eye damage. Previously welder had to repair barely visible crack without magnification, because necessary goggles kept eyes too far from microscope eyepieces.

Accountius, O. E.↗

Vise holds specimens for microscope

Convenient, miniature, spring-loaded clamp holds specimens for scanning electron microscope. Clamp is made out of nesting sections of studded angle-aluminum. Specimens are easier to mount and dismount with vise than with conductive adhesive or paint.

Greule, W. N.↗

Scanning-electron-microscope study of normal-impingement erosion of ductile metals

Scanning electron microscopy was used to characterize the erosion of annealed copper and aluminum surfaces produced by both single- and multiple-particle impacts. Macroscopic 3.2 mm diameter steel balls and microscopic, brittle erodant particles were projected by a gas gun system so as to impact at normal incidence at speeds up to 140 m/sec. During the impacts by the brittle erodant particles, at lower speeds the erosion behavior was similar to that observed for the larger steel balls. At higher velocities, particle fragmentation and the subsequent cutting by the radial wash of debris created a marked change in the erosion mechanism.

Brainard, W. A.↗

Interplanetary dust in the transmission electron microscope - Diverse materials from the early solar system

An analytical electron microscope study of dispersed interplanetary dust aggregates collected in the earth's stratosphere shows that, in spite of their similarities, the aggregates exhibit significant differences in composition, internal morphology, and mineralogy. Of 11 chondritic particles examined, two consist mostly of a noncrystalline chondritic material with an atomic S/Fe ratio equal to or greater than 2 in places, one consists of submicron metal and reduced silicate 'microchondrules' and sulfide grains embedded in a carbonaceous matrix, and another consists of submicron magnetic-decorated unequilibrated silicate and sulfide grains with thick low-Z coatings. Although the particles are unmetamorphosed by criteria commonly applied for chondritic meteorites, the presence of reduced chemistries and the ubiquity of mafic, instead of hydrated, silicates confirm that they are not simply C1 or C2 chondrite matrix material. The observations indicate that portions of some particles have not been significantly altered by thermal or radiation processes since their assembly, and that the particles probably contain fine debris from diverse processes in the early solar system.

Fraundorf, P.↗

Equivalence of macroscopic and microscopic Griffith conditions for subcritical crack growth

Exact relations are derived for a simple bond-snapping model of fracture and numerical results from a previous work are presented. A lattice model with a nonlinear cohesive force law is then considered. In both cases, the results confirm the equivalence of the microscopic and macroscopic Griffith conditions. The Griffith stress intensity is to be identified with the quiescent stress intensity.

Esterling, D. M.↗

Measurement of surface recombination velocity for silicon solar cells using a scanning electron microscope with pulsed beam

The role of surface recombination velocity in the design and fabrication of silicon solar cells is discussed. A scanning electron microscope with pulsed electron beam was used to measure this parameter of silicon surfaces. It is shown that the surface recombination velocity, s, increases by an order of magnitude when an etched surface degrades, probably as a result of environmental reaction. A textured front-surface-field cell with a high-low junction near the surface shows the effect of minority carrier reflection and an apparent reduction of s, whereas a tandem-junction cell shows an increasing s value. Electric fields at junction interfaces in front-surface-field and tandem-junction cells acting as minority carrier reflectors or sinks tend to alter the value of effective surface recombination velocity for different beam penetration depths. A range of values of s was calculated for different surfaces.

Daud, T.↗

Microchrons - The Rb-87/Sr-87 dating of microscopic samples

The present investigation is concerned with the extension of the Rb-Sr dating technique to microscopic samples of individual mineral grains as small as approximately 30 micrometers in size. The measurement of the isotopic composition and the relative number of atoms of Rb and Sr has presented difficulties because of the need to separate Rb from Sr due to the isobaric interference at mass 87. This separation is critical since the changes in Sr-87/Sr-86 are directly related to the age of the sample. The approach used in the considered investigation is a modified version of the direct loading technique reported by Wasserburg et al. (1977). It is shown that measurements can be conducted of the Rb and Sr isotopic compositions and Rb/Sr atom ratios in microsamples containing 10 to the 11th to 10 to the 12th atoms of Sr. Rb-Sr model ages may prove to be of considerable importance in identifying and studying interplanetary dust particles.

Papanastassiou, D. A.↗

Microscopic Lagrangian description of warm plasmas. IV - Macroscopic approximation

The averaged-Lagrangian method is applied to linear wave propagation and nonlinear three-wave interaction in a warm magnetoplasma, in the macroscopic approximation. The microscopic Lagrangian treated by Kim and Crawford (1977) and by Galloway and Crawford (1977) is first expanded to third order in perturbation. Velocity integration is then carried out, before applying Hamilton's principle to obtain a general description of wave propagation and coupling. The results are specialized to the case of interaction between two electron plasma waves and an Alfven wave. The method is shown to be more powerful than the alternative possibility of working from the beginning with a macroscopic Lagrangian density.

Kim, H.↗

Specimen Holder for Analytical Electron Microscopes

Reduces spectral contamination by spurious X-ray. Specimen holder made of compressed carbon, securely retains standard electron microscope grid (disk) 3 mm in diameter and absorbs backscattered electrons that otherwise generate spurious X-rays. Since holder inexpensive, dedicated to single specimen when numerous samples examined.

Clanton, U. S.↗

Effects of coating rectangular microscopic electrophoresis chamber with methylcellulose

One of the biggest problems in obtaining high accuracy in microscopic electrophoresis is the parabolic flow of liquid in the chamber due to electroosmotic backflow during application of the electric field. In chambers with glass walls the source of polarization leading to electroosmosis is the negative charge of the silicare and other ions that form the wall structure. It was found by Hjerten, who used a rotating 3.0 mm capillary tube for free zone electrophoresis, that precisely neutralizing this charge was extremely difficult, but if a neutral polymer matrix (formaldehyde fixed methylcellulose) was formed over the glass (quartz) wall the double layer was displaced and the viscosity at the shear plane increased so that electroosmotic flow could be eliminated. Experiments were designed to determine the reliability with which methylcellulose coating of the Zeiss Cytopherometer chamber reduced electroosmotic backflow and the effect of coating on the accuracy of cell electrophoretic mobility (EPN) determinations. Fixed rat erythrocytes (RBC) were used as test particles.

Plank, L. D.↗

Microscopic optical potential analyses of carbon-carbon elastic scattering

Utilizing eikonal phase shifts determined from a microscopic double-folding optical potential, marked improvement in the agreement between theory and experiment, for elastic carbon-carbon scattering between 200 and 300 MeV, is obtained when only those values for the nucleon-nucleon slope parameter, appropriate for diffractive scattering, are used. The appropriateness of the perturbative eikonal expansion is discussed by comparison with recent results, obtained for the same potentials, using a more exact complex Wentzell-Kramers-Brillouin (WKB) formalism.

Bidasaria, H. B.↗

Microscopic evaluation of a polyimide (PMR-15)-graphite composite

An effort to evaluate the high temperature performance of a polyimide (PMR-15)-graphite composite which consists of several plies of woven strands of carbon fibers was undertaken. The longterm effect of high temperature on the dry material was studied by exposing polished test specimens of 473 F in a oven for nearly 400 hours. Periodically the specimens were removed and observed microscopically. Gradually surface cracks began to appear and the number of cracks increased over time. At the conclusion of the exposure the specimens were graudually ground down and observed in order to determine the depth of the cracks into the interior of the material. This procedure was repeated at an exposure temperature of 550 F.

Fedderly, J. J.↗