Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MESSENGER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

835 records · Page 47

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Prokaryotic and Fungal Characterization of the Facilities Used to Assemble, Test, and Launch the OSIRIS-REx Spacecraft

To characterize the ATLO (Assembly, Test, and Launch Operations) environment of the OSIRIS-REx spacecraft, we analyzed 17 aluminum witness foils and two blanks for bacterial, archaeal, fungal, and arthropod DNA. Under NASA’s Planetary Protection guidelines, OSIRIS-REx is a Category II outbound, Category V unrestricted sample return mission. As a result, it has no bioburden restrictions. However, the mission does have strict organic contamination requirements to achieve its primary objective of returning pristine carbonaceous asteroid regolith to Earth. Its target, near-Earth asteroid (101955) Bennu, is likely to contain organic compounds that are biologically available. Therefore, it is useful to understand what organisms were present during ATLO as part of the larger contamination knowledge effort—even though it is unlikely that any of the organisms will survive the multi-year deep space journey. Even though these samples of opportunity were not collected or preserved for DNA analysis, we successfully amplified bacterial and archaeal DNA (16S rRNA gene) from 16 of the 17 witness foils containing as few as 7 ± 3 cells per sample. Fungal DNA (ITS1) was detected in 12 of the 17 witness foils. Despite observing arthropods in some of the ATLO facilities, arthropod DNA (COI gene) was not detected. We observed 1,009 bacterial and archaeal sOTUs (sub-operational taxonomic units, 100% unique) and 167 fungal sOTUs across all of our samples (25–84 sOTUs per sample). The most abundant bacterial sOTU belonged to the genus Bacillus. This sOTU was present in blanks and may represent contamination during sample handling or storage. The sample collected from inside the fairing just prior to launch contained several unique bacterial and fungal sOTUs that describe previously uncharacterized potential for contamination during the final phase of ATLO. Additionally, fungal richness (number of sOTUs) negatively correlates with the number of carbon-bearing particles detected on samples. The total number of fungal sequences positively correlates with total amino acid concentration. These results demonstrate that it is possible to use samples of opportunity to characterize the microbiology of low-biomass environments while also revealing the limitations imposed by sample collection and preservation methods not specifically designed with biology in mind.

Aaron B. Regberg↗

The Moon Burst Energetics All-sky Monitor (MoonBEAM)

MoonBEAM is a SmallSat concept placed in cislunar orbit developed to study the progenitors and multimessenger/multiwavelength signals of transient relativistic jets and outflows and determine the conditions that lead to the launching of a transient relativistic jet. The distinguishing advantage of MoonBEAM is the instantaneous all-sky coverage, maximizing the gamma-ray transients observations and providing upper limits for nondetections. Gamma-ray observatories in low Earth orbit are not able to survey the entire sky at a given time due to Earth blockage as well as detector downtime from the high particle activity in the South Atlantic Anomaly region. The long baseline provided from a cislunar orbit, allows MoonBEAM to constrain the localization annulus when combined with a gamma-ray instrument in low Earth orbit utilizing the timing triangulation technique. Improving the localization precision of a gamma-ray burst aids the gravitational wave follow-up community in reducing the region needed to be searched to locate and identify the afterglow and kilanova emission. Furthermore, by providing a different vantage point for a gamma-ray detection, MoonBEAM can help extend the gravitational wave detection horizon by increasing the confidence of a simultaneous marginal gravitational wave signal. Through the all-sky coverage, MoonBEAM will also provide insight into the conditions that lead to a successful relativistic jet, instead of a shock breakout event, or a completely failed jet in the case of core collapse supernovae.

Gamma-ray Bursts↗

Chapter Fourteen - Space Photovoltaics for Extreme High-Temperature Missions

Solar arrays in space are subjected to a daunting set of environmental hazards, including extreme temperature cycles, particulate and ultraviolet radiation in space, micrometeoroid damage, and exposure to a flux of atomic oxygen in low-Earth orbit. Over the years since the first solar cells were sent into space on Vanguard 1 in 1958, space solar array technology has advanced to develop photovoltaic materials, cells, and arrays resistant to these degradation mechanisms. This chapter highlights approaches to solar array design for near-Sun missions including thermal management at the systems level, to optimize efficiency at elevated temperature, or the use of novel device design to reduce the incident solar energy to limit operating temperature. Several of these have been successfully demonstrated to enable solar-powered spacecraft to explore the near-Sun planets such as Mercury and Venus as well as the Sun itself.

Space photooltaics↗

Curation planning and facilities for asteroid Bennu samples returned by the OSIRIS-REx mission

NASA's OSIRIS-REx spacecraft collected samples from carbonaceous near-Earth asteroid (101955) Bennu on October 20, 2020, and will deliver them to the Earth on September 24, 2023. The samples will be processed at the NASA Johnson Space Center (JSC), where most of the sample collection will be subsequently curated in a new cleanroom suite. The spacecraft collected loose regolith two ways: in a bulk sample chamber capable of holding up to 2 kg, and on industrial Velcro “contact pads” intended to collect small particles at the surface. Included in the JSC collection will be the bulk sample, the contact pads, contamination-monitoring witness plates, and supporting hardware. Planning for the curation of the samples and hardware started at the earliest phase of proposal development and continued in parallel with project development and execution. Because a major mission goal is characterization of organic compounds in the Bennu samples, extra effort was spent in the design stage to ensure a clean curation environment. Here, we describe the preparations to receive the sample, including the design, construction, outfitting, and monitoring of the cleanrooms at JSC; the planned recovery of the sample-containing capsule when it lands on Earth; and the approach to characterizing and cataloging the samples. These curation efforts will result in the distribution of pristine Bennu samples from JSC to the OSIRIS-REx science team, international partners, and the global scientific community for years to come.

curation↗