Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Magnetic Suspension Technology Development

This Cooperative Agreement, intended to support focused research efforts in the area of magnetic suspension systems, was initiated between NASA Langley Research Center (LaRC) and Old Dominion University (ODU) starting January 1, 1997. The original proposal called for a three-year effort, but funding for the second year proved to be unavailable, leading to termination of the agreement following a 5-month no-cost extension. This report covers work completed during the entire 17-month period of the award. This research built on work that had taken place over recent years involving both NASA LARC and the Principal Investigator (PI). The research was of a rather fundamental nature, although specific applications were kept in mind at all times, such as wind tunnel Magnetic Suspension and Balance Systems (MSBS), space payload pointing and vibration isolation systems, magnetic bearings for unconventional applications, magnetically levitated ground transportation and electromagnetic launch systems. Fundamental work was undertaken in areas such as the development of optimized magnetic configurations, analysis and modelling of eddy current effects, control strategies for magnetically levitated wind tunnel models and system calibration procedures. Despite the termination of this Cooperative Agreement, several aspects of the research work are currently continuing with alternative forms of support.

Britcher, Colin↗

Strain-gage balance calibration of a magnetic suspension and balance system

A load calibration of the NASA 13-in magnetic suspension and balance system (MSBS) is described. The calibration procedure was originally intended to establish the empirical relationship between the coil currents and the external loads (forces and moments) applied to a magnetically suspended calibrator. However, it was discovered that the performance of a strain-gage balance is not affected when subjected to the magnetic environment of the MSBS. The use of strain-gage balances greatly reduces the effort required to perform a current-vs.-load calibration as external loads can be directly inferred from the balance outputs while a calibrator is suspended in MSBS. It is conceivable that in the future such a calibration could become unnecessary, since an even more important application for the use of a strain-gage balance in MSBS environment is the acquisition of precision aerodynamic force and moment data by telemetering the balance outputs from a suspended model/core/balance during wind tunnel tests.

Roberts, Paul W.↗

Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity

Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

magnetic refrigeration↗

Analytical model of a five degree of freedom magnetic suspension and positioning system

An analytical model of a five degree of freedom magnetic suspension and positioning system is presented. The suspended element is a cylinder which is composed of permanent magnet material and the magnetic actuators are air core electromagnets mounted in a planar array. The analytical model consists of an open loop representation of the suspension and positioning system with electromagnet currents as inputs and displacements and rates in inertial coordinates as outputs. The uncontrolled degree of freedom is rotation about the long axis of the suspended cylinder.

Groom, Nelson J.↗

Cryogenic system design of 11 GEV/C super high momentum spectrometer superconducting magnets at Jefferson Lab

The design of the cryogenic system for the 11 GeV/c Super High Momentum Spectrometer (SHMS) is presented. A description of the cryogenic control reservoir and the cryogenic transfer line is given. Details of the cryogenic control reservoirs, cryogenic transfer lines, and pressure piping are summarized. Code compliance is ensured through following the requirements of the ASME Pressure Vessel Code and Pressure Piping Code. An elastic-plastic-analysis-based combined safety factor approach is proposed to meet the low stress requirement of ASME 2007 Section VIII, Division 2 so that Charpy V-notch (CVN) impact testing can be avoided through analysis. Material toughness requirements in ASME 2007 Section VIII, Division 2 are adopted as CVN impact testing rules of stainless steel 304 piping at 4.2 K and 77 K. A formula-based combined safety factor approach for pressure piping is also proposed to check whether the impact testing can be avoided due to low stress. Analysis and calculation have shown that no CVN impact testing of base metal and heat affected zones is required for the helium reservoir, nitrogen reservoir, and their relevant piping. Total heat loads to liquid helium and liquid nitrogen are studied also. The total heat load to LHe for SHMS is estimated to be 137 W, and the total load to LN2 is calculated to be 420 W.

36 MATERIALS SCIENCE↗

Influence of the Thickness of Gadolinium Layers on the Magnetic Properties and Magnetization Reversal Processes in Low-Dimensional Co/Gd/Co Systems

Structural and magnetic characteristics and behavior of thin-film Co/Gd/Co systems obtained by ion plasma sputtering in a magnetic field are reported. X-ray studies showed that cobalt layers in all investigated samples have a nanocrystalline structure. The mean roughness Ra of the surface of the samples does not exceed 0.5 nm and is independent of the Gd layer thickness. The shape of hysteresis loops observed for the Co/Gd/Co system depends of the thickness of the Gd layer, t{sub Gd}. The dependence of the saturation field H{sub S} on t{sub Gd} has an oscillatory character. This fact is explained by interaction of the Co layers through the intermediate Gd layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Investigation of the Structural, Magnetic, Magnetocaloric, Electrical Properties, and Spin-Polarized Tunneling Effect of the La{sub 0.5}Ca{sub 0.3}Te{sub 0.2}MnO{sub 3} System

Structural, magnetic, magnetocaloric, electrical properties, and spin-polarized tunneling effect in La{sub 0.5}Ca{sub 0.3}Te{sub 0.2}MnO{sub 3} polycrystalline were studied in details. The temperature dependence of the inverse of the magnetic susceptibility indicates the presence of ferromagnetic exchange interaction between the nearest neighbors at the Weiss temperature θp = 265.32 ± 0.109. Based on the magnetic field dependence of magnetization, M(H), and employing the thermodynamic Maxwell equation, the magnetic entropy change |ΔS{sub M}| of the studied sample was determined. The maximum entropy change value of the system was around 4.99 J kg{sup −1} K{sup −1} under a magnetic field of 5 T. Electrically, the upturned region of resistivity was observed at low temperature. The recovery of the resistivity was found to be strongly affected by the external magnetic field. The electrical data were analyzed considering various models. Interestingly, the exception of the spin-polarized tunneling (SPT) model is in good agreement with the experimental data among other models. In the current work, the SPT is the dominant mechanism leading to the rise of resistivity, while decreasing the temperature values. Magnetotransport analysis was successfully carried out using percolation model in the temperature range between around 50 K to nearly 300 K under different magnetic fields up to 8 T. The isothermal field dependence of magnetoresistance was recorded fairly well via a phenomenological model based on the spin-polarized tunneling model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic scattering and spin-orbit coupling induced magnetoresistance in nonmagnetic heavy metal and magnetic insulator bilayer systems

Here, we report on the experimental study of the angular dependent magnetoresistance (MR) of heavy metal/ferromagnetic insulator bilayer structures. Through altering the relative composition in heavy metal Pt δ Ta 1–δ alloy, we continuously tune its spin Hall angle from positive, crossing zero, and to negative and study its impact on the MR. Most notably, both spin Hall effect and MR disappear simultaneously in Pt 0.32 Ta 0.68 (3 nm)/YIG when the effective spin Hall angle vanishes, evidencing the essential role of spin-orbit coupling in heavy metal for the MR. By introducing Fe impurities, we further identify that magnetic scattering is also essential to induce the MR in Pt/Fe-doped SiO 2 at large magnetic field, where the MR ratio increases monotonically with doping level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital control of wind tunnel magnetic suspension and balance systems

Digital controllers are being developed for wind tunnel magnetic suspension and balance systems, which in turn permit wind tunnel testing of aircraft models free from support interference. Hardware and software features of two existing digital control systems are reviewed. Some aspects of model position sensing and system calibration are also discussed.

Britcher, Colin P.↗

High Thermal Conductivity Resin Systems for High Energy Physics Magnets

In Nb3Sn superconducting magnets, the cable and insulation system dominate the behavior of a completed magnet, with contributions to the mechanical behavior from the stiff, brittle components of the superconductor, the soft annealed copper stabilizer, and the properties of the composite insulation system. As these components are closely integrated on a small scale, it is of value to explore the properties of the entire system at a larger scale, to enable practical magnet design. Subscale composite testing (Stack Testing) has been used extensively to study the bulk material properties of the magnet composite structure. Small samples that mimic the fabrication process of magnets are fabricated and tested to qualify and characterize magnet insulation systems for use in future magnet projects as well as to better inform magnet designers about means for assembly and general handling processes. Subscale composite samples will be fabricated and characterized using various novel resins to work to improve magnet performance. New resin systems will be screened to allow for down selection to one or more highly promising resin systems. The work performed under this agreement at Fermilab will feed via CTD into the fabrication of subscale magnets at Lawrence Berkeley National Laboratory (LBNL) for verification of magnet performance.

43 PARTICLE ACCELERATORS↗

SolCalc: A Suite for the Calculation and the Display of Magnetic Fields Generated by Solenoid Systems

SolCalc is a software suite that computes and displays magnetic fields generated by a three dimensional (3D) solenoid system. Examples of such systems are the Mu2e magnet system and Helical Solenoids for muon cooling systems. SolCalc was originally coded in Matlab, and later upgraded to a compiled version (called MEX) to improve solving speed. Matlab was chosen because its graphical capabilities represent an attractive feature over other computer languages. Solenoid geometries can be created using any text editor or spread sheets and can be displayed dynamically in 3D. Fields are computed from any given list of coordinates. The field distribution on the surfaces of the coils can be displayed as well. SolCalc was benchmarked against a well-known commercial software for speed and accuracy and the results compared favorably.

43 PARTICLE ACCELERATORS↗

Force Measurements in Magnetic Suspension and Balance System

The description of an infrared telemetry system for measurement of drag forces in Magnetic Suspension and Balance Systems (MSBS) is presented. This system includes a drag force sensor, electronic pack and transmitter placed in the model which is of special construction, and receiver with a microprocessor-based measuring device, placed outside of the test section. Piezosensitive resonators as sensitive elements and non-magnetic steel as the material for the force sensor are used. The main features of the proposed system for load measurements are discussed and the main characteristics are presented.

Kuzin, Alexander↗

Final prototype of magnetically suspended flywheel energy storage system

A prototype of a 500 Wh magnetically suspended flywheel energy storage system was designed, built, and tested. The authors present the work done and include the following: (1) a final design of the magnetic bearing, control system, and motor/generator, (2) construction of a prototype system consisting of the magnetic bearing stack, flywheel, motor, container, and display module, and (3) experimental results for the magnetic bearings, motor, and the entire system. The successful completion of the prototype system has achieved: (1) manufacture of tight tolerance bearings, (2) stability and spin above the first critical frequency, (3) use of inside sensors to eliminate runout problems, and (4) integration of the motor and magnetic bearings.

Anand, D. K.↗

Method for improved voltage determination for pulsed power systems utilizing a magnetically insulated transmission line

Because the voltage is difficult to measure in a magnetically insulated transmission line (MITL), measurement of the currents flowing in the cathode and anode are often used with MITL theory to estimate the voltage in a given experiment. However, that estimate contains a space charge correction term whose magnitude depends on what is referred to as the g factor that describes the distribution of charge and current in the electron flow layer in the MITL. Typically, g is on the order of unity but the accuracy of the voltage estimate depends on its actual value. While the space charge correction term is small when the MITL flow is strongly insulated, it is particularly important near self-limited MITL flow. System parameters that affect the distribution of electron flow are studied here at self-limited flow in order to illustrate this matter and develop a methodology to improve the voltage determination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stabilization and control of topological magnetic solitons via magnetic nanopatterning of exchange bias systems

Stabilizing and manipulating topological magnetic quasiparticles in thin films is of great interest for potential applications in data storage and information processing. Here, we present a strategy for stabilizing magnetic vortices and Bloch lines with controlled position, vorticity, and chirality in a continuous exchange bias system. By tailoring vectorially the unidirectional anisotropy of the system at the nanoscale, via thermally assisted magnetic scanning probe lithography, we show experimentally and via micromagnetic simulations the non-volatile creation of vortex-antivortex pairs. In addition, we demonstrate the deterministic stabilization of cross and circular Bloch lines within patterned Néel magnetic domain walls. This work enables the implementation of complex functionalities based on the control of tailored topological spin-textures in spintronic and magnonic nanodevices.

Magnetic ordering↗